how to disable save option in pdf using c# : Endnote pdf metadata Library software class asp.net winforms windows ajax ZVL_Operating_008_V3_2014-part1053

R&S ZVL 
GUI Reference 
Nwa-File Menu 
Operating Manual 1303.6580.32-06 
125
Remote control:
MEMory:DEFine "<setup_name>"
Close 
Closes an opened setup window. The analyzer suggests to save changes to the setup before closing it. If 
asetup is closed without saving, all changes made since the last time it was saved are lost.  
Remote control:
MEMory:DELete[:NAME] "<setup_name>"
Recall Nwa 
Recalls an existing setup from a file. The analyzer opens a standard Windows™ Open dialog box to select 
the file from all NWA setup files (*.nwa) stored on the file system.  
It is not possible to open the same setup in different windows. If an opened setup is changed and an 
attempt is made to open the same setup again the analyzer displays a warning:   
Yes overwrites the changes in the opened setup, No closes the message box, leaving the opened setup 
unchanged.  
It is possible to create and open several setup files with the same contents but different names or 
locations. To open/recall a setup file (*.nwa) you can also use the Windows Explorer and simply double-
click the file or drag and drop the file into the NWA application. The imported setup becomes the active 
setup.  
Setups for different network analyzer models 
It is possible to transfer setups between different R&S ZVL network analyzers, even if they belong 
to different analyzer types. To be loaded into an R&S ZVL13 network analyzer, a test setup file 
created with an R&S ZVL3 or R&S ZVL-6 must not use the following setting:  
–A point trigger (Channel – Sweep – Trigger – Trigger Settings:Point)   
–A measurement delay (Channel – Sweep – Meas Delay)  
Remote control:
MMEMory:LOAD:NWANalyzer 1,"<file_name>" 
Open Dialog 
Specifies the name and location of a particular file (e.g. a NWA setup file) to open: 
Look in specifies the drive and directory in which the file to open is stored. The icons to the right of 
the pull-down list are provided for easy navigation in the file system (place the cursor on the icons 
to obtain What's this? help). 
File Name specifies a file name (e.g. a setup file, *.nwa) to open. The file can be selected by 
clicking on the directory overview above.  
Open opens selected file and closes the dialog.  
Endnote pdf metadata - add, remove, update PDF metadata in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# Developers to Read, Add, Edit, Update and Delete PDF Metadata
remove metadata from pdf online; batch update pdf metadata
Endnote pdf metadata - VB.NET PDF metadata library: add, remove, update PDF metadata in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Enable VB.NET Users to Read, Write, Edit, Delete and Update PDF Document Metadata
view pdf metadata in explorer; online pdf metadata viewer
R&S ZVL 
GUI Reference 
Nwa-File Menu 
Operating Manual 1303.6580.32-06 
126
Cancel closes the dialog without opening a setup file.  
Save Nwa 
Saves an opened setup to its current name and directory. On saving a setup for the first time, the analyzer 
displays the Save As dialog box in order to name the setup file.  
To change the name and directory of an existing setup before saving it, choose the Save As 
command. If you store device settings file to the C:\R_S\Instr\RecallShortCut directory, you can 
recall them using the FILE – Recall Shortcuts submenu.  
Save Nwa As 
Saves and names the active setup. The analyzer opens a standard Windows™ Save As dialog box to 
select a NWA setup file name (*.nwa) and location for the setup file.  
To save a document with its existing name and directory, use the Save command. If you store device 
settings file to the C:\R_S\Instr\RecallShortCut directory, you can recall them using the FILE – 
Recall Shortcuts submenu.  
Remote control:
MMEMory:STORe:NWANalyzer 1,"<file_name>"
Save As Dialog 
Specifies the name and location of a particular file (e.g. a NWA setup file) to save: 
File Name specifies a file name to save the current data (e.g. the setup). The analyzer adds the 
extension (e.g. *.nwa) in the Save As Type box.  
Save in specifies the drive and directory in which the data is stored. The icons to the right of the 
pull-down list are provided for easy navigation in the file system (place the cursor on the icons to 
obtain What's this? help). 
Save saves the data (e.g. the active setup) in the selected file and directory and closes the dialog.  
Cancel closes the dialog without saving the data.  
C# Word - Footnote & Endnote Processing in C#.NET
C# Word - Footnote & Endnote Processing in C#.NET. Provide Variety of C# Methods to Process Footnote & Endnote in Word Document. Create Footnote & Endnote.
adding metadata to pdf; c# read pdf metadata
C# Word - Word Create or Build in C#.NET
Create Word Document from Existing Files Using C#. Create Word From PDF. Create Word From PowerPoint. Footnote & Endnote Processing.
delete metadata from pdf; pdf remove metadata
R&S ZVL 
GUI Reference 
Nwa-File Menu 
Operating Manual 1303.6580.32-06 
127
The Save As dialog is used to store various data types (e.g. cal kit data, limit lines, sweep segment 
lists, ...). Depending on its use the dialog is opened with different file locations and data types. File 
locations (directories) are remembered when the dialog is closed. To restore default directories use 
the System – System Configuration – Resets dialog.   
Page Setup 
Opens the Page Setup dialog box to select print options. 
Page Setup Dialog 
Provides options to specify how the document should be printed. Page Setup is opened by means of the 
Nwa-File – Page Setup... command.  
The radio buttons in the Print panel specify whether or not different diagram areas are printed on 
different pages. 
The Logo check box specifies if the R&S logo is included in the printed document.  
Additional print settings are available via the PRINT key (see section Setup Keys). 
Recent File 
Is a placeholder which is replaced by a list of the last 4 setups stored in the current or in previous 
sessions. Clicking an item in the list opens the corresponding setup.  
Use the setup list in the Window menu to switch between different open setups.  
Remote control: MEMory:CAT? (returns a list of the loaded files).
Exit Firmware 
Ends the analyzer session. The analyzer prompts you to save setups with unsaved changes. 
This command is equivalent to the Close command on the application Control menu.  
C# Word - Convert Word to PDF in C#.NET
Word: Convert Word to PDF. C# Word - Convert Word to PDF in C#.NET. Online C# Tutorial for Converting Word to PDF (.pdf) Document. Word to PDF Conversion Overview
pdf metadata; pdf xmp metadata
C# Word - Insert Image to Word Page in C#.NET
Footnote & Endnote Processing. Table Row Processing. Table Cell Processing. Annotate Word. text in PDF, C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET
extract pdf metadata; pdf xmp metadata editor
R&S ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-06 
128
Trace Menu     
The Trace menu provides all trace settings and the functions to select, modify and store different traces. In 
addition the menu provides the marker, search and limit check functions.  
Traces 
Atrace is a set of data points that can be displayed together in a diagram area. The trace settings specify 
the mathematical operations used in order to obtain traces from the collected data. They can be divided 
into several main groups: 
Selection of the measured quantity (S-parameters, wave quantities, ratios, impedances,...)  
Conversion into the appropriate display format and selection of the diagram type  
Scaling of the diagram and selection of the traces associated with the same channel  
Readout and search of particular values on the trace by means of markers  
Limit check  
The trace settings complement the definitions of the Channel menu. Each trace is assigned to a channel; 
see Traces, Channels and Diagram Areas. The channel settings apply to all traces assigned to the 
channel.   
(No direct access via front panel keys)
The Trace menu contains the following functions and submenus: 
Trace -> stores traces to the memory and performs mathematical operations on traces.   
Marker -> defines the sweep range, scales the diagram and introduces an electrical length offset 
using the active marker.   
Marker positions markers on a trace, configures their properties and selects the format of the 
numerical readout.    
Meas selects the quantity to be measured and displayed. 
Format defines how the measured data is presented in the graphical display.  
Scale defines how the current trace is presented in the diagram selected in the Format submenu.  
Lines defines limits for measured values and activates the limit check.   
Trace ->     
The Trace -> submenu stores traces to the memory and performs mathematical operations on traces.  
Refer to section Trace Types in the System Overview chapter to learn more about data traces, 
memory traces, and mathematical traces.  
How to C#: Generate Thumbnail for Word
Footnote & Endnote Processing. Table Row Processing. Table Cell Processing. Annotate Word. text in PDF, C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET
pdf metadata reader; read pdf metadata
C# Word - Document Processing in C#.NET
Provide a Series of Methods to Setup Document Properties and Modify Document Content for Users.
metadata in pdf documents; pdf metadata editor
R&S ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-06 
129
Traces opens a submenu with functions to handle traces and diagram areas, and assign traces to 
channels.  
Data -> Mem stores the active data trace as a memory trace.  
Math = Data/Mem activates the mathematical mode where the data trace is divided by the 
memory trace.  
Math = Data-Mem activates the mathematical mode where the memory trace is subtracted from 
the data trace.  
Show Data shows or hides the active data trace.  
Show Mem shows or hides the active memory trace.  
Trace Statistics opens a submenu to evaluate statistical and phase information of the trace.  
Time Domain Transform opens a submenu to view the measurement results as a function of time 
(with option ZVAB-K3, Time Domain). 
Smoothing On activates the smoothing function for the active trace.  
Smoothing Aperture... defines how many measurement points are averaged to smooth the trace.  
Import/Export Data stores the active trace to a file or loads a memory trace from a file.   
Shift Response Value... opens a dialog to define a user-correction to the measured values.  
Shift Stimulus Value... shifts a memory trace in horizontal direction.   
Max Hold On enables or disables the max hold (peak hold) function for the active trace.  
Restart Hold restarts the max hold (peak hold) function for the active trace, discarding the old 
maximum measurement results.  
Many of the functions of the Trace Funct menu act on the active trace. Data traces and the associated 
memory traces share many of their properties; see coupling of memory traces.  
Data -> Mem  
Stores the current state of the active trace as a memory trace. The memory trace is displayed in the active 
diagram area with another color, and its properties are indicated in the trace list:  
Memory traces are named Mem<n>[<Data_Trace>] where <n> counts all data and memory traces in the 
active setup in chronological order, and <Data_Trace> is the name of the associated data trace. Trace 
names can be changed in the Trace Manager dialog. 
C# Word - Delete Word Document Page in C#.NET
Provides Users with Mature Document Manipulating Function for Deleting Word Pages.
endnote pdf metadata; adding metadata to pdf
C# Word - Extract or Copy Pages from Word File in C#.NET
Footnote & Endnote Processing. Table Row Processing. Table Cell Processing. Annotate Word. text in PDF, C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET
pdf keywords metadata; batch update pdf metadata
R&S ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-06 
130
The exact function of Data -> Mem depends on the number of memory traces associated with the active 
data trace: 
If no memory trace is associated with the active trace, a new memory trace is generated. 
If several memory traces are associated with the active trace, the current measurement data 
overwrites the last generated or changed memory trace.   
Coupling of data and memory traces 
When a memory trace is generated from a data trace, it is displayed in the same diagram area and 
inherits all channel and trace settings from the data trace.  
The following display settings of a data trace and the associated memory traces are fully coupled.
Changing a property of one trace affects the properties of all other traces.   
All settings in the Trace – Format menu  
All settings in the Trace –  Scale menu  
Selection of the measured quantity (Trace – Meas) is possible for the data trace but disabled for the 
memory traces.  
Channel settings made for a memory trace act on the associated data trace. Some of the channel settings 
for a data trace (e.g. the Stimulus range) also affect the display of the memory traces.  
If the sweep type of a data trace is changed so that the stimulus ranges of the data traces and the 
memory traces become incompatible, all coupled memory traces are removed from the diagram area and 
deleted.     
Remote control:
CALCulate<Chn>:MATH:MEMorize
Math = Data/Mem  
Activates the mathematical mode where the active data trace is divided by the last generated memory 
trace. The division is calculated on a point-to-point basis: Each measurement point of the active trace is 
divided by the corresponding measurement point of the memory trace. The result of the division is a 
mathematical trace and replaces the active data trace in the diagram area. The mathematical trace is 
updated as the measurement goes on and the analyzer provides new active trace data.   
This function is disabled unless a memory trace is coupled to the active data trace. Trace coupling 
ensures that the two traces have the same number of points and that the mathematical trace Data/Mem is 
well-defined.  
Remote control: CALCulate<Chn>:MATH:FUNCtion DIVide 
Math = Data-Mem  
Activates the mathematical mode where the last generated memory trace is subtracted from the active 
data trace. The subtraction is calculated on a point-to-point basis: Each measurement point of the memory 
trace is subtracted from the corresponding measurement point of the active trace. The result of the 
subtraction is a mathematical trace and replaces the active data trace in the diagram area. The 
mathematical trace is updated as the measurement goes on and the analyzer provides new active trace 
data.   
This function is disabled unless a memory trace is coupled to the active data trace. Trace coupling 
ensures that the two traces have the same number of points and that the mathematical trace Data-Mem is 
C# Word - Insert Blank Word Page in C#.NET
Guide C# Users to Insert (Empty) Word Page or Pages from a Supported File Format.
get pdf metadata; batch pdf metadata
C# Word - Word Creating in C#.NET
Tell Users How to Create New Word File and Load Word from Other Files.
acrobat pdf additional metadata; remove metadata from pdf
R&S ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-06 
131
well-defined.  
Remote control:
CALCulate<Chn>:MATH:FUNCtion SUBTract 
Show Data 
Displays or hides the active data trace in the diagram area. If the mathematical option Math = Data/Mem 
or Math = Data-Mem is active, then the active mathematical trace is displayed or hidden. 
Remote control:
No command, display configuration only. 
Show Mem 
Displays or hides the active memory trace in the diagram area or the memory trace associated with the 
active data trace.  
If no memory trace is associated with the active data trace, Show Mem is disabled. 
Remote control: No command, display configuration only. 
Traces     
The Traces submenu provides functions to handle traces and diagram areas, and assign traces to 
channels.  
Select Trace opens a box to select an arbitrary trace of the active setup as the active trace 
(disabled if only one trace is defined).   
Add Trace creates a new trace in the current diagram area. 
Add Trace + Diag. Area generates a new trace in a new diagram area.  
Delete Trace deletes the active trace.  
Assign Diag. Area assigns the active trace to another diagram area. 
Assign Channel assigns the active trace to another channel. 
Trace Manager opens a dialog to perform the previous actions systematically for all traces and 
diagram areas.   
R&S ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-06 
132
Active and inactive traces 
The screen can display several diagram areas simultaneously, each with a variable number of traces.  
In an active diagram area one of these traces is the active trace. The active trace is highlighted in 
the trace list on top of the diagram area (Trc 3 in the figure below): 
If an inactive area is selected as the active area, the trace that was active last time when the area 
was active will again become the active trace. It is highlighted in the trace list of the inactive 
diagram area as shown for Trc6 in the figure below: 
All settings in the Trace menu except the Trace Functions involving a memory trace apply to the active 
trace in the active diagram area.  
In remote control each channel can contain an active trace. The active remote traces and the active 
manual trace are independent of each other; see Active Traces in Remote Control.   
Select Trace 
Opens a box to select an arbitrary trace of the active setup as the active trace. This function is disabled if 
only one trace is defined.  
Remote 
control: 
The numeric suffix <Ch / Tr> appended to the first-level mnemonic of a command 
selects a trace as active trace. 
Add Trace 
Creates a new trace in the current diagram area and assigns it to the current channel. The new trace is 
created with the trace and channel settings of the former active trace but displayed with another color. The 
former and the new active trace are superimposed but can be easily separated, e.g. by changing the 
Reference Position. 
The new trace is named Trc <n>, where <n> is the largest of all existing trace numbers plus one. The 
name can be changed in the Trace Manager.
To create a new trace in a new channel, use Channel – Channel Select – Add Chan + Trace. 
Remote 
control: 
CALCulate<Ch>:PARameter:SDEFine <Trace Name>, < Meas Parameter> 
DISPlay:WINDow<Wnd>:TRACe<WndTr>:FEED 
R&S ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-06 
133
Add Trace + Diag. Area 
Creates a new trace in a new diagram area and assigns the trace to the current channel. The new trace is 
created with the trace and channel settings of the former active trace but displayed with another color.  
The new trace is named Trc <n>, where <n> is the largest of all existing trace numbers plus one. The 
name can be changed in the Trace Manager.
Remote control: CALCulate<Ch>:PARameter:SDEFine <Trace Name>, < Meas Parameter> 
DISPlay:WINDow<Wnd>:STATe ON 
DISPlay:WINDow<Wnd>:TRACe<WndTr>:FEED  
Delete Trace 
Deletes the current trace and removes it from the diagram area. Delete Trace is disabled if the setup 
contains only one trace: In manual control, each setup must contain at least one diagram area with one 
channel and one trace.
To restore a trace that was unintentionally deleted, use Undo.
Remote control: CALCulate<Ch>:PARameter:DELete <Trace Name> 
Assign Diag Area 
Assigns the active trace to another diagram area. A popup window offers a list of all areas available:  
Selecting one of the existing area numbers assigns the active trace to the existing diagram area: 
The active trace is removed from the previous area and displayed in the new diagram area. 
Selecting New creates a new diagram area and assigns the active trace to the new area. The new 
area is numbered <n>, where <n> is the largest of all existing area numbers plus one.  
Assign Diag. Area is disabled if the current setup contains only one area. To create an additional 
area, click Display – Area Select – New Diag. Area. 
To go to another diagram area and activate the last active trace in this area, simply click a point 
inside the new area.  
Remote control:
DISPlay:WINDow<Wnd>:TRACe<WndTr>:FEED <Trace Name> 
Assign Channel 
Assigns the active trace to another channel. A popup window offers a list of all channels available:  
R&S ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-06 
134
Selecting one of the existing channel names assigns the current trace to the existing channel. 
Selecting New creates a new channel and assigns the current trace to the new channel. The new 
channel is named Ch <n>, where <n> is the largest of all existing channel numbers plus one. The 
name can be changed in the Channel Manager.  
Remote control: CALCulate<Ch>:PARameter:SDEFine <Trace Name>, < Meas Parameter> 
Trace Manager 
Opens a dialog to perform the actions in the Trace Select menu systematically for all traces and diagram 
areas. 
All existing traces of the current setup are listed in a table with several editable (white) or non-editable 
(gray) columns. Below the table the Trace Manager provides the following buttons: 
Add/Delete... opens a dialog to add a new trace or delete a trace. 
Coupling opens a dialog to define coupling criteria (channel, scale) for all traces in the table.  
Sort Table opens a dialog to change the order of the traces (rows) in the table. 
Columns in the Trace Manager table 
Name indicates the current trace name. The default names for new traces are Trc<n> where <n> 
is a current number. Current numbers in the trace names are necessary to make automatic 
assignments, e.g. decouple the channel settings in the Coupling dialog.  
On indicates whether the trace is displayed on the screen (On) or invisible.  
Meas indicates the measured parameter. 
Type indicates whether the trace is a data trace (DAT), displaying the current measurement data, 
or a memory trace (MEM).
Channel indicates the channel of each trace.  
Area indicates the diagram area of each trace.  
Scale shows which traces use common scaling and format settings.  
Rules for trace names 
For trace names, the following restrictions apply: 