5.1.1.3
10Base-T/100Base-Tx Port Pin Assignments 
Pin assignments are the same for the RX3i and RX7i embedded Ethernet ports.  
Pin Number  Signal  Description 
TD+  Transmit Data + 
TD-  Transmit Data - 
RD+  Receive Data + 
NC  No connection 
NC  No connection 
RD-  Receive Data - 
NC  No connection 
NC  No connection 
5.1.1.4
Recovering a Lost IP Address  
See Establishing Initial Ethernet Communications, Section 3.4.1. 
5.1.2
Ethernet Interface Modules 
In addition to Ethernet interfaces embedded in certain CPUs (see RX3i CPU Features and 
Specifications and RX7i CPU Features and Specifications), the RX7i and RX3i systems support rack-
based Ethernet Interface modules. These modules are not interchangeable.  
For details about the capabilities, installation, and operation of these modules, refer to PACSystems 
RX7i & RX3i TCP/IP Ethernet Communications User Manual GFK-2224 and PACSystems TCP/IP Ethernet 
Communications Station Manager User Manual, GFK-2225. 
Type  Catalog Number  Description 
RX7i  IC698ETM001 
Ethernet peripheral VME module 
RX3i  IC695ETM001 
Ethernet peripheral PCI module 
How to add an image to a pdf file - insert images into PDF in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Sample C# code to add image, picture, logo or digital photo into PDF document page using PDF page editor control
adding an image to a pdf in acrobat; how to add picture to pdf
How to add an image to a pdf file - VB.NET PDF insert image library: insert images into PDF in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide VB.NET Programmers How to Add Images in PDF Document
add a picture to a pdf document; how to add photo to pdf in preview
Chapter 5. Communications 
GFK-2222W 
August 2015 
123 
5.2
Serial Communications 
RX3i CPUs, except CPE330, support one or more serial ports (see Section 2.2). RX7i CPUs support three 
serial ports (see Section 2.3). The independent on-board serial ports of the CPU are accessed via 
connectors on the front of the module. COM1 and COM2 provide serial interfaces to external devices. 
COM1 is also used for firmware upgrades. The third serial port (COM3) on RX7i CPUs is used as the 
Ethernet Station Manager port.  
5.2.1
Serial Port Communications Capabilities 
COM1 and COM2 can each be configured for one of the following modes. For details on CPU 
configuration, refer to Chapter 3. 
RTU Slave – The port can be used for the Modbus RTU slave protocol. This mode also permits 
connection to the port by an SNP master, such as the WinLoader utility or the programming 
software. For details, refer to Chapter 6, Serial I/O, SNP & RTU Protocols. 
Message Mode – The port is available for access by user logic. This enables C language blocks to 
perform serial port I/O operations via C Runtime Library functions.  
Available – The port is not to be used by the CPU firmware. 
SNP Slave – The port can only be used for the SNP slave protocol. For details, refer to Chapter 6, 
Serial I/O, SNP & RTU Protocols. 
Serial I/O – The port can be used for general-purpose serial communication through use of 
COMMREQ functions. For details, refer to Chapter 6, Serial I/O, SNP & RTU Protocols. 
5.2.1.1
Features Supported 
Feature 
Serial Port 1 
(COM1) 
Serial Port 2 
(COM2) 
Serial Port 3 
(Station Mgr) 
RX7i only 
RTU Slave protocol 
Yes 
Yes 
No 
SNP Slave 
Yes 
Yes 
No 
Serial I/O – used with COMMREQs 
Yes 
Yes 
No 
Firmware Upgrade 
(WinLoader utility) 
CPU in 
STOP/No IO mode 
No 
No 
Message Mode –used only with C blocks 
(C Runtime Library Functions: 
serial read, serial write, sscanf, sprintf) 
Yes 
Yes 
No 
Station Manager (RX7i only) 
No
33
No
33
Yes 
RS-232 
Yes 
No 
Yes 
RS-485 
No 
Yes 
No 
33
RX3i CPE305, CPE310, CPE330, ETM001 & EDS001 support Station Manager using UDP over Ethernet, but not via serial 
communications.  
VB.NET PDF Password Library: add, remove, edit PDF file password
This VB.NET example shows how to add PDF file password with access permission setting. passwordSetting.IsAssemble = True ' Add password to PDF file.
add photo to pdf in preview; add photo pdf
C# PDF Password Library: add, remove, edit PDF file password in C#
This example shows how to add PDF file password with access permission setting. passwordSetting.IsAssemble = true; // Add password to PDF file.
add a picture to a pdf; add picture pdf
Chapter 5. Communications 
124 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
5.2.2
Configurable STOP Mode Protocols 
You can configure the protocol to be used in STOP Mode, based upon the configured serial port (RUN 
Mode) protocol. The Run/Stop protocol switching is independently configured for each serial port. 
The RUN Mode protocol setting determines which choices are available for STOP Mode. If a STOP 
Mode protocol is not selected, the default STOP Mode protocol is used. For details, refer to COM1 and 
COM2 Parameters in Chapter 3. 
5.2.3
Serial Port Pin Assignments 
5.2.3.1
COM1 (RS-232, 9-pin Subminiature D Connector) 
This port has a 9-pin, female, D-sub connector with a standard pin out. This is a DCE (data 
communications equipment) port that allows a simple straight-through cable to connect with a 
standard AT-style RS-232 port. 
The CPE310 provides the DCD and RI signals to support point-to-point protocol (PPP). 
COM1 RS-232 Signals 
RX3i CPU, RX3i CRU, 
and RX7i CPE Models 
RX3i CPE310 Model 
Pin No.
34
Signal Name  Description 
Pin No.
34
Signal Name  Description 
NC 
No Connection 
DCD 
Data Carrier Detect 
TXD 
Transmit Data 
TXD 
Transmit Data 
RXD 
Receive Data 
RXD 
Receive Data 
DSR 
Data Set Ready 
DSR 
Data Set Ready 
0V 
Signal Ground 
COM 
Signal Ground 
DTR 
Data Terminal Ready    6 
DTR 
Data Terminal Ready 
CTS 
Clear to Send 
CTS 
Clear to Send 
RTS 
Request to Send 
RTS 
Request to Send 
NC 
No Connection 
RI 
Ring Indicator 
5.2.3.2
COM1 (RS-232, RJ-25 Connector) 
The CPE305 provides RS-232 communications via an RJ-25 connector and requires shielded cable 
IC693CBL316.  
CPE305 COM1 RS-232 Signals 
Pin No.  Signal Name  Description 
CTS 
Clear to Send 
TXD 
Transmit Data 
0V 
Signal Ground 
0V 
Signal Ground 
RXD 
Received Data 
RTS 
Request to Send 
34
Pin 1 is at the bottom right of the connector as viewed from the front of the module. 
C# PDF File & Page Process Library SDK for C#.net, ASP.NET, MVC
C# File: Split PDF; C# Page: Insert PDF pages; C# Page: Delete PDF pages; C# Read: PDF Image Extract; C# Write: Insert text into PDF; C# Write: Add Image to PDF;
how to add image to pdf; add photo to pdf online
C# PDF Image Extract Library: Select, copy, paste PDF images in C#
Scan image to PDF, tiff and various image formats. Get image information, such as its location, zonal information Able to edit, add, delete, move, and output PDF
add jpg to pdf form; add image to pdf java
Chapter 5. Communications 
GFK-2222W 
August 2015 
125 
5.2.3.3
COM2 (RS-485, 15-pin Female D-sub Connector) –RX7i CPU/CRU Models 
This port does not supply +5Vdc volts, therefore RS-485 to RS-232 conversion requires a converter 
that is self-powered. It does not support the RS-485 to RS-232 adapter IC690ACC901. 
This is a DCE port that allows a simple straight-through cable to connect with a standard AT-style 
RS-232 port. 
COM2 RS-485 Signals 
Pin No.  Signal Name  Description 
Shield 
Cable Shield  
Located at the bottom right of the connector  
as viewed from the front of the module. 
2  
NC 
No Connection 
3  
NC 
No Connection 
4  
NC 
No Connection 
5  
NC 
No Connection 
6  
RTS(A) 
Differential Request to Send A 
7  
0V 
Signal Ground 
8  
CTS(B‘) 
Differential Clear To Send 
RT
35
Resistor Termination 
10  
RD(A‘)
35,36
Differential Receive Data A 
11  
RD(B‘)
36
Differential Receive Data B 
12  
SD(A) 
Differential Send Data A 
13  
SD(B) 
Differential Send Data B 
14  
RTS(B’) 
Differential Request To Send B 
15  
CTS(A’) 
Differential Clear To Send A 
35
To provide termination using the built-in 120Ω resistor, install a jumper between pins 9 and 10. 
36
To provide termination using an external resistor, connect a user-supplied resistor across pins 10 and 11. 
C# PDF File Compress Library: Compress reduce PDF size in C#.net
Convert smooth lines to curves. Detect and merge image fragments. Flatten visible layers. C#.NET DLLs: Compress PDF Document. Add necessary references:
add png to pdf acrobat; adding image to pdf
VB.NET PDF File Compress Library: Compress reduce PDF size in vb.
Reduce image resources: Since images are usually or large size, images size reducing can help to reduce PDF file size effectively.
adding an image to a pdf in preview; add picture to pdf in preview
Chapter 5. Communications 
126 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
5.2.3.4
COM2 (RS-485, 15-pin Female D-sub Connector) – All RX3i CPU/CRU Models & RX3i 
CPE310 
This is a DCE port that allows a simple straight-through cable to connect with a standard AT-style 
RS-232 port. 
COM2 RS-485 Signals 
Pin No.  Signal Name  Description 
Shield 
Cable Shield 
Located at the bottom right of the connector as viewed from the front of the 
module. 
2  
NC 
No Connection 
3  
NC 
No Connection 
4  
NC 
No Connection 
5  
+5Vdc 
Logic Power: Provides isolated +5Vdc power (300mA maximum) for 
powering external options. 
6  
RTS(A) 
Differential Request to Send A 
7  
0V 
Signal Ground 
8  
CTS(B‘) 
Differential Clear To Send B 
9  
RT
35
Resistor Termination 
10  
RD(A‘)
35, 36
Differential Receive Data A 
11  
RD(B‘)
36
Differential Receive Data B 
12  
SD(A) 
Differential Send Data A 
13  
SD(B) 
Differential Send Data B 
14  
RTS(B’) 
Differential Request To Send B 
15  
CTS(A’) 
Differential Clear To Send A 
VB.NET PDF Image Extract Library: Select, copy, paste PDF images
PDF SDK for .NET, VB.NET users are able to extract image from PDF page or file and specified DLLs for PDF Image Extraction in VB.NET. Add necessary references:
acrobat insert image in pdf; how to add jpg to pdf file
C# PDF File Merge Library: Merge, append PDF files in C#.net, ASP.
PDF document splitting, PDF page reordering and PDF page image and text Add necessary references: In addition, C# users can append a PDF file to the end of a
add jpg to pdf document; how to add an image to a pdf file in acrobat
Chapter 5. Communications 
GFK-2222W 
August 2015 
127 
5.2.3.5
COM3 (RX7i only) 
COM3, the Station Manager serial port used to support the embedded Ethernet Interface, is RS-232 
compatible. COM3 has a 9-pin, female, D-connector. This is a DCE port that allows a simple straight-
through cable to connect with a standard AT-style RS-232 port. This port contains full use of the 
standard RS-232 signals for future use with point-to-point protocol (PPP).  
Station Manager RS-232 Signals 
Pin No.
34
Signal Name  Description 
DCD 
Data Carrier Detect 
TXD 
Transmit Data 
RXD 
Receive Data 
DSR 
Data Set Ready 
0V 
Signal Ground 
DTR 
Data Terminal Ready 
CTS 
Clear To Send 
RTS 
Request To Send 
RI 
Ring Indicator 
Chapter 5. Communications 
128 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
5.2.4
Serial Port Electrical Isolation  
Some serial communication ports are isolated, while others are not, as indicated in the following 
table:  
Family  Model 
COM1 
COM2 
COM3 
RX3i 
CPU310 
Non-Isolated 
Non-Isolated 
N/A 
CPU315 
Non-Isolated 
Non-Isolated 
N/A 
CPU320/CRU320  Non-Isolated 
Non-Isolated 
N/A 
CPE305 
Non-Isolated 
N/A 
N/A 
CPE310 
Non-Isolated 
Non-Isolated 
N/A 
CPE330 
N/A 
N/A 
N/A 
RX7i 
CPE010 
Optocoupler Isolated  Optocoupler Isolated  Optocoupler Isolated 
CPE020/CRE020  Optocoupler Isolated  Optocoupler Isolated  Optocoupler Isolated 
CPE030/CRE030  Optocoupler Isolated  Optocoupler Isolated  Optocoupler Isolated 
CPE040/CRE040  Optocoupler Isolated  Optocoupler Isolated  Optocoupler Isolated 
Chapter 5. Communications 
GFK-2222W 
August 2015 
129 
5.2.5
Serial Cable Lengths and Shielding 
The connection from a CPU serial port to the serial port on a computer or other serial device requires 
a serial cable. Maximum cable lengths (the total distance from the CPU to the last device attached to 
the serial cable) are: 
Port 
Maximum Cable 
Length 
Cable Type 
COM1 (RS-232) 
15 m (50 ft.) 
Shielded cable required for 
RX3i; 
Shielded cable optional for RX7i 
COM2 (RS-485) 
1200 m (4000 ft.) 
Shielded cable required for all 
models that support this port 
STA MGR/COM3 (RS-232)  15 m (50 ft.) 
Shielded cable optional (RX7i 
only) 
Note:  For details on conformance to radiated emissions standards, refer to Appendix A in the 
following manuals: 
PACSystems RX7i Installation Manual, GFK-2223 
PACSystems RX3i System Manual, GFK-2314 
Chapter 5. Communications 
130 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
5.2.6
Serial Port Baud Rates 
Protocol 
COM1 
(RS-232) 
COM2 
(RS-485) 
Station Mgr (COM3) 
(RS-232) 
RTU Slave 
1200, 2400, 4800, 
9600, 19.2K, 38.4K, 
57.6K, 115.2K 
1200, 2400, 
4800, 9600, 
19.2K, 38.4K, 
57.6K, 115.2K 
not supported 
Firmware 
Upgrade via 
WinLoader 
1200, 2400, 4800, 
9600, 19.2K, 38.4K, 
57.6K, 115.2K 
Not supported 
not supported 
Message Mode  1200, 2400, 4800, 
9600, 19.2K, 38.4K, 
57.6K, 115.2K 
1200, 2400, 
4800, 9600, 
19.2K, 38.4K, 
57.6K, 115.2K 
not supported  
SNP Slave 
1200, 2400, 4800, 
9600, 19.2K, 38.4K, 
57.6K, 115.2K 
1200, 2400, 
4800, 9600, 
19.2K, 38.4K, 
57.6K, 115.2K 
not supported 
Serial I/O 
1200, 2400, 4800, 
9600, 19.2K, 38.4K, 
57.6K, 115.2K 
1200, 2400, 
4800, 9600, 
19.2K, 38.4K, 
57.6K, 115.2K 
not supported 
Chapter 5. Communications 
GFK-2222W 
August 2015 
131 
5.3
Series 90-70 Communications and Intelligent Option Modules 
PACSystems RX7i supports the following Series 90-70 communications and intelligent option 
modules: 
Communications Coprocessor Module (CMM), IC697CMM711 
Programmable Coprocessor Module (PCM), IC697PCM711 
DLAN Interface Module, IC697BEM763 
5.3.1
Communications Coprocessor Module (CMM)
PACSystems RX7i CPUs with versions 1.50 and higher support IC697CMM711 modules with firmware 
versions 4.20 and higher. You must ensure that you are using a valid version of the CMM firmware 
because the CPU cannot check the CMM’s firmware version. (The module’s firmware version can be 
found on a label attached to the EEPROM.) 
PACSystems does not support the following with an IC697CMM711: 
Access to Symbolic variables  
WAIT mode COMMREQs. 
Connecting the programming software to the CPU through the CMM’s serial ports. 
Permanent datagrams. 
The following restrictions apply when using the IC697CMM711 with PACSystems: 
Access to %W references is partially supported. Only offsets 0—65535 of %W can be accessed 
via the CMM. 
The Program Name is currently always LDPROG1 for PACSystems. 
Reads and writes beyond currently configured reference table limits will report a minor code 
error of 90 (REF_OUT_OF_RANGE) instead of F4 (INVALID_PARAMETER) as reported on the Series 
90-70. 
In case of ERROR NACK, the Control Program number, privilege level and other piggyback status 
data will be set to 0. 
PACSystems CPUs return the major/minor type of the 90-70 CPX935 (major type 12, minor type 
35) to the CMM scratch pad memory when communicating with a CMM.  
Control Program Number will be returned as 01 in PACSystems instead of FF as reported on the 
Series 90-70. 
If your RX7i application program needs to access the dual port memory of a CMM, use the BUS 
READ and WRITE functions. When accessing the CMM, set the Region parameter on the function 
block to 1. (For the CMM, region 1 is predefined to be the module's entire dual port memory.) 
Note:  For details on operation of the IC697CMM711, refer to the Series 90 PLC Serial 
Communications User’s Manual, GFK-0582.  
Documents you may be interested
Documents you may be interested