pdf renderer c# : How to add jpg to pdf file Library control API .net azure html sharepoint OPI_simoreg_DC_0707_en67-part1923

SIEMENS AG    6RX1700-0AD76 
12-21 
SIMOREG DC-MASTER    Operating Instructions 
Connector 
Description 
Normalization 
Function 
diag., Sheet 
K9352 
I component  
16384  =
100% 
B185 
K9353 
Output PI controller before limitation 
16384  =
100% 
B185 
K9354 
Output PI controller after limitation 
16384  =
100% 
B185 
K9355 
Positive limit for the output of the PI controller 
16384  =
100% 
B185 
K9356 
Positive limit for the output of the PI controller (K9355)  -1 
16384  =
100% 
B185 
K9357 
Negative limit for the output of the PI controller 
16384  =
100% 
B185 
Technology software S00: PI controller 7      [SW 1.8 and later] 
FB266 
K9360 
Input quantity filtered  
16384  =
100% 
B186 
K9361 
P component  
16384  =
100% 
B186 
K9362 
I component  
16384  =
100% 
B186 
K9363 
Output PI controller before limitation 
16384  =
100% 
B186 
K9364 
Output PI controller after limitation 
16384  =
100% 
B186 
K9365 
Positive limit for the output of the PI controller 
16384  =
100% 
B186 
K9366 
Positive limit for the output of the PI controller (K9365)  -1 
16384  =
100% 
B186 
K9367 
Negative limit for the output of the PI controller 
16384  =
100% 
B186 
Technology software S00: PI controller 8      [SW 1.8 and later] 
FB267 
K9370 
Input quantity filtered  
16384  =
100% 
B187 
K9371 
P component  
16384  =
100% 
B187 
K9372 
I component  
16384  =
100% 
B187 
K9373 
Output PI controller before limitation 
16384  =
100% 
B187 
K9374 
Output PI controller after limitation 
16384  =
100% 
B187 
K9375 
Positive limit for the output of the PI controller 
16384  =
100% 
B187 
K9376 
Positive limit for the output of the PI controller (K9375)  -1 
16384  =
100% 
B187 
K9377 
Negative limit for the output of the PI controller 
16384  =
100% 
B187 
Technology software S00: PI controller 9      [SW 1.8 and later] 
FB268 
K9380 
Input quantity filtered  
16384  =
100% 
B188 
K9381 
P component  
16384  =
100% 
B188 
K9382 
I component  
16384  =
100% 
B188 
K9383 
Output PI controller before limitation 
16384  =
100% 
B188 
K9384 
Output PI controller after limitation 
16384  =
100% 
B188 
K9385 
Positive limit for the output of the PI controller 
16384  =
100% 
B188 
K9386 
Positive limit for the output of the PI controller (K9385)  -1 
16384  =
100% 
B188 
K9387 
Negative limit for the output of the PI controller 
16384  =
100% 
B188 
Technology software S00: PI controller 10      [SW 1.8 and later] 
FB269 
K9390 
Input quantity filtered  
16384  =
100% 
B189 
K9391 
P component  
16384  =
100% 
B189 
K9392 
I component  
16384  =
100% 
B189 
K9393 
Output PI controller before limitation 
16384  =
100% 
B189 
K9394 
Output PI controller after limitation 
16384  =
100% 
B189 
K9395 
Positive limit for the output of the PI controller 
16384  =
100% 
B189 
K9396 
Positive limit for the output of the PI controller (K9395)  -1 
16384  =
100% 
B189 
K9397 
Negative limit for the output of the PI controller 
16384  =
100% 
B189 
Technology software S00: Derivative/delay elements 
K9400 
Derivative/delay element 1 output 
[SW 1.8 and later]  FB 270
16384  =
100% 
B156 
K9401 
Derivative/delay element 2 output 
[SW 1.8 and later]  FB 271
16384  =
100% 
B156 
How to add jpg to pdf file - insert images into PDF in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Sample C# code to add image, picture, logo or digital photo into PDF document page using PDF page editor control
adding image to pdf form; add picture to pdf reader
How to add jpg to pdf file - VB.NET PDF insert image library: insert images into PDF in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide VB.NET Programmers How to Add Images in PDF Document
add photo to pdf reader; how to add image to pdf form
12-22 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
Connector 
Description 
Normalization 
Function 
diag., Sheet 
K9402 
Derivative/delay element 3 output 
[SW 1.8 and later]  FB 272
16384  =
100% 
B156 
K9403 
Derivative/delay element 4 output 
[SW 1.8 and later]  FB 273
16384  =
100% 
B156 
K9404 
Derivative/delay element 5 output 
[SW 1.8 and later]  FB 274
16384  =
100% 
B157 
K9405 
Derivative/delay element 6 output 
[SW 1.8 and later]  FB 275
16384  =
100% 
B157 
K9406 
Derivative/delay element 7 output 
[SW 1.8 and later]  FB 276
16384  =
100% 
B157 
K9407 
Derivative/delay element 8 output 
[SW 1.8 and later]  FB 277
16384  =
100% 
B157 
K9408 
Derivative/delay element 9 output 
[SW 1.8 and later]  FB 278
16384  =
100% 
B158 
K9409 
Derivative/delay element 10 output 
[SW 1.8 and later]  FB 279
16384  =
100% 
B158 
Technology software S00: Characteristic blocks 
K9410 
Output characteristic block 4 
[SW 1.8 and later]  FB 280
16384  =
100% 
B160 
K9411 
Output characteristic block 5 
[SW 1.8 and later]  FB 281
16384  =
100% 
B160 
K9412 
Output characteristic block 6 
[SW 1.8 and later]  FB 282
16384  =
100% 
B160 
K9413 
Output characteristic block 7 
[SW 1.8 and later]  FB 283
16384  =
100% 
B160 
K9414 
Output characteristic block 8 
[SW 1.8 and later]  FB 284
16384  =
100% 
B160 
K9415 
Output characteristic block 9 
[SW 1.8 and later]  FB 285
16384  =
100% 
B160 
Technology software S00: Multiplier 
K9430 
Output multiplier 5 
[SW 1.8 and later]  FB 290
16384  =
100% 
B130 
K9431 
Output multiplier 6 
[SW 1.8 and later]  FB 291
16384  =
100% 
B130 
K9432 
Output multiplier 7 
[SW 1.8 and later]  FB 292
16384  =
100% 
B130 
K9433 
Output multiplier 8 
[SW 1.8 and later]  FB 293
16384  =
100% 
B130 
K9434 
Output multiplier 9 
[SW 1.8 and later]  FB 294
16384  =
100% 
B130 
K9435 
Output multiplier 10 
[SW 1.8 and later]  FB 295
16384  =
100% 
B130 
K9436 
Output multiplier 11 
[SW 1.8 and later]  FB 296
16384  =
100% 
B130 
K9437 
Output multiplier 12 
[SW 1.8 and later]  FB 297
16384  =
100% 
B130 
S00 technology software: Software counter 
K9441 
Minimum value for software counter 
[SW 1.9 and later]  FB 89
=
B196 
K9442 
Maximum value for software counter 
[SW 1.9 and later]  FB 89
=
B196 
K9443 
Setting value for software counter 
[SW 1.9 and later]  FB 89
=
B196 
K9444 
Start value for software counter 
[SW 1.9 and later]  FB 89
=
B196 
K9445 
Software counter output 
[SW 1.9 and later]  FB 89
=
B196 
Technology software S00: Multiplexer 
K9450 
Output multiplexer 1 
[SW 1.8 and later]  FB 86
16384  =
100% 
B195 
K9451 
Output multiplexer 2 
[SW 1.8 and later]  FB 87
16384  =
100% 
B195 
K9452 
Output multiplexer 3 
[SW 1.8 and later]  FB 88
16384  =
100% 
B195 
Technology software S00: Averagers 
K9455 
Output averager 1 
[SW 1.8 and later]  FB 16
16384  =
100% 
B139 
K9456 
Output averager 2 
[SW 1.8 and later]  FB 17 16384  =
100% 
B139 
K9457 
Output averager 3 
[SW 1.8 and later]  FB 18
16384  =
100% 
B139 
K9458 
Output averager 4 
[SW 1.8 and later]  FB 19
16384  =
100% 
B139 
Technology software S00: Minimum selections, Maximum selections 
K9460 
Output Maximum selection 2 
[SW 1.8 and later]  FB 174
16384  =
100% 
B140 
K9461 
Output Maximum selection 3 
[SW 1.8 and later]  FB 175
16384  =
100% 
B140 
K9462 
Output Maximum selection 4 
[SW 1.8 and later]  FB 176
16384  =
100% 
B140 
K9463 
Output Minimum selection 2 
[SW 1.8 and later]  FB 177
16384  =
100% 
B140 
VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.
Add necessary references page As PDFPage = doc.GetPage(0) ' Convert the first PDF page to page.ConvertToImage(ImageType.JPEG, Program.RootPath + "\\Output.jpg").
add signature image to pdf; add jpg to pdf document
C# PDF Convert to Jpeg SDK: Convert PDF to JPEG images in C#.net
example, this C#.NET PDF to JPEG converter library will name the converted JPEG image file Output.jpg. Convert PDF to JPEG Using C#.NET. Add necessary references
add jpg to pdf acrobat; how to add image to pdf reader
SIEMENS AG    6RX1700-0AD76 
12-23 
SIMOREG DC-MASTER    Operating Instructions 
Connector 
Description 
Normalization 
Function 
diag., Sheet 
K9464 
Output Minimum selection 3 
[SW 1.8 and later]  FB 178
16384  =
100% 
B140 
K9465 
Output Minimum selection 4 
[SW 1.8 and later]  FB 179
16384  =
100% 
B140 
Technology software S00: position fixed value, position actual value, positional deviation 
KK9471 
Position fixed value1 
[SW 2.0 and later]  FB 54
=
B152 
KK9472 
Position fixed value2 
[SW 2.0 and later]  FB 54
=
B152 
KK9473 
Position fixed value3 
[SW 2.0 and later]  FB 54
=
B152 
KK9474 
Position fixed value4 
[SW 2.0 and later]  FB 54
=
B152 
KK9481 
Position actual value 1 
[SW 2.0 and later]  FB 54
=
B152 
KK9482 
Position actual value 2 
[SW 2.0 and later]  FB 54
=
B152 
KK9483 
Positional deviation 
[SW 2.0 and later]  FB 54
=
B152 
K9484 
Positional deviation limited 
[SW 2.0 and later]  FB 54
=
B152 
Technology software S00: root extractor 
KK9485 
Root extractor output 
[SW 2.0 and later]  FB 58
16384  =
100% 
B153 
S00 technology software: Adders / subtracters for double-word connectors 
KK9490 
Output of 1
st
adder / subtracter  
[SW 1.9 and later]  FB 48
16384*65536  =
100% 
B151 
K9491 
Output of 1
st
adder / subtracter (limited) 
[SW 1.9 and later]  FB 48
16384  =
100%/65536 
B151 
KK9492 
Output of 2
nd
adder / subtracter 
[SW 1.9 and later]  FB 49
16384*65536  =
100% 
B151 
K9493 
Output of 2
nd
adder / subtracter (limited) 
[SW 1.9 and later]  FB 49
16384  =
100%/65536 
B151 
S00 technology software: Connector type converters 
KK9498 
Output of 1
st
connector type converter 
[SW 1.9 and later]  FB 298
16384*65536  =
100% 
B151 
KK9499 
Output of 2
nd
connector type converter 
[SW 1.9 and later]  FB 299
16384*65536  =
100% 
B151 
Technology software S00: Fixed values  
[SW 1.8 and later] 
K9501 
Fixed value 1 (U099.01)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9502 
Fixed value 2 (U099.02)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9503 
Fixed value 3 (U099.03)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9504 
Fixed value 4 (U099.04)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9505 
Fixed value 5 (U099.05)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9506 
Fixed value 6 (U099.06)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9507 
Fixed value 7 (U099.07)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9508 
Fixed value 8 (U099.08)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9509 
Fixed value 9 (U099.09)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9510 
Fixed value 10 (U099.10)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9511 
Fixed value 11 (U099.11)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9512 
Fixed value 12 (U099.12)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9513 
Fixed value 13 (U099.13)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9514 
Fixed value 14 (U099.14)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9515 
Fixed value 15 (U099.15)  
[SW 1.8 and later] 16384  =
100% 
B110 
K9516 
Fixed value 16 (U099.16)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9517 
Fixed value 17 (U099.17)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9518 
Fixed value 18 (U099.18)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9519 
Fixed value 19 (U099.19)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9520 
Fixed value 20 (U099.20)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9521 
Fixed value 21 (U099.21)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9522 
Fixed value 22 (U099.22)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9523 
Fixed value 23 (U099.23)  
[SW 1.8 and later]
16384  =
100% 
B110 
C# Image Convert: How to Convert Adobe PDF to Jpeg, Png, Bmp, &
C# DLLs for PDF Conversion to Images. Add necessary references to your C# project: This demo code convert PDF file all pages to jpg images.
add jpg to pdf preview; adding an image to a pdf form
C# Image Convert: How to Convert Dicom Image File to Raster Images
Add necessary references to your C# project RasterEdge.XDoc.PDF.dll. inputFilePath = @"C:\input.dcm"; String outputFilePath = @"C:\output.jpg"; // Convert dicom
how to add an image to a pdf file; how to add an image to a pdf in preview
12-24 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
Connector 
Description 
Normalization 
Function 
diag., Sheet 
K9524 
Fixed value 24 (U099.24)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9525 
Fixed value 25 (U099.25)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9526 
Fixed value 26 (U099.26)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9527 
Fixed value 27 (U099.27)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9528 
Fixed value 28 (U099.28)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9529 
Fixed value 29 (U099.29)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9530 
Fixed value 30 (U099.30)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9531 
Fixed value 31 (U099.31)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9532 
Fixed value 32 (U099.32)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9533 
Fixed value 33 (U099.33)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9534 
Fixed value 34 (U099.34)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9535 
Fixed value 35 (U099.35)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9536 
Fixed value 36 (U099.36)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9537 
Fixed value 37 (U099.37)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9538 
Fixed value 38 (U099.38)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9539 
Fixed value 39 (U099.39)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9540 
Fixed value 40 (U099.40)  
[SW 1.8 and later] 16384  =
100% 
B110 
K9541 
Fixed value 41 (U099.41)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9542 
Fixed value 42 (U099.42)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9543 
Fixed value 43 (U099.43)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9544 
Fixed value 44 (U099.44)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9545 
Fixed value 45 (U099.45)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9546 
Fixed value 46 (U099.46)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9547 
Fixed value 47 (U099.47)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9548 
Fixed value 48 (U099.48)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9549 
Fixed value 49 (U099.49)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9550 
Fixed value 50 (U099.50)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9551 
Fixed value 51 (U099.51)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9552 
Fixed value 52 (U099.52)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9553 
Fixed value 53 (U099.53)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9554 
Fixed value 54 (U099.54)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9555 
Fixed value 55 (U099.55)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9556 
Fixed value 56 (U099.56)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9557 
Fixed value 57 (U099.57)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9558 
Fixed value 58 (U099.58)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9559 
Fixed value 59 (U099.59)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9560 
Fixed value 60 (U099.60)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9561 
Fixed value 61 (U099.61)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9562 
Fixed value 62 (U099.62)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9563 
Fixed value 63 (U099.63)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9564 
Fixed value 64 (U099.64)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9565 
Fixed value 65 (U099.65)  
[SW 1.8 and later] 16384  =
100% 
B110 
K9566 
Fixed value 66 (U099.66)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9567 
Fixed value 67 (U099.67)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9568 
Fixed value 68 (U099.68)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9569 
Fixed value 69 (U099.69)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9570 
Fixed value 70 (U099.70)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9571 
Fixed value 71 (U099.71)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9572 
Fixed value 72 (U099.72)  
[SW 1.8 and later]
16384  =
100% 
B110 
C# Create PDF from images Library to convert Jpeg, png images to
images.Add(new Bitmap(Program.RootPath + "\\" 1.jpg")); images.Add(new Bitmap(Program.RootPath + "\\" 1.png")); / Build a PDF document with
pdf insert image; add a jpg to a pdf
C# WPF PDF Viewer SDK to convert and export PDF document to other
Highlight Text. Add Text. Add Text Box. Drawing Markups. Add Stamp Annotation. image file formats with high quality, support converting PDF to PNG, JPG, BMP and
attach image to pdf form; add picture to pdf document
SIEMENS AG    6RX1700-0AD76 
12-25 
SIMOREG DC-MASTER    Operating Instructions 
Connector 
Description 
Normalization 
Function 
diag., Sheet 
K9573 
Fixed value 73 (U099.73)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9574 
Fixed value 74 (U099.74)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9575 
Fixed value 75 (U099.75)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9576 
Fixed value 76 (U099.76)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9577 
Fixed value 77 (U099.77)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9578 
Fixed value 78 (U099.78)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9579 
Fixed value 79 (U099.79)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9580 
Fixed value 80 (U099.80)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9581 
Fixed value 81 (U099.81)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9582 
Fixed value 82 (U099.82)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9583 
Fixed value 83 (U099.83)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9584 
Fixed value 84 (U099.84)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9585 
Fixed value 85 (U099.85)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9586 
Fixed value 86 (U099.86)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9587 
Fixed value 87 (U099.87)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9588 
Fixed value 88 (U099.88)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9589 
Fixed value 89 (U099.89)  
[SW 1.8 and later] 16384  =
100% 
B110 
K9590 
Fixed value 90 (U099.90)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9591 
Fixed value 91 (U099.91)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9592 
Fixed value 92 (U099.92)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9593 
Fixed value 93 (U099.93)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9594 
Fixed value 94 (U099.94)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9595 
Fixed value 95 (U099.95)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9596 
Fixed value 96 (U099.96)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9597 
Fixed value 97 (U099.97)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9598 
Fixed value 98 (U099.98)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9599 
Fixed value 99 (U099.99)  
[SW 1.8 and later]
16384  =
100% 
B110 
K9600 
Fixed value 100 (U099.100)  
[SW 1.8 and later]
16384  =
100% 
B110 
General connectors 
K9801 
Alarm word 1 (= parameter r953) 
K9802 
Alarm word 2 (= parameter r954) 
K9803 
Alarm word 3 (= parameter r955) 
K9804 
Alarm word 4 (= parameter r956) 
K9805 
Alarm word 5 (= parameter r957) 
K9806 
Alarm word 6 (= parameter r958) 
K9807 
Alarm word 7 (= parameter r959) 
K9808 
Alarm word 8 (= parameter r960) 
K9811 
Fault number 1 (= parameter r947.01, current fault number) 
G189 
K9812 
Fault number 2 (= parameter r947.09, second last fault number) 
G189 
K9813 
Fault number 3 (= parameter r947.17, third last fault number) 
G189 
K9814 
Fault number 4 (= parameter r947.25, fourth last fault number) 
G189 
K9815 
Fault number 5 (= parameter r947.33) 
G189 
K9816 
Fault number 6 (= parameter r947.41) 
G189 
K9817 
Fault number 7 (= parameter r947.49) 
G189 
K9818 
Fault number 8 (= parameter r947.57) 
G189 
K9990 
Current total processor capacity utilization (C163/C165) (= parameter 
n009.01) 
C# PDF File Merge Library: Merge, append PDF files in C#.net, ASP.
Combine scanned images to PDF, such as tiff, jpg, png, gif, bmp, etc. Add necessary references: In addition, C# users can append a PDF file to the end of a
add jpeg to pdf; add image to pdf file acrobat
VB.NET PDF File Merge Library: Merge, append PDF files in vb.net
to combine various scanned images to PDF, such as tiff, jpg, png, gif Add necessary references: In addition, VB.NET users can append a PDF file to the end of a
add image to pdf acrobat; add photo to pdf
12-26 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
Connector 
Description 
Normalization 
Function 
diag., Sheet 
K9991 
Projected total processor capacity utilization (C163/C165) for line frequency 
=  65Hz  (= parameter n009.02) 
K9992 
Current total processor capacity (C163/C165) utilized by background 
routines (= parameter n009.03) 
K9993 
Current total processor capacity (C163/C165) utilized by routines in 
foreground cycle 4 (= parameter n009.04) 
K9994 
Current total processor capacity (C163/C165) utilized by routines in 
foreground cycle 2 (= parameter n009.05) 
K9995 
Current total processor capacity (C163/C165) utilized by routines in 
foreground cycle 1 (= parameter n009.06) 
SIEMENS AG    6RX1700-0AD76 
12-27 
SIMOREG DC-MASTER    Operating Instructions 
12.2  Binector list 
The states of binectors can be displayed via parameters r045 and P046. 
Binector 
Name, description 
Function 
diag., Sheet 
Fixed values 
B0000 
Fixed value 0 
G120 
B0001 
Fixed value 1 
G120 
Binary inputs, terminals 36 to 43 
B0010 
Status of terminal 36 
G110 
B0011 
Status of terminal 36, inverted 
G110 
B0012 
Status of terminal 37 
G110 
B0013 
Status of terminal 37, inverted 
G110 
B0014 
Status of terminal 38 
G110 
B0015 
Status of terminal 38, inverted 
G110 
B0016 
Status of terminal 39 
G110 
B0017 
Status of terminal 39, inverted 
G110 
B0018 
Status of terminal 40 
G111 
B0019 
Status of terminal 40, inverted 
G111 
B0020 
Status of terminal 41 
G111 
B0021 
Status of terminal 41, inverted 
G111 
B0022 
Status of terminal 42 
G111 
B0023 
Status of terminal 42, inverted 
G111 
B0024 
Status of terminal 43 
G111 
B0025 
Status of terminal 43, inverted 
G111 
B0032 
No meaning 
B0033 
No meaning 
B0034 
No meaning 
B0035 
No meaning 
Binary inputs, terminals 211 to 214 / motor interface 
B0040 
Status of terminal 211 / Brush length monitor (binary) (0=fault) 
G186 
B0041 
Status of terminal 211, inverted 
G186 
B0042 
Status of terminal 212 / Bearing condition monitor (binary) (1=fault) 
G186 
B0043 
Status of terminal 212, inverted 
G186 
B0044 
Status of terminal 213 / Motor fan monitor (binary) (0=fault) 
G186 
B0045 
Status of terminal 213, inverted 
G186 
B0046 
Status of terminal 214 / Motor temperature monitor (binary) (0=fault) 
G186 
B0047 
Status of terminal 214, inverted 
G186 
Analog inputs 
B0050 
Analog input, terminal 4:  1 = Open circuit (i  2 mA) 
G113 
B0051 
Analog input, terminal 6:  1 = Open circuit (i  2 mA) 
G113 
Pulse encoder evaluation 
B0052 
Fault in digital speed sensing circuit 
G145 
B0053 
Underflow of actual position value 
[SW 1.9 and later] 
This binector changes to 1 when connector KK0046 (actual position value extended in software to a 32-bit 
value) counts from value 8000 0000H (= –2
31
) to value 7FFF FFFFH (= +2
31
–1). 
Binector B0053 does not change back to 0 until connector KK0046 assumes a value other than 7FFF 
FFFFH (= +2
31
–1) again. 
G145 
12-28 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
Binector 
Name, description 
Function 
diag., Sheet 
B0054 
Overrflow of actual position value 
[SW 1.9 and later]  
This binector changes to 1 when connector KK0046 (actual position value extended in software to a 32-bit 
value) counts from value 7FFF FFFFH (= +2
31
–1) to value 8000 0000H (= –2
31
). 
Binector B0054 does not change back to 0 until connector KK0046 assumes a value other than 8000 0000H 
(= –2
31
) again. 
G145 
Evaluation of the pulse encoder board SBP 
B0055 
Position acquisition of SBP, underflow 
[SW 2.0 and later]  Z120 
B0056 
Position acquisition of SBP, overflow 
[SW 2.0 and later]  Z120 
Monitoring of the armature currents 
B0057 
1 = Commutation failure or overcurrent has occurred 
[SW 2.0 and later]  G162 
Status word 1 
B0100 
Stat.word 1, bit 0:   0=not ready to switch on, 1=ready to switch on 
G182 
B0101 
Stat.word 1, bit 0 inverted 
G182 
B0102 
Stat.word 1, bit 1:   0=not ready, 1=ready (pulses disabled) 
G182 
B0103 
Stat.word 1, bit 1 inverted 
G182 
B0104 
Stat.word 1, bit 2:   0=pulses disabled, 1=Run (output terminals energized) 
G182 
B0105 
Stat.word 1, bit 2 inverted 
G182 
B0106 
Stat.word 1, bit 3:   0=no active fault, 1=active fault (pulses disabled) 
G182 
B0107 
Stat.word 1, bit 3 inverted 
G182 
B0108 
Stat.word 1, bit 4:   0=OFF2 active, 1=no active OFF2 
G182 
B0109 
Stat.word 1, bit 4 inverted 
G182 
B0110 
Stat.word 1, bit 5:   0=OFF3 active, 1=no active OFF3 
G182 
B0111 
Stat.word 1, bit 5 inverted 
G182 
B0112 
Stat.word 1, bit 6:   0=no starting lockout (unit can be switched on), 1=starting lockout active 
G182 
B0113 
Stat.word 1, bit 6 inverted 
G182 
B0114 
Stat.word 1, bit 7:   0=no active alarm, 1=alarm active 
G182 
B0115 
Stat.word 1, bit 7 inverted 
G182 
B0116 
Stat.word 1, bit 8:   0=setp./act. val. deviation detected, 1=no setp./act. val. deviation 
G182 
B0117 
Stat.word 1, bit 8 inverted 
G182 
B0120 
Stat.word 1, bit 10:   0=comparison setpoint not reached, 1=comparison setpoint reached 
G182 
B0121 
Stat.word 1, bit 10 inverted 
G182 
B0122 
Stat.word 1, bit 11:   0=undervoltage fault not active, 1=undervoltage fault active 
G182 
B0123 
Stat.word 1, bit11 inverted 
G182 
B0124 
Stat.word 1, bit 12:   0=main contactor request not active, 1=request to energize main contactor active 
G182 
B0125 
Stat.word 1, bit 12 inverted 
G182 
B0126 
Stat.word 1, bit 13:   0=ramp-function generator not active, 1=ramp-function generator active 
G182 
B0127 
Stat.word 1, bit 13 inverted 
G182 
B0128 
Stat.word 1, bit 14:   0=negative speed setpoint, 1=positive speed setpoint 
G182 
B0129 
Stat.word 1, bit 14 inverted 
G182 
Status word 2 
B0136 
Stat.word 2, bit 18:   0=overspeed, 1=no overspeed 
G183 
B0137 
Stat.word 2, bit 18 inverted 
G183 
B0138 
Stat.word 2, bit 19:   0=no external fault 1 active, 1=external fault 1 active 
G183 
B0139 
Stat.word 2, bit 19 inverted 
G183 
B0140 
Stat.word 2, bit 20:   0=no external fault 2 active, 1=external fault 2 active 
G183 
B0141 
Stat.word 2, bit 20 inverted 
G183 
B0142 
Stat.word 2, bit 21:   0=no external alarm active, 1=external alarm active 
G183 
SIEMENS AG    6RX1700-0AD76 
12-29 
SIMOREG DC-MASTER    Operating Instructions 
Binector 
Name, description 
Function 
diag., Sheet 
B0143 
Stat.word 2, bit 21 inverted 
G183 
B0144 
Stat.word 2, bit 22:   0=no overload alarm active, 1=overload alarm active 
G183 
B0145 
Stat.word 2, bit 22 inverted 
G183 
B0146 
Stat.word 2, bit 23:   0=no overtemperature fault active, 1=overtemperature fault active 
G183 
B0147 
Stat.word 2, bit 23 inverted 
G183 
B0148 
Stat.word 2, bit 24:   0=no overtemperature alarm active, 1=overtemperature alarm active 
G183 
B0149 
Stat.word 2, bit 24 inverted 
G183 
B0150 
Stat.word 2, bit 25:   0=no motor overtemperature alarm active, 1=motor overtemperature alarm active 
G183 
B0151 
Stat.word 2, bit 25 inverted 
G183 
B0152 
Stat.word 2, bit 26:   0=no motor overtemperature fault active, 1=motor overtemperature fault active 
G183 
B0153 
Stat.word 2, bit 26 inverted 
G183 
B0156 
Stat.word 2, bit 28:   0=no motor blocked fault active, 1=motor blocked fault active 
G183 
B0157 
Stat.word 2, bit 28 inverted 
G183 
Messages 
B0160 
0=AUS1 or AUS3 active, 1=no  AUS1 and no AUS3 is pending 
G180 
B0161 
B0160 inverted 
G180 
B0164 
1 = n < n
min 
[SW 1.4 and later] 
G187 
B0165 
B0164 inverted
[SW 1.4 and later] 
G187 
B0166 
1 = Voltage at power section is active (armature and field supply)
[SW 1.4 and later] 
B0167 
B0166 inverted
[SW 1.4 and later] 
B0168 
1 = E-Stop is active
[SW 1.4 and later] 
G117 
B0169 
B0168 inverted
[SW 1.4 and later] 
G117 
B0172 
Output of "Setpoint-actual value deviation 2" signal  
[SW 1.9 and later]  G187 
B0173 
B0172 inverted 
[SW 1.9 and later]  G187 
Acknowledgement of fault codes 
B0179 
Acknowledgement of control word or P key on PMU (pulse) 
G180 
Motor interface 
B0180 
1 = Monitoring brush length (Terminal 211=0) has responded, condition for A025 or F025 fulfilled 
G186 
B0181 
1 = Monitoring bearing state (terminal 212=1) has responded, condition for A026 or F026 fulfilled 
G186 
B0182 
1 = Monitoring motor fan (terminal 213=0) has responded, condition for A027 or F027 fulfilled 
G186 
B0183 
1 = Monitoring motor temperature (terminal 213=0) has responded, condition for A028 or F028 fulfilled 
G186 
Temperature sensor inputs 
[SW 1.6 and later] 
B0184 
1=Alarm motor temperature 1  
G185 
B0185 
1=Alarm motor temperature 2  
G185 
Alarms  
[SW 1.6 and later] 
B0186 
1=Alarm A037 (I2t motor) is pending  
B0187 
1=Alarm A039 (I2t power section) is pending  
B0188 
1=Alarm A067 (heat sink temperature) is pending  
B0189 
1=Alarm A067 (device fan) is pending  
Torque limitation, current limitation, current controller, armature gating unit 
B0190 
0 = pulsating current, 1 = continuous current 
[SW 2.0 and later]  G162 
B0192 
Speed limitation controller: Positive speed limit reached 
[SW 1.8 and later]  G160 
B0193 
Speed limitation controller: Negative speed limit reached 
[SW 1.8 and later]  G160 
B0194 
Current limitation: Positive current limit reached 
[SW 1.8 and later]  G161 
12-30 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
Binector 
Name, description 
Function 
diag., Sheet 
B0195 
Current limitation: Negative current limit reached 
[SW 1.8 and later]  G161 
B0196 
α
G
limit reached 
[SW 1.8 and later] 
G163 
B0197 
α
W
limit reached 
[SW 1.8 and later] 
G163 
B0198 
Any positive limit (speed, torque, armature, α
G
) reached 
[SW 2.0 and later] 
B0199 
Any positive limit (speed, torque, armature, α
W
) reached 
[SW 2.0 and later] 
B0200 
Current limitation active 
G161 
B0201 
Speed limiting controller active 
G160 
B0202 
Upper torque limitation active 
G160 
B0203 
Lower torque limitation active 
G160 
B0204 
Torque or current limitation active or current controller at limitation 
G163 
Speed controller 
B0205 
Speed controller enabling by sequencing control 
G152 
Setpoint processing, ramp-function generator 
B0206 
Limitation after ramp-function generator (setpoint limitation) has responded 
G137 
B0207 
Ramp-function generator output = 0  (y = 0) 
G136 
B0208 
Ramp-function generator, ramp-up 
G136 
B0209 
Ramp-function generator, ramp-down 
G136 
B0210 
1 = no direction of rotation enabled 
G135 
B0211 
Ramp-function generator: Enable setpoint (1 = setpoint enabled) 
[SW 1.6 and later]  G136 
Limit-value monitor for field current 
B0215 
Limit-value signal I
f
< I
f min
(see P394, P395) 
G188 
B0216 
Limit-value signal I
f
< I
f x
(see P398, P399) 
G188 
Armature gating unit  
B0220 
Enabled torque direction for parallel drive 
G163 
B0221 
1 = Torque direction I active 
[SW 2.1 and later]  G163 
B0222 
1 = Torque direction II active 
[SW 2.1 and later]  G163 
B0225 
1 = active paralleling master 
[SW 2.1 and later]  G195 
B0230 
1 = No torque direction requested 
[SW 2.1 and later]  G163 
B0231 
1 = Torque direction I requested 
[SW 2.1 and later]  G163 
B0232 
1 = Torque direction II requested 
[SW 2.1 and later]  G163 
Motorized potentiometer 
B0240 
Motorized potentiometer output = 0  (y = 0) 
G126 
B0241 
Ramp-up/ramp-down finished (y = x) 
G126 
Brake control 
B0250 
Brake control (1=close brake, 0=release brake) 
G140 
B0251 
1=auxiliaries ON, 0=auxiliaries OFF 
s.Chap. 9.10 
B0252 
1=device fan on, 0=device fan off 
[SW 1.5 and later]   
B0255 
B0250 inverted
[SW 1.4 and later]  G140 
B0256 
B0251 inverted
[SW 1.5 and later]   
Field reversal 
B0260 
1=Close field contactor 1 (control command for one contactor for connection of positive field direction) 
G200 
B0261 
1=Close field contactor 2 (control command for one contactor for connection of negative field direction) 
G200 