Bose
®
Modeler
®
6.5 Software Tutorial
Chapter 5: Predicting Sound                               111
4.   As you can see in Figure 5.38, sound is arriving at the Sample 
tool location from Cluster 2 first (notice the selected pin and its 
corresponding trace on the coverage map).
Humans localize sound based on the first arrival that they hear.  
Cluster 1 is closest to where a talker or music presentation 
would be located, so the audience should hear their first sound 
arrivals from Cluster 1, not Cluster 2. Because listeners in the 
back of the church are closer to Cluster 2, sound from these 
loudspeakers would normally reach them first. To prevent this, a 
signal delay should be set on the loudspeakers in Cluster 2 so 
that all listeners in the church receive sound from Cluster 1 first.
5.   Click the Loudspeakers tab in the Detail window and scroll to 
the right until you can see the Delay column.
6.   Enter a delay of 45 (ms) for the three loudspeakers in Cluster 2.
7.   Notice that the time-arrivals in the Time Resp. tab have 
changed, and the first sound arriving at the Sample tool location 
is now from Cluster 1.
Figure 5.39 - After a delay of 45 (ms) is set, sound arrives from 
Cluster1 first
Pdf email link - insert, remove PDF links in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Free C# example code is offered for users to edit PDF document hyperlink (url), like inserting and deleting
add links to pdf acrobat; add links to pdf online
Pdf email link - VB.NET PDF url edit library: insert, remove PDF links in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Help to Insert a Hyperlink to Specified PDF Document Page
add links in pdf; add links pdf document
Bose
®
Modeler
®
6.5 Software Tutorial
112                                                 Chapter 5: Predicting Sound
The Frequency Response tab
The Freq. Resp. tab displays dB SPL on the vertical axis, and the 
frequency spectrum on the horizontal axis. The frequency 
response at a specific location in the coverage map can be 
displayed by placing the Sample tool at the desired location.
Follow these steps to display a frequency response:
1.   Click the Freq. Resp. tab.
2.   Select the Sample tool in the Draw toolbar.
3.   Click inside the Speech Intelligibility coverage map in the 
Modeling window. Notice that data appears in the Freq. Resp. 
tab.
4.   Drag the sample tool around the model. Because frequency 
response is position-dependent, the data changes as you 
change the location of the Sample tool.
Drag the Sample tool over each of the listener locations in the 
model. The Sample tool snaps to the listener location when you 
drag the tool near a listener. As you make changes to your sound 
system, these listener locations allow you to return to a specific 
and consistent location in the model to evaluate acoustic 
prediction.
Figure 5.40 - Freq. Resp. tab
Note:  You can change the smoothing of the frequency 
response curve by right-clicking in the Freq. Resp. tab and 
choosing a different octave value. Lower values produce finer 
resolution.
RasterEdge.com General FAQs for Products
copy and email the secure download link to the assistance, please contact us via email (support@rasteredge & profession imaging controls, PDF document, image to
adding links to pdf in preview; clickable links in pdf
RasterEdge Product Licensing Discount
s). After confirming the informations provided, we will send you an email that contains price(s) at a discount and the online order link for new licensing.
pdf links; pdf edit hyperlink
Bose
®
Modeler
®
6.5 Software Tutorial
Chapter 5: Predicting Sound                               113
The Modulation Transfer Function (MTF) tab
The STI is calculated using band limited noise in seven octave 
bands. Each band is modulated at 14 different frequencies 
between 0.63 and 12.5 Hz. Each of these curves represents the 
one of the seven octave bands, and is called an MTF curve 
(Modulation Transfer Function).
The MTF is a graphic description of the Speech Transmission 
Index calculation and tells us how well the speech was preserved 
when it arrived at the listener after leaving the loudspeaker and 
traveling through the room. If the signal is perfect upon arrival it 
would be a flat line at the top (100% intelligible = 1.0); if it were 
totally degraded it would be a flat line at the bottom (0% intelligible 
= 0.0). By looking at the shape of the MTF curve we can determine 
the probable cause of reduced intelligibility.
The MTF is color coded 125 Hz to 4 kHz, using Roy G. Biv 
(Sequence of hues in the visible spectrum).
Follow these steps to view MTF data:
1.   Select the Speech tab in the Modeling window to display the 
Speech Intelligibility coverage map.
2.   Click the MTF tab in the Data window.
Figure 5.41 - MTF tab
Note:  You can copy a graph or the data into Excel by 
right-clicking in the graph window and selecting either Copy 
Graph or Copy Data.
RasterEdge Product Renewal and Update
4. Order email. Our support team will send you the purchase link. HTML5 Viewer for .NET; XDoc.Windows Viewer for .NET; XDoc.Converter for .NET; XDoc.PDF for .NET;
accessible links in pdf; pdf reader link
VB.NET Create PDF from PowerPoint Library to convert pptx, ppt to
Link: Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete Metadata. Form Process. Create PDF file from PowerPoint free online without email.
add page number to pdf hyperlink; change link in pdf file
Bose
®
Modeler
®
6.5 Software Tutorial
114                                                 Chapter 5: Predicting Sound
Here are some beginning guidelines for understanding the MTF 
data:
Figure 5.42 - A reduced MTF due to Background Noise
Figure 5.43 - A downward sloping MTF caused by reverberation
Background Noise:
Has the effect of reducing the entire MTF, 
independent of modulation frequency. The 
lines would both start and end lower on the 
graph.
Reverberation:
Has the effect of gradually decreasing the 
modulation as the modulation frequency 
increases. The MTF that results from high 
reverberation levels will slope continuously 
downward. Higher reverberation times 
cause the curve to decrease more rapidly.
VB.NET Create PDF from Word Library to convert docx, doc to PDF in
Link: Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete Metadata. Form Process. Free online Word to PDF converter without email.
add links to pdf; clickable pdf links
VB.NET Create PDF from Excel Library to convert xlsx, xls to PDF
Link: Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete Metadata. Form Process. Convert Excel to PDF document free online without email.
add a link to a pdf in acrobat; change link in pdf
Bose
®
Modeler
®
6.5 Software Tutorial
Chapter 5: Predicting Sound                               115
Figure 5.44 - A notched MTF caused by late reflections
Late-arriving 
reflections:
Have the effect of putting a notch in the 
MTF. The later the reflection, the lower the 
modulation frequency at which the notch 
occurs.
Tip:  The notch is located at a frequency, f where
where
is the time difference between the two arrivals causing the 
echo. If you see a dip at 5 Hz, look at 2 arrivals spaced by 
roughly 
or 100 ms.
t
f
×∆
=
2
1
∆t
2 5Hz
1
×
VB.NET PDF Convert to Word SDK: Convert PDF to Word library in vb.
Create editable Word file online without email. Supports transfer from password protected PDF. VB.NET class source code for .NET framework.
add link to pdf; adding a link to a pdf
C# PDF Convert to Word SDK: Convert PDF to Word library in C#.net
and .docx. Create editable Word file online without email. Password protected PDF file can be printed to Word for mail merge. C# source
pdf hyperlinks; clickable links in pdf from word
Bose
®
Modeler
®
6.5 Software Tutorial
116                                                 Chapter 5: Predicting Sound
The Statistics tab
The Statistics tab is a histogram that indicates how even the 
coverage data is in a given coverage map. Specifically, the 
Statistics tab is a plot of the normalized frequency of occurrence 
of a particular sound pressure level or STI number (depending on 
what you are evaluating) versus the sound pressure level or STI 
number.
This tab also provides the standard deviation from the average.
1.   Select Direct Field map
2.   Select 1-4 kHz in the frequency drop-down menu.
Figure 5.45 is the Statistics tab for the Direct Field coverage (at 
1-4 kHz) of our sample model. The mean SPL and standard 
deviation are displayed below the graph in the Status Bar.
In the example, the mean is 69.9 and the standard deviation is 
1.8 dB. 95% of the samples fall within +/-2 standard deviations, so 
in this situation 95% of the samples would fall within the range: 
66.3-73.5 dB SPL.
Figure 5.45  - Statistics tab
The standard deviation number displayed in Modeler represents 
the +/- range, in dB, from the mean for one standard deviation. For 
example, if the mean SPL is 80 dB, and the standard deviation is 
6.0 dB, we can assume that 68% of the samples will fall within 
74 and 86 dB. To determine the SPL variance for 95% of the 
samples we simply multiply the standard deviation by 2, since two 
standard deviations represents 95% of the samples.
C# Create PDF from Excel Library to convert xlsx, xls to PDF in C#
Export PDF from Excel with cell border or no border. Free online Excel to PDF converter without email. Quick integrate online C# source code into .NET class.
clickable links in pdf files; check links in pdf
C# Create PDF from PowerPoint Library to convert pptx, ppt to PDF
application. Free online PowerPoint to PDF converter without email. C# source code is provided for .NET WinForms class. Evaluation
add hyperlink to pdf acrobat; active links in pdf
Bose
®
Modeler
®
6.5 Software Tutorial
Chapter 5: Predicting Sound                               117
The SPL tab
The Sound Pressure Level (SPL) tab shows the room frequency 
response, with dB SPL on the vertical axis and the frequency in Hz 
on the horizontal axis.
Figure 5.46 - SPL tab
The SPL tab displays the mean SPL, standard deviation, and 
average total SPL in the status bar below the graph.
The RT
60
tab
RT
60
is a measure of the amount of time it takes for the sound 
pressure level in a room to decay by 60 dB. Modeler software 
displays the predicted RT
60
for the room across the entire 
frequency range in the RT
60
tab.
Note:  The shaded bandwidth region can be dragged across the 
frequency spectrum to display Sound Pressure Levels at 
different frequencies in the Direct or Direct plus Reverberant 
coverage maps.
Bose
®
Modeler
®
6.5 Software Tutorial
118                                                 Chapter 5: Predicting Sound
The RT
60
source (the red sphere in your model which is selected) 
should be located near the primary source of sound in your room 
model. For example, in the tutorial model the RT
60
source should 
be placed just below Cluster 1.
Figure 5.47 - The RT
60
source
Follow these steps to reposition the RT
60
source:
1.   Select the RT
60
source in your model by clicking on it with the 
Select tool. It will highlight in red when selected.
2.   There are 2 ways to position the RT
60
source once it has been 
selected:
•    Drag the purple sphere to the proper location in your 
room, or
•    Click on the Properties tab in the Detail window and enter 
the desired X, Y and Z coordinated for the RT
60
source. In 
this case enter X= -12.0, Y= 0.0, and Z= 5.0.
Note:  To show the measured RT
60
, right-click in the graph 
window and select Measured Reverberation Time.
Bose
®
Modeler
®
6.5 Software Tutorial
Chapter 5: Predicting Sound                               119
The RT
60
curve is displayed in the RT
60
tab in the Data window.  
The vertical axis displays time in seconds and the horizontal axis 
displays frequency: 
Figure 5.48 - RT
60
tab
Changing surfaces and RT
60
The RT
60
(or reverberation time) of the room depends heavily on 
the surface materials in your room model.
Follow these steps to see how changing surface materials affects 
the RT
60
curve:
1.   Click the RT
60
tab to display RT
60
data.
2.   Click the Surfaces tab (in the Data window).
3.   Right-click in the window and confirm Sort > By Number.
4.   Select the surface at the top of the list (Pews - Wooden).
5.   Click the drop-down menu in the Material column and change 
the surface to Carpet - heavy on concrete.
Note:  If you do not see data in the RT
60
tab, the RT
60
source 
may be located outside of your room model, or it is a Model 
where more than 95% of the energy from the RT
60
source is 
removed within three reflections. The source must be located 
inside the walls of your model to provide data. Reposition the 
RT
60
source so that it is inside the room model.
Bose
®
Modeler
®
6.5 Software Tutorial
120                                                 Chapter 5: Predicting Sound
Figure 5.49 - Choosing a different material for a surface
6.   With the first surface still selected in the Surfaces tab, move the 
pointer to the lower right corner of the cell until it changes to a 
double arrow as shown below:
Figure 5.50 - Mouse arrow changes to double arrow pointer
7.   Copy this value to other rows by clicking and dragging the 
double arrow downward until all surfaces are highlighted.
Figure 5.51 - Copying value to all other cells