upload pdf file in asp.net c# : Copy and paste image from pdf to pdf Library application class asp.net html .net ajax SDEF0-part966

Primavera
®
P6
SDEF Conversion
Copy and paste image from pdf to pdf - copy, paste, cut PDF images in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Detailed tutorial for copying, pasting, and cutting image in PDF page using C# class code
copy and paste image from pdf to pdf; how to copy an image from a pdf in preview
Copy and paste image from pdf to pdf - VB.NET PDF copy, paste image library: copy, paste, cut PDF images in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET Tutorial for How to Cut or Copy an Image from One Page and Paste to Another
copy picture from pdf reader; how to copy images from pdf
Copyright © 1999, 2009, Oracle and/or its affiliates. All rights reserved.
The Programs (which include both the software and documentation) contain proprietary information; they are 
provided under a license agreement containing restrictions on use and disclosure and are also protected by 
copyright, patent, and other intellectual and industrial property laws. Reverse engineering, disassembly, or 
decompilation of the Programs, except to the extent required to obtain interoperability with other independently 
created software or as specified by law, is prohibited.
The information contained in this document is subject to change without notice. If you find any problems in the 
documentation, please report them to us in writing. This document is not warranted to be error-free. Except as 
may be expressly permitted in your license agreement for these Programs, no part of these Programs may be 
reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose.
If the Programs are delivered to the United States Government or anyone licensing or using the Programs on 
behalf of the United States Government, the following notice is applicable:
U.S. GOVERNMENT RIGHTS Programs, software, databases, and related documentation and technical data 
delivered to U.S. Government customers are "commercial computer software" or "commercial technical data" 
pursuant to the applicable Federal Acquisition Regulation and agency-specific supplemental regulations. As 
such, use, duplication, disclosure, modification, and adaptation of the Programs, including documentation and 
technical data, shall be subject to the licensing restrictions set forth in the applicable Oracle license agreement, 
and, to the extent applicable, the additional rights set forth in FAR 52.227-19, Commercial Computer Software--
Restricted Rights (June 1987). Oracle USA, Inc., 500 Oracle Parkway, Redwood City, CA 94065.
The Programs are not intended for use in any nuclear, aviation, mass transit, medical, or other inherently 
dangerous applications. It shall be the licensee's responsibility to take all appropriate fail-safe, backup, redun-
dancy and other measures to ensure the safe use of such applications if the Programs are used for such purposes, 
and we disclaim liability for any damages caused by such use of the Programs.
Oracle, JD Edwards, PeopleSoft, and Siebel are registered trademarks of Oracle Corporation and/or its affiliates. 
Other names may be trademarks of their respective owners.
The Programs may provide links to Web sites and access to content, products, and services from third parties. 
Oracle is not responsible for the availability of, or any content provided on, third-party Web sites. You bear all 
risks associated with the use of such content. If you choose to purchase any products or services from a third 
party, the relationship is directly between you and the third party. Oracle is not responsible for: (a) the quality of 
third-party products or services; or (b) fulfilling any of the terms of the agreement with the third party, including 
delivery of products or services and warranty obligations related to purchased products or services. Oracle is not 
responsible for any loss or damage of any sort that you may incur from dealing with any third party.
To view the P6 Commercial Notices and Disclosures for Documentation, go to the \Documen-
tation\<language>\Notices and Disclosures folder of the P6 physical media or download.
C# PDF Image Extract Library: Select, copy, paste PDF images in C#
How to C#: Extract Image from PDF Document. List<PDFImage> allImages = PDFImageHandler. ExtractImages(page); C#: Select An Image from PDF Page by Position.
copy and paste image into pdf; paste image in pdf file
C# PDF Page Extract Library: copy, paste, cut PDF pages in C#.net
C#.NET PDF Library - Copy and Paste PDF Pages in C#.NET. Easy to C#.NET Sample Code: Copy and Paste PDF Pages Using C#.NET. C# programming
copying image from pdf to word; copy pdf picture to powerpoint
Table of Contents
Primavera
3
SDEF Overview.......................................................................................5
Obtaining SDEF specifications.....................................................................5
Primavera’s SDEF Conversion Utilities.......................................................6
Conversion Considerations...................................................................7
Activity Code Structure Requirements.......................................................10
Using Primavera’s SDEF Conversion Update....................................11
Convert a Project Management Module Project to SDEF..........................11
Convert an SDEF File to a Project Management Module Project..............12
VB.NET PDF Image Extract Library: Select, copy, paste PDF images
VB.NET PDF - Extract Image from PDF Document in VB.NET. Support PDF VB.NET : Select An Image from PDF Page by Position. Sample for
how to copy pdf image into word; how to copy text from pdf image
VB.NET PDF Page Extract Library: copy, paste, cut PDF pages in vb.
VB.NET DLLs: Extract, Copy and Paste PDF Page. Dim page As PDFPage = doc.GetPage(3) ' Select image by the point (50F, 100F).
copy paste picture pdf; how to copy pdf image to jpg
VB.NET PDF insert image library: insert images into PDF in vb.net
VB.NET PDF - Add Image to PDF Page in VB.NET. Insert Image to PDF Page Using VB. Add necessary references: RasterEdge.Imaging.Basic.dll.
how to cut image from pdf; copy and paste image from pdf to word
C# Create PDF from images Library to convert Jpeg, png images to
Best and professional C# image to PDF converter SDK for Visual Studio .NET. C#.NET Example: Convert One Image to PDF in Visual C# .NET Class.
copy image from pdf; how to copy images from pdf file
5
SDEF Overview
In 1986, the US Army Corps of Engineers recognized the need for a Standard 
Data Exchange Format (SDEF) to facilitate the exchange of data among 
contractors using various project management tools. The format chosen was a 
132-character per line, fixed-length ASCII file, with data items, field positions, 
and field lengths explicitly defined by the SDEF specification.
Obtaining SDEF specifications
The complete SDEF specification document is available online from the US 
Army Corps of Engineers’ official library for Engineer Regulation ER1-1-11 
dated June 15, 1995, located at 
http://www.usace.army.mil/publications/eng-regs/er1-1-11/entire.pdf
C# PDF Library SDK to view, edit, convert, process PDF file for C#
load PDF from other file formats; merge, append, and split PDF files; insert, delete, move, rotate, copy and paste PDF file page. C#.NET: Process PDF Image.
copy image from pdf to ppt; preview paste image into pdf
C# PDF remove image library: remove, delete images from PDF in C#.
Text: Replace Text in PDF. Image: Insert Image to PDF. Image: Remove Image from PDF Page. Image: Copy, Paste, Cut Image in Page. Link: Edit URL. Bookmark: Edit
copy image from pdf to; how to copy images from pdf to word
SDEF Overview
Release Notes
6
Primavera’s SDEF Conversion Utilities
In Primavera’s P6 Project Management module, you can exchange project data 
with other Primavera users by converting projects to Primavera’s Proprietary 
Exchange Format (XER). Using Primavera’s import/export capability, you can 
then convert an XER file an SDEF data file, and vice versa. Primavera P6 
converts data between the XER and SDEF formats using the following utilities:
ɾ
SDEF to XER (P330XERConvert.exe)
ɾ
XER to SDEF (XERP330Convert.exe)
Use Primavera’s SDEF conversion capabilities when you want to
ɾ
exchange project data with contractors and owners who do not use 
Primavera products.
ɾ
provide project data in the SDEF format whenever required by your contract.
Conversion Considerations
Release Notes
7
Conversion Considerations
Primavera P6 projects can store far more data than the SDEF specification 
requires. For example, the SDEF file structure allows for only one application of 
a resource per activity, while P6 enables you to apply a resource to an activity 
repeatedly using resource lags and durations.
P6 projects intended for use with the SDEF interface should comply with the 
SDEF specification. You should not utilize the additional capabilities that P6 
offers because the SDEF file structure cannot store the additional data.
The following are items to consider when exchanging data between the XER and 
SDEF formats:
ɾ
Activity descriptions:  The SDEF file structure only allows activity 
descriptions up to 30 characters long. When converting XER files to SDEF, 
only the first 30 characters of the description are exported.
ɾ
Activity IDs:  The SDEF standard does not support activity IDs longer than 
ten characters, while P6 projects may contain activity IDs longer than ten 
characters. Activity IDs are truncated to the first ten characters when 
converting a P6 project to SDEF. Due to this truncation, it is possible that 
duplicate activity IDs will be encountered during the conversion; if so, the 
conversion is aborted. To ensure that conversions to SDEF are not aborted, 
P6 projects should not contain activity IDs longer than ten characters. If 
activity IDs must be longer than ten characters in P6, the first ten characters 
must be unique.
ɾ
Activity limit:  SDEF files cannot contain more than 10,000 activities. 
When converting XER files to SDEF, only the first 10,000 activities are 
exported.
ɾ
Activity totals:  The SDEF file structure does not store individual resource 
budgets as P6 does. Instead, SDEF stores total budgeted cost and total 
budgeted units for each activity. The conversion utility totals costs and units 
for each activity’s resources in conformance with the SDEF standard.
Conversion Considerations
Release Notes
8
ɾ
Calendars: Calendars in SDEF are only one character; therefore, calendar 
names from P6 are truncated to one character.  You are limited to 36 
calendars in SDEF (A through Z and 0 through 9).
ɾ
Cost per unit:  The SDEF standard uses a calculated cost per unit for each 
activity defined as the activity’s budget cost divided by its budget quantity. 
Primavera’s SDEF conversion conforms to this standard.
ɾ
Data mapping:  The following table describes how some P6 data is 
converted to SDEF:
ɾ
Durations:  The SDEF standard does not support durations longer than 999 
days. If your P6 project contains durations longer than 999 days, these 
durations will convert to zero in the SDEF file.
ɾ
Expenses:  The SDEF standard does not support expenses, so expenses are 
not exported to SDEF.
ɾ
Milestones:  The SDEF standard does not recognize milestones as activities. 
If your P6 project uses milestones, the converter stores these as zero-
duration activities.
SDEF Field
P6 Field or Calculation
Total Qty
Budgeted Units for the activity assignment
Cost Per Unit
Budgeted Cost divided by the Budgeted Units for 
the activity assignment
Qty to Date
Actual Units for the activity assignment
Activity Cost
Budgeted Cost for the activity assignment
Cost to Date
Actual Regular Cost for the assignment plus the 
Stored Material Cost (STMA) for the activity
Note: The Stored Material Cost is derived from 
the Activity UDF named 'STMA'. Refer to the 
“Required User-defined Field (STMA)” bullet 
item on the previous page for more information.
Conversion Considerations
Release Notes
9
ɾ
Required User-defined Field (STMA):  SDEF files store activity stored 
material cost data in a field named STMA. This field does not exist in P6. 
When converting an SDEF file to XER, if the STMA field does not exist as a 
UDF in the Project Management module project, it will be automatically 
created during the import process. If the STMA UDF was previously defined 
in a project (to be used for a different purpose), you should rename the 
preexisting UDF before importing an SDEF file.
To store this data in a Project Management module project before you 
convert it to SDEF, you must create an Activity UDF named 'STMA'. This 
UDF must have a Data Type of Cost. If you do not create this UDF, the 
STMA field will be blank when you convert an XER file to an SDEF file.
ɾ
Required User-defined Fields (Contract Number and Contractor 
Name):  SDEF files contain fields named Contract Number and Contractor 
Name. These fields do not exist in the Project Management module. When 
converting an SDEF file to XER, if the Contract Number and Contractor 
Name fields do not exist as user-defined fields (UDFs) in the Project 
Management module project, they will be automatically created during the 
import process. If the Contract Number and Contractor Name UDFs were 
previously defined in a project (to be used for a different purpose), you 
should rename the preexisting UDFs before importing an SDEF file. 
To store this data in a Project Management module project before you 
convert it to SDEF, you must create Project UDFs named 'Contract Number' 
and 'Contractor Name'. These UDFs must have a Data Type of Text. If you 
do not create these UDFs, the Contract Number and Contractor Name fields 
will be blank when you convert an XER file to an SDEF file.
In SDEF files, values in the Contract Number field cannot be longer than six 
characters. When a Contract Number UDF value is more than six characters, 
this value is truncated to the first six characters when you convert to SDEF.
ɾ
Suspend and resume dates:  The SDEF standard does not recognize 
suspend and resume dates, so suspend and resume dates are not exported to 
SDEF.
Conversion Considerations
Release Notes 10
Activity Code Structure Requirements
The US Army Corps of Engineers requires all projects to use a predefined 
activity code structure. This structure specifies the name and maximum length of 
each activity code in the project. The SDEF format adheres to this structure; 
therefore, all P6 projects being exported to SDEF format must have an activity 
code structure that exactly matches the predefined structure.
The following table shows the required activity code structure:
Note: The Description column is for your information only. The Project 
Management module does not support activity code descriptions. When 
creating the activity code structure, you only need to create each code 
and specify the maximum length. You also need to make sure you define 
each activity code as a global activity code.
Note: When converted, the code value for the “Feature of Work” activity 
code displays in the Activity Codes Description column of the XER file, 
and a unique code value is generated by the converter. For all other 
activity codes, the code value displays in the Activity Codes Code Value 
column of the XER file.
Code 
Max 
Length
Description
WRKP
3
Workers per day
RESP
4
Responsibility
AREA
4
Area
MODF
6
MOD or Claim #
BIDI
6
Bid Item
PHAS
2
Phase
CATW
1
Category of work
FOW
30
Feature of work
Documents you may be interested