pdf renderer c# : Add png to pdf preview control Library platform web page asp.net winforms web browser OPI_simoreg_DC_0707_en61-part1917

SIEMENS AG    6RX1700-0AD76 
11-145 
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
Velocity/speed calculator 
Function: 
100%
rated
n_
D
i
set
v_
set
n_
∗ ∗
=
π
n_set 
Setpoint speed 
(n023, K9257) 
Diameter 
(U517, U518, U523) 
n_rated 
Rated speed 
(U520) 
Gear ratio 
(U519) 
v_set 
Setpoint velocity 
(U516) 
U516 
(2516) 
S00 
(B190) 
Source for set velocity 
FB 115 
A value of 16384 in the selected connector is equivalent to the set velocity 
set in U522  
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U517 
(2517) 
S00 
(B190) 
Source for diameter 
FB 115 
A value of 16384 in the selected connector is equivalent to the diameter set 
in U523  
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U518 
(2518) 
S00 
FDS 
(B190) 
Minimum diameter 
FB 115 
Lower limit for diameter set in U517 
10.0 to 6553,5 
[mm] 
0.1 
Ind: 4 
FS=6500.0 
Type: O2 
P052 = 3 
P051 = 40 
Online 
U519 
(2519) 
S00 
FDS 
(B190) 
Gear ratio (i) 
FB 115  1.00 to 300.00 
0.01 
Ind: 4 
FS=1.00 
Type: O2 
P052 = 3 
P051 = 40 
Online 
U520 
(2520) 
S00 
FDS 
(B190) 
Rated speed (n_rated) 
FB 115 
100 to 4000 
[rev/m] 
Ind: 4 
FS=1450 
Type: O2 
P052 = 3 
P051 = 40 
Online 
U521 
(2521) 
S00 
(B190) 
Normalization for actual velocity  
[SW 1.8 and later] 
16384 in K9256 correspond to the actual velocity set here 
0.01 to 327,67 
[m/s] 
0.01 
Ind: None 
FS=16,38 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
U522 
(2522) 
S00 
(B190) 
Normalization for set velocity  
[SW 1.8 and later] 
See parameter U516 
0.01 to 327,67 
[m/s] 
0.01 
Ind: None 
FS=16,38 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
U523 
(2523) 
S00 
(B190) 
Normalization for diameter  
[SW 1.8 and later]
See parameter U517 
10 to 60000 
[mm] 
Ind: None 
FS=1638 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
Add png to pdf preview - insert images into PDF in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Sample C# code to add image, picture, logo or digital photo into PDF document page using PDF page editor control
add an image to a pdf form; how to add jpg to pdf file
Add png to pdf preview - VB.NET PDF insert image library: insert images into PDF in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide VB.NET Programmers How to Add Images in PDF Document
add image to pdf in preview; adding images to pdf forms
11-146 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
11.72  Variable moment of inertia 
Only active with optional technology software S00 
Calculation of the variable moment of inertia  
FB 115 
Function: 
K
D
D
D
J
4
max
4
Hülse
4
V
=
J
V
Variable moment of inertia 
Diameter 
D
Hülse
Diameter of the sleeve 
D
max
Maximum diameter 
Constant 
U525 
(2525) 
S00 
(B191) 
Source for input quantities  
[SW 1.8 and later] 
0 = Connector K0000 
1 = Connector K0001 
etc. 
i001  Diameter  
(16384 are equivalent to set diameter U526) 
i002  Diameter of the sleeve 
(16384 are equivalent to set diameter U527 ) 
i003  Maximum diameter  
(16384 are equivalent to set diameter U528 ) 
i004  Constant 
(16384 are equivalent to set factor U529 ) 
All connector 
numbers 
Ind: 4 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U526 
(2526) 
S00 
(B191) 
Normalization for diameter  
[SW 1.8 and later] 
See parameter U525 
10 to 60000 
[mm] 
Ind: None 
FS=10000 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
U527 
(2527) 
S00 
(B191) 
Normalization for diameter of the sleeve  
[SW 1.8 and later] 
See parameter U525 
10 to 60000 
[mm] 
Ind: None 
FS=10000 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
U528 
(2528) 
S00 
(B191) 
Normalization for maximum diameter  
[SW 1.8 and later] 
See parameter U525 
10 to 60000 
[mm] 
Ind: None 
FS=10000 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
U529 
(2529) 
S00 
(B191) 
Normalization for constant K  
[SW 1.8 and later] 
See parameter U525 
0.01 to 100.00 
0.01 
Ind: None 
FS=1.00 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
11.73  PI controller  
Only active with optional technology software S00 
PI controller 1  = FB260 
PI controller 2  = FB261 
PI controller 3  = FB262 
PI controller 4  = FB263 
PI controller 5  = FB264 
PI controller 6  = FB265 
PI controller 7  = FB266 
PI controller 8  = FB267 
PI controller 9  = FB268 
PI controller 10  = FB269 
U530 
(2530) 
S00 
(B180... 
B189) 
Source for input quantity  
[SW 1.8 and later] 
0 = Connector K0000 
1 = Connector K0001 
etc. 
i001:  input quantity  
PI controller 1 
i002:  input quantity  
PI controller 2 
... 
i010:  input quantity  
PI controller 10 
All connector 
numbers 
Ind: 10 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
How to C#: Preview Document Content Using XDoc.Word
With the SDK, you can preview the document content according to the preview thumbnail by the ways as following. C# DLLs for Word File Preview. Add references:
add jpg to pdf form; how to add image to pdf reader
How to C#: Preview Document Content Using XDoc.PowerPoint
C# DLLs: Preview PowerPoint Document. Add necessary XDoc.PowerPoint DLL libraries into your created C# application as references. RasterEdge.Imaging.Basic.dll.
add jpeg signature to pdf; how to add picture to pdf
SIEMENS AG    6RX1700-0AD76 
11-147 
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
Enable and setting of the PI controllers 
U531 
(2531) 
S00 
(B180... 
B189) 
Source for control signals (enable PI controller)  
[SW 1.8 and later] 
0 = Binector B0000 
1 = Binector B0001 
etc. 
i001:  0 = Disable controller  
PI controller 1 
i002:  0 = Disable controller  
PI controller 2 
... 
i010:  0 = Disable controller  
PI controller 10 
i011:  1 = Freeze I component  
PI controller 1  
i012:  1 = Freeze I component  
PI controller 2  
... 
i020:  1 = Freeze I component  
PI controller 10  
i021:  1 = Freeze output  
PI controller 1  
i022:  1 = Freeze output  
PI controller 2  
... 
i030:  1 = Freeze output  
PI controller 10  
i031:  1 = Freeze I component in pos.direction   PI controller 1  
i032:  1 = Freeze I component in pos.direction   PI controller 2  
... 
i040:  1 = Freeze I component in pos.direction   PI controller 10 
i041:  1 = Freeze I component in neg.direction   PI controller 1  
i042:  1 = Freeze I component in neg.direction   PI controller 2  
... 
i050:  1 = Stop I component in neg.direction  
PI controller 10 
All binector numbers 
Ind: 50 
WE=0 
Typ: L2 
P052 = 3 
P051 = 40 
off-line 
U532 
(2532) 
S00 
(B180... 
B189) 
Source for control signals (set PI controller)  
[SW 1.8 and later] 
0 = Binector B0000 
1 = Binector B0001 
etc. 
i001:  0 = Set I component  
PI controller 1 
i002:  0 = Set I component  
PI controller 2 
... 
i010:  0 = Set I component  
PI controller 10 
i011:  0 = Set output  
PI controller 1 
i012:  0 = Set output  
PI controller 2 
... 
i020:  0 = Set output  
PI controller 10 
All binector numbers 
Ind: 20 
WE=0 
Typ: L2 
P052 = 3 
P051 = 40 
off-line 
U533 
(2533) 
S00 
(B180... 
B189) 
Source for Setting values  
[SW 1.8 and later] 
0 = Connector K0000 
1 = Connector K0001 
etc. 
i001:  Setting value for I component   PI controller 1 
i002:  Setting value for I component   PI controller 2 
... 
i010:  Setting value for I component   PI controller 10 
i011:  Setting value for Output   PI controller 1 
i012:  Setting value for Output  PI controller 2 
... 
i020:  Setting value for Output   PI controller 10 
All connector 
numbers 
Ind: 20 
WE=0 
Typ: L2 
P052 = 3 
P051 = 40 
off-line 
C# Word - Render Word to Other Images
Besides raster image Jpeg, images forms like Png, Bmp, Gif, .NET Graphics, and REImage (an intermediate class) are also supported. Add references:
add image to pdf reader; add image to pdf acrobat
C# powerpoint - Render PowerPoint to Other Images
Besides raster image Jpeg, images forms like Png, Bmp, Gif, .NET Graphics, and Add necessary XDoc.PowerPoint DLL libraries into your created C# application as
adding images to pdf files; adding an image to a pdf
11-148 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
Filtering of the input signals 
U534 
(2534) 
S00 
(B180... 
B189) 
Source for variable filtering time for the input signal  [SW 1.8 and later]
The content of the selected connector acts as filtering time for the PI 
controller after multiplication with U535. 
0 = Connector K0000 
1 = Connector K0001 
etc. 
i001:  variable filtering time 
PI controller 1 
i002:  variable filtering time 
PI controller 2 
... 
i010:  variable filtering time 
PI controller 10 
All connector 
numbers 
Ind: 10 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U535 
(2535) 
S00 
(B180... 
B189) 
Filtering time for the input signal 
[SW 1.8 and later] 
i001:  filtering time  
PI controller 1 
i002:  filtering time 
PI controller 2 
... 
i010:  filtering time 
PI controller 10 
0 to 10000 
[ms] 
Ind: 10 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
Controller parameters 
U536 
(2536) 
S00 
(B180... 
B189) 
Source for variable P gain 
[SW 1.8 and later]
The content of the selected connector acts as the P gain for the PI controller 
after multiplication with U537. 
0 = Connector K0000 
1 = Connector K0001 
etc. 
i001:  variable P gain 
PI controller 1 
i002:  variable P gain 
PI controller 2 
... 
i010:  variable P gain 
PI controller 10 
All connector 
numbers 
Ind: 10 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U537 
(2537) 
S00 
(B180... 
B189) 
PI controller P gain 
[SW 1.8 and later] 
i001:  P gain 
PI controller 1 
i002:  P gain 
PI controller 2 
... 
i010:  P gain 
PI controller 10 
0.10 to 200.00 
0.01 
Ind: 10 
FS=3.00 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
U538 
(2538) 
S00 
(B180... 
B189) 
Source for variable Integration time 
[SW 1.8 and later] 
The content of the selected connector acts as the integration time for the PI 
controller after multiplication with U539. 
0 = Connector K0000 
1 = Connector K0001 
etc. 
i001:  variable Integration time  PI controller 1 
i002:  variable Integration time  PI controller 2 
... 
i010:  variable Integration time  PI controller 10 
All connector 
numbers 
Ind: 10 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U539 
(2539) 
S00 
(B180... 
B189) 
PI controller integration time 
[SW 1.8 and later] 
i001:  Integration time 
PI controller 1 
i002:  Integration time 
PI controller 2 
... 
i010:  Integration time 
PI controller 10 
0.010 to 10.000 
[s] 
0.001 
Ind: 10 
FS=3.000 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
Control bits 
U540 
(2540) 
S00 
(B180... 
B189) 
Freeze P component  
[SW 1.8 and later] 
Controller P component frozen (i.e. pure I controller) 
Controller P component active 
i001:  PI controller 1 
i002:  PI controller 2 
... 
i010:  PI controller 10 
0 to 1 
Ind: 10 
FS=1 
Type: O2 
P052 = 3 
P051 = 40 
off-line 
C# Create PDF Library SDK to convert PDF from other file formats
Besides, using this PDF document metadata adding control, you can add some additional information to generated PDF file. Create PDF from Jpeg, png, images.
how to add a picture to a pdf document; add image in pdf using java
C# PDF: How to Create PDF Document Viewer in C#.NET with
The PDF document manipulating add-on from RasterEdge DocImage SDK for .NET is Support thumbnail image and outline preview for quick PDF document page
adding image to pdf in preview; add picture pdf
SIEMENS AG    6RX1700-0AD76 
11-149 
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
U541 
(2541) 
S00 
(B180... 
B189) 
Freeze I component  
[SW 1.8 and later] 
Controller I component frozen (i.e. pure P controller) 
Controller I component active 
i001:  PI controller 1 
i002:  PI controller 2 
... 
i010:  PI controller 10 
0 to 1 
Ind: 10 
FS=1 
Type: O2 
P052 = 3 
P051 = 40 
off-line 
Output, Limitation 
U542 
(2542) 
S00 
(B180... 
B189) 
Source for variable positive limit  
[SW 1.8 and later] 
The content of the selected connector acts as the positive limit for the 
output of the PI controller after multiplication with U543. 
0 = Connector K0000 
1 = Connector K0001 
etc. 
i001:  PI controller 1 
i002:  PI controller 2 
... 
i010:  PI controller 10 
Note: 
If the content of the selected connector has a negative value, this causes a 
negative maximum value at the output of this limiter stage. 
All connector 
numbers 
Ind: 10 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U543 
(2543) 
S00 
(B180... 
B189) 
Positive limit for the output of the PI controller  
[SW 1.8 and later] 
See also U542 
0.0 to 199.9 
[%] 
0.1 
Ind: 10 
FS=100.0 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
U544 
(2544) 
S00 
(B180... 
B189) 
Source for variable negative Limit  
[SW 1.8 and later] 
The content of the selected connector acts as the  negative limit for the 
output of the technology controller after multiplication with U510. 
0 = Connector K0000 
1 = Connector K0001 
etc. 
i001:  PI controller 1 
i002:  PI controller 2 
... 
i010:  PI controller 10 
Note:
If the content of the selected connector has a positive value, this causes a 
positive minimum value at the output of this limiter stage. 
Note:
Connectors K9306 to K9396 contain for PI controllers 1 to 10 the positive 
limitation values  formed by U542 and U543 with an inverted sign. In this 
way it is possible to set the negative limitation symmetrically to the positive 
limitation by setting U544= 9306 to 9396 and U545=100.0. 
All connector 
numbers 
Ind: 10 
FS= 
i001: 9306 
i002: 9316 
i003: 9326 
i004: 9336 
i005: 9346 
i006: 9356 
i007: 9366 
i008: 9376 
i009: 9386 
i010: 9396 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U545 
(2545) 
S00 
(B180... 
B189) 
Negative limit for the output of the PI controller 
[SW 1.8 and later] 
See also U544 
0.0 to 199.9 
[%] 
0.1 
Ind: 10 
FS=100.0 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
VB.NET PDF File Compress Library: Compress reduce PDF size in vb.
Remove bookmarks, annotations, watermark, page labels and article threads from PDF while compressing. Also a preview component enables compressing and
add image pdf document; add jpg to pdf online
C# PDF Page Insert Library: insert pages into PDF file in C#.net
from various file formats, such as PDF, Tiff, Word, Excel, PowerPoint, Bmp, Jpeg, Png, Gif, and DLLs for Inserting Page to PDF Document. Add necessary references
add jpg to pdf acrobat; how to add image to pdf document
11-150 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
11.74  Closed-loop control elements 
Only active with optional technology software S00 
Derivative / delay elements   SW 1.8 and later 
FB 270 to FB 279 
U550 
(2550) 
S00 
(B156)  
(B157)  
(B158) 
Source for input quantity  
[SW 1.8 and later]
0 = Connector K0000 
1 = Connector K0001 
etc. 
i001:  Input quantity derivative/delay element 1 
(FB 270) 
i002:  Input quantity derivative/delay element 2 
(FB 271) 
i003:  Input quantity derivative/delay element 3 
(FB 272) 
i004:  Input quantity derivative/delay element 4 
(FB 273) 
i005:  Input quantity derivative/delay element 5 
(FB 274) 
i006:  Input quantity derivative/delay element 6 
(FB 275) 
i007:  Input quantity derivative/delay element 7 
(FB 276) 
i008:  Input quantity derivative/delay element 8 
(FB 277) 
i009:  Input quantity derivative/delay element 9 
(FB 278) 
i010:  Input quantity derivative/delay element 10 
(FB 279) 
All connector 
numbers 
Ind: 10 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U551 
(2551) 
S00 
(B156)  
(B157)  
(B158) 
Source for multiplier for derivative-action time 
[SW 1.8 and later] 
0 = Connector K0000 
1 = Connector K0001 
etc.  
i001:  Multiplier 
derivative/delay element 1 
(FB 270) 
i002:  Multiplier 
derivative/delay element 2 
(FB 271) 
I003:  Multiplier 
derivative/delay element 3 
(FB 272) 
i004:  Multiplier 
derivative/delay element 4 
(FB 273) 
i005:  Multiplier 
derivative/delay element 5 
(FB 274) 
i006:  Multiplier 
derivative/delay element 6 
(FB 275) 
i007:  Multiplier 
derivative/delay element 7 
(FB 276) 
i008:  Multiplier 
derivative/delay element 8 
(FB 277) 
i009:  Multiplier 
derivative/delay element 9 
(FB 278) 
i010:  Multiplier 
derivative/delay element 10 
(FB 279) 
All connector 
numbers 
Ind: 10 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U552 
(2552) 
S00 
(B156)  
(B157)  
(B158) 
Derivative-action time  
[SW 1.8 and later] 
i001:  Der.-act.time deriv./delay element 1 
(FB 270) 
i002:  Der.-act.time deriv./delay element 2 
(FB 271) 
i003:  Der.-act.time deriv./delay element 3 
(FB 272) 
i004:  Der.-act.time deriv./delay element 4 
(FB 273) 
i005:  Der.-act.time deriv./delay element 5 
(FB 274) 
i006:  Der.-act.time deriv./delay element 7 
(FB 276) 
i008:  Der.-act.time deriv./delay element 8 
(FB 277) 
i009:  Der.-act.time deriv./delay element 9 
(FB 278) 
i010:  Der.-act.time deriv./delay element 10 
(FB 279) 
0 to 10000 
[ms] 
Ind: 10 
FS=100 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
U553 
(2553) 
S00 
(B156)  
(B157)  
(B158) 
Source for multiplier for filtering time 
[SW 1.8 and later] 
0 = Connector K0000 
1 = Connector K0001 
etc.  
i001:  Multiplier 
derivative/delay element 1 
(FB 270) 
i002:  Multiplier 
derivative/delay element 2 
(FB 271) 
i003:  Multiplier 
derivative/delay element 3 
(FB 272) 
i004:  Multiplier 
derivative/delay element 4 
(FB 273) 
i005:  Multiplier 
derivative/delay element 5 
(FB 274) 
i006:  Multiplier 
derivative/delay element 6 
(FB 275) 
i007:  Multiplier 
derivative/delay element 7 
(FB 276) 
i008:  Multiplier 
derivative/delay element 8 
(FB 277) 
i009:  Multiplier 
derivative/delay element 9 
(FB 278) 
i010:  Multiplier 
derivative/delay element 10 
(FB 279) 
All connector 
numbers 
Ind: 10 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
SIEMENS AG    6RX1700-0AD76 
11-151 
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
U554 
(2554) 
S00 
(B156)  
(B157)  
(B158) 
Filtering time  
[SW 1.8 and later] 
i001:  Filtering time derivative/delay element 1 
(FB 270) 
i002:  Filtering time derivative/delay element 2 
(FB 271) 
i003:  Filtering time derivative/delay element 3 
(FB 272) 
i004:  Filtering time derivative/delay element 4 
(FB 273) 
i005:  Filtering time derivative/delay element 5 
(FB 274) 
i006:  Filtering time derivative/delay element 6 
(FB 275) 
i007:  Filtering time derivative/delay element 7 
(FB 276) 
i008:  Filtering time derivative/delay element 8 
(FB 277) 
i009:  Filtering time derivative/delay element 9 
(FB 278) 
i010:  Filtering time derivative/delay element 10 
(FB 279) 
0 to 10000 
[ms] 
Ind: 10 
FS=100 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
11.75  Commutation monitoring  
n560 
n569 
n570 
n571 
n572 
n574 
n575 
n576 
U577 
U578 
Parameters for SIMOREG DC-MASTER Converter Commutation 
Protector (SIMOREG CCP) 
U580 
(2580) 
Control word for commutation monitoring 
[SW 2.1 and later]
The commutation of the converter is constantly monitored. If a commutation 
failure is detected, fault message F030 is activated and the thyristor is 
quenched by the SIMOREG CCP (if installed). 
Detection of a commutation failure is based on three decision criteria. They 
can be individually activated/deactivated with this parameter for test 
purposes. 
0: 
None of the three decision criteria are evaluated 
1: 
Decision criterion 1 (sufficient voltage time area for 
commutation) is evaluated 
2: 
Decision criterion 2 (curvature of the current crest curve) is 
evaluated 
4: 
Decision criterion 3 (maximum current actual value) is evaluated
Setting instruction: 
Each decision criterion has a numeric code. 
If more than one decision criterion is to be evaluated, the sum of the 
relevant digits must be entered. 
If U806 is  2 (i.e. the basic unit is a slave connected in parallel), decision 
criterion 1 is not evaluated irrespective of the setting of U580. 
0 to 7 
Ind: none 
FS=7 
Type: O2 
P052 = 3 
P051 = 40 
online 
U581 
(2581) 
Diagnostic memory for commutation monitoring 
[SW 2.1 and later] 
This memory is updated every time fault message F030 is activated.  
It provides the SIEMENS specialist with more detailed information about the 
cause of the commutation failure. 
0 to 65535 
Ind: 68 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
online 
U582 
(2582) 
Reaction of commutation monitor 
[SW 2.1 and later] 
This parameter allows the reaction of the commutation monitor to be 
programmed. 
Detection of a commutation failure or overcurrent results in 
immediate pulse blocking and generation of warning A030. The 
pulses are enabled again after approximately 20ms and warning 
A030 is reset. 
Detection of a commutation failure or overcurrent results in 
immediate pulse blocking and generation of fault message 
F030. 
Important:
The setting U582 = 1 is not allowed when the SIMOREG CCP is selected 
(P790 = 6)! 
1 to 2 
Ind: none 
FS=2 
Type: O2 
P052 = 3 
P051 = 40 
online 
U583 
(2583) 
Parameter for SIMOREG CCP 
11-152 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
11.76  Setpoint reduction 
U607 
(2607) 
*  
BDS 
(G135) 
Source for activation of the setpoint reduction 
[SW 1.6 and later] 
0 = Binector B0000 
1 = Binector B0001 
etc. 
Setpoint reduction active 
The Setpoint (before the ramp-function generator) is multiplied 
by the factor set in parameter U608 
No setpoint reduction 
All binector numbers 
Ind: 2 
FS=1 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U608 
(2608) 
FDS 
(G135) 
Multiplier for speed setpoint on activation of the setpoint reduction[SW 
1.6 and later] 
0.00 to 100.00 
[%] 
0.01% 
Ind: 4 
FS=15.00 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
11.77  Definition of the function of inputs and outputs 
U616 
(2616) 
(G117) 
Control word for input "E stop" (term. 105 to 108)  
[SW 2.0 and later] 
0 = E stop has same effect as OFF2 
1 = E stop immediately cancels the firing pulse chain (without waiting for 
I = 0 and without outputting α
w
0 to 1 
Ind: none 
FS=0 
Type: O2 
P052 = 3 
P051 = 40 
online 
11.78  Definition of the function of the relay output at terminals 109 / 110 
U619 
(2619) 
*  
BDS 
(G117) 
Source for the relay output  "line contactor ON" (terminals 109 / 110) 
[SW 1.7 and later] 
0 = Binector B0000 
1 = Binector B0001 
etc. 
124 = Main contactor ON 
All binector numbers 
Ind: 2 
FS=124 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
11.79  Starting pulse – Speed controller 
(See also Chapter 8 Function Diagram Sheet G150) 
U651 
(2651) 
FDS 
(G150) 
Starting pulse (integrator setting value for the speed controller)  
[SW 1.7 and later] 
-100.00 to 100.00 
[%] 
0.01% 
Ind: 4  
FS=0.00 
Type: I2 
P052 = 3 
P051 = 40 
on-line 
U652 
(2652) 
FDS 
(G150) 
Multiplier for starting pulse with neg. setpoint 
[SW 1.7 and later] 
if the starting pulse acc. to U651 is also used for pos. setpoint 
0.00 to 200.00 
[%] 
0.01% 
Ind: 4  
FS=50.00 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
U653 
(2653) 
FDS 
(G150) 
Starting pulse with neg. setpoint 
[SW 1.7 and later] 
-100.00 to 100.00 
[%] 
0.01% 
Ind: 4  
FS=0.00 
Type: I2 
P052 = 3 
P051 = 40 
on-line 
U655 
(2655) 
(G150) 
Source for Starting pulse 
[SW 1.7 and later] 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=451 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U656 
(2656) 
(G150) 
Source for starting pulse with neg. setpoint 
[SW 1.7 and later] 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: None 
FS=452 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U657 
(2657) 
*  
BDS 
(G150) 
Source for switchover starting pulse for pos./neg. setp. 
[SW 1.7 and later] 
0 = Binector B0000 
1 = Binector B0001 
etc. 
All binector numbers 
Ind: 2 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
SIEMENS AG    6RX1700-0AD76 
11-153 
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
11.80  Evaluation of a 4-step master switch for cranes 
(See also Chapter 8 Function Diagram Sheet G125) 
U660 
(2660) 
(G125) 
Source for travel command 1 
[SW 1.7 and later] 
0 = Binector B0000 
1 = Binector B0001 
etc. 
All binector numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U661 
(2661) 
(G125) 
Source for travel command 2 
[SW 1.7 and later] 
0 = Binector B0000 
1 = Binector B0001 
etc. 
All binector numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U662 
(2662) 
(G125) 
Source for switchover to setpoint step S2 
[SW 1.7 and later] 
0 = Binector B0000 
1 = Binector B0001 
etc. 
All binector numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U663 
(2663) 
(G125) 
Source for switchover to setpoint step S3 
[SW 1.7 and later] 
0 = Binector B0000 
1 = Binector B0001 
etc. 
All binector numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U664 
(2664) 
(G125) 
Source for switchover to setpoint step S4 
[SW 1.7 and later] 
0 = Binector B0000 
1 = Binector B0001 
etc. 
All binector numbers 
Ind: None 
FS=0 
Type: L2 
P052 = 3 
P051 = 40 
off-line 
U665 
(2665)  
(G125) 
Setpoint for setpoint step S1  
[SW 1.7 and later] 
0.00 to 110.00 
[%] 
0.01% 
Ind: None 
FS=10.00 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
U666 
(2666)  
(G125) 
Setpoint for setpoint step S2  
[SW 1.7 and later] 
0.00 to 110.00 
[%] 
0.01% 
Ind: None 
FS=25.00 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
U667 
(2667)  
(G125) 
Setpoint for setpoint step S3  
[SW 1.7 and later] 
0.00 to 110.00 
[%] 
0.01% 
Ind: None 
FS=40.00 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
U668 
(2668)  
(G125) 
Setpoint for setpoint step S4  
[SW 1.7 and later] 
0.00 to 110.00 
[%] 
0.01% 
Ind: None 
FS=100.00 
Type: O2 
P052 = 3 
P051 = 40 
on-line 
11.81  Position/positional deviation acquisition 
Only active with optional technology software S00 
U670 
(2670) 
S00 
(B152) 
Source for actual position values 
FB 54
[SW 2.0 and later] 
Selection of connector whose values are to be used as actual position 
values. 
i001:  Actual position value 1 
i002:  Actual position value 2 
Settings: 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: 2 
FS= 
i001: 46 
i002: 0 
Type: L2 
P052 = 2 
P051 = 40 
offline 
11-154 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
PNU 
Description 
Value range 
[Unit] 
Steps 
No. indices 
Factory 
setting 
Type 
See 
Change 
(Access / 
Status) 
U671 
(2671) 
S00 
(B152) 
Source for setting/resetting signal for position acquisition 
FB 54
[SW 2.0 and later] 
Selection of binector whose value is to be used as the setting or resetting 
signals. 
i001:  Reset actual position value 1 
i002:  Set actual position value 1 
i003:  Reset actual position value 2 
i004:  Set actual position value 2 
i005:  Reset positional deviation 
i006:  Set positional deviation 
Settings: 
0 = Binector B0000 
1 = Binector B0001 
etc. 
All binector numbers 
Ind: 6 
FS=0 
Type: L2 
P052 = 2 
P051 = 40 
offline 
U672 
(2672) 
S00 
(B152) 
Source for setting values 
FB 54
[SW 2.0 and later]
Selection of connectors whose values are to be used as setting values 
i001:  Setting value for position 1 
i002:  Setting value for position 2 
i003:  Setting value for positional deviation 
Settings: 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: 3 
FS= 
i001: 9471 
i002: 9472 
i003: 9473 
Type: L2 
P052 = 2 
P051 = 40 
offline 
U673 
(2673) 
FDS 
S00 
(B152) 
Numerator of transformation ratio  
FB 54
for actual position value 2 
[SW 2.0 and later] 
U673 must be less than or equal to U674, otherwise F058 is output with 
fault value 14 
-32766 to 32766 
Ind: 4 
FS=10000 
Type: I2 
P052 = 2 
P051 = 40 
off-line 
U674 
(2674) 
FDS 
S00 
(B152) 
Denominator of transformation ratio  
FB 54
for actual position value 2 
[SW 2.0 and later] 
1 to 32767 
Ind: 4 
FS=10000 
Type: O2 
P052 = 2 
P051 = 40 
offline 
U675 
(2675) 
S00 
(B152) 
Source for connecting the positional deviation offset 
FB 54
[SW 2.0 and later] 
Selection of the binector whose value connects the offset of the positional 
deviation 
Settings: 
0 = Binector B0000 
1 = Binector B0001 
etc. 
All binector numbers 
Ind: none 
FS=0 
Type: L2 
P052 = 2 
P051 = 40 
offline 
U676 
(2676) 
S00 
(B152) 
Source for positional deviation offset 
FB 54
[SW 2.0 and later] 
Selection of the connector whose value is to be used as the offset of the 
positional deviation 
Settings: 
0 = Connector K0000 
1 = Connector K0001 
etc. 
All connector 
numbers 
Ind: none 
FS=9474 
Type: L2 
P052 = 2 
P051 = 40 
offline 
U677 
(2677) 
S00 
(B152) 
Fixed values for position acquisition 
FB 54
[SW 2.0 and later] 
i001:  LOW word of double-word connector KK9471 
i002:  HIGH word of double-word connector KK9471 
i003:  LOW word of double-word connector KK9472 
i004:  HIGH word of double-word connector KK9472 
i005:  LOW word of double-word connector KK9473 
i006:  HIGH word of double-word connector KK9473 
i007:  LOW word of double-word connector KK9474 
i008:  HIGH word of double-word connector KK9474 
-32768 to 32767 
Ind: 8 
FS=0 
Type: I2 
P052 = 2 
P051 = 40 
offline 