3-9 
GmbH
MIL-STD-1553 Specification Interpretation
MIL-STD-1553 Tutorial 
4.3.3.5.1.1 Sync 
The command sync waveform shall be 
an  invalid  Manchester  waveform  as 
shown on Figure 3-4. The width shall be 
three bit times, with the sync waveform 
being positive for the first one and one-
half bit times, and then negative for the 
following one and one-half bit times. If 
the  next  bit  following  the  sync 
waveform is a logic zero, then the last 
half of the sync waveform will have an 
apparent width of two clock periods due 
to the Manchester encoding. 
4.3.3.5.1.2 Remote Terminal Address 
The  next  five  bits  following  the  sync 
shall be the RT address. Each RT shall 
be assigned a unique address.  Decimal address 31 (11111) shall not be assigned as a unique 
address.  In addition to its unique address, a RT shall be assigned decimal address 31 (11111) 
as the common address, if the broadcast option is used. 
Command words are transmitted by the bus controller to remote terminals to instruct them to 
receive data, transmit data or perform some other operation.  Commands are sent to aid in 
data bus management, electrical control of an RT and standard data transfers.  Command 
words are only transmitted by the active bus controller. 
Each RT connected in a system is assigned a unique address.  With five available address 
bits, 2
allows for 32 unique addresses (0-31).  The remote terminal examines the address 
field of all incoming commands, and if the address field matches the RT address, that RT acts 
on the remainder of the command. RT address 31 (11111) was defined as the Broadcast RT. 
Individual RTs can enable or disable the processing of broadcast messages (a message to all 
system RTs), but no RT can respond to the broadcast message as a singular RT.  This limits 
the number of RTs in a 1553B bus system to 31, plus the broadcast address. 
Figure 3-4 – Command and Status Sync
Bit  
Stream 
Data          Word Sync 
Data 
Bit   
Bit 
+ VOLTS 
- VOLTS 
0
Specification
Interpretation
Pdf insert image - insert images into PDF in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Sample C# code to add image, picture, logo or digital photo into PDF document page using PDF page editor control
acrobat add image to pdf; how to add an image to a pdf file
Pdf insert image - VB.NET PDF insert image library: insert images into PDF in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide VB.NET Programmers How to Add Images in PDF Document
adding image to pdf form; add png to pdf preview
3-10 
GmbH
MIL-STD-1553 Specification Interpretation  
MIL-STD-1553 Tutorial 
4.3.3.5.1.3  Transmit/Receive 
The next bit following the remote terminal address shall be the T/R bit, which shall indicate 
the action required of the RT.  A logic zero shall indicate the RT is to receive, and a logic one 
shall indicate the RT is to transmit. 
4.3.3.5.1.4  Subaddress/Mode 
The next five bits following the T/R bit shall be utilized to indicate an RT Subaddress or use 
of  mode  control,  as  is  dictated  by  the  individual  terminal  requirements.    The 
Subaddress/mode values of 0 (00000) and 31 (11111) are reserved for special purposes, as 
specified in 4.3.3.5.1.7, and shall not be utilized for any other function. 
4.3.3.5.1.5  Data Word Count/Mode Code 
The next five bits following the Subaddress/Mode field shall be the quantity of data words to 
be either sent out or received by the RT or the optional mode code as specified in 4.3.3.5.1.7.  
A maximum of 32 data words may be transmitted or received in any one message block.  All 
1’s (11111) shall indicate a decimal count of 31, and all 0’s (00000) shall indicate a decimal 
count of 32. 
4.3.3.5.1.6  Parity 
The last bit in the word shall be used for parity over the preceding 16 bits.  Odd parity shall 
be utilized. 
The T/R bit indicates the action requested of the RT. This bit is set from the RT's perspective, 
meaning  a 1  bit  requests  the  RT to transmit  data,  a 0  requests  the  RT  to  receive  data 
following the command. 
A Subaddress is a function or area within the RT to which the command is being directed. 
The Subaddress directs the RT to a specific grouping of data to be transmitted onto the bus, 
or it indicates what the RT is to do with the data it is about to receive.  MIL-STD-1553B sets 
aside two special subaddresses: Subaddress 0 and Subaddress 31.  They are reserved for 
Mode code (or Mode commands).  
Mode commands are special messages that utilize the five-bit Word Count field as a Mode 
Code  field.  These  messages  are  sent  to  specific RTs  to  check  their  status,  control  their 
operation and manage the bus.  Mode commands exchange at most one data word, and may 
involve no data words at all. 
The Data Word Count/Mode Code is another dual function field, determined by the contents 
in the Subaddress/Mode field.  Up to 32 data words can be transmitted in a message. 
Parity checks for bit  errors during transmission. The  total number  of  bits for any word 
exchanged, excluding the sync bits and including the parity bit, should be odd. 
Specification
Interpretation
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
Page: Insert PDF Pages. |. Home ›› XDoc.PDF ›› VB.NET PDF: Insert PDF Page.
add image to pdf java; add an image to a pdf form
C# PDF Image Extract Library: Select, copy, paste PDF images in C#
PDF ›› C# PDF: Extract PDF Image. How to C#: Extract Image from PDF Document. Support PDF Image Extraction from a Page, a Region on a Page, and PDF Document.
how to add image to pdf; add photo to pdf reader
3-11 
GmbH
MIL-STD-1553 Specification Interpretation
MIL-STD-1553 Tutorial 
4.3.3.5.1.7 Optional Mode Control  
For  RTs  exercising  this  option  a 
Subaddress/mode code of 0 (00000) 
or  31  (11111)  shall  imply  that  the 
contents  of  the  data  word 
count/mode  code  field  are  to  be 
decoded  as  a  five  bit  mode 
command.    The  mode  code  shall 
only  be used to communicate  with 
the multiplex bus related hardware, 
and to assist in the management of 
information flow, and not to extract 
data from or feed data to a functional 
subsystem.    Codes  00000  through 
01111 shall only be used for mode 
codes which do not require transfer 
of a data word. For these codes, the 
T/R  bit  shall  be  set  to  1.    Codes 
10000 through 11111 shall only be 
used for mode codes which require 
transfer of a  single data word. For 
these mode codes, the T/R bit shall 
indicate the direction  of data word 
flow as specified in 4.3.3.5.1.3.  No 
multiple data word transfer shall be 
implemented  with  any  mode  code.  
The mode codes are reserved for the 
specific  functions  as  specified  in 
Table 3-I and shall not be used for 
any  other  purpose.  If  the  designer 
chooses to implement  any  of these 
functions,  the  codes,  T/R  bit 
assignments, and use of a data word, 
shall be used as indicated. The use 
of  the  broadcast  command  option 
shall  only  be  applied  to  particular 
mode codes as specified in Table 3-
I.  
When the Subaddress/Mode field is 0 (00000) or 31 (11111) the Word Count/Mode Code field 
identifies the mode code.   
Table 3-I – Assigned Mode Codes 
Specification
Interpretation
T/R Bit
Mode 
Code
Function
Associated 
Data Word
Broadcast 
Command 
Allowed
1
00000
Dynamic Bus 
Control
N
N
1
00001
Synchronize
N
Y
1
00010
Transmit Status 
Word
N
N
1
00011
Initiate Self Test
N
Y
1
00100
Transmitter 
Shutdown
N
Y
1
00101
Override 
Transmitter 
N
Y
1
00110
Inhibit Terminal 
Flag Bit
N
Y
1
00111
Override Inhibit 
Terminal Flag Bit
N
Y
1
01000
Reset RT
N
Y
1
01001
Reserved
N
TBD
1
01111
Reserved
N
TBD
1
10000
Transmit Vector 
Word
Y
N
0
10001
Synchronize
Y
Y
1
10010
Transmit Last 
Command
Y
N
1
10011
Transmit BIT 
Word
Y
N
0
10100
Selected 
Transmitter 
Y
Y
0
10101
Override Selected 
Transmitter 
Y
Y
1 or 0
10110
Reserved
Y
TBD
1 or 0
11111
Reserved
Y
TBD
C# PDF Page Insert Library: insert pages into PDF file in C#.net
Page: Insert PDF Pages. |. Home ›› XDoc.PDF ›› C# PDF: Insert PDF Page. C# PDF - Insert Blank PDF Page in C#.NET. Guide C#
add a jpeg to a pdf; add picture to pdf online
VB.NET PDF Image Extract Library: Select, copy, paste PDF images
Home ›› XDoc.PDF ›› VB.NET PDF: Extract PDF Image. Support PDF Image Extraction from a Page, a Region on a Page, and PDF Document in VB.NET Project.
add photo to pdf form; add a jpg to a pdf
3-12 
GmbH
MIL-STD-1553 Specification Interpretation  
MIL-STD-1553 Tutorial 
4.3.3.5.1.7.1  Dynamic Bus Control 
The controller shall issue a transmit command to an RT capable of performing the bus control 
function.  This RT shall respond with a status word as specified in 4.3.3.5.3.  Control of the 
data bus passes from the offering bus controller to the accepting RT upon completion of the 
transmission of the status word by the RT.  If the RT rejects control of the data bus, the 
offering bus controller retains control of the data bus. 
4.3.3.5.1.7.2  Synchronize (without a data word) 
This command shall cause the RT to synchronize (e.g., to reset the internal timer, to start a 
sequence, etc.).  The RT shall transmit the status word as specified in 4.3.3.5.3. 
4.3.3.5.1.7.3  Transmit Status Word 
This command shall cause the RT to transmit the status word associated with the last valid 
command word preceding this command.  This mode command shall not alter the state of the 
status word. 
4.3.3.5.1.7.4  Initiate Self Test 
This command shall be used to initiate self-test within the RT.  The RT shall transmit the 
status word as specified in 4.3.3.5.3. 
A Dynamic bus control mode command allows the active BC to transfer control of the bus to 
a remote terminal device.  Acceptance/denial of control resides with the RT and if accepted, 
the RT is promoted to the sole BC on the bus. 
Transmit Status Word is utilized by the BC to determine if the RT received the previous 
command properly. 
Initiate Self Test initiates the RT to perform its Built in Test (BIT).  Usually followed with a 
Transmit BIT word mode command to determine the results of the test.  The degree of testing 
available from the RT is a function of its design and capability. 
Specification
Interpretation
C# PDF insert text Library: insert text into PDF content in C#.net
Text: Insert Text to PDF. |. Home ›› XDoc.PDF ›› C# PDF: Insert Text to PDF. C#.NET PDF SDK - Insert Text to PDF Document in C#.NET.
how to add picture to pdf; add multiple jpg to pdf
C# Word - Insert Image to Word Page in C#.NET
Read: PDF Text Extract; C# Read: PDF Image Extract; C# Write: Insert text into PDF; C# Write: Add Image to PDF; C# Protect: Add Password
acrobat insert image in pdf; add image to pdf form
3-13 
GmbH
MIL-STD-1553 Specification Interpretation
MIL-STD-1553 Tutorial 
4.3.3.5.1.7.5  Transmitter Shutdown  
This  command (to only be  used with dual redundant bus systems) shall cause the RT to 
disable the transmitter associated with the redundant bus.  The RT shall not comply with a 
command to shut down a transmitter on the bus from which this command is received.  In all 
cases, the RT shall respond with a status word as specified in 4.3.3.5.3 after this command. 
4.3.3.5.1.7.6  Override Transmitter Shutdown 
This command (to only be used with dual redundant bus system) shall cause the RT to enable 
a transmitter which was previously disabled.  The RT shall not comply with a command to 
enable a transmitter on the bus from which this command is received.  In all cases, the RT 
shall respond with a status word as specified in 4.3.3.5.3 after this command. 
4.3.3.5.1.7.7 Inhibit Terminal Flag (T/F) bit 
This command shall cause the RT to set the T/F bit in the status word specified in 4.3.3.5.3 to 
logic zero until otherwise commanded.  The RT shall transmit the status word as specified in 
4.3.3.5.3. 
4.3.3.5.1.7.8  Override Inhibit T/F bit 
This command shall cause the RT to override the inhibit T/F bit specified in 4.3.3.5.1.7.7.  
The RT shall transmit the status word as specified in 4.3.3.5.3. 
4.3.3.5.1.7.9  Reset Remote Terminal 
This command shall be used to reset the RT to a power up initialized state.  The RT shall first 
transmit its status word, and then reset. 
Transmitter Shutdown and Override Transmitter Shutdown are used only in a dual redundant 
bus system to shut down and restart an RT.  The Override command must be issued on the 
standby or backup bus.
The Inhibit Terminal Flag, when set, indicates a “no fail” condition, regardless of the actual 
state of the terminal flag. The BC can use this command to eliminate ongoing error messages 
from an RT that may be sending extraneous or erroneous messages. 
Override Inhibit Terminal Flag allows the RT to report its actual operating condition. 
Specification
Interpretation
C# Create PDF from images Library to convert Jpeg, png images to
If you want to turn PDF file into image file format in C# application, then RasterEdge XDoc.PDF for .NET can also help with this.
add picture to pdf in preview; add picture to pdf
C# PowerPoint - Insert Image to PowerPoint File Page in C#.NET
Read: PDF Text Extract; C# Read: PDF Image Extract; C# Write: Insert text into PDF; C# Write: Add Image to PDF; C# Protect: Add Password
how to add image to pdf form; add photo to pdf in preview
3-14 
GmbH
MIL-STD-1553 Specification Interpretation  
MIL-STD-1553 Tutorial 
4.3.3.5.1.7.10  Reserved Mode Codes (01001 to 01111) 
These mode codes are reserved for future use and shall not be used. 
4.3.3.5.1.7.11  Transmit Vector Word 
This command shall cause the RT to transmit a status word as specified in 4.3.3.5.3 and a 
data word containing service request information. 
4.3.3.5.1.7.12  Synchronize (with data word) 
The RT shall receive a command word followed by a data word as specified in 4.3.3.5.2.  The 
data  word  shall  contain  synchronization  information  for  the  RT.    After  receiving  the 
command and data word, the RT shall transmit the status word as specified in 4.3.3.5.3. 
4.3.3.5.1.7.13  Transmit Last Command Word 
This  command  shall  cause  the  RT  to  transmit  its  status  word  as  specified  in  4.3.3.5.3 
followed by a single data word which contains bits 4-19 of the last command word, excluding 
a transmit last command word mode code received by the RT.  This mode command shall not 
alter the state of the RT’s status word  
Transmit Vector Word is related to the Service Request bit in the status word and determines 
specific service requested by the RT. 
Synchronization provides the BC a method of establishing a common timing structure with 
RTs. The synchronization can be done with the Command word itself, or with more detail 
through an attached Data word. 
Transmit  Last  Command  Word  is  sent  by  the  BC to  determine the  last  valid  command 
received by the RT, prior to this mode command. This command is used to determine if errors 
exist and assist in data recovery.  This mode code does not change the contents of the last 
command  or  status  word.  An  RT  resends  the  previous  status  word  with  a  data  word 
containing the previous valid command word received. 
Specification
Interpretation
3-15 
GmbH
MIL-STD-1553 Specification Interpretation
MIL-STD-1553 Tutorial 
4.3.3.5.1.7.14  Transmit Built-in-Test (BIT) Word 
This  command  shall  cause  the  RT  to  transmit  its  status  word  as  specified  in  4.3.3.5.3 
followed by a single data word containing the RT BIT data.  This function is intended to 
supplement  the  available  bits  in  the  status  word  when  the  RT  hardware  is  sufficiently 
complex to warrant its use.  The data word, containing the RT BIT data, shall not be altered 
by the reception of a transmit last command or a transmit status word mode code.  This 
function shall not be used to convey BIT data from the associated subsystems(s). 
4.3.3.5.1.7.15  Selected Transmitter Shutdown 
This command  shall  cause  the  RT to disable the  transmitter  associated  with  a specified 
redundant data bus.  The command is designed for use with systems employing more than 
two redundant buses.  The transmitter that is to be disabled shall be identified in the data 
word following the command word in the format as specified in 4.3.3.5.2.  The RT shall not 
comply with a command to shut down a transmitter on the bus from which this command is 
received. In all cases, the RT shall respond with a status word as specified in 4.3.3.5.3. 
4.3.3.5.1.7.16  Override Selected Transmitter Shutdown 
This command shall cause the RT to enable a transmitter which was previously disabled.  The 
command is designed for use with systems employing more than two redundant buses.  The 
transmitter that is to be enabled shall be identified in the data word following the command 
word in the format as specified in 4.3.3.5.2.  The RT shall not comply with a command to 
enable a transmitter on the bus from which this command is received.  In all cases, the RT 
shall respond with a status word as specified in 4.3.3.5.3. 
4.3.3.5.1.7.17  Reserved Mode Codes (10110 to 11111) 
These mode codes are reserved for future use and shall not be used. 
Transmit BIT Word provides the BC with the selected RT's Built in test results. This command 
allows error recovery procedures without changing the error data recorded in the word. 
Specification
Interpretation
3-16 
GmbH
MIL-STD-1553 Specification Interpretation  
MIL-STD-1553 Tutorial 
4.3.3.5.2  Data Word 
A data word shall be comprised of a sync waveform, data bits, and a parity bit (see Figure 3-
3). 
4.3.3.5.2.1  Sync  
The data sync waveform shall be an invalid 
Manchester waveform as shown on Figure 
3-5.  The width shall be three bit times, with 
the waveform  being  negative  for  the first 
one  and  one-half  bit  times,  and  then 
positive for the following one and one-half 
bit times.   Note that if the bits preceding 
and following the sync are logic ones, then 
the apparent  width of the  sync waveform 
will be increased to four bit times. 
4.3.3.5.2.2  Data 
The sixteen bits following the sync shall be 
utilized for data transmission as specified in 
4.3.2. 
4.3.3.5.2.3  Parity 
The last bit shall be utilized for parity as 
specified in 4.3.3.5.1.6. 
Data words contain the actual information and can be transmitted by a BC or an RT 
Data words are transmitted by a BC, or by an RT in response to a BC request.  Data words 
may also be sent between two RTs.  MIL-STD-1553B allows a maximum of 32 data words to 
be sent in a packet with a command word.  Data words contain the most information of the 
three words and are the least structured words in MIL-STD-1553B.  
The Data word sync is unique.  The command and status word sync pattern is the same.
Data          Word Sync 
Data 
Bit   
Bit 
Figure 3-5 – Data Sync
Bit  
Stream
+ VOLTS
- VOLTS 
Specification
Interpretation
3-17 
GmbH
MIL-STD-1553 Specification Interpretation
MIL-STD-1553 Tutorial 
4.3.3.5.3  Status Word 
A  status  word  shall  be  comprised  of  a  sync  waveform,  RT  address,  message  error  bit, 
instrumentation bit, service request bit, three reserved bits, broadcast command received bit, 
busy bit, subsystem flag bit, dynamic bus control acceptance bit, terminal flag bit, and a parity 
bit.  For optional broadcast operation, transmission of the status word shall be suppressed as 
specified in 4.3.3.6.7. 
4.3.3.5.3.1  Sync 
The status sync waveform shall be as specified in 4.3.3.5.1.1. 
4.3.3.5.3.2  RT Address 
The next five bits following the sync shall contain the address of the RT which is transmitting 
the status word as defined in 4.3.3.5.1.2. 
Status words are transmitted by a remote terminal in response to an error free, nonbroadcast 
command.  Status words relay conditional information about the RT, errors detected by the 
RT in the command or data sent from the BC, or an RT request for service.  Status words are 
only transmitted by RTs after receiving a command from a BC.  
The purpose of transmitting the RT address in a status response allows the BC to verify the 
correct RT is responding and prevents any other RT from mistaking the status response as a 
command (the sync pattern for both is the same) due to different addresses. 
Specification
Interpretation
3-18 
GmbH
MIL-STD-1553 Specification Interpretation  
MIL-STD-1553 Tutorial 
4.3.3.5.3.3  Message Error Bit 
The status word bit at bit time nine (see Figure 3-3) shall be utilized to indicate that one or 
more of the data words associated with the preceding received command word from the bus 
controller has failed to pass the RT’s validity test as specified in 4.4.1.1.  This bit shall also be 
set under the conditions specified in 4.4.1.2, 4.4.3.4, and 4.4.3.6.  A logic one shall indicate 
the presence of a message error, and a logic zero shall show its absence.  All RTs shall 
implement the message error bit. 
4.3.3.5.3.4 Instrumentation Bit  
The status word at bit time ten (see Figure 3-3) shall be reserved for the instrumentation bit 
and shall always be a logic zero. This bit is intended to be used in conjunction with a logic 
one in bit time ten of the command word to distinguish between a command word and a 
status word. The use of the instrumentation bit is optional. 
The Message Error Bit is used by the RT to indicate an error in the command or data word 
transmission from the BC.   The Message  Error  bit is set  to a  logic  1 when any of the 
following conditions occur: 
a. 
A data word received from the BC contains an error 
b. 
A gap is detected between data words 
c. 
The RT does not recognize a received command 
d. 
The wrong number of data words is received by the RT. 
If the RT detects an error, the Message Error bit is set, but the status word is not sent. The 
BC  must send  a “Transmit Last  Status” mode  command to  determine the  reason for no 
response. After receiving this mode command, the RT transmits the Status word with the 
Message Error bit set. The Message Error bit remains set to a logic 1 until a new valid 
command, other than “Transmit Last Status”, is received by this RT. 
The Instrumentation bit is used to differentiate between command and status words. 
Specification
n
Interpretation
n
Documents you may be interested
Documents you may be interested