Working with network station applications                  Chapter 7 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
161 
All the components running on the computer will stop running, 
including alarms, data log models, derived tag components, and event 
components. If a shutdown macro is specified in the Components tab, 
the specified macro also will run. 
In FactoryTalk View Studio, in the Server Status dialog box, you can view 
the operational status of an HMI server to determine whether the server is 
ready to provide service, and to troubleshoot problems. 
For example, an HMI server in the Active state is fully loaded and ready to 
provide service to connected clients. A client can be any of FactoryTalk 
View Studio, a FactoryTalk View SE Client, or the FactoryTalk View SE 
Administration Console. 
For more information about server states, see Monitoring the status of 
application servers on page 351
To open the Server Status dialog box: 
In FactoryTalk View Studio, in the Explorer window, right-click the HMI 
server’s icon, and then select 
Server Status
For details about options in the Server Status dialog box, click Help
You can delete an HMI server from an application without deleting the HMI 
project files, and then add the HMI server to the application later. 
You can also add the HMI server temporarily, while you copy components to 
other HMI servers in the application. 
To delete an HMI server: 
1.  Disconnect all clients from the HMI server. (A client is any of 
FactoryTalk View Studio, FactoryTalk View SE Administration 
Console, or the FactoryTalk View SE Client.) 
2.  Start FactoryTalk View Studio, and then open the application that 
contains the HMI server you want to delete. 
3.  Right-click the HMI server, and then select Delete
This does not delete the HMI server’s project files.
Monitoring the 
status of an HMI 
server 
Deleting HMI 
servers 
Add links in pdf - insert, remove PDF links in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Free C# example code is offered for users to edit PDF document hyperlink (url), like inserting and deleting
adding hyperlinks to a pdf; add link to pdf file
Add links in pdf - VB.NET PDF url edit library: insert, remove PDF links in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Help to Insert a Hyperlink to Specified PDF Document Page
adding hyperlinks to pdf files; add links to pdf in acrobat
Chapter 7                  Working with network station applications 
162 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
Deleting HMI server project files 
After you delete an HMI server from an application, if you want to delete the 
project files, you have to delete them separately. 
To delete an HMI server’s project files:
1.  Disconnect all clients from the HMI server. (A client is any of 
FactoryTalk View Studio, the FactoryTalk View SE Administration 
Console, or the FactoryTalk View SE Client.) 
2.  In Windows Explorer, browse to the HMI Projects folder on the 
computer hosting the HMI server C:\Users\Public\Public 
Documents\RSView Enterprise\SE\HMI Projects
3.  In the HMI Projects folder, delete the subfolder that has the same name 
as the HMI server you deleted from the application. 
For example, if you deleted an HMI server named Water, then you will 
delete an HMI project folder also named Water. 
Use the Application Manager tool to rename or delete a network station 
application. 
Tip: 
You cannot rename or delete a network station 
application that is in use. Ensure that all users 
disconnect from the application first. 
To run the Application Manager: 
Select Start > All Programs > Rockwell Software > FactoryTalk View > 
Tools > Application Manager
For details about options in the Application Manager, click Help
To rename a network station application: 
1.  In the Application Manager, select Site Edition (Network Station)
and then click Next
2.  Select Rename application, and then click Next
3.  Follow the instructions in the Application Manager to complete the 
rename operation. 
To delete a network station application: 
1.  In the Application Manager, select Site Edition (Network Station)
and then click Next
Renaming and 
deleting network 
station applications 
C# PDF Convert to HTML SDK: Convert PDF to html files in C#.net
HTML converter toolkit SDK, preserves all the original anchors, links, bookmarks and to Use C#.NET Demo Code to Convert PDF Document to Add necessary references
add links to pdf online; pdf link open in new window
.NET PDF Document Viewing, Annotation, Conversion & Processing
PDF Write. Insert text, text box into PDF. Edit, delete text from PDF. Insert images into PDF. Edit, remove images from PDF. Add, edit, delete links. Form Process
adding a link to a pdf in preview; pdf hyperlinks
Working with network station applications                  Chapter 7 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
163 
2.  Select Delete application, and then click Next. 
3.  Follow the instructions in the Application Manager to complete the 
delete operation. 
When you delete a network station application, the HMI servers and data 
servers set up in it are not deleted automatically. For details about: 
Deleting the HMI server files, see Deleting HMI server project files on 
page 145
Removing a data server and deleting its cache files, see Deleting an 
OPC data server on page 188
Backing up and restoring network station 
applications 
You also use the Application Manager tool to copy, back up, and restore a 
network station application. For details, see information about deploying 
local applications, in the FactoryTalk View Site Edition Installation Guide
You can browse properties of any Network Station application from any 
computer in FactoryTalk Admin Console. And you cannot distinguish 
between Network Distributed and Network Station applications in 
FactoryTalk Admin Console. 
To determine the host computer for the application: 
1.  Select Start > All Programs > Rockwell Software > FactoryTalk 
View > FactoryTalk View Studio
2.  In the Application Type Selection dialog box, select View Site Edition 
(Network Station), and then click Continue
Determing where 
the application is 
located 
VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.
Turn PDF images to HTML images in VB.NET. Embed PDF hyperlinks to HTML links in VB.NET. Convert PDF to HTML in VB.NET Demo Code. Add necessary references:
pdf hyperlink; add hyperlinks to pdf online
C# PDF Convert to Word SDK: Convert PDF to Word library in C#.net
the original text style (including font, size, color, links and boldness). C#.NET DLLs and Demo Code: Convert PDF to Word Document in C# Add necessary references
check links in pdf; clickable links in pdf
Chapter 7                  Working with network station applications 
164 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
3.  In the New/Open Site Edition (Network Station) Application dialog 
box, click the Existing tab. 
The value in the HMI Server Computer column reflects the status of the HMI 
server added to that application. Status values include: 
Localhost - the HMI server is located on the current computer. 
computer name - the HMI server is located on the computer named (for 
example, NVCARBCBAS113). 
<Unassigned> - no HMI server has been added to the application. 
To rehost an HMI server: 
The applications restored from a .bak file need to be rehosted. For more 
information about restoring a .bak file, refer to the FactoryTalk Help. 
1.  Use the HMI Server Backup and Restore utility to restore the HMI 
server. For more information, please refer to the HMI Server Backup 
and Restore utility help. 
2.  Select Start > All Programs > Rockwell Software > FactoryTalk 
View > FactoryTalk View Studio
3.  In the Application Type Selection dialog box, select View Site Edition 
(Network Station), and then click Continue
4.  In the New/Open Site Edition (Network Station) Application dialog 
box, click the Existing tab. 
5.  Select the application containing the HMI server that you want to 
rehost, and click Open
6.  Right-click the HMI server, and select Properties. 
How to C#: Basic SDK Concept of XDoc.PDF for .NET
You may add PDF document protection functionality into your C# program. to edit hyperlink of PDF document, including editing PDF url links and quick
add a link to a pdf in acrobat; add email link to pdf
C# Create PDF Library SDK to convert PDF from other file formats
PDF with a blank page, bookmarks, links, signatures, etc. PDF document in C#.NET using this PDF document creating toolkit, if you need to add some text
convert excel to pdf with hyperlinks; add url link to pdf
Working with network station applications                  Chapter 7 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
165 
7.  In the Computer hosting the server field, type another computer 
name or click the browse button to search for and select one. 
VB.NET PDF: Basic SDK Concept of XDoc.PDF
You may add PDF document protection functionality into your VB.NET program. to edit hyperlink of PDF document, including editing PDF url links and quick
adding an email link to a pdf; pdf link to specific page
C# Image: Tutorial for Document Management Using C#.NET Imaging
more detailed C# tutorials on each part by following the links respectively are dedicated to provide powerful & profession imaging controls, PDF document, image
add hyperlink in pdf; add link to pdf file
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
167 
Chapter 8 
Working with local station 
applications 
This chapter describes: 
What a FactoryTalk View Site Edition local station application is. 
Key local station application concepts. 
How to create a local station application. 
How to add servers to a local station application. 
Setting up HMI server properties. 
Monitoring the status of an HMI server. 
Renaming, deleting, copying, and backing up local station applications. 
In FactoryTalk View Studio, you can create FactoryTalk View Site Edition 
network and local station applications. The following illustration shows what 
a FactoryTalk View SE local station application looks like in the 
FactoryTalk View Studio Explorer window: 
Network distributed applications are described in Working with network 
distributed applications on page 125. Network station applications are 
described in Chapter 7, Working with network station applications. 
About local station 
applications 
Chapter 8                  Working with local station applications 
168 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
Parts of a local station application 
A typical FactoryTalk View SE local station application consists of: 
The application root area. You cannot add areas to a local station 
application. 
An HMI server that provides FactoryTalk View components and 
services to application clients. 
A local station application can contain only one HMI server. The HMI 
server is created automatically when the application is created, and has 
the same name as the application. 
HMI project components such as graphic displays, HMI tags, and data 
log models. 
One or more data servers, providing clients with access to information 
in programmable controllers, devices, and other data servers that 
comply with the OPC-DA 2.05a specification, with or without the use 
of HMI tags. 
Local station applications support a single RSLinx Enterprise data 
server, which must run on the same computer as the application. Only 
OPC data servers (including RSLinx Classic) can be located on other 
computers. 
RSLinx Enterprise servers can be set up to subscribe to device-based 
alarms detected in Logix5000 controllers. For more information, see 
Setting up FactoryTalk alarms on page 261
Tip: 
Every vendor’
s OPC data server is different. Some 
contain their own tag databases, like the tag database in 
an HMI server, while others reference the tag databases 
or addresses that exist in controllers, as is the case with 
RSLinx and Logix5000. 
A list of users, plus the security codes that allow or deny these users 
permission to access secured HMI project components at run time. 
Optionally, a FactoryTalk Tag Alarm and Event Server, to provide 
alarm monitoring and control for tags in devices that do not have 
built-in alarm detection. For more information, see Setting up 
FactoryTalk alarms on page 261
The software programs behind a local station application
the FactoryTalk 
Local Directory, the HMI server, the HMI client, and the RSLinx Enterprise 
data server
must be located on the same computer. Only OPC data servers 
can reside on remote computers. 
The location of the FactoryTalk Local Directory that manages a local station 
application is set up automatically, when you install FactoryTalk View Site 
Edition. 
Working with local station applications                  Chapter 8 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
169 
About FactoryTalk systems 
FactoryTalk View SE and other Rockwell Automation software products use 
a set of common FactoryTalk services to support certain functions, such as 
diagnostic messages and access to real-time data. 
These services, including FactoryTalk Directory, are installed with the 
FactoryTalk Services Platform when you install FactoryTalk View SE. For 
an overview of FactoryTalk services, see FactoryTalk Services Platform on 
page 26
An automation and control system that uses FactoryTalk services, and 
integrates FactoryTalk products and components, is known as a FactoryTalk 
system. 
Finding more information about FactoryTalk 
services 
This manual contains information about developing FactoryTalk View SE 
applications, including information about how FactoryTalk View uses 
FactoryTalk services. 
For additional, detailed information about FactoryTalk systems, services, 
concepts, and components, see the FactoryTalk Help. 
To open the FactoryTalk Help: 
Select Start > All Programs > Rockwell Software > FactoryTalk Tools 
FactoryTalk Help
You can also open the FactoryTalk Help by clicking Help in dialog boxes 
used to set up FactoryTalk components and services. 
This section presents some of the common terms and concepts used to 
describe FactoryTalk View SE local station applications. 
FactoryTalk Local Directory 
The FactoryTalk Directory centralizes access to application resources and 
components, such as graphic displays and tags, for all FactoryTalk products 
participating in a control system. 
For example, to access tag values in a data server, HMI clients use 
FactoryTalk Directory to find out which computer is hosting the data server. 
Key local station 
application 
concepts 
Chapter 8                  Working with local station applications 
170 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
FactoryTalk Local Directory (also called the Local Directory) manages 
FactoryTalk View SE local station applications. The Local Directory must 
reside on the same computer as the local station application. 
For more information, see Setting up the FactoryTalk Directory on page 77
Note: Do not run FactoryTalk Directory, or any other application 
software, on the same computer as a Windows domain 
controller. 
FactoryTalk Security 
FactoryTalk View SE applications can use FactoryTalk Security services to 
authenticate and authorize application users. 
During FactoryTalk View SE installation, Windows users with 
administrative privileges on the computer are set up with full, initial access to 
FactoryTalk View SE applications managed by a FactoryTalk Local or 
Network Directory on the same computer. 
In FactoryTalk View Studio, you can create FactoryTalk user and group 
accounts, and then determine which accounts have access to resources such 
as the Local Directory, or the application. 
For an overview of FactoryTalk Security services, see Setting up security on 
page 85. For details, see the FactoryTalk Security Help. 
About FactoryTalk Security permissions 
If FactoryTalk Security services are used to secure parts of an application, to 
perform certain tasks, users must have the necessary security permissions. 
For example, to create or modify the properties of an application, you must at 
least be allowed the Common actions Read, List Children, Write, and Create 
Children, at the FactoryTalk Directory that manages the application. 
If you receive a FactoryTalk Security message while trying to perform such a 
task, contact your system administrator about permissions you might require. 
For an overview of FactoryTalk Security services, see Setting up security on 
page 85. For details, see FactoryTalk Security Help. 
HMI servers 
HMI servers are software programs that supply information to clients as they 
request it. 
Documents you may be interested
Documents you may be interested