extract data from pdf c# : Add hyperlink in pdf SDK software API .net winforms windows sharepoint viewse-um006_-en-e15-part703

Working with network station applications                  Chapter 7 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
151 
About FactoryTalk systems 
FactoryTalk View SE and other Rockwell Automation software products use 
a set of common FactoryTalk services to support certain functions, such as 
diagnostic messages and access to real-time data. 
These services, including FactoryTalk Directory, are installed with the 
FactoryTalk Services Platform when you install FactoryTalk View SE. For 
an overview of FactoryTalk services, see FactoryTalk Services Platform on 
page 26
An automation and control system that uses FactoryTalk services, and 
integrates FactoryTalk products and components, is known as a FactoryTalk 
system. 
Finding more information about FactoryTalk 
services 
This manual contains information about developing FactoryTalk View SE 
applications, including information about how FactoryTalk View uses 
FactoryTalk services. 
For additional, detailed information about FactoryTalk systems, services, 
concepts, and components, see the FactoryTalk Help. 
To open the FactoryTalk Help: 
Select Start > All Programs > Rockwell Software > FactoryTalk Tools 
FactoryTalk Help
You can also open the FactoryTalk Help by clicking Help in dialog boxes 
used to set up FactoryTalk components and services. 
This section presents some of the common terms and concepts used to 
describe FactoryTalk View SE network station applications. 
FactoryTalk Network Directory 
The FactoryTalk Directory centralizes access to application resources 
components, such as graphic displays and tags, for all FactoryTalk products 
participating in a control system. 
For example, to access graphic displays in a network distributed application, 
HMI clients use FactoryTalk Directory to find out which computers on the 
network are hosting the HMI servers that provide the displays. 
Key network station 
application 
concepts 
Add hyperlink in pdf - insert, remove PDF links in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Free C# example code is offered for users to edit PDF document hyperlink (url), like inserting and deleting
add hyperlink to pdf; chrome pdf from link
Add hyperlink in pdf - VB.NET PDF url edit library: insert, remove PDF links in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Help to Insert a Hyperlink to Specified PDF Document Page
clickable pdf links; add hyperlink pdf
Chapter 7                  Working with network station applications 
152 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
FactoryTalk Network Directory (also called the Network Directory) manages 
FactoryTalk View SE network distributed and network station applications. 
All of the computers participating in a particular network distributed 
application must share a common Network Directory, located on a network 
server. 
For more information about FactoryTalk Network Directory, see Setting up 
the FactoryTalk Directory on page 77
Note: 
Do not run FactoryTalk Directory, or any other application 
software, on the same computer as a Windows domain 
controller. 
FactoryTalk Security 
FactoryTalk View SE applications can use FactoryTalk Security services to 
authenticate and authorize application users. 
During FactoryTalk View SE installation, Windows users with 
administrative privileges on the computer are set up with full, initial access to 
FactoryTalk View SE applications managed by a FactoryTalk Local or 
Network Directory on the same computer. 
In FactoryTalk View Studio, you can create FactoryTalk user and group 
accounts, and then determine which accounts have access to resources such 
as the Local Directory, or the application. 
For an overview of FactoryTalk Security services, see Setting up security on 
page 85. For details, see the FactoryTalk Security Help. 
About FactoryTalk Security permissions 
If FactoryTalk Security services are used to secure parts of an application, to 
perform certain tasks, users must have the necessary security permissions. 
For example, to create or modify the properties of an application, you must at 
least be allowed the Common actions Read, List Children, Write, and Create 
Children, at the FactoryTalk Directory that manages the application. 
If you receive a FactoryTalk Security message while trying to perform such a 
task, contact your system administrator about permissions you might require. 
For an overview of FactoryTalk Security services, see Setting up security on 
page 85. For details, see FactoryTalk Security Help. 
VB.NET Create PDF from Word Library to convert docx, doc to PDF in
Change Word hyperlink to PDF hyperlink and bookmark. VB.NET Demo Code for Converting Word to PDF. Add necessary references: RasterEdge.Imaging.Basic.dll.
add links to pdf in preview; pdf link to attached file
VB.NET Create PDF from Excel Library to convert xlsx, xls to PDF
Change Excel hyperlink to PDF hyperlink and bookmark. VB.NET Demo Code for Converting Excel to PDF. Add necessary references: RasterEdge.Imaging.Basic.dll.
add hyperlink to pdf online; add url to pdf
Working with network station applications                  Chapter 7 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
153 
HMI servers 
HMI servers are software programs that supply information to clients as they 
request it. 
An HMI server stores HMI project components such as graphic displays, and 
serves these components to clients. An HMI server also manages a database 
of tags, detects HMI tag alarms, and logs historical data. 
In FactoryTalk View Studio, first you create a network station application, 
and then you add one (and only one) HMI server to the application. 
Note: A FactoryTalk View SE network station application must have 
one and only one HMI server. You can add the HMI server in 
the root area of the application (the icon and application name 
in the Explorer window) or within the areas you have created. 
For information about adding an HMI server to an application, see 
Adding an HMI server on page 156
HMI projects 
HMI projects contain graphic displays, data log models, HMI tags, HMI tag 
alarms, and other services. Network station applications can contain only one 
HMI project. 
HMI clients 
HMI clients are software programs that obtain information from, or write 
information to HMI servers or data servers. FactoryTalk View Studio, the 
FactoryTalk View SE Administration Console, and the FactoryTalk View SE 
Client are all HMI clients. 
Areas 
All FactoryTalk View applications have one system-defined area called the 
application root area, which has the same name as the application. The 
application root area can contain one HMI server and one or more OPC data 
servers. It is a system best practice to only have one RSLinx Enterprise data 
server in the root area or individual area. 
How to C#: Basic SDK Concept of XDoc.PDF for .NET
You may add PDF document protection functionality into your C# program. Hyperlink Edit. XDoc.PDF for .NET allows C# developers to edit hyperlink of PDF document
add page number to pdf hyperlink; add email link to pdf
VB.NET PDF: Basic SDK Concept of XDoc.PDF
You may add PDF document protection functionality into your VB.NET program. Hyperlink Edit. XDoc.PDF for .NET allows VB.NET developers to edit hyperlink of PDF
add links in pdf; pdf hyperlink
Chapter 7                  Working with network station applications 
154 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
Note: 
A FactoryTalk View SE network station application must have 
one and only one HMI server. You can add the HMI server in 
the root area of the application (the icon and application name 
in the Explorer window) or within the areas you have created. 
About the home area 
In an application, the area that contains a given application component, such 
as a graphic display, is called the home area. 
When you refer to an application component without specifying the area, 
FactoryTalk View SE uses the home area to locate the component. 
For example, if an object in a graphic display refers to a tag without 
specifying an area, FactoryTalk View assumes that the tag and the display 
are in the same home area. 
If the tag cannot be found in an HMI server or a data server in the display’s 
home area, an error is logged when the display is run. 
Relative references 
You can have both referencing types in a network station application when 
using Areas. In a network station application, you use relative references to 
refer to application components, such as graphic displays and tags, when 
building FactoryTalk View commands or connecting graphic objects to 
process data. 
Relative references point at a component relative to the current application. 
For example, a relative reference to a display named Detail is simply the 
display’s name: Detail. To set up a button in a graphic display to open the 
Detail display at run time, use 
Display Detail
as the button’s press action.
System availability 
To minimize data loss and down time, and to help ensure that critical parts of 
a control system remain available to connected clients, FactoryTalk View SE 
provides features such as server status monitoring and support for online 
changes. 
For information about these and other availability features, see Setting up 
FactoryTalk system availability on page 349
C# Create PDF from Word Library to convert docx, doc to PDF in C#.
Change Word hyperlink to PDF hyperlink and bookmark. C#.NET Sample Code: Convert Word to PDF in C#.NET Project. Add necessary references:
adding links to pdf in preview; add links to pdf acrobat
.NET PDF Document Viewing, Annotation, Conversion & Processing
Extract hyperlink inside PDF. PDF Write. Insert text, text box into PDF. Edit, delete text from PDF. Insert images into PDF. Edit, remove images from PDF. Add,
adding an email link to a pdf; add hyperlink pdf file
Working with network station applications                  Chapter 7 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
155 
Tip: 
You can set up HMI redundancy  in  network distributed 
applications only. You can set up Data Server and FTAE 
Redundancy in network distributed applications and 
network station applications, but not in local station 
applications. 
Language switching 
To make user-defined text strings in an application available at run time in up 
to 40 different languages, set up language switching for the application. 
For more information, see Setting up language switching on page 323
To create a network station application, in FactoryTalk View Studio, first 
you create the application, and then you add elements such as areas, HMI 
server, data servers, and FactoryTalk Tag Alarm and Event Servers. 
To create a network station application: 
1.  Select Start > All Programs > Rockwell Software > FactoryTalk 
View > FactoryTalk View Studio
2.  In the Application Type Selection dialog box, select View Site Edition 
(Network Station), and then click Continue
3.  In the New/Open Site Edition (Network Station) Application dialog 
box, click the New tab. 
4.  Type a name and description for the application, select an application 
language, and then click Create
Creating network 
station applications 
VB.NET Create PDF from PowerPoint Library to convert pptx, ppt to
Export PowerPoint hyperlink to PDF. VB.NET Demo Code for Converting PowerPoint to PDF. Add necessary references: RasterEdge.Imaging.Basic.dll.
check links in pdf; adding hyperlinks to pdf
C# Create PDF from PowerPoint Library to convert pptx, ppt to PDF
Export PowerPoint hyperlink to PDF in .NET console application. C#.NET Demo Code: Convert PowerPoint to PDF in C#.NET Application. Add necessary references:
add hyperlink to pdf in preview; adding a link to a pdf
Chapter 7                  Working with network station applications 
156 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
In the Explorer window, the application icon and name are shown 
beneath the Network Directory icon. 
A network station application can consist of one or more areas, one HMI 
server, and, if necessary, multiple data servers and FactoryTalk Tag Alarm 
and Event Servers. You add these elements to the application, after you 
create it. 
Adding and deleting areas 
You can add and delete areas in an application. You cannot copy areas. 
To add an area: 
1.  In FactoryTalk View Studio, in the Explorer window, right-click the 
application root or right-click an area name, and then click New Area. 
2.  In the New Area dialog box, type a name for the area, and an optional 
description, and then click OK
To delete an area: 
Right-click the area you want to delete, and then click Delete
When you delete an area, HMI servers and data servers located in the area 
are not deleted from disk. 
Adding an HMI server 
After you create a network station application, you must add one HMI server, 
either to the application’s root area, or to the area you have added.
A network station application can contain one and only one HMI server. 
Adding areas and 
servers to a network 
station application 
Working with network station applications                  Chapter 7 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
157 
To add an HMI server: 
1.  In FactoryTalk View Studio, in the Explorer window, right-click the 
application root or right-click an area name, select Add New Server > 
HMI Server
2.  In the Add HMI Server wizard, in the Select Operations window, click 
one of the following options: 
Create a new HMI server. When you create an HMI server, the 
server
’s HMI project is created automatically.
Copy an HMI server that already exists. After you have copied an 
HMI server, changes made to the original do not affect the copy, or 
vice versa. 
Import a project from RSView32, FactoryTalk View SE, or 
FactoryTalk View Machine Edition, as the basis for the new HMI 
server. After you have copied a project, changes made to the 
original do not affect the copy, or vice versa. 
Attach to an existing HMI server without making a copy of the 
HMI server. 
Note: You cannot attach to an existing HMI server that is being used 
in another application. 
3.  Click Next, and then follow the instructions in the wizard to finish 
adding the server. 
Tip: 
The Add Controller Instruction Faceplates dialog box 
opens, if it’
s set to show when you create a new HMI 
server. If you do not want to add faceplates, click Cancel 
to close the dialog box, without affecting server creation. 
For more information about adding faceplates, see 
Adding controller instruction faceplates to an application 
on page 420
After adding the HMI server, you can set up its properties. For details, see 
Setting up HMI server properties on page 159
Chapter 7                  Working with network station applications 
158 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
Then, you can use editors in the Explorer window to create HMI project 
components, such as graphic displays, HMI tags, and data log models. 
Adding a data server 
The application root area can contain one HMI server and one or more OPC 
Data servers.  It is a system best practice to only have one RSLinx 
Enterprise data server in the root area or individual area. 
To add an RSLinx Enterprise data server: 
1.  In FactoryTalk View Studio, in the Explorer window, right-click the 
application root or right-click the area name, select Add New Server > 
Rockwell Automation Device Server (RSLinx Enterprise)
2.  Set up server properties, such as the name and location of the server, 
whether to provide redundancy using a secondary server, and whether 
the server will support alarms and events. 
For details, see the RSLinx Enterprise product documentation. 
To add an OPC data server: 
1.  In FactoryTalk View Studio, in the Explorer window, right-click the 
application root, or right-click the area name, select Add New Server 
> OPC Data Server
2.  Set up properties, such as the name and location of the server, and 
whether to provide redundancy using a secondary server. 
For details, see the RSLinx Classic (or other OPC data server) product 
documentation. 
For additional information about setting up RSLinx and OPC data servers, 
see Setting up communications on page 177. 
Adding a Tag Alarm and Event Server 
Optionally, you can add FactoryTalk Tag Alarm and Event Servers to an 
application. 
Tag Alarm and Event Servers use FactoryTalk Alarms and Events services to 
monitor and control alarms for tags in programmable controllers (PLC-5 or 
SLC 500) and other devices, that do not have built-in alarm detection. 
For more information about Tag Alarm and Event Servers, see Setting up 
FactoryTalk alarms on page 261
Working with network station applications                  Chapter 7 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
159 
Providing HMI server names 
The FactoryTalk Directory stores HMI server names and does not delete 
them, even if you remove an HMI server from all the applications in which it 
is used, and then delete the HMI server’s project files.
This means that every HMI server must have a unique name: 
You cannot re-
use an HMI server’s name, even after you delete the 
HMI server from an application. 
If multiple users share the same FactoryTalk Directory, the names of 
all HMI servers created by all users must be unique. 
Similarly, if multiple applications share the same FactoryTalk 
Directory, the name of each HMI server in each application must be 
unique. 
Monitoring disk space on HMI servers 
After deploying a FactoryTalk View SE network distributed application, 
monitor disk space on computers running HMI servers to make sure that it 
does not fall below 500 MB. 
To monitor disk space: 
1. 
In the HMI server’
s Events editor, create an event that uses the 
free_bytes function to return the number of free bytes available on the 
HMI server’s hard disk.
2.  Create an HMI analog or digital alarm tag. 
To indicate when disk space drops below preset levels above 500 MB, 
set up alarm conditions for an HMI analog tag. To indicate only when 
disk space drops below 500 MB, set up alarm conditions for an HMI 
digital tag. 
For information about setting up events, see Adding logic and control on 
page 631
After adding an HMI server to a network station application, use the 
Properties dialog box to: 
Select the components that will run when the HMI server starts up. 
Specify a macro to run when the HMI server shuts down. 
Setting up HMI 
server properties 
Chapter 7                  Working with network station applications 
160 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
To open the HMI Server Properties dialog box: 
In FactoryTalk View Studio or the SE Administration Console, in the 
Explorer window, right-click the HMI server icon, and then select 
Properties
For details about options in the HMI Server Properties dialog box, click 
Help
Starting and stopping HMI server components 
manually 
For the HMI server in a network station application, you can start and stop 
the server’s components manually.
To start HMI server components manually: 
1.  In FactoryTalk View Studio or the SE Administration Console, open 
the network station application. 
2.  In the Explorer window, right-click the HMI server, and then select 
Properties
3.  In the Components tab, click Run Startup Components
The startup components selected for the HMI server should start 
running. 
To stop HMI server components manually: 
1.  In FactoryTalk View Studio, open the network station application. 
2.  In the Explorer window, right-click the HMI server, and then select 
Properties
3.  In the Components tab, click Stop All Running Components
Documents you may be interested
Documents you may be interested