236
SIEMENS AG 6RX1700-0AD76
11-137
SIMOREG DC-MASTER Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U418
(2418)
*
S00
(B210)
Source for SET and RESET for RS flipflop 4
FB 218
(outputs: Q = B9556, /Q = B9557)
As for U415
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U419
(2419)
*
S00
(B210)
Source for SET and RESET for RS flipflop 5
FB 219
(outputs: Q = B9558, /Q = B9559)
As for U415
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U420
(2420)
*
S00
(B210)
Source for SET and RESET for RS flipflop 6
FB 220
(outputs: Q = B9560, /Q = B9561)
As for U415
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U421
(2421)
*
S00
(B210)
Source for SET and RESET for RS flipflop 7
FB 221
(outputs: Q = B9562, /Q = B9563)
As for U415
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U422
(2422)
*
S00
(B210)
Source for SET and RESET for RS flipflop 8
FB 222
(outputs: Q = B9564, /Q = B9565)
As for U415
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U423
(2423)
*
S00
(B210)
Source for SET and RESET for RS flipflop 9
FB 223
(outputs: Q = B9566, /Q = B9567)
As for U415
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U424
(2424)
*
S00
(B210)
Source for SET and RESET for RS flipflop 10
FB 224
(outputs: Q = B9568, /Q = B9569)
As for U415
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U425
(2425)
*
S00
(B210)
Source for SET and RESET for RS flipflop 11
FB 225
(outputs: Q = B9570, /Q = B9571)
As for U415
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U426
(2426)
*
S00
(B210)
Source for SET and RESET for RS flipflop 12
FB 226
(outputs: Q = B9572, /Q = B9573)
As for U415
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U427
(2427)
*
S00
(B210)
Source for SET and RESET for RS flipflop 13
FB 227
(outputs: Q = B9574, /Q = B9575)
As for U415
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U428
(2428)
*
S00
(B210)
Source for SET and RESET for RS flipflop 14
FB 228
(outputs: Q = B9576, /Q = B9577)
As for U415
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
D flipflops
D flipflops with RESET (Q=0), SET (Q=1) and STORE (Q=D on transition from 0 to 1) (priority: 1
st
RESET, 2
nd
SET, 3
rd
STORE).
RESET setting is enabled on POWER ON.
U430
(2430)
*
S00
(B211)
Source for SET, D, STORE and RESET for D flipflop 1
FB 230
(outputs: Q = B9490, /Q = B9491)
i001 Source for SET
i002 Source for D
i003 Source for STORE
i004 Source for RESET
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 4
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
224
11-138
SIEMENS AG 6RX1700-0AD76
SIMOREG DC-MASTER Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U431
(2431)
*
S00
(B211)
Source for SET, D, STORE and RESET for D flipflop 2
FB 231
(outputs: Q = B9492, /Q = B9493)
As for U430
All binector numbers
1
Ind: 4
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U432
(2432)
*
S00
(B211)
Source for SET, D, STORE and RESET for D flipflop 3
FB 232
(outputs: Q = B9494, /Q = B9495)
As for U430
All binector numbers
1
Ind: 4
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U433
(2433)
*
S00
(B211)
Source for SET, D, STORE and RESET for D flipflop 4
FB 233
(outputs: Q = B9496, /Q = B9497)
As for U430
All binector numbers
1
Ind: 4
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Timer 1 (0.000 to 60.000s) (output = B9580, inverted: B9581)
U440
(2440)
*
S00
(B215)
Source for input signal and reset signal for timer element 1
FB 240
i001 Source for input signal
i002 Source for reset signal for the pulse generator (if U442=3)
(in state "1", the pulse generator is set to "0")
Settings:
0 = Binector B0000
1 = Binector B0001
etc.
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U441
(2441)
S00
(B215)
Time for timer 1
FB 240
0.000 to 60.000
[s]
0.001
Ind: None
FS=0.000
Type: O2
P052 = 3
P051 = 40
Offline
U442
(2442)
*
S00
(B215)
Mode for timer 1
FB 240
0
ON delay
1
OFF delay
2
ON / OFF delay
3
Pulse generator with positive edge triggering
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Timer 2 (0.000 to 60.000s) (output = B9582, inverted: B9583)
U443
(2443)
*
S00
(B215)
Source for input signal and reset signal for timer element 2
FB 241
As for U440
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U444
(2444)
S00
(B215)
Time for timer 2
FB 241
0.000 to 60.000
[s]
0.001
Ind: None
FS=0.000
Type: O2
P052 = 3
P051 = 40
Offline
U445
(2445)
*
S00
(B215)
Mode for timer 2
FB 241
As for U442
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Timer 3 (0.000 to 60.000s) (output = B9584, inverted: B9585)
U446
(2446)
*
S00
(B215)
Source for input signal and reset signal for timer element 3
FB 242
As for U440
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U447
(2447)
S00
(B215)
Time for timer 3
FB 242
0.000 to 60.000
[s]
0.001
Ind: None
FS=0.000
Type: O2
P052 = 3
P051 = 40
Offline
U448
(2448)
*
S00
(B215)
Mode for timer 3
FB 242
As for U442
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
208
SIEMENS AG 6RX1700-0AD76
11-139
SIMOREG DC-MASTER Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
Timer 4 (0.000 to 60.000s) (output = B9586, inverted: B9587)
U449
(2449)
*
S00
(B215)
Source for input signal and reset signal for timer element 4
FB 243
As for U440
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U450
(2450)
S00
(B215)
Time for timer 4
FB 243
0.000 to 60.000
[s]
0.001
Ind: None
FS=0.000
Type: O2
P052 = 3
P051 = 40
Offline
U451
(2451)
*
S00
(B215)
Mode for timer 4
FB 243
As for U442
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Timer 5 (0.000 to 60.000s) (output = B9588, inverted: B9589)
U452
(2452)
*
S00
(B215)
Source for input signal and reset signal for timer element 5
FB 244
As for U440
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U453
(2453)
S00
(B215)
Time for timer 5
FB 244
0.000 to 60.000
[s]
0.001
Ind: None
FS=0.000
Type: O2
P052 = 3
P051 = 40
Offline
U454
(2454)
*
S00
(B215)
Mode for timer 5
FB 244
As for U442
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Timer 6 (0.000 to 60.000s) (output = B9590, inverted: B9591)
U455
(2455)
*
S00
(B215)
Source for input signal and reset signal for timer element 6
FB 245
As for U440
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U456
(2456)
S00
(B215)
Time for timer 6
FB 245
0.000 to 60.000
[s]
0.001
Ind: None
FS=0.000
Type: O2
P052 = 3
P051 = 40
Offline
U457
(2457)
*
S00
(B215)
Mode for timer 6
FB 245
As for U442
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Timer 7 (0.00 to 600.00s) (output = B9592, inverted: B9593)
U458
(2458)
*
S00
(B216)
Source for input signal and reset signal for timer element 7
FB 246
As for U440
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U459
(2459)
S00
(B216)
Time for timer 7
FB 246
0.00 to 600.00
[s]
0.01
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Offline
U460
(2460)
*
S00
(B216)
Mode for timer 7
FB 246
As for U442
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
VB.NET PDF - Convert PDF with VB.NET WPF PDF Viewer Highlight Text. Add Text. Add Text Box. Drawing Markups. PDF Print. Work PDF to image file formats with high quality, support converting PDF to PNG, JPG, BMP and
add png to pdf acrobat; how to add image to pdf file
204
11-140
SIEMENS AG 6RX1700-0AD76
SIMOREG DC-MASTER Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
Timer 8 (0.00 to 600.00s) (output = B9594, inverted: B9595)
U461
(2461)
*
S00
(B216)
Source for input signal and reset signal for timer element 8
FB 247
As for U440
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U462
(2462)
S00
(B216)
Time for timer 8
FB 247
0.00 to 600.00
[s]
0.01
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Offline
U463
(2463)
*
S00
(B216)
Mode for timer 8
FB 247
As for U442
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Timer 9 (0.00 to 600.00s) (output = B9596, inverted: B9597)
U464
(2464)
*
S00
(B216)
Source for input signal and reset signal for timer element 9
FB 248
As for U440
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U465
(2465)
S00
(B216)
Time for timer 9
FB 248
0.00 to 600.00
[s]
0.01
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Offline
U466
(2466)
*
S00
(B216)
Mode for timer 9
FB 248
As for U442
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Timer 10 (0.00 to 600.00s) (output = B9598, inverted: B9599)
U467
(2467)
*
S00
(B216)
Source for input signal and reset signal for timer element 10
FB 249
As for U440
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U468
(2468)
S00
(B216)
Time for timer 10
FB 249
0.00 to 600.00
[s]
0.01
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Offline
U469
(2469)
*
S00
(B216)
Mode for timer 10
FB 249
As for U442
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Binary signal selector switches
The control signal (binector) is selected via index i001 of the parameter.
Control signal = 0: Binector as set in index i002 is applied to the output
Control signal = 1: Binector as set in index i003 is applied to the output
U470
(2470)
*
S00
(B216)
Source for input signals for binary signal selector switch 1
FB 250
(output = B9482)
i001 Source for control signal
i002 Source for output signal when control signal = 0
i003 Source for output signal when control signal = 1
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U471
(2471)
*
S00
(B216)
Source for input signals for binary signal selector switch 2
FB 251
(output = B9483)
As for U470
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
216
SIEMENS AG 6RX1700-0AD76
11-141
SIMOREG DC-MASTER Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U472
(2472)
*
S00
(B216)
Source for input signals for binary signal selector switch 3
FB 252
(output = B9484)
As for U470
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U473
(2473)
*
S00
(B216)
Source for input signals for binary signal selector switch 4
FB 253
(output = B9485)
As for U470
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U474
(2474)
*
S00
(B216)
Source for input signals for binary signal selector switch 5
FB 254
(output = B9486)
As for U470
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
11.70 Technology controller
Only active with optional technology software S00
Technology controller: Actual value
U480
(2480)
*
S00
(B170)
Source for actual value
FB 114
Selection of connectors to be added as the actual value
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 4
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U481
(2481)
S00
FDS
(B170)
Filter time for actual value
FB 114
0.00 to 600.00
[s]
0.01
Ind: 4
FS=0.00
Type: O2
P052 = 3
P051 = 40
Online
U482
(2482)
S00
FDS
(B170)
Derivative-action time for actual value (D component)
FB 114
0.000 = D component deactivated
See also U483
0.000 to 30.000
[s]
0.001
Ind: 4
FS=0.000
Type: O2
P052 = 3
P051 = 40
Online
U483
(2483)
*
S00
FDS
(B170)
Factor for derivative-action time
FB 114
0
Derivative-action time = U482 * 1
1
Derivative-action time = U482 * 1000
0 to 1
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Technology controller: Setpoint
U484
(2484)
*
S00
(B170)
Source for setpoint
FB 114
Selection of connectors to be added as the setpoint
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 4
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U485
(2485)
S00
FDS
(B170)
Injectable additional setpoint
FB 114
This parameter setting is added to the setpoint when the binector selected
in U486 changes to the log. "1" state
-200.00 to 199.99
[%]
0.01
Ind: 4
FS=0.00
Type: I2
P052 = 3
P051 = 40
Online
U486
(2486)
*
S00
(B170)
Source for control bit for injection of additional setpoint
FB 114
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U487
(2487)
S00
FDS
(B170)
Filter time for setpoint
FB 114 0.00 to 600.00
[s]
0.01
Ind: 4
FS=0.00
Type: O2
P052 = 3
P051 = 40
Online
224
11-142
SIEMENS AG 6RX1700-0AD76
SIMOREG DC-MASTER Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
Technology controller: Controller parameters
U488
(2488)
S00
FDS
(B170)
P gain
FB 114 0.10 to 200.00
0.01
Ind: 4
FS=3.00
Type: O2
P052 = 3
P051 = 40
Online
U489
(2489)
*
S00
(B170)
Source for input quantity (x) for Kp adaptation
FB 114
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U490
(2490)
S00
FDS
(B170)
Characteristic for Kp adaptation: Threshold 1 (x1)
FB 114
0.00 to 200.00
[%]
0.01
Ind: 4
FS=0.00
Type: O2
P052 = 3
P051 = 40
Online
U491
(2491)
S00
FDS
(B170)
Characteristic for Kp adaptation: Threshold 2 (x2)
FB 114
0.00 to 200.00
[%]
0.01
Ind: 4
FS=100.00
Type: O2
P052 = 3
P051 = 40
Online
U492
(2492)
S00
FDS
(B170)
Characteristic for Kp adaptation: Minimum value (y1)
FB 114
Minimum value of Kp factor (y) when x ≤ x1
0.10 to 30.00
0.01
Ind: 4
FS=1.00
Type: O2
P052 = 3
P051 = 40
Online
U493
(2493)
S00
FDS
(B170)
Characteristic for Kp adaptation: Maximum value (y2)
FB 114
Maximum value of Kp factor (y) when x ≥ x2
0.10 to 30.00
0.01
Ind: 4
FS=1.00
Type: O2
P052 = 3
P051 = 40
Online
U494
(2494)
S00
FDS
(B170)
Reset time
FB 114
See also U495
0.010 to 60.000
[s]
0.001
Ind: 4
FS=3.000
Type: O2
P052 = 3
P051 = 40
Online
U495
(2495)
*
S00
FDS
(B170)
Factor for reset time
FB 114
0
Reset time = U494 * 1
1
Reset time = U494 * 1000
0 to 1
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Technology controller: Speed droop
A parameterizable feedback loop can be connected in parallel to the I and P components of the technology controller (acts on summation
point of setpoint and actual value). This loop can be activated and deactivated by settings in parameter U496 (loop can also be
deactivated by setting U497 = 0).
U496
(2496)
*
S00
(B170)
Source for control bit for speed droop injection
FB 114
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U497
(2497)
S00
FDS
(B170)
Speed droop
FB 114
Example:
A 10% speed droop setting causes a 10% reduction in the setpoint at a
100% controller output ("softening" of closed-loop control).
0.0 to 60.0
[%]
0.1
Ind: 4
FS=0.0
Type: O2
P052 = 3
P051 = 40
Online
U498
(2498)
S00
FDS
(B170)
Positive limit for speed droop
FB 114
0.00 to 199.99
[%]
0.01
Ind: 4
FS=100.00
Type: O2
P052 = 3
P051 = 40
Online
U499
(2499)
S00
FDS
(B170)
Negative limit for speed droop
FB 114
-200.00 to 0.00
[%]
0.01
Ind: 4
FS=-100.00
Type: I2
P052 = 3
P051 = 40
Online
182
SIEMENS AG 6RX1700-0AD76
11-143
SIMOREG DC-MASTER Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
Technology controller: Control bits
U500
(2500)
*
S00
(B170)
Source for technology controller enabling command
FB 114
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U502
(2502)
*
S00
FDS
(B170)
PI/PID controller switchover
FB 114
0
PI controller (D component is applied only in actual-value
channel)
1
PID controller (D component is applied for control deviation)
0 to 1
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
U503
(2503)
*
S00
FDS
(B170)
Set P component to zero
FB 114
0
Set controller P component to zero (i.e. to obtain pure I
controller)
1
Controller P component is active
0 to 1
1
Ind: 4
FS=1
Type: O2
P052 = 3
P051 = 40
Offline
U504
(2504)
*
S00
FDS
(B170)
Set I component to zero
FB 114
0
Set controller I component to zero (i.e. to obtain pure P
controller)
1
Controller I component is active
0 to 1
1
Ind: 4
FS=1
Type: O2
P052 = 3
P051 = 40
Offline
Technology controller: Set I component
When the state of the binector selected in U506 switches from log. "0" to "1", the I component of the technology controller is set to the
value parameterized in U505.
With this function it is possible, for example, to use the same signal (binector) to control controller enabling commands and setting of the I
component.
U505
(2505)
*
S00
(B170)
Source for setting value for I component
FB 114
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U506
(2506)
*
S00
(B170)
Source for control bit "Set I component"
FB 114
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Technology controller: Output, limitation
U507
(2507)
*
S00
(B170)
Source for variable positive limit
FB 114
After multiplication with U508, the contents of the selected connector act as
a positive limit for the technology controller output.
0 = connector K0000
1 = connector K0001
etc.
Note:
If the selected connector contains a negative value, a negative maximum
value is applied to the output of this limiter stage.
All connector
numbers
1
Ind: None
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U508
(2508)
S00
FDS
(B170)
Positive limit for output of technology controller
FB 114
See also U507
0.0 to 199.9
[%]
0.1
Ind: 4
FS=100.0
Type: O2
P052 = 3
P051 = 40
Online
150
11-144
SIEMENS AG 6RX1700-0AD76
SIMOREG DC-MASTER Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U509
(2509)
*
S00
(B170)
Source for variable negative limit
FB 114
After multiplication with U510, the contents of the selected connector act as
a negative limit for the technology controller output.
0 = connector K0000
1 = connector K0001
etc.
Note:
If the selected connector contains a positive value, a positive minimum
value is applied to the output of this limiter stage.
Note:
Connector K9252 contains the positive limiting value with inverted sign
generated by U507 and U508. By setting U509=9252 and U510=100.00,
therefore, it is possible to set the negative and positive limits symmetrically.
All connector
numbers
1
Ind: None
FS=9252
Type: L2
P052 = 3
P051 = 40
Offline
U510
(2510)
S00
FDS
(B170)
Negative limit for output of technology controller
FB 114
See also U509
0.0 to 199.9
[%]
0.1
Ind: 4
FS=100.0
Type: O2
P052 = 3
P051 = 40
Online
U511
(2511)
*
S00
(B170)
Source for variable weighting factor for output
FB 114
After multiplication with U512, the contents of the selected connector act as
a weighting factor for the technology controller output.
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U512
(2512)
S00
FDS
(B170)
Weighting factor for output
FB 114
See also U511
-100.0 to 100.0
[%]
0.1
Ind: 4
FS=100.0
Type: I2
P052 = 3
P051 = 40
Online
11.71 Velocity/speed calculators
Only active with optional technology software S00
Speed/velocity calculator
Function:
100%
act
n_
i
rated
n_
D
act
v_
∗
∗ ∗
=
π
v_act
Actual velocity
(n021, U521, K9256)
D
Diameter
(U517, U518)
n_rated
Rated speed
(U520)
i
Gear ratio
(U519)
n_act
Actual speed
(U515)
U515
(2515)
*
S00
(B190)
Source for actual speed
FB 115
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline