pdf viewer c# winform : Adding image to pdf control application platform web page azure wpf web browser pct_11747581-part2287

9000XDrive User Manual   
11 
10. Datalogger buffers 
The latest trigged datalogger data is always in RAM memory ('Current' checkbox) of the 
frequency converter. The data is then copied into FLASH memory ('History') so that the data is 
not lost if frequency converter is switched off. Every time the datalogger triggers, the latest data is 
put into slot 1 and the rest are moved up. Slot 1 goes to slot 2, slot 2 goes to slot 3, slot 3 goes to 
slot 4, and slot 4 is lost.  
Note that these option buttons are visible only if the system software in drive is new enough (later 
than April 2005), and if "Advanced Datalogger" checkbox has been checked in 
Options|Datalogger.  
11. Load from Target.  
When the datalogger has trigged you will see text ‘Trigged’  in the 9000XDrive’s status row.  You 
can then upload that data to your PC. Pressing this button will first open a dialog where you must 
give a file name where the data will be saved. After the data has been read to a file, it is opened 
into the Datalogger window.  
12. Set New.  
After you have set the signals and the trigger, you can press the ‘Set New’  button to write the 
settings to the frequency converter. The text in the status row will change to ‘Waiting Trigger… … ’.  
Setting a datalogger  
After you have set the signals and the trigger, you can press the Set button to write the settings to 
the frequency converter. The text in the status row will change to Waiting Trigger… … 
If you wish, you can now close the Datalogger window, because the data logging and trigging 
happens in the frequency converter. The status (Idle, Waiting Trigger…, Post Trigging…, Trigged  
is updated on the status bar of the 9000XDrive tool.  
Reading the datalogger data from the frequency converter.  
When the datalogger has trigged you will see text Trigged in the 9000XDrive’s status row. You 
can then upload that data to your PC.  
Press the Load From Target button. Pressing this button will first open a dialog where you must 
give a file name where the data will be saved. After the data has been read to a file, it is opened 
into the 9000XDrive program.  
Reading the datalogger data from a file  
Every time you load the datalogger data from the frequency converter, the data is first saved to a 
file. You can later open these files by using the File|Open menu.  
Adding image to pdf - insert images into PDF in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Sample C# code to add image, picture, logo or digital photo into PDF document page using PDF page editor control
adding an image to a pdf form; add photo to pdf in preview
Adding image to pdf - VB.NET PDF insert image library: insert images into PDF in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide VB.NET Programmers How to Add Images in PDF Document
add photo to pdf preview; add image to pdf in preview
9000XDrive User Manual   
12 
Datalogger graphical window  
1. You can hide or show individual signals from the graphical view by clicking these buttons. 
2. You can move in the x-axis and the y-axis with the mouse by first pressing either of the buttons 
and then dragging the scale with a mouse. You can also zoom into the graphic by first pressing 
the left mouse button in the start corner and then moving the mouse pointer to the end corner of 
the area that you want to zoom and then releasing the mouse button. You can zoom back by 
clicking the right mouse button somewhere on the graphics. 
3. The trigger point is always shown with a red vertical line. 
4. This data table shows the signal names, data types of the signals and the minimum and 
maximum scales of the signals. When you open a datalogger log file, the scales are automatically 
set to show the whole signal variation in the y scale. You can also change the Scale Min and 
Scale Max columns yourself. By clicking the buttons in ‘Auto’ column, you can auto-scale the 
signals again. 
5. You can auto-scale each of the signals by clicking these buttons. 
6. This frame shows the trigger information. 
If you zoom into graphics or otherwise change the Y-scales in the graphical window, you can set 
the scales back to the limits you have set by clicking the Reset Scales button. 
You can also show or hide the Y scales by clicking the Show Y Scales checkbox.  
Printing Datalogger graphics 
You can print the graphics by selecting Print from the File menu. You can also print the graphics 
to a file by selecting Print to File from the File menu.   
C# Word - Insert Image to Word Page in C#.NET
VB.NET How-to, VB.NET PDF, VB.NET Word, VB.NET Excel, VB.NET PowerPoint, VB.NET Tiff, VB.NET Imaging, VB It's a demo code for adding image to word page using C#.
how to add a jpg to a pdf; add signature image to pdf
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
Support adding PDF page number. Offer PDF page break inserting function. DLLs for Adding Page into PDF Document in VB.NET Class. Add necessary references:
add image pdf acrobat; add an image to a pdf
9000XDrive User Manual   
13 
Menus  
File Menu 
New 
Opens an application in offline mode. 
Open… 
Opens previously saved parameter files. 
Save 
Saves parameters to a file. 
Save As… 
Asks a file name and saves parameters to a file. 
Print Preview 
Shows a print preview window. 
Print… 
Prints parameters or trends depending of the active window. 
Print To File… 
Prints parameters or trend to a file. 
Service Info... 
Reads parameters, drive info, active faults and fault history and shows them in a window. You 
can 
print the contents of this window or save it to a file. 
Exit 
Exits the program.  
Edit Menu 
Undo 
Undo the last parameter change (F12).  
View Menu 
Parameters 
Shows the parameter window. 
Operating 
Shows the Operating window. 
Monitoring 
Shows the Monitoring window. 
Diagnostic 
Shows the Diagnostic window. 
Toolbar 
Toggles the Toolbar on and off. 
Statusbar 
Toggles the Statusbar on and off.  
VB.NET PDF Library SDK to view, edit, convert, process PDF file
PDF document to/from supported document and image forms. to define text or images on PDF document and Capable of adding PDF file navigation features to your VB
adding image to pdf form; adding an image to a pdf
C# PowerPoint - Insert Image to PowerPoint File Page in C#.NET
C#.NET PDF Reading, C#.NET Annotate PDF in WPF, C#.NET PDF Create, C#.NET PDF Document Viewer, C#.NET PDF Windows Viewer, C#.NET convert image to PDF, C#.NET
how to add picture to pdf; add picture to pdf in preview
9000XDrive User Manual   
14 
Drive Menu 
Application 
Shows the available applications in frequency converter and let’s you change the active 
application 
in frequency converter. 
Language 
Shows the languages that the frequency converter software supports and let’s you change the 
active language in frequency converter. 
Upload 
Uploads the parameters from frequency converter to PC. 
Download 
Downloads the parameters from PC to frequency converter. 
Parameter Sets 
Allows you to save and load parameter set 1 and 2 in frequency converter. 
Info 
Shows information of the frequency converter.  
Window Menu 
Cascade 
Rearranges the windows so they overlap in a cascade.  
Help Menu 
Contents 
Shows this help file. 
About 
Shows information of this program.   
C# PDF Page Insert Library: insert pages into PDF file in C#.net
By using reliable APIs, C# programmers are capable of adding and inserting (empty) PDF page or pages from various file formats, such as PDF, Tiff, Word, Excel
how to add image to pdf acrobat; how to add an image to a pdf file
C# PDF insert text Library: insert text into PDF content in C#.net
Supports adding text to PDF in preview without adobe reader installed in ASP.NET. Powerful .NET PDF edit control allows modify existing scanned PDF text.
add photo to pdf for; how to add image to pdf in preview
9000XDrive User Manual   
15 
Toolbar  
1. New 
Open 
Save 
Print  
2. These option buttons show the current program state. Online mode means that every 
parameter change that you make in parameter window will immediately be written to a converter 
and it also indicates that you are communicating with a converter. You can’t go to online mode if 
you don’t have a converter connected to your PC.  Offline mode means that the parameter 
changes you make are written only to program’s internal memory. You can save these parameter 
values to a parameter file and later download them to a converter.  
Selecting the Online option button will cause the parameters to be uploaded and a parameter 
window to be showed. You can also press the Upload button directly, it will do the same thing as 
selecting the Online option button and the mode changes automatically to online mode. You can 
even press the Parameter Window button and it will do the same thing.  
3. This icon indicates the current program state graphically. There will be a converter connected 
to PC in online mode and a file symbol in offline mode.  
4. Upload 
Download 
Parameter Window 
Operating Window 
Monitoring Window 
Diagnostic Window 
Drive Select Window   
VB.NET Image: How to Draw Annotation on Doc Images with Image SDK
multi-page TIFF, Microsoft Office Word and PDF file programmer, you might need some other image annotating tutorials besides adding annotation using VB
attach image to pdf form; add a jpg to a pdf
VB.NET TIFF: Add New Image to TIFF File in Visual Basic .NET
NET TIFF image processing SDK and its TIFF image adding function at this section, the following parts will describe the sample method for adding image to TIFF
adding a jpeg to a pdf; how to add a photo to a pdf document
9000XDrive User Manual   
16 
Parameter Window  
1. This tree view shows the menu structure of the application. The parameter view on the right will 
change according to parameter group selection.  
2. This table shows the parameters of the selected group or groups. You can change the 
parameter’s value simply by clicking the right row and entering a new value to the value column. 
You can always undo the last change by pressing F12. 
3. The source where the parameters are loaded from is shown here. If you open an  application in 
offline mode using File|New command, you will open that application with default values and a 
word ‘DEFAULTS’  is shown. If you open a previously saved parameter file using File|Open 
command, you will get that application with parameter values you have saved and a path and 
filename of the parameter file is shown here. If you upload the parameter values from a frequency 
converter, a word ‘LOADED’  is shown.  
4. If you want to compare the parameter values with default values or with parameter values 
saved to a file, press Compare…  and select either File or Defaults.  
VB.NET TIFF: Read, Edit & Process TIFF with VB.NET Image Document
TIFF document at the page level, like TIFF page adding & deleting to provide powerful & profession imaging controls, PDF document, image to pdf files and
add image in pdf using java; add photo to pdf in preview
9000XDrive User Manual   
17 
Compare Parameters  
You can compare the parameters you have in your computer against a previously saved 
parameter file.  
Press the Compare… button in the top of the Parameter window. A dialog will open to select a 
parameter file to compare against. After selecting the parameter file a compare window will open:  
1. The number of found differences is shown in title bar.  
2. Here you can see the source of the values that you are comparing with current parameter 
values. The ‘Compared Value’  field shows the value from source file.  
3. This column shows the values from the current application. You can also change the 
parameter’s value directly in this column. 
Example: If you want to compare the values in frequency converter with a parameter file that you 
have earlier saved, do the following: Upload the parameters from frequency converter, click 
Compare… button and select the parameter file. Cl ick OK and the Parameter Comparison  
window will open. 
You can print this window by pressing the Print… button.  
9000XDrive User Manual   
18 
Monitoring Window  
1.  Trend signal table 
This table shows the signals you want to monitor in graphical format. Select first the Type of the 
signal (Value is default) you want to monitor and then select the signal from Signal name column.  
The Actual column shows the signal’s current value. If you want, you can change the signal’s 
minimum and maximum scales by changing the Scale min and Scale max columns. The 
Autoscaling checkbox will automatically scale the signal to the minimum and maximum values in 
the signal buffer.  You can change the signal to some other signal simply by selecting a new 
signal from the Signal name column.  
If you want to delete a signal from the trend signal table, click on that row and press the delete 
button.  
2. Trend signal view 
Maximum of 8 signals can be monitored in the Monitoring page and all the signals are shown in 
the same view. You can zoom anywhere in the signal view by dragging a range with a mouse. 
You can zoom back to full view by pressing the Reset Scales button, or you can zoom back little 
by little by clicking the right mouse button. You can get a vertical ruler to the trend view by clicking 
near the left or right edge of the trend view, or a horizontal ruler by clicking near the bottom or top 
of the trend view.  
3. Y-scale (Signal value scale) 
Each signal has its own y-scale. The scale shows the name of the signal and the unit of the 
signal.  
Minimum and maximum range is by default the signal’s Scale min and Scale max values. You 
can change the range by entering new value to Scale min and Scale max columns or by dragging 
the Y-scale with mouse. You can use right or left mouse buttons or both.  
9000XDrive User Manual   
19 
4. X-scale (Time scale) 
When the signal is selected, the time scale shows by default the whole time range that results 
from the Sampling Rate. The signal buffer is 1000 values per signal. If the Sampling Interval is for 
example 100 ms, the buffer will cover the time period of 100ms * 1000 samples = 100000ms = 
100 s. You can change the visible time scale by dragging the X-scale with mouse.  
5. Curve visibility buttons 
You can show/hide any signal with these buttons. If you have many signals in measurement, the 
monitor view can sometimes be hard to follow. Hide the signals that are not important in that 
moment. The monitoring will still continue in the background and when you show the signals 
again, they will show the correct values.  
6. Curve color 
Each signal has a different color. You can quickly see which curve corresponds to which signal by 
checking the color.  
7. Autoscaling 
The Autoscaling checkbox will automatically scale the signal to the minimum and maximum 
values in the signal buffer.  
8. Control panel 
You can start, pause and stop the signal measurement by clicking the corresponding buttons in 
the Control panel. These buttons will start, pause and stop ALL the signals at a time. 
If you press the Pause button the measurement will still continue in the background and when 
you press Run, the curve will show the values measured in the background and continue 
normally. 
If you press the Stop button the measurement will stop and when you press the Run button again, 
the measurement will continue from that point and whatever the signal was in between will not 
show in the screen. 
The Settings button shows the Monitor Settings window. In Monitor Settings window you can set 
the sampling interval of the signals and set triggers. 
The Clear button clears all the signal buffers. 
The Hide Table button hides the trend signal table and you can see the trends a bit larger. The 
Show button will appear after you have selected Hide. 
The Reset Scales button resets all the scales to their default values. If you have zoomed to some 
signal you can press this button to get back to full view.  
The Snapshot button saves either a bmp picture or trn file of the current monitor graphics to a 
snapshot directory. You can select which snapshot file is used and what is the snapshot directory 
in Options dialog. 
9. Trigger Signal 
If you have defined a trigger in Monitor Settings window, you can see which signal has the trigger 
of the color of the signal name. Red indicates the trigger signal. 
10. Point of trigger 
When the trigger has fired, the trends will stop and a red marker will appear to the point where the 
trigger fired. The place where the marker appears depends on the Post Sampling setting in the 
Monitor Settings window.  
9000XDrive User Manual   
20 
Monitor Settings  
In the Monitor Settings window you can set the sampling interval of the signals you have selected 
in the Monitoring page and set triggers to one of the signals. 
1. Sampling Interval setting is used with all the signals. You can’t set different sampling intervals 
to different signals. 
2. Continuous/Trigger setting defines if you want to set a trigger to some signal or if you just want 
to see signals run continuously without triggers. You have to select the Trigger option before you 
can set the trigger. 
3. Trigger signal table. Select the signal that you want to set the trigger on, and set the trigger 
level.  Selects also if the trigger will fire on the rising or on thefalling edge. Note that you can only 
set the trigger to one of the signals you have selected in Monitoring window. 
4. Post-Sampling defines how many samples are still sampled after the trigger has fired. 
5. You can temporarily set the trigger of by un-checking this checkbox. When you want to set the 
trigger back on, just check this checkbox again. 
6. You can set the ‘amount’ how quickly the signal must change before a Derivate trigger fires. 
With Derivate ON checkbox you can temporarily set the Derivate trigger off.   