U105 
(2105) 
S00 
(B115) 
Source for the activation of A024 and A020 
FB 7, FB 257 
Selection of the binectors that activate alarm A024 or A020 on log. "1" 
0 = Binector B0000 
1 = Binector B0001 
etc.  
Up to SW 1.7:   A024 
(FB 7) 
SW 1.8 and later: 
i001:   
A024 
(FB 7) 
i002:   
A020 
(FB 257) 
All binector numbers 
Ind: 2 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U106 
(2106) 
S00 
(B115) 
Source for the activation of A033 and A053 
FB 8, FB 258 
Selection of the binectors that activate alarm A033 or A053 on log. "1" 
0 = Binector B0000 
1 = Binector B0001 
etc.  
Up to SW 1.7:  A033 
(FB 8) 
SW 1.8 and later: 
i001:   
A033 
(FB 8) 
i002:   
A053 
(FB 258) 
All binector numbers 
Ind: 2 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U107 
(2107) 
S00 
(B115) 
Source for the activation of A034 and A054 
FB 9, FB 259 
Selection of the binectors that activate alarm A034 or A054 on log. "1" 
0 = Binector B0000 
1 = Binector B0001 
etc.  
Up to SW 1.7:   A034 
(FB 9) 
SW 1.8 and later: 
i001:   
A034 
(FB 9) 
i002:   
A054 
(FB 259) 
All binector numbers 
Ind: 2 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
11.58  Connector/binector converters, binector/connector converters 
Only active with optional technology software S00 
U110 
(2110) 
S00 
(B120) 
Source for connector/binector converter 1 
FB 10 
Connector which must be converted to binectors B9052 (bit 0) to B9067 (bit 
15) 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U111 
(2111) 
S00 
(B120) 
Source for connector/binector converter 2 
FB 11 
Connector which must be converted to binectors B9068 (bit 0) to B9083 (bit 
15) 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U112 
(2112) 
S00 
(B120) 
Source for connector/binector converter 3 
FB 12 
Connector which must be converted to binectors B9084 (bit 0) to B9099 (bit 
15) 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
Add jpg to pdf preview - insert images into PDF in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Sample C# code to add image, picture, logo or digital photo into PDF document page using PDF page editor control
add jpg to pdf acrobat; how to add image to pdf acrobat
Add jpg to pdf preview - VB.NET PDF insert image library: insert images into PDF in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide VB.NET Programmers How to Add Images in PDF Document
add jpg to pdf file; how to add image to pdf form
11-106 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
U113 
(2113) 
S00 
(B121) 
Source for binector/connector converter 1 
FB 13 
Binectors which must be converted to connector K9113 
i001:  1
st
binector (bit 0) 
i002:  2
nd
binector (bit 1) 
... 
i016:  16
th
binector (bit 15) 
Settings: 
0 = binector B0000 
1 = binector B0001 
etc. 
All binector numbers 
Ind: 16 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U114 
(2114) 
S00 
(B121) 
Source for binector/connector converter 2 
FB 14 
Binectors which must be converted to connector K9114 
i001:  1
st
binector (bit 0) 
i002:  2
nd
binector (bit 1) 
... 
i016:  16
th
binector (bit 15) 
Settings: 
0 = binector B0000 
1 = binector B0001 
etc. 
All binector numbers 
Ind: 16 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U115 
(2115) 
S00 
(B121) 
Source for binector/connector converter 3 
FB 15 
Binectors which must be converted to connector K9115 
i001:  1
st
binector (bit 0) 
i002:  2
nd
binector (bit 1) 
... 
i016:  16
th
binector (bit 15) 
Settings: 
0 = binector B0000 
1 = binector B0001 
etc. 
All binector numbers 
Ind: 16 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
11.59  Binector/connector converter for serial interfaces 
U116 
(2116) 
(G170) 
Source for binector/connector converter for GSST1  [SW1.4 and later] 
Binectors which must be converted to connector K2020 
i001:  1
st
binector (bit 0) 
i002:  2
nd
binector (bit 1) 
... 
i016:  16
th
binector (bit 15) 
Settings: 
0 = binector B0000 
1 = binector B0001 
etc. 
All binector numbers 
Ind: 16 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U117 
(2117) 
(G171)  
(G173) 
Source for binector/connector converter for GSST2  [SW1.4 and later] 
Binectors which must be converted to connector K6020 
i001:  1
st
binector (bit 0) 
i002:  2
nd
binector (bit 1) 
... 
i016:  16
th
binector (bit 15) 
Settings: 
0 = binector B0000 
1 = binector B0001 
etc. 
All binector numbers 
Ind: 16 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
C# powerpoint - Convert PowerPoint to JPEG in C#.NET
VB.NET How-to, VB.NET PDF, VB.NET Word, VB.NET Excel, VB PowerPoint to JPEG converter library will name the converted JPEG image file Output.jpg. Add references:
how to add a picture to a pdf document; add image to pdf java
C# Word - Convert Word to JPEG in C#.NET
VB.NET How-to, VB.NET PDF, VB.NET Word, VB.NET Excel, VB.NET Word to JPEG converter library will name the converted JPEG image file Output.jpg. Add references:
add an image to a pdf acrobat; add photo to pdf in preview
SIEMENS AG    6RX1700-0AD76 
11-107 
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
U118 
(2118) 
(G172)  
(G174) 
Source for binector/connector converter for GSST3  [SW1.4 and later] 
Binectors which must be converted to connector K9020 
i001:  1
st
binector (bit 0) 
i002:  2
nd
binector (bit 1) 
... 
i016:  16
th
binector (bit 15) 
Settings: 
0 = binector B0000 
1 = binector B0001 
etc. 
All binector numbers 
Ind: 16 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U119 
(2119) 
Parameters for the Trace function of DriveMonitor 
[SW1.4 and later] 
This parameter is a setting for the exchange of process data between 
DriveMonitor and the SIMOREG converter. It must not
be changed! 
11.60  Mathematical functions 
Only active with optional technology software S00 
Adder / subtractor 
The 3 operands of a function block are selected by 3 indices each of a parameter. 
U120 to U131: 
The connectors selected via indices i001 and i002 are added, the connector selected via index i003 is subtracted. 
U120 to U122 [SW 1.8 and later]: 
The connectors selected via indices i004 and i005 are added, the connector selected via index i006 is subtracted. 
The result is limited to -200.00 to +199.99% and applied to the connector stated. 
U120 
(2120) 
S00 
(B125) 
Operands for 1st adder / subtractor (result = K9120) 
FB 20 
Operands for 13th adder / subtractor (result = K9132) 
FB 32 
(SW 1.8 and later) 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: 6 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U121 
(2121) 
S00 
(B125) 
Operands for 2nd adder / subtractor (result = K9121) 
FB 21 
Operands for 14th adder / subtractor (result = K9133) 
FB 33 
[SW 1.8 and later] 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: 6 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U122 
(2122) 
S00 
(B125) 
Operands for 3rd adder / subtractor (result = K9122) 
FB 22 
Operands for 14th adder / subtractor (result = K9134) 
FB 34 
[SW 1.8 and later] 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: 6 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U123 
(2123) 
S00 
(B125) 
Operands for 4
th
adder / subtracter (result = K9123) 
FB 23 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 3 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U124 
(2124) 
S00 
(B125) 
Operands for 5
th
adder / subtracter (result = K9124) 
FB 24 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 3 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U125 
(2125) 
S00 
(B125) 
Operands for 6
th
adder / subtracter (result = K9125) 
FB 25 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 3 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
C# Create PDF Library SDK to convert PDF from other file formats
from multiple image formats such as tiff, jpg, png, gif a PDF document in C#.NET using this PDF document creating toolkit, if you need to add some text
add multiple jpg to pdf; add jpg to pdf
C# PDF remove image library: remove, delete images from PDF in C#.
Support various formats image deletion, such as Jpeg or Jpg, Png, Gif, Bmp, Tiff and other bitmap Remove Image from PDF Page Using C#. Add necessary references:
add image to pdf; pdf insert image
11-108 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
U126 
(2126) 
S00 
(B125) 
Operands for 7
th
adder / subtracter (result = K9126) 
FB 26 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 3 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U127 
(2127) 
S00 
(B125) 
Operands for 8
th
adder / subtracter (result = K9127) 
FB 27 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 3 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U128 
(2128) 
S00 
(B125) 
Operands for 9
th
adder / subtracter (result = K9128) 
FB 28 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 3 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U129 
(2129) 
S00 
(B125) 
Operands for 10
th
adder / subtracter (result = K9129) 
FB 29 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 3 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U130 
(2130) 
S00 
(B125) 
Operands for 11
th
adder / subtracter (result = K9130) 
FB 30 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 3 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U131 
(2131) 
S00 
(B125) 
Operands for 12
th
adder / subtracter (result = K9131) 
FB 31 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 3 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
Adders / subtracters for double word connectors 
The 3 operands of a function block are selected in each case via the three indices of a parameter. 
The result is switched to a double word connector and a connector. 
The double word connector is limited to between -200.00 and +199.99%. 
The connector is limited to between –0.003052 and +0.003052% (= value range of LOW word of a double word connector  
±200% / 65536) 
U132 
(2132) 
S00 
(B151) 
Operands for 1
st
adder / subtracter  
FB 48 
Operands for 2
nd
adder / subtracter 
FB 49
[SW 1.9 and later] 
1
st
adder / subtracter: result = KK9490 and K9491 
2
nd
adder / subtracter: result = KK9492 and K9493 
i001:  Addition value for 1
st
adder/subtracter 
i002:  Addition value for 1
st
adder/subtracter  
i003:  Subtraction value for 1
st
adder/subtracter 
i004:  Addition value for 2
nd
adder/subtracter 
i005:  Addition value for 2
nd
adder/subtracter  
i006:  Subtraction value for 2
nd
adder/subtracter 
Settings: 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 6 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
Sign inverters 
The contents of the connector selected in the parameter are negated (two's complement). The result is applied to the specified connector. 
U135 
(2135) 
S00 
(B125) 
Source for 1
st
sign inverter (result = K9135) 
FB 35 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U136 
(2136) 
S00 
(B125) 
Source for 2
nd
sign inverter (result = K9136) 
FB 36 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U137 
(2137) 
S00 
(B125) 
Source for 3
rd
sign inverter (result = K9137) 
FB 37 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
VB.NET PDF remove image library: remove, delete images from PDF in
Support various formats image deletion in Visual Studio, such as Jpeg or Jpg, Png, Gif, Bmp, Tiff VB.NET: Remove Image from PDF Page. Add necessary references:
add photo to pdf form; add a picture to a pdf document
VB.NET PDF copy, paste image library: copy, paste, cut PDF images
Supported image formats, including Jpeg or Jpg, Png, Gif, Bmp, Tiff and other bitmap VB.NET DLLs: Copy, Paste, Cut Image in PDF Page. Add necessary references:
add picture to pdf preview; add jpg signature to pdf
SIEMENS AG    6RX1700-0AD76 
11-109 
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
U138 
(2138) 
S00 
(B125) 
Source for 4
th
sign inverter (result = K9138) 
FB 38 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
Switchable sign inverters 
The contents of the connector entered in the parameter for selection of a source is switched through, depending on the state of the 
binector entered in the parameter for control bit selection, as an unchanged value (when control bit = 0) or as a negated value (two's 
complement, when control bit = 1). The result is applied to the specified connector. 
U140 
(2140) 
S00 
(B125) 
Source for 1
st
switchable sign inverter 
FB 40 
Result = K9140 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U141 
(2141) 
S00 
(B125) 
Control bit for 1
st
switchable sign inverter 
FB 40 
0 = binector B0000 
1 = binector B0001 
etc. 
All binector numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U142 
(2142) 
S00 
(B125) 
Source for 2
nd
switchable sign inverter 
FB 41 
Result = K9141 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U143 
(2143) 
S00 
(B125) 
Control bit for 2
nd
switchable sign inverter 
FB 41 
0 = binector B0000 
1 = binector B0001 
etc. 
All binector numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
Divider 
The two operands (x1, x2) for each divider are selected via 2 indices each of the parameter:  
Index i001 = x1, index i002 = x2 
Index i003 = x1, index i004 = x2 [SW 1.8 and later] 
Formula: 
y
x
x
=
1 ∗100%
2
For division by 0 (x2=0) the following applies:
for x1 > 0: y = +199.99% 
for x1 = 0: y =   0.00% 
for x1 < 0: y = -200.00% 
y is limited to -200.00 to +199.99% and applied to the connector stated. 
U145 
(2145) 
S00 
(B131) 
Operands for 1st divider (result = K9145) 
FB 45
Operands for 4th divider (result = K9142) 
FB 42 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: 4 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U146 
(2146) 
S00 
(B131) 
Operands for 2nd divider (result = K9146) 
FB 46
Operands for 5th divider (result = K9143) 
FB 43 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: 4 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U147 
(2147) 
S00 
(B131) 
Operands for 3rd divider (result = K9147) 
FB 47
Operands for 6th divider (result = K9144) 
FB 44 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: 4 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
C# Word - Insert Image to Word Page in C#.NET
VB.NET How-to, VB.NET PDF, VB.NET Word, VB.NET Excel, VB.NET Add references: page = docx.GetPage(0); REImage image = new REImage(@"C:\logo2.jpg"); page.AddImage
add image to pdf file acrobat; add picture to pdf form
C# PowerPoint - Insert Image to PowerPoint File Page in C#.NET
VB.NET How-to, VB.NET PDF, VB.NET Word, VB.NET Add image to PowerPoint file page using C# GetPage(0); REImage image = new REImage(@"C:\logo2.jpg"); page.AddImage
adding image to pdf in preview; add jpg to pdf form
11-110 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
Multiplier 
The two operands (x1, x2) for each multiplier are selected via 2 indices of the parameter each:  
Index i001 = x1, Index i002 = x2 
Index i003 = x1, Index i004 = x2 [SW 1.8 and later] 
Index i005 = x1, Index i006 = x2 [SW 1.8 and later] 
Formula: 
y
x
x
=
1∗
2
100%
y is limited to -200.00 to +199.99% and applied to the connector stated. 
U150 
(2150) 
S00 
(B130) 
Operands for 1st multiplier (result = K9150) 
FB 50
Operands for 5th multiplier (result = K9430) 
FB 290
Operands for 9th multiplier (result = K9431) 
FB 291 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: 6 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U151 
(2151) 
S00 
(B130) 
Operands for 2nd multiplier (result = K9151) 
FB 51
Operands for 6th multiplier (result = K9432) 
FB 292
Operands for 10th multiplier (result = K9433) 
FB 293 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: 6 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U152 
(2152) 
S00 
(B130) 
Operands for 3rd multiplier (result = K9152) 
FB 52
Operands for 7thmultiplier (result = K9434) 
FB 294
Operands for 11th multiplier (result = K9435) 
FB 295 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: 6 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U153 
(2153) 
S00 
(B130) 
Operands for 4th multiplier (result = K9153) 
FB 53
Operands for 8the multiplier (result = K9436) 
FB 296
Operands for 12th multiplier (result = K9437) 
FB 297 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: 6 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
High-resolution multipliers/dividers 
The three operands are selected via the three indices of the parameter, i.e. index i001 = x1, index i002 = x2, index i003 = x3 
Equations: x
bit
x
x
4 32
1
2
(
)=
,  
y
x
x
x
x
x
=
=
4
3
1
2
3
Applicable for division by 0 (x2=0):
When x1 > 0: y = +199.99% 
When x1 = 0: y =   0.00% 
When x1 < 0: y = -200.00% 
y is limited to -200.00 to +199.99% and applied to the specified connector. 
U155 
(2155) 
S00 
(B131) 
Operands for 1
st
multiplier/divider (result = K9155) 
FB 55 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 3 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U156 
(2156) 
S00 
(B131) 
Operands for 2
nd
multiplier/divider (result = K9156) 
FB 56 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 3 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U157 
(2157) 
S00 
(B131) 
Operands for 3
rd
multiplier/divider (result = K9157) 
FB 57 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 3 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
Absolute-value generators with filtering 
U160 
(2160) 
S00 
(B135) 
Source for input quantity for 1
st
abs.-value generator with filter  FB 60 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
SIEMENS AG    6RX1700-0AD76 
11-111 
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
U161 
(2161) 
S00 
(B135) 
Signal injection mode for 1
st
abs.-value generator with filter 
FB 60 
Injection of signal with correct sign 
Injection of absolute value of signal 
Injection of signal with sign, inverted 
Injection of absolute value of signal, inverted 
0 to 3 
Ind: None 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
Offline 
U162 
(2162) 
S00 
(B135) 
Filter time for 1
st
abs.-value generator with filter 
FB 60  0 to 10000 
[ms] 
Ind: None 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
Offline 
U163 
(2163) 
S00 
(B135) 
Source for input quantity for 2
nd
abs.-value generator with filter  FB 61 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U164 
(2164) 
S00 
(B135) 
Signal injection mode for 2
nd
abs.-value generator with filter 
FB 61 
Injection of signal with correct sign 
Injection of absolute value of signal 
Injection of signal with sign, inverted 
Injection of absolute value of signal, inverted 
0 to 3 
Ind: None 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
Offline 
U165 
(2165) 
S00 
(B135) 
Filter time for 2
nd
abs.-value generator with filter 
FB 61 
0 to 10000 
[ms] 
Ind: None 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
Offline 
U166 
(2166) 
S00 
(B135) 
Source for input quantity for 3
rd
abs.-value generator with filter  FB 62 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U167 
(2167) 
S00 
(B135) 
Signal injection mode for 3
rd
abs.-value generator with filter 
FB 62 
Injection of signal with correct sign 
Injection of absolute value of signal 
Injection of signal with sign, inverted 
Injection of absolute value of signal, inverted 
0 to 3 
Ind: None 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
Offline 
U168 
(2168) 
S00 
(B135) 
Filter time for 3
rd
abs.-value generator with filter 
FB 62  0 to 10000 
[ms] 
Ind: None 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
Offline 
U169 
(2169) 
S00 
(B135) 
Source for input quantity for 4
th
abs.-value generator with filter  FB 63 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U170 
(2170) 
S00 
(B135) 
Signal injection mode for 4
th
abs.-value generator with filter 
FB 63 
Injection of signal with correct sign 
Injection of absolute value of signal 
Injection of signal with sign, inverted 
Injection of absolute value of signal, inverted 
0 to 3 
Ind: None 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
Offline 
U171 
(2171) 
S00 
(B135) 
Filter time for 4
th
abs.-value generator with filter 
FB 63  0 to 10000 
[ms] 
Ind: None 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
Offline 
11-112 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
11.61  Processing of connectors 
Only active with optional technology software S00 
Averager  [SW 1.8 and later] 
U172 
(2172) 
S00 
(B139) 
Source for input signal  
[SW 1.8 and later]
i001:  1st averager  (FB 16) 
i002:  2nd averager (FB 17) 
i003:  3rd averager  (FB 18) 
i004:   4. averager  (FB 19) 
Settings: 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: 4 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U173 
(2173) 
S00 
(B139) 
Number of sampling cycles 
[SW 1.8 and later]
i001:  1st averager  (FB 16) 
i002:  2nd averager (FB 17) 
i003:  3rd averager  (FB 18) 
i004:   4. averager  (FB 19) 
1 to 100 
Ind: 4 
FS=1 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
11.62  Limiters, limit-value monitors 
Only active with optional technology software S00 
Limiters 
The input variable selected with index i001 or i004 of the 1
st
parameter is limited to the limit values selected with indices i002 and i003 or 
i005 and i006 and applied to the specified connector. Violation of the limit values is signaled by means of two binectors. 
U175 
(2175) 
S00 
(B134) 
(B135) 
Source for input signal and limits for limiter 1 
FB 65 
Output = connector K9167 
i001:  Input signal 
i002:  Upper limiting value (L+) 
i003:  Lower limiting value (L-) 
Source for input signal and limits for limiter 4 
FB 212 
[SW2.0 and later] 
Output = connector K9176 
i004:  Input signal 
i005:  Upper limiting value (L+) 
i006:  Lower limiting value (L-) 
Settings: 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 6 
FS= 
i001: 0 
i002: 9165 
i003: 9166 
i004: 0 
i005: 9174 
i006: 9175 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U176 
(2176) 
S00 
(B134) 
(B135) 
Limit value for limiter 
FB 65, FB212 
i001:  Applied to connector K9165 (FB 65) 
i002:  Applied to connector K9174 (FB 212) 
[SW2.0 and later] 
-199.99 to 199.99 
[%] 
0.01% 
Ind: 2 
FS=100.00 
Type: I2 
P052 = 3 
P051 = 40 
Offline 
SIEMENS AG    6RX1700-0AD76 
11-113 
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
U177 
(2177) 
S00 
(B134) 
(B135) 
Source for input signal and limits for limiter 2 
FB 66 
Output = connector K9170 
i001:  Input signal 
i002:  Upper limiting value (L+) 
i003:  Lower limiting value (L-) 
Source for input signal and limits for limiter 5 
FB 213 
[SW2.0 and later] 
Output = connector K9179 
i004:  Input signal 
i005:  Upper limiting value (L+) 
i006:  Lower limiting value (L-) 
Settings: 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 6 
FS= 
i001: 0 
i002: 9168 
i003: 9169 
i004: 0 
i005: 9177 
i006: 9178 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U178 
(2178) 
S00 
(B134) 
(B135) 
Limit value for limiter 
FB 66, FB213 
i001:  Applied to connector K9168 (FB 66) 
i002:  Applied to connector K9177 (FB 213)  
[SW2.0 and later] 
-199.99 to 199.99 
[%] 
0.01% 
Ind: 2 
FS=100.00 
Type: I2 
P052 = 3 
P051 = 40 
Offline 
U179 
(2179) 
S00 
(B134) 
(B135) 
Source for input signal and limits for limiter 3 
FB 67 
Output = connector K9173 
i001:  Input signal 
i002:  Upper limiting value (L+) 
i003:  Lower limiting value (L-) 
Source for input signal and limits for limiter 6 
FB 214 
[SW2.0 and later] 
Output = connector K9262 
i004:  Input signal 
i005:  Upper limiting value (L+) 
i006:  Lower limiting value (L-) 
Settings: 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 6 
FS= 
i001: 0 
i002: 9171 
i003: 9172 
i004: 0 
i005: 9260 
i006: 9261 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U180 
(2180) 
S00 
(B134) 
(B135) 
Limit value for limiter 
FB 67, FB214 
i001:  Applied to connector K9171 (FB 67) 
i002:  Applied to connector K9260 (FB 214)  
[SW2.0 and later] 
-199.99 to 199.99 
[%] 
0.01% 
Ind: 2 
FS=100.00 
Type: I2 
P052 = 3 
P051 = 40 
Offline 
Limit-value monitors for double word connectors 
U181 
(2181) 
S00 
(B151) 
Source for input signal (A) and operating threshold (B) 
for 1
st
limit-value monitor for double word connectors 
FB 68
for 2
nd
limit-value monitor for double word connectors 
FB 69
[SW 1.9 and later] 
i001:  Input signal for 1
st
limit-value monitor 
i002:  Operating threshold for 1
st
limit-value monitor  
i003:  Input signal for 2
nd
limit-value monitor 
i004:  Operating threshold for 2
nd
limit-value monitor 
Settings: 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 4 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U182 
(2182) 
S00 
(B151) 
Hysteresis for 1
st
limit-value monitor for double word connectors FB 68
Hysteresis for 2
nd
limit-value monitor for double word connectors FB69
[SW 1.9 and later] 
i001:  Hysteresis for 1
st
limit-value monitor 
i002:  Hysteresis for 2
nd
limit-value monitor  
The hysteresis relates to the HIGH word of the double word connector 
0.00 to 100.00 
[%] 
0.01% 
Ind: 2 
FS=0.00 
Type: O2 
P052 = 3 
P051 = 40 
off-line 
11-114 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
Limit-value monitors with filtering 
U185 
(2185) 
S00 
(B136) 
Source for input signal (A) and operating point (B) for 
FB 70 
1
st
limit-value monitor with filtering 
i001:  Input signal 
i002:  Operating point 
Settings: 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 2 
FS= 
i001: 0 
i002: 9181 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U186 
(2186) 
S00 
(B136) 
Settable operating point for limit-value monitor 
FB 70 
Applied to connector K9181  
-200.00 to 199.99 
[%] 
0.01% 
Ind: None 
FS=0.00 
Type: I2 
P052 = 3 
P051 = 40 
Offline 
U187 
(2187) 
S00 
(B136) 
Filter time for 1
st
limit-value monitor with filtering 
FB 70 
0 to 10000 
[ms] 
Ind: None 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
Offline 
U188 
(2188) 
S00 
(B136) 
Hysteresis for 1
st
limit-value monitor with filtering 
FB 70 
0.00 to 100.00 
[%] 
0.01% 
Ind: None 
FS=0.00 
Type: O2 
P052 = 3 
P051 = 40 
Offline 
U189 
(2189) 
S00 
(B136) 
Source for input signal (A) and operating point (B) for 
FB 71 
2
nd
limit-value monitor with filtering 
i001:  Input signal 
i002:  Operating point 
Settings: 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 2 
FS= 
i001: 0 
i002: 9183 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U190 
(2190) 
S00 
(B136) 
Settable operating point for limit-value monitor 
FB 71 
Applied to connector K9183  
-200.00 to 199.99 
[%] 
0.01% 
Ind: None 
FS=0.00 
Type: I2 
P052 = 3 
P051 = 40 
Offline 
U191 
(2191) 
S00 
(B136) 
Filter time for 2
nd
limit-value monitor with filtering 
FB 71 
0 to 10000 
[ms] 
Ind: None 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
Offline 
U192 
(2192) 
S00 
(B136) 
Hysteresis for 2
nd
limit-value monitor with filtering 
FB 71 
0.00 to 100.00 
[%] 
0.01% 
Ind: None 
FS=0.00 
Type: O2 
P052 = 3 
P051 = 40 
Offline 
U193 
(2193) 
S00 
(B136) 
Source for input signal (A) and operating point (B) for 
FB 72 
3
rd
limit-value monitor with filtering 
i001:  Input signal 
i002:  Operating point 
Settings: 
0 = connector K0000 
1 = connector K0001 
etc. 
All connector 
numbers 
Ind: 2 
FS= 
i001: 0 
i002: 9185 
Type: L2 
P052 = 3 
P051 = 40 
Offline 
U194 
(2194) 
S00 
(B136) 
Settable operating point for limit-value monitor 
FB 72 
Applied to connector K9185  
-200.00 to 199.99 
[%] 
0.01% 
Ind: None 
FS=0.00 
Type: I2 
P052 = 3 
P051 = 40 
Offline 
U195 
(2195) 
S00 
(B136) 
Filter time for 3
rd
limit-value monitor with filtering 
FB 72  0 to 10000 
[ms] 
Ind: None 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
Offline 
U196 
(2196) 
S00 
(B136) 
Hysteresis for 3
rd
limit-value monitor with filtering 
FB 72 
0.00 to 100.00 
[%] 
0.01% 
Ind: None 
FS=0.00 
Type: O2 
P052 = 3 
P051 = 40 
Offline 