CHAPTER 3
OPERATION
The UCM and NVM (Nonvolatile Memory)
256K (24C256)
34
Ultra II
64K (24C64)
31
OPTimum II
256K (24C256)
24
ULTRA I
64K (24C64)
18
PRO I
32K (24C32)
17
ENTRY I
NVM capacity (KBits)
File System
Comfort Model
Table 3.1 - NVM Types
The above table shows the types of NVMs used for the various
Comfort Models (Entry, Pro, and Ultra). In Comfort, the NVM in U4
contains the programmed configuration, which is downloaded from
the PC using Comfigurator, or programmed using the keypad or
telephone using the Engineer Menu.
Comfigurator Download and Upload
In Comfigurator, select Options > Communications and select the
COM port (1 to 16), (or IP Address and Port in the case of
UCM/Ethernet)  to which the UCM is connected.
To transfer the programmed configuration to Comfort (“download”),
in Comfigurator, select Transfer > PC to Comfort. To transfer the
programmed configuration from Comfort to the PC, select Transfer
 Comfort to PC.
During Upload and Download, both D11 (Green) and D12 (Red)
Leds will be blinking rapidly indicating data received and
transmitted to the RS232 port. D9 and D10 LEDs will also be
blinking fast simultaneously. Keypads and other modules will not be
able to communicate during this process.
Refer to the Comfigurator Reference Manual for details on using he
software. Refer to Programming with Comfigurator for Comfort  
programming concepts.
Master and Copy NVMs
IC sockets U2 and U3 are meant for the NVMs for the COPY,
COMPARE, TEST, UPLOAD and DOWNLOAD operations. The
designation of “Master” depends on the J4 jumper setting. If the
shunt in J4 is inserted in the position which is closer to U2, then U2
will be designated the Master and U3 the Copy. Similarly, if the
shunt in J4 is inserted in the position which is closer to U3, then U3
will be designated the Master and U2 the Copy.
The NVMs should be inserted in U2 and U3 with the UCM
disconnected from Comfort (i.e. with power removed).
Universal Communications Module
11
Pdf link - insert, remove PDF links in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Free C# example code is offered for users to edit PDF document hyperlink (url), like inserting and deleting
add hyperlink pdf; add links in pdf
Pdf link - VB.NET PDF url edit library: insert, remove PDF links in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Help to Insert a Hyperlink to Specified PDF Document Page
adding hyperlinks to pdf documents; add hyperlink to pdf acrobat
Copy “Master” to “COPY” 
1. With the UCM disconnected from Comfort (i.e. with power
removed), insert the NVMs into Master and Copy sockets U2
and U3. The NVMS should have identical memory capacities, or
the COPY NVM could have a greater capacity than the Master
NVM.
2. Insert the shunt in J4 so that it is closer to the “Master” NVM
and away from the “Copy” NVM.
3. Connect the 4 way cable between JP2/JP2A on the UCM and J15
on Comfort. The RDY LED should turn on and D9 and D10 leds
should start flashing.
4. Press the “COPY” button. The “RDY” LED should turn off, and
the BUSY1 led should turn on while the copy operation is in
progress. 
5. When the COPY operation is completed, the BUSY1 led turns off,
and the BUSY2 led turns on during the compare phase while the
MASTER and COPY NVMs are being compared.
6. When the Compare operation is completed, the RDY led turns
on and the BUSY leds turn off.
7. If an error is encountered during the COPY or COMPARE
operation the Error led turns on.
8. Remove power from the UCM by unplugging the 4-way cable
from either Comfort or the UCM. Before removing the NVMs.
Compare “Master”  with “COPY” 
1. With the UCM disconnected from Comfort (i.e. with power
removed), insert the NVMs into Master and Copy sockets U2
and U3. The NVMs should have identical capacities.
2. Insert the shunt in J4 so that it is closer to the “Master” NVM
and away from the “Copy” NVM.
3. Connect the 4 way cable between JP2/JP2A on the UCM and J15
on Comfort. The RDY LED should turn on and D9 and D10 leds
should start flashing.
4. Press the “COMPARE” button to  start the compare operation.
The RDY and ERROR leds turn off and the “BUSY 2” led turns
on.
5. If the compare is successful, the RDY led turns on and the
BUSY2 led turns off. If the two NVMs are not identical, the ERR
led turns on.
Upload Comfort NVM (U4) to “COPY”
1. With the UCM disconnected from Comfort (i.e. with power
removed), insert the NVM into either of sockets U2 and U3. The
NVM should have the same or greater capacity than the NVM in
U4 of Comfort.
Universal Communications Module
12
RasterEdge .NET Document Imaging Trial Package Download Link.
View & Process. XImage.Raster. Adobe PDF. XDoc.PDF. Scanning. XImage.OCR. Microsoft Office. View & Process. XImage.Raster. Adobe PDF. XDoc.PDF. Scanning. XImage.
convert doc to pdf with hyperlinks; add email link to pdf
C# PDF Library SDK to view, edit, convert, process PDF file for C#
RasterEdge PDF SDK for .NET package offers robust APIs for editing PDF document hyperlink (url) and quick navigation link in PDF bookmark.
adding hyperlinks to a pdf; add url pdf
2. Insert the shunt in J4 so that it is away from the “Copy” NVM to
which the program in Comfort is to be uploaded. Note: In this
context “Upload” means to transfer from Comfort to UCM and
“Download” means to transfer from UCM to Comfort.
3. Connect the 4 way cable between JP2/JP2A on the UCM and J15
on Comfort. The RDY LED should turn on and D9 and D10 leds
should start flashing.
4. Press the UPLOAD button. All the data in Comfort’ s  U4 NVM
will be uploaded into the COPY NVM. The RDY led should go off
and the BUSY1 led should come on during the upload operation
5. The upload operation should take about 30 seconds for a
24LC32 (for FS17) and 60 seconds for a 24C64 (for FS31), and
up to 4 minutes for 24C256 (for FS34).
6. When the upload is completed, the RDY led should come on and
the BUSY1 led should go off.
Download “Master” NVM to Comfort NVM (U4)
1. With the UCM disconnected from Comfort (i.e. with power
removed), insert the Master NVM into either of sockets U2 and
U3. The NVM should have the same  capacity as the NVM in U4
of Comfort.
2. Insert the shunt in J4 so that it is towards the “Master” NVM
containing the program is to be downloaded to Comfort: In this
context “Upload” means to transfer from Comfort to UCM and
“Download” means to transfer from UCM to Comfort.
3. Connect the 4 way cable between JP2/JP2A on the UCM and J15
on Comfort. The RDY LED should turn on and D9 and D10 leds
should start flashing.
4. Press the DOWNLOAD button. All the data in the Master NVM
will be downloaded into Comfort’s NVM. The RDY led should go
off and the BUSY1 led should come on during the upload
operation.
5. The download operation should take about 30 seconds for a
24LC32 (for FS17) and 60 seconds for a 24C64 (for FS31), and
up to 4 minutes for 24C256 (for FS34).
6. When the download is completed, the RDY led should come on
and the BUSY1 led should go off.
7. The UCM resets Comfort automatically after a DOWNLOAD.
Test  NVM
1. With the UCM disconnected from Comfort (i.e. with power
removed), insert the NVM to be tested into the U2 or U3 socket
and insert the shunt in J4 AWAY from the NVM to be tested.
Do this without power applied.
2. Connect the UCM to Comfort  and press the TEST button. Every
location will be written and read to ensure that the device is
working. After testing, the original data in the NVM is restored.
Universal Communications Module
13
How to C#: Basic SDK Concept of XDoc.PDF for .NET
XDoc.PDF for .NET allows C# developers to edit hyperlink of PDF document, including editing PDF url links and quick navigation link in bookmark/outline.
adding links to pdf document; active links in pdf
VB.NET PDF: Basic SDK Concept of XDoc.PDF
XDoc.PDF for .NET allows VB.NET developers to edit hyperlink of PDF document, including editing PDF url links and quick navigation link in bookmark/outline.
convert excel to pdf with hyperlinks; check links in pdf
The RDY led should go off and the BUSY1 led should come on
during the TEST operation
3. When the test operation is completed, the RDY led should come
on and the BUSY1 led should go off.
Universal Communications Module
14
C# Raster - Raster Conversion & Rendering in C#.NET
adding a link to a pdf; add links to pdf file
VB.NET Word: How to Process MS Word in VB.NET Library in .NET
Besides, here is the quick link for how to process Word document within We are dedicated to provide powerful & profession imaging controls, PDF document, image
add hyperlink pdf document; add link to pdf acrobat
CHAPTER 4
TROUBLESHOOTING
Common Problems
Serial Port
The most common problem with UCM communications is with the
serial port on the computer. Make sure that the UCM is connected to
the correct COM port, and that same port is specified in the Serial
Port setting for Comfigurator.
There may be compatibility problems with certain USB to Serial and
PC-Card to serial converters. These need to be tested with the UCM.
UCM ID
Check that there is no other UCM (UCM05, UCM/Audio,
UCM/Ethernet, UCM/CBUS, UCM/EIB, UCM/Smartfit) installed with
the same ID as any other UCM. This will cause a conflict of
addresses with more than 1 UCM responding to the poll from
Comfort.
SW8 Settings
SW8-F must be open for normal UCM, UCM05, UCM/Audio, and
closed for UCM/Ethernet.
SW8-G should normally be open.
SW8-H should be open for No Flow Control
LED Status Indications
The following describes what is regarded as normal LED indications
which will be seen on the UCM module when it is connected to  
Comfort.
D10 (green)
KA/KB or 12V/Ground not connected 
Cause
No Communications
D9 (Red)
zzzzzzzzzzzzzzzzzzzzzzzzz
D10 (green)
UCM SW7 ID shunts may be set wrongly or
No of UCMs in Comfigurator may be wrong.
Cause
UCM is receiving data, but not responding. 
z z z z z z z z z z z z
D9 (Red)
zzzzzzzzzzzzzzzzzzzzzzzzz
D10 (green)
Communications OK (Idle)
D9 (Red) and D10 (green) status indications for RS485
Universal Communications Module
15
VB.NET PDF: Create PDF Document Viewer in C#.NET for Document
reading PDF document in ASP.NET web, .NET Windows Forms and mobile developing applications respectively. For more information on them, just click the link and
add url pdf; add link to pdf file
VB.NET Word: VB Code to Create Word Mobile Viewer with .NET Doc
For the respective tutorials of these Document or Image Mobile Viewer in VB.NET prorgam, please link to see: PDF Document Mobile Viewer within VB.NET
convert doc to pdf with hyperlinks; active links in pdf
D9 (Red)
D9 (Red) and D10 (green) status indications for RS485
The D10 (green) LED indicates RS485 data received from Comfort,
and D9 (Red) indicates data transmitted to Comfort.
z
D12 (Red)
D11 (green)
UCM sends a report to RS232
D12 (Red)
z
D11 (green)
UCM receives command from RS232 and does not Respond
z
D12 (Red)
D11 (green)
UCM receives command from RS232 and Responds (e.g... login)
z z z z z z z z z z z z z
D12 (Red)
z z z z z z z z z z z z z
D11 (green)
Uploading or Downloading from PC (Comfigurator)
D12 (Red) and D11 (green) status indications for RS232
The D11 (green) LED indicates RS232 data received from the PC
and D12 (Red) indicates RS232 data transmitted to  the PC.
Universal Communications Module
16
z
D12 (Red)
D11 (green)
UCM sends a report to RS232
D12 (Red)
z
D11 (green)
UCM receives command from RS232 and does not Respond
z
D12 (Red)
D11 (green)
UCM receives command from RS232 and Responds (e.g... login)
z z z z z z z z z z z z z
D12 (Red)
z z z z z z z z z z z z z
D11 (green)
Uploading or Downloading from PC (Comfigurator)
RDY, BUSY1, BUSY2, ERROR LED Indicators
Using Hyperterminal for Testing
This section shows how to communicate with the UCM using a PC
serial port. This is useful for those who are developing applications
for the UCM, or for those who have difficulty getting Comfigurator
to work with the UCM. Connect the UCM to Comfort and the PC
serial port as described earlier. On Windows 95/98/2000/Me, Run
Hyperterminal on the PC. This can be found at Start -> Programs  
-> Accessories -> Communications -> Hyperterminal Folder.
Double-click on the Hyperterminal.exe icon. A dialogue box for
“New Connection” will appear  as  shown below. Enter “UCM on
COM1 (or 2)” as the name and click on OK
The next screen is:
Universal Communications Module
17
On the box “Connect using, select “Direct to COM n” (where n is
your serial COM port to which you are connecting the UCM). Click
on OK
The next screen defines the properties of the COM port
Universal Communications Module
18
Set “Bits per second” to 9600, Data Bits” to 8, “Parity” to one, “Stop
Bits” to 1, “Flow Control” to Hardware and click on OK. This starts
the Communication screen
Universal Communications Module
19
On the Menu bar, select File -> Properties, and click on the
“Settings”  tab, and click on “ASCII Setup..”, and check the boxes
as shown below:
Click on OK, and OK again until you get back to the Hyperterminal
window. On the Menu bar, select View -> Font, and select Font =
Terminal, Font = Regular, size=9.
Universal Communications Module
20
Documents you may be interested