pdf viewer c# open source : How to add jpg to pdf file application software utility azure windows web page visual studio PACSystems_%20RX7i%20&%20RX3i%20CPU%20Reference%20ManualGFK2222W_PACSystems_RX3i_Rx7i_CPU_Ref_Manual1-part2114

Chapter 1. Introduction 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
1.1
Revisions in this Manual 
Note:  A given feature may not be implemented on all PACSystems CPUs. To determine whether a 
feature is available on a given CPU model and firmware version, please refer to the Important 
Product Information (IPI) document provided for the CPU version that you are using. 
Rev 
Date 
Description 
Aug-
2015 
Addition of support for Ethernet Global Data (Class 1) on CPE330 
June-
2015 
Addition of RX3i CPE330 (new product) and related Ethernet considerations. 
Update of Energy Pack Section 4.11.3 to include ACC402 and compatibility matrix. 
Addition of HART® Pass Through feature. 
Addition of CPU Comparison Charts (Section 2.2 and Section 2.3). 
Update of Communications Section (Chapter 5). Added Serial Port Electrical Isolation. 
Removed original Chapters 5-11 (chapters dealing with CPU programming) and Chapter 14 
(Diagnostics). These are now in PACSystems RX7i and RX3i CPU Programmer’s Reference 
Manual, GFK-2950 (Chapters 2-8 and Chapter 9 respectively). 
Nov-
2014 
New Appendix (A-3.6) EGD Sweep Impact for Embedded Ethernet Interface on RX3i CPE305 
and CPE310. 
Oct-
2014 
Support for OPC UA using embedded Ethernet port in CPE305/CPE310 with CPU firmware 
8.20.  
Support for Ethernet Global Data (EGD Class 1) using embedded Ethernet port in 
CPE305/CPE310 with CPU firmware 8.30 Sweep impact of EGD on Embedded Ethernet 
interface. Direct replacement for S90-30 IC693CPU374.  
New communications capabilities provided by: 
o
IC695PNS001 – PROFINET Scanner Module 
o
IC695GCG001 – Genius Communications Gateway via PROFINET 
o
IC695EDS001 – Ethernet based DNP3 Outstation 
July-
2013 
Support for Modbus/TCP Server, SRTP channels and Modbus/TCP client channels on RX3i 
CPE305/CPE310 embedded Ethernet interface – Chapter 2 & Chapter 5 
Support for Access Control List –  Chapter 3 
Modbus TCP/IP mapping for CPE305/CPE310 – Chapter 3 
Enhanced Security Passwords and OEM Protection – Chapter 4 
Serial I/O protocol enhancements (Data Set Ready, Ring Indicator, and Data Carrier Detect) 
– Chapter 6 
Diagnostics for PROFINET alarms and PROFINET network faults, including #PNIO_ALARM, 
SA0030 – refer to PACSystems RX7i and RX3i CPU Programmer’s Reference Manual, 
GFK-2950 Chapter 3 & Chapter 9.  
Instruction executions times measured for  RX3i CPU320/CRU320 – Appendix A 
Sweep impact times for new modules: IC694MDL758, IC694APU300-CA and later, 
IC695PNS001, IC694ALG442, IC694ALG220, IC694MDL645 and IC694MDL740 – Appendix A 
®
HART
®
is a registered trademark of the HART Communication Foundation of Austin, Texas USA. Any use of the term HART 
hereafter in this document, or any document referenced by this document, implies the registered trademark. 
How to add jpg to pdf file - insert images into PDF in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Sample C# code to add image, picture, logo or digital photo into PDF document page using PDF page editor control
add signature image to pdf; how to add a jpeg to a pdf file
How to add jpg to pdf file - VB.NET PDF insert image library: insert images into PDF in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide VB.NET Programmers How to Add Images in PDF Document
add photo pdf; how to add picture to pdf
Chapter 1. Introduction 
GFK-2222W 
August 2015 
Rev 
Date 
Description 
earlier 
Added instructions for replacing the RX3i CPE305/CPE310 real-time clock battery: Chapter 2 
Corrected definitions of reverse acting and direct acting modes for PID functions: refer to 
PACSystems RX7i and RX3i CPU Programmer’s Reference Manual, GFK-2950 Chapter 7. 
Expanded data for Boolean execution measurements – Appendix A 
Re-instated instruction times for RX7i CPE030/CRE030/CPE040 release 6.0 as published in 
version Q of the manual (unintentionally omitted from version R) – Appendix A 
Compatibility information for volatile memory backup batteries has been consolidated in 
the PACSystems Battery and Energy Pack Manual –  throughout 
VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.
Add necessary references page As PDFPage = doc.GetPage(0) ' Convert the first PDF page to page.ConvertToImage(ImageType.JPEG, Program.RootPath + "\\Output.jpg").
how to add photo to pdf in preview; add png to pdf preview
C# PDF Convert to Jpeg SDK: Convert PDF to JPEG images in C#.net
example, this C#.NET PDF to JPEG converter library will name the converted JPEG image file Output.jpg. Convert PDF to JPEG Using C#.NET. Add necessary references
adding an image to a pdf form; add jpg to pdf
Chapter 1. Introduction 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
1.2
PACSystems Control System Overview 
The PACSystems controller environment combines performance, productivity, openness and 
flexibility. The PACSystems control system integrates advanced technology with existing systems. The 
result is seamless migration that protects your investment in I/O and application development. 
1.2.1
Programming and Configuration 
Proficy* Machine Edition programming software provides a universal engineering development 
environment for all programming, configuration and diagnostics of PACSystems. A PACSystems CPU 
is programmed and configured using the programming software to perform process and discrete 
automation for various applications. The CPU communicates with I/O and smart option modules 
through a rack-mounted backplane. It communicates with the programmer and/or HMI devices via 
the Ethernet ports or via the serial ports COM1 and COM2 using Serial I/O, or Modbus RTU slave 
protocols. 
1.2.2
Process Systems 
PACSystems CPUs with firmware version 5.0 and later support Proficy Process Systems (PPS). PPS is a 
complete, tightly integrated, seamless process control system using PACSystems, Proficy HMI/SCADA, 
and Proficy Production Management Software to provide control, optimization, and performance 
management to manage and monitor batch or continuous manufacturing. It delivers the tools 
required to design, implement, document, and maintain an automated process. For information 
about purchasing PPS software, refer to the Support website. 
C# Image Convert: How to Convert Adobe PDF to Jpeg, Png, Bmp, &
C# DLLs for PDF Conversion to Images. Add necessary references to your C# project: This demo code convert PDF file all pages to jpg images.
add jpg signature to pdf; add an image to a pdf
C# Image Convert: How to Convert Dicom Image File to Raster Images
Add necessary references to your C# project RasterEdge.XDoc.PDF.dll. inputFilePath = @"C:\input.dcm"; String outputFilePath = @"C:\output.jpg"; // Convert dicom
add jpg to pdf document; add photo to pdf reader
Chapter 1. Introduction 
GFK-2222W 
August 2015 
1.2.3
PACSystems CPU Model 
Family 
Catalog Number 
Description 
RX3i CPUs 
IC695CPU310 
300MHz Celeron CPU, 10 MB user memory 
IC695CPU315 
1 GHz Celeron-M CPU, 20 MB user memory 
IC695CPU320 
1 GHz Celeron-M CPU, 64 MB user memory 
IC695NIU001+ 
versions –AAAA & later 
1.1 GHz Atom 510 NIU. For information, refer to the 
PACSystems RX3i Ethernet Network Interface Unit 
User’s Manual, GFK-2439 
IC695NIU001 
300MHz Celeron NIU. For information, refer to the 
PACSystems RX3i Ethernet Network Interface Unit 
User’s Manual, GFK-2439 
RX3i CPUs with 
embedded Ethernet 
Interface
1
IC695CPE305 
1.1GHz Atom CPU, 5 MB user memory 
IC695CPE310 
1.1GHz Atom CPU, 10 MB user memory 
IC695CPE330 
1 GHz AMD G-Series Dual Core, 64 MB user memory 
RX3i Redundancy 
CPU 
IC695CRU320 
1 GHz Celeron-M CPU, 64 MB user memory 
RX7i CPUs with 
embedded Ethernet 
Interface 
IC698CPE010 
300MHz, Celeron CPU, 10MB user memory 
IC698CPE020 
700MHz, Pentium CPU, 10 MB user memory 
IC698CPE030 
600MHz, Pentium-M CPU, 64MB user memory 
IC698CPE040 
1800MHz, Pentium-M CPU, 64MB user memory 
RX7i Redundancy 
CPUs with 
embedded 
Ethernet Interface 
IC698CRE020 
700MHz, Pentium CPU, 10 MB user memory 
IC698CRE030 
600MHz, Pentium-M CPU, 64MB user memory 
IC698CRE040 
1800MHz, Pentium-M CPU, 64MB user memory 
1
The RX3i CPE305/CPE310 embedded Ethernet interface provides a maximum of two programmer connections. It does not 
support the full set of Ethernet interface features described in this manual. For a summary of RX3i embedded Ethernet 
interface features, refer to PACSystems RX7i & RX3i TCP/IP Ethernet Communications User Manual, GFK-2224K or later. 
C# Create PDF from images Library to convert Jpeg, png images to
images.Add(new Bitmap(Program.RootPath + "\\" 1.jpg")); images.Add(new Bitmap(Program.RootPath + "\\" 1.png")); / Build a PDF document with
adding images to pdf; how to add an image to a pdf in preview
C# WPF PDF Viewer SDK to convert and export PDF document to other
Highlight Text. Add Text. Add Text Box. Drawing Markups. Add Stamp Annotation. image file formats with high quality, support converting PDF to PNG, JPG, BMP and
how to add a jpg to a pdf; how to add an image to a pdf file in acrobat
Chapter 1. Introduction 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
1.3
RX3i Overview 
The RX3i control system hardware consists of an RX3i universal backplane and up to seven 
Series 90-30 expansion or remote racks. The CPU can be in any slot in the universal backplane 
except the last slot, which is reserved for the serial bus transmitter, IC695LRE001. 
The RX3i supports user defined Function Blocks (LD logic only) and Structured Text programming. 
The RX3i universal backplane uses a dual bus that provides both: 
High-speed PCI for fast throughput of new advanced I/O. 
Serial backplane for easy migration of existing Series 90-30 I/O 
The RX3i universal backplane and Series 90-30 expansion/remote racks support the Series 90-30 
Genius Bus Controller and Motion Control modules, and most Series 90-30/RX3i discrete and analog 
I/O with catalog prefixes IC693 and IC694. RX3i modules with catalog prefixes IC695, including the 
Ethernet and other communications modules can only be installed in the universal backplane. See 
the PACSystems RX3i System Manual, GFK-2314 for a list of supported modules. 
RX3i supports hot standby (HSB) CPU redundancy, which allows a critical application or process to 
continue operating if a failure occurs in any single component. A CPU redundancy system consists of 
an active unit that actively controls the process and a backup unit that is synchronized with the 
active unit and can take over the process if it becomes necessary. Each unit must have a redundancy 
CPU, (IC695CRU320). The redundancy communication path is provided by IC695RMX128 Redundancy 
Memory Xchange (RMX) modules set up as redundancy links. For details on the operation of 
PACSystems redundancy systems, refer to the PACSystems Hot Standby CPU Redundancy User 
Manual, GFK-2308. 
RX3i communications features include: 
Open communications support includes Ethernet, PROFIBUS, PROFINET, Modbus TCP, Ethernet 
Global Data (EGD), DNP3 and serial protocols.  
The CPE305, CPE310 and CPE330 CPUs provide an embedded Ethernet interface which is used to 
connect to the programmer (Proficy Machine Edition).  
Effective with RX3i CPE310/CPE305 Firmware Release 7.30, or CPE330 Firmware Release 8.50, the 
embedded Ethernet port on the CPU provided support for Service Request Transfer Protocol 
(SRTP) channels and for Modbus TCP.  
Effective with CPE310/CPE305 Firmware Release 8.20, or CPE330 Firmware Release 8.45, the CPE 
embedded Ethernet port supports OPC UA Server. Refer to PACSystems RX7i & RX3i TCP/IP 
Ethernet Communications User Manual, GFK-2224 version M or higher (Chapter 10). 
Effective with RX3i Firmware Release 8.30
2
, the CPE310/CPE305 CPUs alsosupport Ethernet 
Global Data (EGD). Prior to that firmware release, EGD was only available in the RX3i via the RX3i 
Ethernet Interface Module (IC695ETM001). With this upgrade, these CPUs are positioned as a 
direct replacement for S90-30 IC693CPU374. 
Effective with RX3i Firmware Release 8.60
3
, the CPE330 supports Ethernet Global Data (EGD) 
Class 1. 
The rack-based IC695ETM001 Ethernet Interface has dual RJ-45 ports connected through an 
auto-sensing switch. This eliminates the need for rack-to-rack switches or hubs. The ETM001 
supports upload, download and online monitoring, and provides 32 SRTP channels with a 
maximum of 48 simultaneous SRTP server connections. It also supports Modbus TCP. For details 
on Ethernet Interface capabilities, refer to PACSystems RX7i & RX3i TCP/IP Ethernet 
Communications User Manual, GFK-2224.  
C# PDF File Merge Library: Merge, append PDF files in C#.net, ASP.
Combine scanned images to PDF, such as tiff, jpg, png, gif, bmp, etc. Add necessary references: In addition, C# users can append a PDF file to the end of a
add a picture to a pdf; adding a jpeg to a pdf
VB.NET PDF File Merge Library: Merge, append PDF files in vb.net
to combine various scanned images to PDF, such as tiff, jpg, png, gif Add necessary references: In addition, VB.NET users can append a PDF file to the end of a
adding images to pdf files; add signature image to pdf acrobat
Chapter 1. Introduction 
GFK-2222W 
August 2015 
PROFIBUS communications via the PROFIBUS Master module, IC695PBM300. For details, refer to 
the PACSystems RX3i PROFIBUS Modules User’s Manual, GFK-2301.  
PROFINET communications via the PROFINET Controller module IC695PNC001 and PROFINET 
Scanner module IC695PNS001. For details, refer to the PACSystems RX3i PROFINET I/O Controller 
Manual, GFK-2571 and PACSystems RX3i PROFINET Scanner Manual, GFK-2737. 
Effective with the release of IC695CEP001 and IC694CEE001, the RX3i may be configured to 
control a remote drop consisting of one or two I/O modules. The RX3i interface to the remote 
drop is managed by the PROFINET Controller, IC695PNC001. Refer to PACSystems RX3i CEP 
PROFINET Scanner User Manual, GFK-2883. 
HART Pass Through entails usage of PC-based applications, RX3i Analog modules with HART 
functionality and (optionally) supporting PROFINET products. HART Pass Through operation is 
described in the PACSystems HART Pass Through User Manual, GFK-2929. 
The following RX3i CPUs support HART Pass Through: IC695CPE305, IC695CPE310, IC695CPU315, 
IC695CPU320, IC695CRU320, IC695CPE330 (Firmware Release 8.50 or later). 
The following RX3i analog modules support HART: 
IC695ALG626 
IC695ALG628 
IC695ALG728 
If used for HART Pass Through, the supporting RX3i PROFINET Controller (PNC001) and PROFINET 
Scanner (PNS001 or CEP001) must also contain HART-compatible firmware:
IC695PNC001-AK Firmware Release 2.20 
IC695PNS001-ABAH Firmware Release 2.30 
IC695CEP001-AAAD Firmware Release 2.30. 
Effective with the release of IC695GCG001, the RX3i may be equipped to control a Genius Bus. 
The RX3i interface to the Genius Gateway is managed by the PROFINET Controller, IC695PNC001. 
Refer to PACSystems RX3i Genius Communications Gateway User Manual, GFK-2892. 
Effective with the release of IC695EDS001, the RX3i may be configured as a DNP3 Outstation. 
Refer to PACSystems RX3i DNP3 Outstation Module IC695EDS001User’s Manual, GFK-2911. 
Effective with the release of IC695EIS001, the RX3i may be configured to act as an
IEC 104 Server. 
Refer to PACSystems RX3i IEC 104 Server Module IC695EIS001 User’s Manual, GFK-2949. 
IC695CMM002 and IC695CMM004 expand the serial communications capability of the RX3i 
system. Refer to PACSystems RX3i Serial Communications Modules User’s Manual, GFK-2460. 
CPE310, CPU310, CPU315, CPU/CRU320 and NIU001 provide two serial ports, one RS-232 and 
one RS-485. 
CPE305 provides one RS-232 serial port. 
Chapter 1. Introduction 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
1.4
RX7i Overview 
The RX7i control system hardware consists of an RX7i rack and up to seven Series 90-70 expansion 
racks. The CPU resides in slot 1 of the main rack. RX7i racks use a VME64 backplane that provides up 
to four times the bandwidth of existing VME based systems, including the current Series 90-70 
systems for faster I/O throughput. The VME64 base supports all standard VME modules including 
Series 90-70 I/O and VMIC modules. 
Expansion racks support Series 90-70 discrete and analog I/O, the Genius Bus Controller, and the 
High Speed Counter. The CPU provides an embedded auto-sensing 10/100 Mbps half/full duplex 
Ethernet interface. 
RX7i supports hot standby (HSB) CPU redundancy, which allows a critical application or process to 
continue operating if a failure occurs in any single component. A CPU redundancy system consists of 
an active unit that actively controls the process and a backup unit that is synchronized with the 
active unit and can take over the process if it becomes necessary. Each unit must have a redundancy 
CPU, (IC698CRE020, CRE030 or CRE040). The redundancy communication path is provided by 
IC698RMX016 Redundancy Memory Xchange (RMX) modules set up as redundancy links. For details 
on the operation of PACSystems redundancy systems, refer to the PACSystems Hot Standby CPU 
Redundancy User Manual, GFK-2308. 
Note:   Extended operation with dissimilar CPU types is not allowed. During normal operation, the 
primary and secondary units in an HSB redundancy system must have the same CPU model 
type.  
The primary and secondary units of an HSB redundancy system can have dissimilar model 
types for a limited time, for the purpose of system upgrade only. Fail wait times for the higher 
performance CPU in a dissimilar redundant pair may need to be increased to allow 
synchronization. 
RX7i communications features include: 
Open communications support includes Ethernet, Genius, and serial protocols. 
A built-in 10/100mb Ethernet interface that has dual RJ-45 ports connected through an auto-
sensing switch for upload, download and online monitoring. This eliminates the need for rack-to-
rack switches or hubs. The CPU Ethernet Interface provides basic remote control system 
monitoring from a web browser and allows a combined total of up to 16 web server and FTP 
connections. For details on Ethernet Interface capabilities, refer to PACSystems RX7i & RX3i 
TCP/IP Ethernet Communications User Manual, GFK-2224. 
Two serial ports, one RS-232 and one RS-485. 
An RS-232 isolated Ethernet Station Manager serial port. 
Chapter 1. Introduction 
GFK-2222W 
August 2015 
1.5
Migrating Series 90 Applications to PACSystems 
The PACSystems control system provides cost-effective expansion of existing systems. Support for 
existing Series 90 modules, expansion racks and remote racks protects your hardware investment. 
You can upgrade on your timetable without disturbing panel wiring. 
The RX3i supports most Series 90-30 modules, expansion racks, and remote racks. For a list of 
supported I/O, Communications, Motion, and Intelligent modules, see the PACSystems RX3i 
System Manual, GFK-2314. 
The RX7i supports most existing Series 90-70 modules, expansion racks and Genius networks. For 
a list of supported I/O, Communications, and Intelligent modules, see the PACSystems RX7i 
Installation Manual, GFK-2223. 
Conversion of Series 90-70 and Series 90-30 programs preserves existing development effort. 
Conversion of VersaPro and Logicmaster applications to Machine Edition allows smooth 
transition to PACSystems. 
Chapter 1. Introduction 
10 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
1.6
PACSystems Documentation 
PACSystems Manuals 
PACSystems RX7i and RX3i CPU Reference Manual 
GFK-2222 
PACSystems RX7i and RX3i CPU Programmer’s Reference Manual 
GFK-2950 
PACSystems RX7i & RX3i TCP/IP Ethernet Communications User Manual 
GFK-2224 
PACSystems TCP/IP Ethernet Communications Station Manager User Manual 
GFK-2225 
C Programmer’s Toolkit for PACSystems 
GFK-2259 
PACSystems Memory Xchange Modules User’s Manual 
GFK-2300 
PACSystems Hot Standby CPU Redundancy User Manual 
GFK-2308 
PACSystems Battery and Energy Pack Manual 
GFK-2741 
Proficy Machine Edition Logic Developer Getting Started 
GFK-1918 
Proficy Process Systems Getting Started Guide 
GFK-2487 
PACSystems RXi, RX3i, and RX7i Controller Secure Deployment Guide 
GFK-2830 
RX3i Manuals 
PACSystems RX3i System Manual 
GFK-2314 
PACSystems RX3i IC695ACC400 Energy Pack Data Sheet 
GFK-2724 
PACSystems RX3i IC695ACC402 Energy Pack Quick Start Guide 
GFK-2939 
DSM324i Motion Controller for PACSystems RX3i and Series 90-30 User’s Manual  GFK-2347 
PACSystems RX3i PROFIBUS Modules User’s Manual 
GFK-2301 
PACSystems RX3i Max-On Hot Standby Redundancy User’s Manual 
GFK-2409 
PACSystems RX3i Ethernet Network Interface Unit User’s Manual 
GFK-2439 
PACMotion Multi-Axis Motion Controller User’s Manual 
GFK-2448 
PACSystems RX3i PROFINET I/O Controller Manual 
GFK-2571 
PACSystems RX3i PROFINET Scanner Manual 
GFK-2737 
PACSystems RX3i CEP PROFINET Scanner User Manual 
GFK-2883 
PACSystems RX3i Serial Communications Modules User’s Manual 
GFK-2460 
PACSystems RX3i Genius Communications Gateway User Manual 
GFK-2892 
PACSystems RX3i DNP3 Outstation Module IC695EDS001User’s Manual 
GFK-2911 
PACSystems RX3i IEC 104 Server Module IC695EIS001User’s Manual 
GFK-2949 
PACSystems HART Pass Through User Manual 
GFK-2929 
RX7i Manuals 
PACSystems RX7i Installation Manual 
GFK-2223 
PACSystems RX7i User's Guide to Integration of VME Modules 
GFK-2235 
Series 90-70 Genius Bus Controller User’s Manual 
GFK-2017 
Series 90 Manuals 
Series 90 Programmable Coprocessor Module and Support Software 
GFK-0255 
Series 90 PLC Serial Communications User’s Manual  
GFK-0582 
Series 90-70 DLAN/DLAN+ Interface Module User’s Manual 
GFK-0729 
Series 90-30 Genius Bus Controller User’s Manual 
GFK-1034 
Distributed I/O Systems Manuals 
Genius I/O System User’s Manual 
GEK-90486-1 
Genius I/O Analog and Discrete Blocks User’s Manual 
GEK-90486-2 
In addition to these manuals, datasheets and product update documents describe individual 
modules and product revisions. The most recent PACSystems documentation is available on the 
GE Intelligent Platforms support website http://support.ge-ip.com .
GFK-2222W 
August 2015 
11 
Chapter 2
CPU Features & Specifications 
This chapter provides details on the hardware features of the PACSystems CPUs and their 
specifications. 
 Common CPU Features
 RX3i CPU Features and Specifications
 RX7i CPU Features and Specifications
Documents you may be interested