pdfsharp c# example : Add links to pdf online Library SDK component .net wpf windows mvc ucmman2-part314

Click on OK. You can now send characters to the UCM according to
the RS232 command protocol. Start with
<Control-C>LI1234<Enter> which is the login code assuming 1234
is a valid user code.  On Windows 95, you can see the text which
you type, but on Windows 98, you are not able to see your text
entry for some reason. <Control-C>, the Start character appears as
a heart symbol. You should get the reply LU01, which is Login User
1
Universal Communications Module
21
Add links to pdf online - insert, remove PDF links in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Free C# example code is offered for users to edit PDF document hyperlink (url), like inserting and deleting
adding a link to a pdf; add email link to pdf
Add links to pdf online - VB.NET PDF url edit library: insert, remove PDF links in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Help to Insert a Hyperlink to Specified PDF Document Page
add hyperlinks to pdf online; adding links to pdf document
This shows that the communications with the UCM is working. Type
<Control-C>SR01<Enter> to enable status reporting from the UCM.
Now arm the Comfort system by pressing the AWAY button and
close the door. When Comfort arms the Hyperterminal window will
show;
The meaning of the messages is as follows:  IP0101 means Input 1
On (Open)
IP0100 means Input 1 Off (Closed)
MD015A means Security Mode 1 (Away Mode) by user 90 (5A in
hexadecimal notation). User 90 means one-touch armed by keypad
without any user code
AM095A means System Alarm 9 (System armed) by user 90. 
AL13 means Alarm Type 19 (13 is hexadecimal notation for 19
decimal)
When you are finished, save the session (File -> Save as ->
UCM.ht) so that you can recall the Hyperterminal settings without
having to go through the whole procedure again.
Universal Communications Module
22
C# PDF Convert to HTML SDK: Convert PDF to html files in C#.net
HTML converter toolkit SDK, preserves all the original anchors, links, bookmarks and to Use C#.NET Demo Code to Convert PDF Document to Add necessary references
add url to pdf; adding a link to a pdf in preview
.NET PDF Document Viewing, Annotation, Conversion & Processing
Edit, delete text from PDF. Insert images into PDF. Edit, remove images from PDF. Add, edit, delete links. Form Process. Fill in form data programmatically.
add hyperlinks pdf file; add hyperlink pdf file
CHAPTER 5   INFRARED LEARNING
Infrared Learning
The Comfort Infrared learning software is a Windows 
TM
application
running on the UCM05 with IR receiver to learn new infrared signals
and save the codes in the .ifr file format which is used by
Comfigurator.
infrared.exe runs on an IBM PC-compatible computer running on  
Windows 98, Windows ME, Windows NT4, Windows 2000 or
Windows XP. It requires a UCM05 (Universal Communication
Module) RS232 interface connected to one of the computer's COM
ports to interface to the Comfort control panel.
Installation
The program is included with the Comfigurator software which is
supplied on a CD or downloaded from the Internet from the Cytech
Technology web site. (www.cytech-technology.com) or Comfort
distributors websites. Infrared.exe is also available as a standalone
program which can be downloaded from the Cytech web site. 
There is no installation required. The infrared.exe program must be
in the Comfigurator directory so that it can work with the ifr files.
To start the program, run infared.exe or start it from Comfigurator
in Tools > Infrared Utility
Definitions
Ifr file
A .ifr file contains the encoded infrared data for the commands for a
specific appliance. For example, a TV file may have On/OFF,
Channel 1, Channel 2, Mute, etc.. Each command in the ifr file can
be assigned as an IR Transmit code and downloaded to Comfort via
Comfigurator to be sent to any output using action 129.
The commands in an ifr file can be learned with the infrared learner
software.
The .ifr files are contained in the ifr subdirectory in the
Comfigurator directory.
Specification
Infrared Carrier Frequency: 35 kHz to 50 kHz
Learning distance: 5 to 10 cm.
Angle for reception: +/- 25 degrees
Encoding: ifr format
Universal Communications Module
23
VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.
Turn PDF images to HTML images in VB.NET. Embed PDF hyperlinks to HTML links in VB.NET. Convert PDF to HTML in VB.NET Demo Code. Add necessary references:
pdf link to email; pdf links
C# PDF Convert to Word SDK: Convert PDF to Word library in C#.net
the original text style (including font, size, color, links and boldness). C#.NET DLLs and Demo Code: Convert PDF to Word Document in C# Add necessary references
add links to pdf file; adding hyperlinks to a pdf
Limitations and Disclaimer
Some infrared signals cannot be captured or encoded by the
software algorithm or used by Comfort because of limitations in the
encoding system.  The IR learner captures and encodes the IR
signals, while Comfort decodes the encoded signals to transmit from
any programmed output. The process of encoding and decoding will
introduce errors between the reconstructed signal and the original
signal. This works well in the majority of remote control signals
tested, but not for all possible remote controls.
Cytech Technology makes no claim about the efficacy of this device
or software to capture, encode or transmit any specific Infrared
signal.
Operation
Run the infrared learning program by double-clicking on
infrared.exe or from Comfigurator > Tools > Infrared Utility. 
The opening screen is shown below
To start learning IR signals for a new device which is not in the IR
code library (in the ifr subdirectory), press New... You will be asked
for the Brand, Device and Model number as in the screen below;
Universal Communications Module
24
C# Create PDF Library SDK to convert PDF from other file formats
PDF with a blank page, bookmarks, links, signatures, etc. PDF document in C#.NET using this PDF document creating toolkit, if you need to add some text
pdf hyperlinks; clickable links in pdf
C# Image: Tutorial for Document Management Using C#.NET Imaging
more detailed C# tutorials on each part by following the links respectively are dedicated to provide powerful & profession imaging controls, PDF document, image
change link in pdf; add hyperlink in pdf
Press OK to confirm. This defines the filename for the ifr file which
is to be generated.  You can now start to learn new functions using
the remote control.
To learn new IR codes for devices currently in the ifr directory click
on the arrow to the side of the window and select from the
drop-down list of appliances shown.
The above screen example for Mitsubishi VCR shows the learned
commands for this device in the bottom screen.
Rename
You can rename the function by selecting it with the cursor and
pressing the Rename button.
Universal Communications Module
25
VB.NET PDF: Basic SDK Concept of XDoc.PDF
You may add PDF document protection functionality into your VB.NET program. to edit hyperlink of PDF document, including editing PDF url links and quick
add hyperlink to pdf in preview; add a link to a pdf in acrobat
How to C#: Basic SDK Concept of XDoc.PDF for .NET
You may add PDF document protection functionality into your C# program. to edit hyperlink of PDF document, including editing PDF url links and quick
add a link to a pdf file; chrome pdf from link
Remove
You can delete  the function by selecting it and pressing the
Remove button.
Add
To learn a new infrared code, click on the ADD.. button
Enter the Function Name for the command, e.g.. Play, Stop, On, Off
etc.. The SERIAL PORT field will become visible. Change the COM
port number if necessary. Click on “Capture Signal” to start the
capture.  
Always use new batteries on the remote control, as
this gives the best chance of successfully capturing the
signal.
Universal Communications Module
26
When the screen above appears, point the remote control directly at
the IR receiver LEDs U8 and U9 about 5 to 10  cm away. Do not
place the remote control too close to the UCM board because  
the exact  location infrared transmitting LED of the remote
control behind the lens may not be known. Press and release
the button on the remote control which is to be learned. Do not
keep pressing the button unless it is required, e.g.. for dimming
lights. The BUSY1 Red LED will turn on when the UCM05 is waiting
for an infrared signal to learn. If a valid infrared signal is not
received within 20 seconds, the screen will time-out.
If the capture is complete, the BUSY2 Red LED will blink, followed
by the D12 Red LED (to indicate that the information was sent to
Comfigurator) and the following screen  will appear.
Universal Communications Module
27
This shows the waveform of the captured IR code. The numbers on
the horizontal scale show the time in milliseconds. 
Resolution
The Resolution window on the top right allows you to specify
different scales to observe the infrared signal.  The selection does
not change the signal in any way, just the magnification of the
signal on the screen.
Tolerance
The Tolerance window  allows you to specify the tolerance which the
encoding algorithm uses. The IR signal is encoded in the Comfort ifr
format, so that the space required in Comfort’s memory is
minimized. In encoding the signal using the IR learner and decoding
Universal Communications Module
28
the encoded code in Comfort, there will be differences between the
original IR signal and the reconstructed signal transmitted from
Comfort. These differences are in the length of the pulses and the
gaps in the captured waveforms as well as the carrier frequency.
Specifying a larger tolerance may allow the algorithm to encode the
signal more efficiently, resulting in fewer bytes required for the
signal. Comfort imposes a limit on the size of the encoded IR signal
due to memory limitations. For Outside firmware the limit is 96
bytes while for Entry firmware, the limit is 50 bytes. Although the
IR Learner software is able to capture and encode signals which are
greater than 96 bytes, Comfort will not be able to decode and
transmit these signals.  Specifying a larger tolerance may result in a
code which is less than the limit allowed.  However, applying too
large a tolerance could result in incorrect encoding of the signal.
Encode
Press the ENCODE button to initiate the encoding process. The
screen below shows a typical result;
The number of encoded bytes is shown at the end of the data in the
above window. To save the code into the .ifr file,  click on the YES
button.  The encoded data is saved as an ifr file. The filename is
automatically generated from the equipment type, manufacturer,
and model number which was entered earlier.
Clicking on the NO button will return to the previous screen where a
different tolerance can be specified.
Crop
Universal Communications Module
29
The Crop button on the waveform display screen allows you to
delete the last part of the signal in order to achieve a code size
within the limit. Some IR codes have single or repeated pulses at
the end of the signal which may not be needed to achieve the
function. The presence of these pulses defeats the algorithm which
looks for repetitions of patterns in the signal. If a pattern is
repeated in the signal, but followed by some pulses which are part
of the pattern, then the entire signal cannot be coded as a
repetition. To crop a signal,  click on the point in the signal after
which the signal is to be cropped. The remaining part of the signal
before the cursor will be acted upon by the encoding algorithm.
Save To File
This button saves the waveform in .raw format. This file can then be
sent to Cytech Technology (email:
techsupport@cytech-technology.com with full details) for analysis  
in case of problems with encoding.  This does not save the
encoded file in the .ifr format
Infrared Learning Errors 
“Infrared Signal is too long”
If this message appears before the remote control button is
pressed during learning, it means that random IR signals are being
received. This could be due to certain types of fluorescent lightsTry
again with the lights  off or in another room.
If the error message is seen after the infrared signal is sent, it
means that the signal being learned is too long for the system to
encode, probably because it has an unusual format. The UCM05 is
not able to encode all types of  remote controls
“Erroneous signal or Out of Frequency Range Detected”
This message may received if the remote control is not pointed
directly at the receivers or is too far away. The  remote control
should be pointed directly at the infrared receivers U8 and U9 at a
distance of 5 to 10 cm away.
Some remote controls operate outside the frequency range of 35 to
50 kHz in which the receiver can detect. Such infrared signals
cannot be learned by the UCM05.
“Infrared Signal is Too Long”
This may be cause by pressing and holding the remote control
button. Try again after clicking the “Capture” button, by pressing
and releasing the button.
However a small percentage of infrared signals are really too long to
be learned by the UCM05.
“Error Encountered during Encoding - Exceeded Bytes”
Universal Communications Module
30
Documents you may be interested
Documents you may be interested