NIM BLE  TECH N ICAL R EP O RT: V M WA RE SI TE REC OV ERY  M AN AGER  AN D N IM B LE STO RA GE 
11  
quiescent for the virtual machines being protected. Doing so ensures recoverability of 
application data from a point-in-time backup copy.  
Nimble Storage has built-in integration with both Microsoft Volume Shadow Service (VSS) 
framework and VMware Tools VSS implementation. The type of disk connectivity method 
dictates the volume collection synchronization method. The three virtual storage connectivity 
methods are discussed below, along with the design consideration for each: 
NOTE:  
Ensure only VMs needing DR protection are placed in volumes configured with 
replication. VMs that that need to failover together should also reside on the same 
volume collection, to ensure consistent snapshot and replication schedule 
A manual volume snapshot initiated from Nimble UI or vCenter Server plugin would 
NOT trigger the VSS requestor to request for application quiescing. Ensure a snapshot 
schedule is in place for the Volume Collection for proper VSS application quiescing 
Both vCenter Server and SRM databases should have a regular snapshot and 
replication schedule. It is also recommended to add a manual schedule after each DR 
test, recovery, and reprotect task. Remember a scheduled snapshot is needed to 
trigger proper VSS quiescing of I/O 
Here’s a quick summary of each virtual storage connectivity method, along with design 
considerations: 
RDM(Physical Compatibility Mode) for application disks, VMDK for OS disk 
Add links to pdf file - insert, remove PDF links in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Free C# example code is offered for users to edit PDF document hyperlink (url), like inserting and deleting
pdf link; active links in pdf
Add links to pdf file - VB.NET PDF url edit library: insert, remove PDF links in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Help to Insert a Hyperlink to Specified PDF Document Page
add hyperlinks to pdf online; pdf link to attached file
NIM BLE  TECH N ICAL R EP O RT: V M WA RE SI TE REC OV ERY  M AN AGER  AN D N IM B LE STO RA GE 
12  
Contain both
VMFS & RDM 
volumes
This method involves using RDM for application data and VMDK for VM guest OS. With this 
method, VMware ESXi server will simply ignore the RDM disk during VMware snapshot 
operation, meaning vSphere will only create a VMware snapshot for the O/S VMDK. As for 
the application disk that is running as RDM, the Nimble VSS hardware provider will be used 
for snapshots. Therefore, it is imperative to ensure the Volume Collection containing the RDM 
and VMDK volumes has “Microsoft VSS” synchronization selected.
NOTE: 
With “Microsoft VSS” sy
nchronization, there would be NO VMware snapshot taken by 
ESXi servers. The Nimble VSS hardware provider will be leverage for taking the 
snapshot, after the VSS writer has successfully freeze incoming I/O requests 
The Nimble Windows Toolkit (Nimble Protection Manager/NMP) needs to be installed 
on the VM that has RDM storage attached 
VMDK for both application and OS disks 
C# PDF Convert to HTML SDK: Convert PDF to html files in C#.net
HTML converter toolkit SDK, preserves all the original anchors, links, bookmarks and to Use C#.NET Demo Code to Convert PDF Document to Add necessary references
convert excel to pdf with hyperlinks; clickable links in pdf
C# Create PDF Library SDK to convert PDF from other file formats
PDF with a blank page, bookmarks, links, signatures, etc. metadata adding control, you can add some additional information to generated PDF file.
add hyperlink to pdf acrobat; add hyperlink to pdf online
NIM BLE  TECH N ICAL R EP O RT: V M WA RE SI TE REC OV ERY  M AN AGER  AN D N IM B LE STO RA GE 
13  
Array based 
snapshot happens 
when ALL VMs in 
VMFS are 
quiescedg
This method involves using VMDK for both VM guest OS and application data. With this 
method, keep in mind that ALL VMs in a given VMFS volume need to be quiesced to take 
VMware snapshot, follow by the Nimble array taking an array level snapshot. It is a best 
practice, if using this method, to limit the number of virtual machines that reside on the given 
VMFS volume on which the quiescence is being issued. This will minimize both the number 
of VMs impacted by the suspend operation as well as improve the speed with which the 
snapshot can be taken.  
NOTE: 
The current VMware implementation of the software VSS provider does NOT truncate 
logs for Microsoft applications such as Exchange, SQL Server or Sharepoint. If you 
have an integrated backup application such as Commvault that could be invoked to 
truncate the logs, be sure to leverage that. If not, you could:  
o
enable circular logging in Exchange;  
o
consider in-guest/RDM mounted storage, and  
o
build custom script to invoke during backup to truncate the Exchange logs. 
In-guest attached iSCSI storage for Application Data, VMDK for OS disk 
VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.
Embed PDF hyperlinks to HTML links in VB.NET. Add necessary references: This professional .NET solution that is designed to convert PDF file to HTML web page
adding links to pdf; clickable links in pdf files
.NET PDF Document Viewing, Annotation, Conversion & Processing
Add, edit, delete links. Form Process. Fill in form data programmatically. Read form data from PDF form file. Add, Update, Delete form fields programmatically.
pdf links; clickable links in pdf from word
NIM BLE  TECH N ICAL R EP O RT: V M WA RE SI TE REC OV ERY  M AN AGER  AN D N IM B LE STO RA GE 
14  
Contain both
VMFS & in-
guest mounted 
volumes
Snapshot clone 
should have in-
guest iQN (NOT 
ESX sw/iscsi
iQN)
This method involves using a VMDK for the VM guest OS disk, and in-guest attached iSCSI 
storage for application data. With this method, the in-guest attached storage will bypass the 
ESXi storage stack, and appear as network traffic to ESXi server. Typical use cases for this 
configuration are:  
Using Microsoft Clustering Service (MSCS) on iSCSI protocol, and  
Reaching beyond the 2TB VMDK size limitation.  
Just like the other two connectivity methods, there are design considerations and tradeoffs. 
NOTE: 
SRM does not know about in-guest attached storage, therefore during recovery extra 
steps are required to mount these volumes for each VM that uses this type of storage.  
The Nimble Protection Manager (NPM) needs to be installed on the VM with in-guest 
attached iSCSI storage 
With the correct Volume Collection Synchronization setting, each scheduled snapshot is 
application consistent. Therefore, when the scheduled snapshots get replicated to the Nimble 
replication partner array, the new replica is also application consistent. 
C# PDF Convert to Word SDK: Convert PDF to Word library in C#.net
the original text style (including font, size, color, links and boldness). Add necessary references This is a C# programming example for converting PDF to Word
adding a link to a pdf; change link in pdf
How to C#: Basic SDK Concept of XDoc.PDF for .NET
You may add PDF document protection functionality into your C# program. to edit hyperlink of PDF document, including editing PDF url links and quick
c# read pdf from url; convert doc to pdf with hyperlinks
NIM BLE  TECH N ICAL R EP O RT: V M WA RE SI TE REC OV ERY  M AN AGER  AN D N IM B LE STO RA GE 
15  
RTO and RPO 
RTO (Recovery Time Objective) and RPO (Recovery Point Objective) are two key factors in 
architecting a disaster recovery solution that meets the Service Level Objective (SLO) for the 
business. 
RTO refers to how quickly a business can recover from the disaster, or specifically how long 
it takes to execute the recovery process to bring back business services. RTO is typically 
measured in minutes or hours. Site Recovery Manager is what automates the recovery and 
maximizes the RTO of a vSphere DR solution. 
RPO refers to how far back in time the data in the environment will be, once the business 
service is restored. RPO is typically measured in minutes. Nimble Storage replication 
provides the aggressive RPOs demanded of a DR solution. 
The integrated SRM solution with Nimble Storage will enable end users accelerate their RTO, 
as the configuration, DR test, recovery and failback are simplified and automated. The best 
practice is to conduct regular DR testing to ensure the RTO is met consistently and 
repeatedly.  
For RPO, here are the key design considerations for each factor that affects RPO: 
VB.NET PDF: Basic SDK Concept of XDoc.PDF
You may add PDF document protection functionality into your VB.NET program. to edit hyperlink of PDF document, including editing PDF url links and quick
add url pdf; add links to pdf document
VB.NET Create PDF Library SDK to convert PDF from other file
save editable PDF with a blank page, bookmarks, links, signatures, etc. Add necessary references class programming, you can use specific APIs to create PDF file.
add hyperlink to pdf in; accessible links in pdf
NIM BLE  TECH N ICAL R EP O RT: V M WA RE SI TE REC OV ERY  M AN AGER  AN D N IM B LE STO RA GE 
16  
NOTE: 
Both VMware vSphere and Nimble Storage have built-in features to reduce replication 
footprint, to make more efficient use of WAN bandwidth. 
VM Swap File Location in vSphere: 
Place all the virtual machine swap files in a dedicated VMFS datastore without replication 
enabled. By doing this it will eliminate replication of transient virtual machine data, reducing 
the amount of bandwidth needed to protect a virtual machine and saving on time and cost of 
replication. VM swap files are recreated automatically by SRM when the recovery copies of 
the virtual machines are powered on. This setting can be found in the Cluster Features 
setting in vCenter Server: 
Replication Policy: 
Replication data reduction is enabled by default. All volumes created in Nimble array have 
“Compression” enabled.
Leaving it enabled is a best practice as the snapshot data is also 
compressed. Additionally, the Nimble replication engine eliminates data duplication by only 
replicating the delta between the primary and replica volume. By sending only deduplicated 
and compressed data, the amount of time necessary to replicate a virtual machine is shrunk, 
enabling better RPOs for the environment. 
If the WAN connection is shared with other critical applications, QoS policies could be 
created to limit the amount of bandwidth used by Nimble Storage at the network layer 
(switch/firewall) or at Nimble Storage Replication Bandwidth configuration menu: 
NIM BLE  TECH N ICAL R EP O RT: V M WA RE SI TE REC OV ERY  M AN AGER  AN D N IM B LE STO RA GE 
17  
Base Infrastructure Service 
Base infrastructure service such as Active Directory (AD), Domain Name Resolution (DNS), 
and HTTP are core to the business services applications. Therefore, it is imperative to ensure 
these services are running at all times in Recovery Site to ensure successful DR testing, 
recovery and failback.  
NOTE: 
AD should not be replicated using storage replication technology, as it could potentially cause 
a USN rollback scenario. Refer to Microsoft KB 888794 for further details: 
(http://support.microsoft.com/kb/888794
Configure high availability for AD by having at least two instances of AD server, both 
configured as a Global Catalog Server. Additional considerations for AD are listed in the  
Test, Recovery, and Reprotect Section. 
In almost all scenarios it is most favorable to have fully active Active Directory and DNS 
services already running at the recovery site. This will minimize the amount of change 
necessary to fail over an environment to the recovery location, granting a better recovery 
time. It will also ensure no last-minute changes are needed for the authentication/DNS 
environments that may prove difficult to overcome during a disaster, giving you more reliable 
DR. 
NIM BLE  TECH N ICAL R EP O RT: V M WA RE SI TE REC OV ERY  M AN AGER  AN D N IM B LE STO RA GE 
18  
Network 
If both your datacenters are located on the same Layer Two network or on a stretched VLAN, 
you could skip this section. If you have to change IP addresses for a small number of virtual 
machines during DR test, recovery, you could leverage the VM Recovery Properties wizard in 
the Recovery Plan, for each virtual machine: 
NOTE: 
Ensure the Network Mapping is configured properly for the Recovery Site: 
NIM BLE  TECH N ICAL R EP O RT: V M WA RE SI TE REC OV ERY  M AN AGER  AN D N IM B LE STO RA GE 
19  
If you have to change IP addresses for a large number of VMs (for example, hundreds of 
VMs), then you should consider automating this process with the SRM DR IP Customizer 
tool. More information about this tool can be found here: http://pubs.vmware.com/srm-
51/index.jsp?topic=%2Fcom.vmware.srm.admin.doc%2FGUID-9794F585-C168-48D6-8866-
E8519E768278.html 
If it is possible to run the recovery site with the same network IP ranges, this will allow you to 
fail over virtual machines without reconfiguration. For optimal recovery time stretched layer 2 
networking is recommended to avoid the time required to change networking for all virtual 
machines.  
If a stretched layer 2 network is not achievable in your environment, SRM can automatically 
reconfigure networking for virtual machines upon failover as outlined above. 
DR Testing 
One of key aspects of meeting DR RPO and RTO is testing. It is a good practice to test DR 
recovery process on a regular basis. Here are the key design considerations for DR testing 
with SRM and Nimble Storage: 
NOTE: 
Ensure base infrastructure service could be verified during DR testing.  This means all critical 
application VMs could join the domain, end users and applications could authenticate against 
AD, and the application components could communicate on the network. By default, SRM 
has a test bubble network that gets created without real network connectivity. Follow the 
recommendations and best practices below to truly verify infrastructure service availability 
during DR test: 
NIM BLE  TECH N ICAL R EP O RT: V M WA RE SI TE REC OV ERY  M AN AGER  AN D N IM B LE STO RA GE 
20  
NOTE: 
For applications that require the FSMO roles in the Active Directory forest. Refer to Microsoft 
KB 255504 (http://support.microsoft.com/kb/255504) for procedure to seize the FSMO roles 
during DR test.  
Here’s a high level wor
kflow of infrastructure preparation and cleanup for DR testing: 