c# pdf manipulation : Add url to pdf control SDK system azure wpf .net console viewse-um006_-en-e44-part735

Creating graphic displays                  Chapter 16 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
441 
The [cache ] parameter loads a graphic display into the cache without 
displaying it. The parameter has two options: 
/Z loads the graphic display into the cache without opening it. 
When the display is called up subsequently, it opens quickly. 
/ZA loads the display into the cache and continually updates the 
values in the display, even when the display is not visible. 
For details about the Display command, see the FactoryTalk View Site 
Edition Help. 
Removing displays from the cache 
To remove all graphic displays from the display cache, run the FlushCache 
command, or close the FactoryTalk View SE Client. 
To remove a specific graphic display from the cache, run FlushCache <file>, 
where <file> is the name of the display you want to remove. For details, see 
the FactoryTalk View Site Edition Help. 
If a graphic display uses the Always Updating option with the Cache After 
Displaying option, the disp
lay’s shutdown command is run when the 
FlushCache command is run, or when you close the application. 
Changing the default display settings 
When you begin using the Graphics editor to create graphic displays for an 
application, the values already specified in the Display Settings dialog box 
are used as default values. 
For example, the Display Type property is set to Replace, the Title Bar 
property is selected (meaning the display will have a title bar), and the 
Background Color property is set to white. 
All the new displays you create will have these initial default settings. 
To change the default settings for new graphic displays: 
1.  Create a new display, and change its display settings to the desired 
default values. 
Tip: When you make certain changes, the Set as Default 
button changes to Apply. This lets you apply the changes 
to the current display without closing the Display Settings 
dialog box. 
It does not affect the default display settings. 
2.  Click OK to save the changes and to close the Display Settings dialog 
box. 
Add url to pdf - insert, remove PDF links in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Free C# example code is offered for users to edit PDF document hyperlink (url), like inserting and deleting
accessible links in pdf; pdf hyperlinks
Add url to pdf - VB.NET PDF url edit library: insert, remove PDF links in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Help to Insert a Hyperlink to Specified PDF Document Page
add link to pdf acrobat; add hyperlink pdf file
Chapter 16                  Creating graphic displays 
442 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
3.  Open the Display Settings dialog box again, and then click Set as 
Default at the bottom of the dialog box. 
The values selected for the previous display become default settings for 
new displays. 
At run time, graphic displays can be docked to an edge of the FactoryTalk 
View SE Client window, so that operators can gain access to the displays at 
all times. 
For example, you might consider docking: 
Navigational menus that provide operators with ways to move among 
displays in an application. 
Headers or banners that provide specific information to the operator, 
such as the current user’s name and area, or information about alarms.
Control panels, that contain standard buttons for special purposes, such 
as changing users, closing open windows, or sending information to a 
maintenance team. 
Display command parameters for docking displays 
To dock graphic displays, run the Display command with any of the 
following parameters: 
To dock a display in this position 
Use this parameter 
Top edge of the client window 
/DT 
Bottom edge of the client window 
/DB 
Left edge of the client window 
/DL 
Right edge of the client window 
/DR 
To let an operator dock a graphic display, provide a button object in another 
display, that uses the Display command with one of the docking parameters 
as its press action. 
In the FactoryTalk View SE Client Wizard, you can also specify a docking 
parameter for the initial display that runs when the client starts up. 
Docking displays to 
the FactoryTalk 
View SE Client 
window 
C#: How to Open a File from a URL (HTTP, FTP) in HTML5 Viewer
License and Price. File Formats. PDF. Word. Excel. PowerPoint. Tiff. DNN (Dotnetnuke). Quick to Start. Add a Viewer Control on Open a File from a URL (HTTP, FTP).
add hyperlinks to pdf online; add url link to pdf
C#: How to Add HTML5 Document Viewer Control to Your Web Page
addTab(_tabRedact); //add Tab "Sample new UserCommand("pdf"); _userCmdDemoPdf.addCSS( new customStyle({ background: "url('RasterEdge_Resource_Files/images
pdf email link; pdf link
Creating graphic displays                  Chapter 16 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
443 
Tip: 
The Display command parameters /B, /Min., /Max, /X, 
and /Y are ignored when specified with 
a docking parameter. For more information, see the 
FactoryTalk View Site Edition Help. 
Example: Using the Display command to dock a display after the 
FactoryTalk View SE Client starts up 
To dock a display named Menu to the top edge of the SE Client window after 
the client starts up, create a button in the initial display that uses this 
command as its press action: 
Display Menu /DT
When the operator presses the button, the display will attach to the top of the 
window. 
About the appearance and behavior of docked 
displays 
When you open a graphic display using one of the docking parameters, 
certain display settings are ignored. For example, regardless of what is 
specified in the Display Settings dialog box, a docked display: 
Has no borders or scroll bars. 
Has no title bar (and therefore no minimize, maximize, or close 
buttons). 
Cannot be undocked or moved. 
Cannot be resized, independent of the FactoryTalk View SE Client 
window. 
Tip: 
Changing the width of the client window changes the 
width of displays docked at the top or bottom of the 
window. Changing the height of the window changes the 
height of displays docked at the left or right. 
If a graphic display is set up to pan or scale, to allow multiple running copies, 
or to cache after displaying, these settings will still apply when the display is 
docked. 
Docking multiple displays in the same position 
You can also run more than one docked display in the same position, if the 
additional displays are the Overlay or On Top type. 
For example, if you use /DT to dock a menu to the top of the client window, 
and then use /DT to open another display, as long as the second display is of 
the type Overlay or On Top type, it will run directly beneath the first. 
C# PDF Library SDK to view, edit, convert, process PDF file for C#
editing PDF document hyperlink (url) and quick navigation link in PDF bookmark. C#.NET: Edit PDF Metadata. PDF SDK for .NET allows you to read, add, edit, update
add a link to a pdf file; convert a word document to pdf with hyperlinks
C# Image: How to Download Image from URL in C# Project with .NET
Add this imaging library to your C#.NET project jpeg / jpg, or bmp image from a URL to your provide powerful & profession imaging controls, PDF document, tiff
adding hyperlinks to a pdf; change link in pdf file
Chapter 16                  Creating graphic displays 
444 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
If you dock a Replace type of display, it will close any other displays running 
in the same position. For more about display type, see Specifying the display 
type on page 432
Running other displays in the available client area 
The size and position of docked graphic displays in the FactoryTalk View 
SE Client window determines where in the window other graphic displays 
can run. 
For example, if you dock a display named Menu at the top of the SE Client 
window, and then run a display named Line1, it will run in the area not 
occupied by the docked display. 
If Line1 is larger than the available client area, scroll bars will be provided 
for gaining access to the hidden portion of the display. If you opened Line1 
first, and then ran the Menu display with a docking parameter, Line1 would 
be repositioned in the client window, to accommodate the Menu display. 
In the following illustration, the FactoryTalk View SE Client window 
contains three docked menus (top, left, and bottom), and a graphic display 
named Primary Treatment is running in the available client area. 
Closing docked displays 
Use the Abort command to close docked displays individually, or to close all 
docked displays, and any other displays running in the FactoryTalk View 
SE Client window. 
C# PDF insert image Library: insert images into PDF in C#.net, ASP
C#.NET PDF SDK - Add Image to PDF Page in C#.NET. How to Insert & Add Image, Picture or Logo on PDF Page Using C#.NET. Add Image to PDF Page Using C#.NET.
pdf link to email; add hyperlink in pdf
C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
Insert Image to PDF. Image: Remove Image from PDF Page. Cut Image in Page. Link: Edit URL. Bookmark: Edit Images. Redact Pages. Annotation & Drawing. Add Sticky Note
adding hyperlinks to pdf files; add a link to a pdf in acrobat
Creating graphic displays                  Chapter 16 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
445 
Example: Closing an individual docked display 
To provide the operator with a way to close a docked display named Menu, 
create a button in the display that uses this command as its press action: 
Abort Overview
When the operator presses the button, the Menu display will close. 
Example: Closing all docked displays 
To provide the operator with a way to close all docked displays, along with 
any other displays running in the FactoryTalk View SE Client window, 
create a client key that uses this command as its press action: 
Abort * /D
When the operator presses the key, all running displays will close. 
Tip: The Abort 
command’s
/D parameter, which closes any 
docked displays, is valid only when used with Abort *. 
To let an operator print graphic displays at run time, when you create the 
displays, provide a way for the operator to run the PrintDisplay command. 
For example, create a button object, display key, or client key with the 
PrintDisplay command as the press action. 
When you use the PrintDisplay command, FactoryTalk View prints the 
entire display, even if parts are covered by other displays. You can use the 
ScreenPrint command to print an image of whatever shows on the monitor. 
For more information about the PrintDisplay and ScreenPrint commands, 
see the FactoryTalk View Site Edition Help. 
Printing displays at 
run time 
VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
to PDF. Image: Remove Image from PDF Page. Image Link: Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete Redact Pages. Annotation & Drawing. Add Sticky Note
add hyperlink to pdf acrobat; adding hyperlinks to pdf documents
VB.NET Image: VB Code to Download and Save Image from Web URL
Apart from image downloading from web URL, RasterEdge .NET Imaging SDK still dedicated to provide powerful & profession imaging controls, PDF document, image
add links to pdf acrobat; pdf hyperlink
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
447 
Chapter 17 
Creating graphic objects 
This chapter describes how to use, create, and set up the graphic objects 
available in FactoryTalk View Site Edition. 
For information about using the Graphics editor, and creating and setting up 
graphic displays, see Creating graphic displays on page 391
In FactoryTalk View Studio, in the Graphics editor, you can create the 
following types of graphic objects: 
Drawing objects are geometric and freehand objects, images, panels, 
and text. Drawing objects are the only FactoryTalk View graphic 
objects that do not use data connections. For more information, see 
Creating the different types of drawing objects on page 450
Push button objects are typically used to start or stop processes or 
actions. For more information, see Creating the different types of push 
buttons on page 458
Numeric and string objects are used for entering or displaying 
numbers or text. For more information, see Creating the different types 
of data display and input objects on page 469
Indicator objects show the status of a process or operation by showing 
colors, captions, images, or options to indicate different states. For 
more information, see Creating the different types of indicators on 
page 475
Gauge and graph objects show a range of values, and relationships 
between variables. For more information, see Creating the different 
types of gauges and graphs on page 477
Key objects represent keys on a keyboard, and are for use with touch 
screens. For more information, see Using key objects to simulate 
keyboard functions on page 480
Advanced objects, such as trends and HMI tag alarm summaries, 
provide ways for operators to monitor, analyze, and interact with 
application data at run time. For more information, see Creating the 
different types of advanced objects on page 482
Some advanced objects are described in detail in other parts of this 
manual. For information about creating trend objects, see Setting up 
trends on page 601
Types of graphic 
objects in 
FactoryTalk View 
SE 
Chapter 17                  Creating graphic objects 
448 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
For information about creating HMI tag alarm summaries, see Setting 
up HMI tag alarms on page 217
Alarm and Event objects such as the alarm and event summary and 
the alarm status explorer, provide ways for FactoryTalk View SE users 
to monitor and control FactoryTalk Alarms and Events. 
For information about the Alarm and Event objects, see Setting up 
FactoryTalk alarms on page 261
OLE objects such as spreadsheets, charts, or text, are produced by 
other Windows applications. The OLE objects that are available 
depend on the software installed on the system. For information, see 
Working with OLE objects on page 503
ActiveX objects such as gauges, or sliders, can be created using a tool 
like Visual Basic or purchased from a third-party vendor, and then set 
up to initiate an action in FactoryTalk View. 
For more information, see Working with ActiveX object on page 504, 
and Animating ActiveX objects on page 536
Import objects such as graphics from file. 
Symbol Factory a library of graphic objects that can be imported into 
a Graphic Display. 
About global objects 
You can create FactoryTalk View global objects to link the appearance and 
behavior of one graphic object to multiple copies of the object in the same 
application. 
Any graphic object you can create in FactoryTalk View can be a global 
object, except for ActiveX controls, OLE objects, and HMI tag alarm 
summaries. For more information, see Creating global objects on page 497
For information about global object displays, see Creating graphic displays 
on page 391. 
After creating a graphic object, you can use the Properties dialog box to set 
up its appearance and behavior. 
Opening the Properties dialog box: 
To open the Properties dialog box for an object, use one of these methods: 
For some objects, the Properties dialog box opens directly, when you 
create the object. 
For other objects, you open the Properties dialog box by 
double-clicking the object after you create it. 
Setting up the 
properties of 
graphic objects 
Creating graphic objects                  Chapter 17 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
449 
You can also right-click the object, and then select Properties. 
The following illustration shows the Properties dialog box for a polygon 
object. 
In the Properties dialog box, the features of the object are organized in tabs. 
The number of tabs and their contents depend on the type of object. For 
details about options in any Properties dialog box, click Help
Setting up properties common to all objects 
There is a Common tab in the Properties dialog box for every FactoryTalk 
View graphic object. Use the Common tab to set up these properties for the 
object: 
Height and width 
Top and left position 
Name 
Tooltip 
Visibility 
For ActiveX objects, trends, and Alarm and Event objects, you can also set 
up these properties: 
Focus highlight 
Pointer highlight 
Key navigation 
Tab index 
Chapter 17                  Creating graphic objects 
450 
Rockwell Automation Publication VIEWSE-UM006K-EN-E 
To draw simple objects such as lines, rectangles, and ellipses, in the 
Graphics editor, select drawing tools from the Objects menu or toolbar. 
The drawing tool for an object has the name of the object. To draw a 
rectangle or square, for example, select the Rectangle tool. 
After selecting a drawing tool, draw the object by dragging the tool, or by 
clicking end points. You can draw rectangles, ellipses, and arcs only by 
dragging; you can draw polylines and polygons only by clicking end points. 
Drawing a rectangle or square 
Use 
to draw a rectangle or square. 
To draw a rectangle: 
Drag 
diagonally, until the rectangle is the desired size. 
To draw a square: 
Press Ctrl while you drag 
Drawing a rounded rectangle 
Use 
to draw a rectangle with rounded corners. 
To draw a rounded rectangle: 
Drag 
diagonally, until the rounded rectangle is the desired size. 
To change a rounded rectangle into a right-angle rectangle: 
1.  Position the pointer on the small box shown inside the rounded 