Chapter 2. CPU Features & Specifications 
52 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
Ethernet LED Operation 
LED State 
On
Blinking
Off
Ethernet Operating State 
EOK   
Blink error code 
LAN   
Off 
STAT   
Off 
Hardware Failure 
EOK   
Fast Blink 
LAN   
Off 
STAT   
Off 
Performing Diagnostics 
EOK   
Slow Blink 
LAN   
Off 
STAT   
Off 
Waiting for Ethernet configuration from CPU 
EOK   
Slow Blink
LAN   
On/Traffic/Off 
STAT   
Slow Blink
(† EOK and STAT blink in unison) 
Waiting for IP Address 
EOK   
On 
LAN   
On/Traffic/Off 
STAT   
On/Off 
Operational 
EOK   
Slow Blink
LAN   
Slow Blink
STAT   
Slow Blink
(‡ All LEDs blink in unison) 
Software Load 
Adding images to pdf forms - insert images into PDF in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Sample C# code to add image, picture, logo or digital photo into PDF document page using PDF page editor control
add jpg to pdf file; add picture to pdf form
Adding images to pdf forms - VB.NET PDF insert image library: insert images into PDF in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide VB.NET Programmers How to Add Images in PDF Document
add a picture to a pdf file; add image pdf
Chapter 2. CPU Features & Specifications 
GFK-2222W 
August 2015 
53 
EOK LED Operation 
The EOK LED indicates whether the Ethernet interface is able to perform normal operation. This LED is 
on for normal operation and blinks for all other operations. When a hardware or unrecoverable 
runtime failure occurs, the EOK LED blinks a two-digit error code identifying the failure. The LED first 
blinks to indicate the most significant error digit, then after a brief pause blinks again to indicate the 
least significant error digit. After a long pause the error code display repeats.  
EOK LED Blink Codes for Ethernet Hardware Failures 
Blink Code  Description 
0x12 
Undefined or Unexpected Interrupt. 
0x13 
Timer failure during power up diagnostics. 
0x14 
DMA failure during power up diagnostics. 
0x21 
RAM failure during power up diagnostics. 
0x22 
Stack error during power up diagnostics. 
0x23 
Shared Memory Interface error during power up diagnostics. 
0x24 
Firmware CRC (cyclic redundancy check) error during power up or Factory Test.
29
0x25 
Run time exception 
0x31 
Undefined instruction or divide by zero 
0x32 
Software interrupt 
0x33 
Instruction pre-fetch abort 
0x34 
Data abort 
0x35 
Unexpected Runtime IRQ 
0x36 
Unexpected Runtime FIQ (fast interrupt request) 
0x37 
Reserved Exception or branch through zero 
29
CRC error or software error during normal operation causes Ethernet restart. 
C# PDF Page Insert Library: insert pages into PDF file in C#.net
NET PDF document page inserting & adding component from PDF page(s) to current target PDF document in server-side application and Windows Forms project using a
adding an image to a pdf file; add picture to pdf online
VB.NET PDF Library SDK to view, edit, convert, process PDF file
Feel free to define text or images on PDF document and extract accordingly. Capable of adding PDF file navigation features to your VB.NET program.
add jpg to pdf form; add image to pdf acrobat reader
Chapter 2. CPU Features & Specifications 
54 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
LAN LED Operation 
The LAN LED indicates access to the Ethernet network. During normal operation, and while waiting 
for an IP address, the LAN LED blinks to indicate network activity. This LED remains on when the 
Ethernet interface is not actively accessing the network but the network is available, and it is off if 
network access is not available. The definition of the network being available as indicated by this LED 
is that the Ethernet physical interface is available and one or both of the Ethernet ports is connected 
to an active network.  
STAT LED Operation 
The STAT LED indicates the condition of the Ethernet interface in normal operational mode. If the 
STAT LED is off, an event has been entered into the exception log and is available for viewing via the 
Station Manager interface. The STAT LED is on during normal operation when no events are logged. 
In the other states, the STAT LED is either off or blinking and helps define the operational state of the 
module. 
Ethernet Port LEDs (100 Mb/Speed and LINK/Activity) Operation 
Each of the two Ethernet ports has two green LED indicators, 100 and LINK.  
The 100 LED indicates the network data speed (10 Mbps or 100 Mbps. This LED is illuminated if the 
network connection is 100 Mbps. 
The LINK LED indicates the network link status and activity. This LED is illuminated when the link is 
physically connected and blinks when traffic is detected at the port. Note that traffic at the port does 
not necessarily mean that traffic is present at the Ethernet interface, since the traffic may be going 
between ports of the switch.  
VB.NET Image: Adding Line Annotation to Images with VB.NET Doc
full sample codes for printing line annotation on images. Basic .NET sample codes for adding a line System.Text Imports System.Windows.Forms Imports RasterEdge
how to add an image to a pdf in reader; how to add image to pdf in acrobat
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
Create new page to PDF document in both ASP.NET web server-side application and .NET Windows Forms. Support adding PDF page number.
add a picture to a pdf; how to add an image to a pdf in acrobat
Chapter 2. CPU Features & Specifications 
GFK-2222W 
August 2015 
55 
2.3.3.3
Ethernet Restart Pushbutton 
The Ethernet Restart pushbutton is used to manually restart the Ethernet firmware without power 
cycling the entire control system. It is recessed to prevent accidental operation. The restart does not 
occur until the pushbutton is released.  
The type of restart behavior is selected by the length of time that the pushbutton is depressed. The 
pushbutton-controlled restart operations are listed in the following table, along with the LED 
indications for each. In all cases, the EOK, LAN and STAT LEDs briefly turn on in unison as an LED test. 
The Ethernet port LEDs are not affected by a manual restart of the Ethernet firmware. 
Restart Operation 
Depress Ethernet Restart 
pushbutton for  
Ethernet LEDs 
Illuminated 
Normal restart 
Less than 5 seconds 
EOK, LAN, STAT 
Restart without Ethernet plug-in 
applications 
5 to 10 seconds 
LAN, STAT 
Restart into Firmware Update operation  More than 10 seconds 
STAT 
Normal Restart 
When the Ethernet Restart pushbutton is pressed for less than 5 seconds, the Ethernet interface will 
restart into normal operation.  
Restart without Ethernet Plug-in Applications 
When the Restart pushbutton is pressed and held for 5 to 10 seconds, the Ethernet interface will 
restart into normal operation but does not start any optional Ethernet plug-in applications. This is 
typically done during troubleshooting. 
Restart into Firmware Update Operation 
When the Ethernet Restart pushbutton is pressed and held for more than 10 seconds, the Ethernet 
interface will restart into firmware update operation. This is typically done during troubleshooting to 
bypass possibly invalid firmware and allow valid firmware to be loaded using WinLoader.  
Until the firmware update actually begins, you can manually exit the firmware update and restart 
with the existing firmware by pressing the Ethernet Restart pushbutton again.  
C# Create PDF Library SDK to convert PDF from other file formats
What's more, you can also protect created PDF file by adding digital signature (watermark) on PDF using C# code. Create PDF from Jpeg, png, images.
how to add a picture to a pdf document; add image to pdf online
VB.NET PDF: VB Code to Create PDF Windows Viewer Using DocImage
PDF page in many ways, like adding rectangle, line view, annotate, process, save and scan images (supporting JPEG and BMP) and document files (TIFF, PDF and Word
add png to pdf acrobat; add image to pdf in preview
Chapter 2. CPU Features & Specifications 
56 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
C# Image: Document Image Ellipse Annotation Creating and Adding
on color, bitional and black & white images; annotation shape to image - support adding rubber stamp powerful & profession imaging controls, PDF document, tiff
adding image to pdf; add an image to a pdf in preview
C# PDF: PDF Document Viewer & Reader SDK for Windows Forms
After adding WinViewer DLL into Visual Studio Toolbox, you link to see more C# PDF imaging project converting, compressing and stroing images, documents and
add picture to pdf; add an image to a pdf with acrobat
GFK-2222W 
August 2015 
57 
Chapter 3
CPU Configuration 
The PACSystems CPU and I/O system is configured using Proficy Machine Edition (PME) Logic 
Developer-PLC programming software. 
The CPU verifies the physical module and rack configuration at power-up and periodically during 
operation. The physical configuration must be the same as the programmed configuration. 
Differences are reported to the CPU alarm processor for configured fault response. Refer to the 
Machine Edition Logic Developer-PLC Getting Started Manual, GFK-1918 and the online help for a 
description of configuration functions.  
Note:  A CPE020, CPE030 or CPE040 can be converted to the corresponding redundancy CPU 
(CRE020, CRE030 or CRE040) by installing different firmware and moving a jumper. Detailed 
instructions are included in the firmware upgrade kit for the redundancy CPU.  
This chapter covers: 
Configuring the CPU
Configuration Parameters
Storing (Downloading) Hardware Configuration
Configuring the Embedded Ethernet Interface
VB.NET Image: How to Draw Annotation on Doc Images with Image SDK
other image annotating tutorials besides adding annotation using PDF document, image to pdf files and converting, compressing and stroing images, documents and
add photo to pdf file; adding an image to a pdf
VB.NET TIFF: Read, Edit & Process TIFF with VB.NET Image Document
at the page level, like TIFF page adding & deleting controls, PDF document, image to pdf files and converting, compressing and stroing images, documents and more
add jpg to pdf online; add photo to pdf preview
Chapter 3. CPU Configuration 
58 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
3.1
Configuring the CPU 
To configure the CPU using the Logic Developer-PLC programming software, do the following: 
1.
In the Project tab of the Navigator, expand your 
PACSystems Target, the hardware configuration, 
and the main rack (Rack 0). 
2.
Right click the CPU slot and choose Configure. The 
Parameter Editor window displays the CPU 
parameters. 
Note:  An RX7i CPU must be installed in Rack 0, Slot 1. 
A double-wide RX3i CPU occupies two slots and 
can be installed in any pair of slots in Rack 0 
except the two highest numbered lots in the 
rack. The single-wide CPE305 RX3i CPU requires 
one slot and can be installed in any slot in RX3i 
Rack 0, except the highest numbered slot or 
slot 0. 
3.
To edit a parameter value, click the desired tab, 
then click in the appropriate Values field. For 
information on these fields, refer to Configuration 
Parameters. 
4.
Store the configuration to the Controller so these 
settings can take effect. For details, see Storing 
(Downloading) Hardware Configuration. 
Note:  If available, the embedded Ethernet Interface is displayed in a sub-slot of the CPU. For 
configuration details, refer to Configuring the Embedded Ethernet Interface. 
Figure 14: PME Expansion of PACSystems 
Target 
Chapter 3. CPU Configuration 
GFK-2222W 
August 2015 
59 
3.2
Configuration Parameters 
3.2.1
Settings Parameters 
These parameters specify basic operating characteristics of the CPU. For details on how these 
parameters affect CPU operation, refer to PACSystems RX7i and RX3i CPU Programmer’s Reference 
Manual, GFK-2950 Chapter 2. 
Settings Parameters 
Passwords 
Specifies whether passwords are Enabled or Disabled. Default: Enabled. 
Note:  If Enhanced Security
30
is enabled in the target properties, the Passwords 
setting will be Enabled and read-only, and the Access Control tab appears. 
When passwords are disabled, they cannot be re-enabled without clearing PLC 
memory.  
Stop-Mode I/O 
Scanning  
Specifies whether the I/O is scanned while the PLC is in STOP Mode. Default: Disabled. 
(Always Disabled for Redundancy CPU.) 
Note:  This parameter corresponds to the I/O ScanStop parameter on a Series 90-70 
PLC.  
Watchdog Timer 
(ms)  
(Denominated in ms, set in 10ms increments.) Requires a value that is greater than the 
program sweep time. 
The software watchdog timer is designed to detect failure to complete sweep 
conditions. The CPU restarts the watchdog timer at the beginning of each sweep. The 
watchdog timer accumulates time during the sweep. The software watchdog timer is 
useful in detecting abnormal operation of the application program, which could 
prevent the PLC sweep from completing within the watchdog time period.  
Valid range: 10 ms through 2550 ms, in increments of 10 ms. 
Default: 200. 
For details on setting the watchdog timer in a CPU redundancy system, refer to the 
PACSystems Hot Standby CPU Redundancy User Manual, GFK-2308. 
Logic/Configuration 
Power-up Source 
Specifies the location/source of the logic and configuration data that is to be used (or 
loaded/copied into RAM) after each power up. 
Choices: Always RAM, Always Flash, Conditional Flash. 
Default: Always RAM. 
Data Power-up 
Source  
Specifies the location/source of the reference data that is to be used (or loaded/copied 
into RAM) after each power up. 
Choices: Always RAM, Always Flash, Conditional Flash. 
Default: Always RAM. 
30
For availability, refer to the Important Product Information document for the CPU firmware version that you are using. 
Chapter 3. CPU Configuration 
60 
PACSystems* RX7i & RX3i CPU Reference Manual 
GFK-2222W 
Settings Parameters 
RUN/STOP Switch 
Enables or disables the physical operation of the RUN/STOP Switch.  
Choices: 
Enabled: Enables you to use the physical switch on the PLC to switch the PLC into STOP 
Mode or from STOP Mode into RUN Mode and clear non-fatal faults.  
Disabled: Disables the physical RUN/STOP Switch on the PLC.  
Default: Enabled. 
Note:  If COM1 and COM2 are configured for any protocol other than RTU Slave or 
SNP Slave, the RUN/STOP Switch should not be disabled without first must 
making sure that there is a way to stop the CPU, or take control of the CPU 
through another device such as an Ethernet interface. If the CPU can be set to 
STOP Mode, it will switch the protocol from Serial I/O to the STOP Mode 
protocol (default is RTU Slave). For details on STOP Mode settings, refer to 
COM1 and COM2 Parameters. 
This applies to COM1 on the CPE305, which has only one serial port. 
This note does not apply to CPUs which have no serial ports. 
Memory Protection 
Switch 
Enables or disables the Memory Protect feature associated with the RUN/STOP Switch.  
Choices: 
Enabled: Memory Protect is enabled, which prevents writing to program memory and 
configuration and forcing or overriding discrete data.  
Disabled: Memory Protect is disabled.  
Default: Disabled. 
Power-up Mode 
Selects the CPU mode to be in effect immediately after power-up.  
Choices: Last, Stop, Run. 
Default: Last (the mode it was in when it last powered down). 
Note:  If the battery or Energy Pack is missing or has failed and if Logic/Configuration 
Power-up Source is set to Always RAM, the CPU powers up in STOP Mode 
regardless of the setting of the Power-up Mode parameter. 
Modbus Address 
Space Mapping 
Type 
Specifies the type of memory mapping to be used for data transfer between Modbus 
TCP/IP clients and the PACSystems controller. 
Choices: 
Disabled: The Disabled setting is intended for use in systems containing Ethernet 
firmware that does not support Modbus TCP.  
Standard Modbus Addressing: Causes the Ethernet firmware to use the standard map, 
which is displayed on the Modbus TCP Address Map tab. 
Default: Disabled 
For details on the PACSystems implementation of Modbus/TCP server, refer to 
PACSystems RX7i & RX3i TCP/IP Ethernet Communications User Manual, GFK-2224. 
Universal Serial Bus  RX3i CPE305/CPE310/CPE330 CPUs only. Enables or disables the USB port for use with 
RDSD (Removable Data Storage Devices). The USB port is enabled by default in the 
CPE305/CPE310/CPE330 and in the hardware configuration. 
If a CPU310 configuration is stored to a CPE310, the USB port will be enabled. 
Chapter 3. CPU Configuration 
GFK-2222W 
August 2015 
61 
3.2.2
Modbus TCP Address Map 
This read-only tab displays the standard mapping assignments between Modbus address space and 
the CPU address space. Ethernet modules and daughterboards in the PACSystems controller use 
Modbus-to-PLC address mapping based on this map. 
Modbus 
Register 
The Modbus protocol uses five reference table designations:  
0xxxx Coil Table. Mapped to the %Q table in the CPU. 
1xxxx Input Discrete Table. Mapped to the %I table in the CPU. 
3xxxx Input Register Table. Mapped to the %AI register table in the CPU. 
4xxxx Holding Register Table. Mapped to the %R table in the CPU. 
6xxxx File Access Table. Mapped to the %W table in the CPU. 
Start Address 
Lists the beginning address of the mapped region. 
End Address 
Lists the ending address of the mapped region. For word memory types (%AI, %R and %W) 
the highest address available is configured on the Memory tab. 
PLC Memory  
Lists the memory type of the mapped region. 
Length 
Displays the length of the mapped region. 
Documents you may be interested
Documents you may be interested