pdf renderer c# : Add photo to pdf preview Library control component .net azure web page mvc OPI_simoreg_DC_0707_en7-part1926

Siemens AG    6RX1700-0AD76 
5-13 
SIMOREG DC-MASTER    Operating Instructions 
5.1.11  Converters: 3AC 400V and 575V, 400A to 600A, 4Q 
10
10
s
XF1
XF2
V7
V8
625
602
318
268
230
120
160
35
133
4U1
4V1
4W1
39
1U1
1V1
1D1
(1C1)
1C1
(1D1)
1W1
V1
V3
V5
T2
V4
V6
V2
19
X300
T3
R100
585
100 
1)
100 
1)
for M8
for M10
306.5
179.7
123.7
47.5
47.5
47.5
47.5
for M10
1) Minimum clearance for air circulation
    An adequate cooling air supply must be provided 
1U1, 1V1, 1W1, 1C1, 1D1 = 25 Nm
= 50 Nm
Tightening torque for customer connections:
21U1, 1V1, 1W1 = 2 x 150 mm
1C1, 1D1 = 2 x 185 mm2
Max. conductor size for cables with cable eye in accordance with DIN 46234:
Add photo to pdf preview - insert images into PDF in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Sample C# code to add image, picture, logo or digital photo into PDF document page using PDF page editor control
add an image to a pdf; add a jpeg to a pdf
Add photo to pdf preview - VB.NET PDF insert image library: insert images into PDF in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide VB.NET Programmers How to Add Images in PDF Document
how to add image to pdf reader; how to add an image to a pdf file
5-14
Siemens AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
5.1.12  Converters: 3AC 400V, 575V, and 690V, 760A to 850A, 4Q 
XF1
XF2
1U1
1V1
1W1
30
33
30
30
30
30
205
162
119
76
139
510
55
85
700
268
230
19
150
350
58
677
10
192
1C1
(1D1)
T2 T3
V1 V3V5
V8
V4V6V2
V7
X300
1D1
(1C1)
12
275
40
660
100 
1)
100 
1)
for M12
Lifting lug Ø20
for M8
for M10
1) Minimum clearance for air circulation
    An adequate cooling air supply must be provided 
1U1, 1V1, 1W1, 1C1, 1D1 = 44 Nm
= 50 Nm
Tightening torque for customer connections:
Max. conductor size for cables with cable eye
in accordance with DIN 46234: 4 x 150 mm2
C# PDF remove image library: remove, delete images from PDF in C#.
Support removing vector image, graphic picture, digital photo, scanned signature, logo, etc. Remove Image from PDF Page Using C#. Add necessary references:
adding images to pdf; add image to pdf
VB.NET PDF remove image library: remove, delete images from PDF in
Support removing vector image, graphic picture, digital photo, scanned signature, logo, etc. VB.NET: Remove Image from PDF Page. Add necessary references:
add image to pdf preview; add jpeg signature to pdf
Siemens AG    6RX1700-0AD76 
5-15 
SIMOREG DC-MASTER    Operating Instructions 
5.1.13  Converters: 3AC 400V, 460V, 575V, 690V, and 830V, 950A to 1200A, 4Q 
20
10
V1
V3
V5
4U14V14W1
XF1
XF2
30
66
122
198
254
330
406
394
30
140
310
150
194
410
320
45
780
767
717
740
1U1
1V1
1W1
1D1
(1C1)
1C1
(1D1)
F4
F6
F2
R100
R100
V4
V6
V2
T2
T3
V7V8
F1
F3
F5
362
350
100 
1)
100 
1)
15
155
30
30
30
30
1U1
s
X300
for M10
Lifting lug Ø20
for M12
for M12
1) Minimum clearance for air circulation
    An adequate cooling air supply must be provided 
1U1, 1V1, 1W1, 1C1, 1D1 = 44 Nm
= 60 Nm
Tightening torque for customer connections:
 max. conductor size for cables withcable eye
in accordance with DIN 46234: 4 x 150 mm2
VB.NET PDF copy, paste image library: copy, paste, cut PDF images
to copy, paste and cut vector image, graphic picture, digital photo, scanned signature VB.NET DLLs: Copy, Paste, Cut Image in PDF Page. Add necessary references:
add picture to pdf reader; add photo to pdf preview
5-16
Siemens AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
5.1.14  Converters: 3AC 400V, 575V, 690V, and 830V, 1500A to 2000A, 575V/2200A  
4Q 
10
1U1
1V1
1W1
1D1
(1C1)
1C1
(1D1)
347
40
40
205
63
40
30
35
313
40
171
40
450
360
855
880
304
433
260
500
30
45
4U1
4V1
4W1
V14
V16
V12
V21
V23
V25
V24
V26
V22
V11
V13
V15
T2
T3
XF1
XF2
T2
T3
840
150 
1)
160 
1)
2)
433
235
158
1W1
Siemens AG    6RX1700-0AD76 
5-17 
SIMOREG DC-MASTER    Operating Instructions 
5.1.15  Converters: 3AC 400V / 3000A, 3AC 575V / 2800A, 3AC 690V / 2600A,  
3AC 950V / 2200A  4Q 
10
1U1
1V1
1W1
1D1
(1C1)
1C1
(1D1)
30
313
40
171
40
450
360
855
880
260
433
500
30
45
4U1
4V1
4W1
V14
V16
V12
V24
V26
V22
V11
V13
V15
F141
F142
F161
F162
F121
F122
F111
F112
F131
F132
F151
F152
840
150 
1)
160 
1)
2)
418
240
155
1W1
880
58,5
125
XF1,XF2
V21
V23
V25
T2 T3
3)
10
332
47
40
47
35
35
40 
190
35
35
35
35
48
for M10
for M12
for M12
for M12
View of rear thyristor level
Front view without doors
Customer terminals
Cable duct
Lifting lug 
Ø
22
1) Minimum clearance for air circulation, customer 
    connection and replacaement of fan. An adequate
    cooling air supply must be provided
1U1, 1V1, 1W1, 1C1, 1D1 = 44 Nm
= 60 Nm
Tightening torque for customer connections:
2) Remove transport cover by undoing 6 M6 
    hexagon head screws before start-up
Customer terminals
1U1, 1V1, 1W1: copper bus 2x100x10 for M12x50
1C1, 1D1: copper bus 2x80x10 for M12x50
      : copper bus 120x10 for M12x40
3) Insulation of mains terminals U1, V1, W1
5-18
Siemens AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
5.2  Dimension diagrams of the devices with additional cable 
connections on the top of the device 
5.2.1  Converters: 3AC 460V, 60A to 125A, 1Q 
s
X300
37
1U1
10
1D1
1V1
1C1
1W1
1U1
1D1
1V1
1C1
1W1
48,5
37
48
48
37
63,5
37
48
48
265
230
17,5
385
12,5
15
159
138
366
90
10
350
313
100 
1)
100 
1)
301,5
XF1
XF2
for M8
for M6
1) Minimum clearance for air circulation
    An adequate cooling air supply must be provided 
1U1, 1V1, 1W1, 1C1, 1D1 = 13 Nm
= 25 Nm
Tightening torque for customer connections:
Max. conductor size for cables with cable eye
in accordance with DIN 46234: 2 x 95 mm2
Siemens AG    6RX1700-0AD76 
5-19 
SIMOREG DC-MASTER    Operating Instructions 
5.2.2  Converters: 3AC 460V, 210A to 280A, 1Q 
s
X300
37
1U1
10
1D1
1V1
1C1
1W1
1U1
1D1
1V1
1C1
1W1
48,5
37
48
48
37
63,5
37
48
48
265
230
17,5
385
12,5
15
159
138
366
90
10
350
313
100 
1)
100 
1)
301,5
XF1
XF2
for M8
17.5
12.5
for M6
1) Minimum clearance for air circulation
    An adequate cooling air supply must be provided 
1U1, 1V1, 1W1, 1C1, 1D1 = 13 Nm
= 25 Nm
Tightening torque for customer connections:
Max. conductor size for cables with cable eye
in accordance with DIN 46234: 2 x 95 mm2
5-20
Siemens AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
5.2.3  Converters: 3AC 460V, 450A to 600A, 1Q 
318
585
100 
1)
100 
1)
10
604
602
268
230
133
19
39
47,5
47,5
47,5
47,5
47,5
47,5
47,5
47,5
39
1U1
1V1
1D1
1C1
1W1
1U1
1V1
1D1
1C1
1W1
XF1
XF2
625
21
10
125
164
35
306,5
155
139
s
X300
for M8
for M10
for M10
1) Minimum clearance for air circulation
    An adequate cooling air supply must be provided 
1U1, 1V1, 1W1, 1C1, 1D1 = 25 Nm
= 50 Nm
Tightening torque for customer connections:
Max. conductor size for cables with cable eye in accordance with DIN 46234:
21U1, 1V1, 1W1 = 2 x 150 mm
21C1, 1D1 = 2 x 185 mm
Siemens AG    6RX1700-0AD76 
5-21 
SIMOREG DC-MASTER    Operating Instructions 
5.2.4  Converters: 3AC 460V, 850A, 1Q 
10
12
130
147
192
355
700
360
33
30
76
30
119
30
162
30
205
30
30
651
111
30
275
40
A
677
12
230
19
268
X300
100 
1)
100 
1)
1U1
1V1
1W1
1D1
1C1
1U1
1V1
1W1
1D1
1C1
660 
Lifting lug Ø20
for M8
1) Minimum clearance for air circulation
    An adequate cooling air supply must be provided 
View A
for M12
for M10
1U1, 1V1, 1W1, 1C1, 1D1 = 44 Nm
= 50 Nm
Tightening torque for customer connections:
Max. conductor size for cables with cable eye
2in accordance with DIN 46234: 4 x 150 mm
5-22
Siemens AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
5.2.5  Converters: 3AC 460V, 60A to 125A, 4Q 
s
X300
37
1U1
10
1D1
(1C1)
1V1
1C1
(1D1)
1W1
1U1
1D1
(1C1)
1V1
1C1
(1D1)
1W1
48,5
37
48
48
37
63,5
37
48
48
265
230
17,5
385
12,5
15
159
138
366
90
10
350
313
100 
1)
100 
1)
301,5
XF1
XF2
for M8
for M6
1) Minimum clearance for air circulation
    An adequate cooling air supply must be provided 
1U1, 1V1, 1W1, 1C1, 1D1 = 13 Nm
= 25 Nm
Tightening torque for customer connections:
Max. conductor size for cables with cable eye
in accordance with DIN 46234: 2 x 95 mm2
Documents you may be interested