Setting up security                  Chapter 5 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
111 
To create a Windows-linked user: 
In the Users and Groups folder, right-click the Users folder, select New 
> Windows-Linked User
For details about options in the New Windows-Linked User dialog 
box, click Help
Tip: 
Windows-linked accounts refer to existing Windows 
accounts. If you want to create a new Windows user or 
group, you must do so in Windows. For details, see 
Windows help. 
Creating computer accounts for network 
applications 
For FactoryTalk View SE network applications, in addition to specifying 
which users have access to system resources, you can specify the computers 
where they have access. 
You do this by creating computer accounts, and then associating the user 
accounts with a computer or group of computers, when you set up security 
permissions. 
If you do not want to associate user accounts with specific computers, you 
can use the All Computers account when setting up permissions. This 
account is created automatically at the Network Directory. 
In FactoryTalk View Studio, create computer accounts in the System folder, 
in the Computers and Groups folder. 
The following illustration shows where to find this folder in the Explorer 
window. 
Change link in pdf file - insert, remove PDF links in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Free C# example code is offered for users to edit PDF document hyperlink (url), like inserting and deleting
convert doc to pdf with hyperlinks; add link to pdf
Change link in pdf file - VB.NET PDF url edit library: insert, remove PDF links in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Help to Insert a Hyperlink to Specified PDF Document Page
add links to pdf; adding links to pdf
Chapter 5                  Setting up security 
112 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
Tip: 
The Computers and Groups folder does not exist for a 
local station application. You cannot create computer 
accounts for applications that are confined to a single 
computer. 
To create a new computer: 
In the Computers and Groups folder, right-click the Computers folder, 
and then select New Computer
For details about options in the New Computer dialog box, click Help
To create a new computer group: 
In the Computers and Groups folder, right-click the Computer Groups 
folder, and then select New Computer Group
For details about options in the New Computer Group dialog box, click 
Help
In FactoryTalk View Studio you can set up product and system policies that 
determine general characteristics of the system. 
These specifications are stored at the FactoryTalk Directory and, like all 
settings in the System folder, apply to all FactoryTalk products managed by 
a single Local Directory or Network Directory. 
The following illustration shows you where to find the Policies folder in the 
Explorer window. 
Product policies 
Product policies are sets of features that you can secure for the individual 
products in a FactoryTalk system. 
In FactoryTalk View SE, you can set up product policies for configuring and 
using secure web sites under Internet Information Services. For details, click 
Help in the FactoryTalk View SE Secure Web Site Setup tool. 
Setting up 
system-wide 
policies 
VB.NET PDF File Compress Library: Compress reduce PDF size in vb.
list below is mainly to optimize PDF file with multiple Program.RootPath + "\\" 3_optimized.pdf"; 'create optimizing 150.0F 'to change image compression
add hyperlinks pdf file; pdf links
C# PDF File Compress Library: Compress reduce PDF size in C#.net
list below is mainly to optimize PDF file with multiple Program.RootPath + "\\" 3_optimized.pdf"; // create optimizing 150F; // to change image compression
add links to pdf online; pdf link to specific page
Setting up security                  Chapter 5 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
113 
For more information about product policies, see the FactoryTalk Security 
Help. 
System policies 
In a FactoryTalk View SE application, you can set up the following system 
policies. Local station applications do not contain Health monitoring policies 
or Live Data policies because these apply only to network distributed 
applications. 
FactoryTalk Alarms and Events settings include how to send audit 
messages to the alarm and event history log, whether to send 
suppressed alarms to the alarm history log, options for buffering 
events, and severity ranges associated with each priority category. 
User rights assignment settings determine which users can backup 
and restore FactoryTalk Directory contents, manually switch the 
Active and Standby servers in a redundant server pair, or modify the 
security authority identifier. 
Health monitoring policy settings define system availability 
parameters. These include how often the system checks network 
connections to remote computers, and how long a network disruption 
can last before the system determines that communications have failed. 
Note: Changing health monitoring policy settings can result in 
unexpected behavior. For most networks, the default policy 
settings provide the best results. 
Live Data policy settings determine which communications protocol 
will be used in a FactoryTalk system distributed over a network. 
Note: 
Changing live data policy settings can result in unexpected 
behavior. Do not change the settings in a running production 
system. For changes to take effect, all computers on the 
network must be shut down and restarted. 
Audit policy settings determine what security information is recorded 
while the system is in use. This includes whether FactoryTalk 
Diagnostics logs an audit message when a user attempts an action and 
is allowed or denied access. 
Security policy settings determine general characteristics of security 
accounts and passwords. This includes whether single sign-on is 
enabled, and how many invalid logon attempts are allowed before an 
account is locked out. 
For details about setting up system policies, see the FactoryTalk Security 
Help. 
VB.NET PDF Password Library: add, remove, edit PDF file password
Dim setting As PasswordSetting = New PasswordSetting(newUserPassword, newOwnerPassword) ' Change password for an encrypted PDF file and output to a new file.
add links to pdf in acrobat; add hyperlink to pdf online
C# PDF Password Library: add, remove, edit PDF file password in C#
PasswordSetting setting = new PasswordSetting(newUserPassword, newOwnerPassword); // Change password for an encrypted PDF file and output to a new file.
pdf link to email; add hyperlink in pdf
Chapter 5                  Setting up security 
114 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
FactoryTalk Security manages security for system resources including the 
FactoryTalk Directory, the application, areas within the application and their 
contents, and the System folder and its contents. 
In FactoryTalk View Studio, set up user access to these resources by 
right-clicking their folders or icons in the Explorer window, and then 
selecting Security. The following illustration shows which resources you can 
secure in this way: 
Modifying FactoryTalk Security settings 
Use the Security Settings dialog box to add the users or groups of users that 
are to have access to the resource, and then allow or deny permission to 
perform the actions that define levels of access. 
When setting up permissions for a network distributed application, you can 
associate users and groups of users with specific computers or groups of 
computers. 
This means you can determine not only who has access to system resources, 
but from which computers. 
Setting up security 
for FactoryTalk 
system resources 
C# PDF Library SDK to view, edit, convert, process PDF file for C#
and quick navigation link in PDF bookmark. C#.NET: Edit PDF Metadata. PDF SDK for .NET allows you to read, add, edit, update, and delete PDF file metadata, like
pdf hyperlink; add a link to a pdf in acrobat
C# PDF Page Rotate Library: rotate PDF page permanently in C#.net
C#.NET PDF Library - Rotate PDF Page in C#.NET. Empower C# Users to Change the Rotation Angle of PDF File Page Using C# Programming Language in .NET Application
pdf link; add hyperlink to pdf acrobat
Setting up security                  Chapter 5 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
115 
To open the Security Settings dialog box: 
In FactoryTalk View Studio, in the Explorer window, right-click the 
folder or icon for the resource you want to secure, and then select 
Security
For details about options in the Security Settings dialog box, click Help
Tip: The Security Settings dialog box in the illustration is for a 
network application. The Computers column does not 
exist in the dialog box for local station applications. 
To assign FactoryTalk Security permissions to users: 
1.  In the Permissions tab, select the User option for viewing permissions. 
You can also set up permissions by selecting the Action option. This 
means that you select an action and then specify which users or groups 
of user can perform the action. 
2.  Click Add, select the user or group of users to add, and then click OK
.NET PDF SDK - Description of All PDF Processing Control Feastures
Easy to change PDF original password; Options for setting PDF security PDF Hyperlink Edit. Support adding and inserting hyperlink (link) to PDF document; Allow to
adding hyperlinks to pdf documents; add a link to a pdf in preview
RasterEdge .NET Document Imaging Trial Package Download Link.
PDF Files; Split PDF Document; Remove Password from PDF; Change PDF Permission Settings. PDF to HTML; C#: Convert PDF to Jpeg; C# File: Compress PDF; C# File
check links in pdf; add hyperlink pdf document
Chapter 5                  Setting up security 
116 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
Tip: 
For a network application, you must associate the user or 
group of users with a computer, or group of computers, 
before you can click OK. 
The user or group of users you added should be selected (highlighted) 
in the Users list, in the Permissions tab. 
3.  To explicitly allow permission to perform an action, for the selected 
user or group of users, select the Allow check box beside the action. 
You can also select the Allow check box beside: 
All Actions, to select all the actions that apply to this resource. 
A category of actions, such as Common, to select all the actions in 
the category. 
4.  To explicitly deny permission to perform an action, for the selected 
user or group of users, select the Deny check box beside the action. 
5.  Repeat steps 2 to 4 for each user or group of users you are setting up 
with permissions. 
6.  Click OK
Any users that are not set up with permissions are removed from the 
list. 
For details about assigning permissions, see the FactoryTalk Security Help. 
Specifying which actions users can perform 
To secure access to a system resource, you specify which users or groups of 
users have permission to perform actions on the resource. 
In the previous illustration of the Security Settings dialog box, the Operators 
group has permission to perform the Common actions Read and List 
Children, at the FactoryTalk Network Directory. 
This means that members of the Operators group are allowed to run 
applications managed by the directory, in a FactoryTalk View SE Client. For 
more information about what the Common actions allow, see the example on 
Performing secured tasks in FactoryTalk View SE on page 120
About explicit and implicit permission 
Selecting the Deny check box for an action denies permission explicitly. If 
you do this, keep in mind that an explicit Deny takes precedence over an 
explicit Allow. This is important if the account you are setting up security for 
belongs to more than one group. 
Setting up security                  Chapter 5 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
117 
For example, if a user belongs to one group that is allowed to delete 
applications, and belongs to another group that is explicitly denied that 
permission, then the user will not be allowed to delete applications. 
Alternatively, you can clear the Allow check box for an action, to implicitly 
deny permission to perform the action. 
In this case, if a user belongs to one group that is allowed to delete 
application, and belongs to another group that is implicitly denied that 
permission, then the user will be allowed to delete applications. 
Organizing actions into groups 
To assign more than one action to a user or group of users in a single step, 
you can organize actions into groups. For example, you can group actions 
according to: 
Roles or jobs (operator, supervisor, maintenance engineer, and so on). 
The equipment user have access to (hoppers, mixers, ovens, and so on) 
When you add an action group, it is shown in the Explorer window under the 
Action Groups folder, and in the Security Settings dialog box under User 
Action Groups, as shown in the following illustration. 
You allow or deny permission to perform an action group, just as you allow 
or deny permission to perform a single action. For information about 
assigning permissions, see Specifying which actions users can perform on 
page 116
To add an action group: 
In FactoryTalk View Studio, in the Explorer window, right-click the 
Action Groups folder, and then click New Action Group. 
For details about options in the New Action Group dialog box, click 
Help
Chapter 5                  Setting up security 
118 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
Inheritance means that any security settings you define at the FactoryTalk 
Directory, extend to all system resources that the directory manages. These 
resources include the application and areas within the application, plus the 
System folder and its subfolders. 
Inheritance allows you to define basic levels of access for a broad set of 
users, across a FactoryTalk system. You can then refine security settings for 
selected users as necessary, by overriding permissions inherited by the 
lower-level resources. 
In a FactoryTalk View SE application, an HMI server always inherits the 
permissions assigned to the area, in which it resides. You cannot set up 
access to an HMI server separately. 
However, the chain of inheritance that starts at the FactoryTalk Directory 
does not extend to a user’s ability to access certain HMI project components 
at run time. 
To restrict access to specific FactoryTalk View commands and macros, 
graphic displays, OLE objects, or HMI tags, you must secure these 
components separately, within the FactoryTalk View SE application. 
For details, see Setting up run-time security for HMI project components on 
page 101
Tip: To secure individual HMI tags at run time, assign security 
codes to them in FactoryTalk View. To control access to 
tags in general, including HMI and data server tags, 
allow or deny permission to perform the Tag action Write 
Value. 
For more information about how inheritance works, see FactoryTalk Security 
Help. 
Breaking the chain of inheritance 
You can override inherited permissions by breaking the chain of inheritance. 
To break the chain of inheritance: 
In the Security Settings dialog box for the resource, select the check 
box, Do not inherit permissions. 
Understanding 
inherited 
permissions 
Setting up security                  Chapter 5 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
119 
You are prompted to choose one of these options, instead of inheriting 
permissions: 
Copy the inherited permissions and make them explicit for the 
resource. 
Remove all inherited permission from the resource. 
Tip: Breaking the chain of inheritance applies to the resource, 
not to the user or group of users selected in the Security 
Settings dialog box. 
If you choose to copy inherited permissions, the change 
is applied to all listed users that have any inherited 
permissions. If you choose to remove all inherited 
permissions, all listed users that have only inherited 
permissions are removed from the Security Settings 
dialog box. 
Using explicit permissions to override inheritance 
You can also override inheritance by allowing or denying explicit permission 
to perform actions on selected resources. 
For example, in the table on page 1-38, the Supervisors group has permission 
to perform all Common actions, except for Configure Security, at the 
FactoryTalk Network Directory. 
In the Security Settings dialog box for the application, inherited permissions 
set up at the FactoryTalk Directory for the Supervisors group show as gray 
check marks, as in the following illustration. 
To extend or further restrict this group’s access at the application level, you 
might make the following explicit changes, to override the inherited 
permissions: 
Select the Allow check box beside the Configure Security action. 
Explicitly allowing the Configure Security action on the application 
means that Supervisors can set up security for the application, add 
Chapter 5                  Setting up security 
120 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
Runtime Security accounts and assign security codes to those users, 
and secure HMI project components. 
Select the Deny check box beside the Delete action. 
Explicitly denying the Delete action on the application means that 
Supervisors are prevented from deleting applications. 
The changes are reflected in the Effective Permissions tab, as shown in the 
following illustration. 
When setting up permissions, or overriding inherited permissions, keep these 
rules of precedence in mind: 
Explicit Deny takes precedence over explicit Allow. 
Explicit Allow takes precedence over implicit Deny. 
Tip: When you use explicit permissions (Allow or Deny) to 
override inheritance on a particular resource, these 
permissions become the ones that are inherited by 
lower-level resources. 
To perform certain tasks in FactoryTalk View SE, users must have the 
security permissions needed for access to the FactoryTalk Directory, 
application, or area where the task is to be authorized. 
For information about: 
How to assign permissions to users, see Specifying which actions users 
can perform on page 116
How inherited permissions work, see Understanding inherited 
permissions on page 118
Some of the tasks FactoryTalk View SE users can perform require additional 
permissions. For information about permissions related to: 
Switching the Active and Secondary servers in a redundant pair, see 
What happens if both servers become active on page 366
Enabling or disabling, suppressing or unsuppressing, or acknowledging 
FactoryTalk alarms, see Setting up FactoryTalk alarms on page 261
Performing secured 
tasks in FactoryTalk 
View SE 
Documents you may be interested