R&S ZVL 
GUI Reference 
FILE Key 
Operating Manual 1303.6580.32-06 
285
Use the Trace – Trace – Import/Export Data submenu to export or import trace data in Network 
Analyzer mode. 
Hardcopy 
Opens the PRINT menu.  
File Manager 
Opens the File Manager dialog box and a submenu to manage mass storage media and files. In the upper 
left corner, the current drive is displayed. Below the folders and subfolders of the current directory are 
displayed.  
The following tasks can be performed: 
to copy files from flash disk to other media 
to copy files into another directory 
to rename and delete files 
Navigation in the File Manager 
To change from one subfolder to another, use the ENTER key. 
To change to the next higher directory, select the dots "..". 
To change into a subfolder, use the Cursor Right and Cursor Left keys.  
To select a file or a folder, use the Cursor Up and Cursor Down keys.  
To confirm the selection of a file or folder, press the ENTER key. 
Menu (Key) Submenu 
Submenu / Command
Command 
FILE g
File Manager g
Edit Path 
New Folder 
Copy 
Rename 
Cut 
Paste 
More g
Delete 
Sort Mode g
Name 
Pdf metadata viewer - add, remove, update PDF metadata in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# Developers to Read, Add, Edit, Update and Delete PDF Metadata
pdf xmp metadata; change pdf metadata creation date
Pdf metadata viewer - VB.NET PDF metadata library: add, remove, update PDF metadata in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Enable VB.NET Users to Read, Write, Edit, Delete and Update PDF Document Metadata
pdf metadata extract; remove metadata from pdf
R&S ZVL 
GUI Reference 
FILE Key 
Operating Manual 1303.6580.32-06 
286
Date 
Extension 
Size 
File Lists 1/2 
Current File List 1/2 
Network Drive 
Map Network Drive 
Disconnect Network Drive 
Edit Path 
Opens the directory list to select the folder in which the device configuration is to be stored or loaded. The 
default path is C:\R_S\Instr\user. For details see also Navigation in the dialog boxes for saving and 
loading data sets. 
Remote Control: 
MMEM:MSIS "D:" 
MMEM:CDIR "C:\R_S\Instr\user" 
New Folder 
Creates a new folder and opens an edit dialog box to enter name and path (absolute or relative to the 
current directory) of the new folder. 
Remote Control: 
MMEM:MDIR "C:\R_S\Instr\user\TEST" 
Copy 
Copies the selected item to the clipboard. The item can be copied later using the Paste softkey. 
Remote Control: 
MMEM:COPY "C:\R_S\Instr\user\set.cfg","E:" 
Rename 
Opens an edit dialog box to enter a new file or folder name.  
Remote Control: 
MMEM:MOVE "test02.cfg","set2.cfg" 
Cut 
Copies the selected file to the clipboard. If the file is later copied to a different directory using the Paste 
VB.NET PDF - WPF PDF Viewer for VB.NET Program
C#.NET PDF Create, C#.NET PDF Document Viewer, C#.NET PDF Windows Viewer, C#.NET search text in PDF, C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET
modify pdf metadata; embed metadata in pdf
VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
C#.NET PDF Create, C#.NET PDF Document Viewer, C#.NET PDF Windows Viewer, C#.NET search text in PDF, C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET
extract pdf metadata; edit pdf metadata acrobat
R&S ZVL 
GUI Reference 
FILE Key 
Operating Manual 1303.6580.32-06 
287
softkey, it is deleted in the current directory.  
Paste 
Copies a file from the clipboard to the currently selected directory. 
Delete 
Deletes the selected item after confirmation.  
Remote Control: 
MMEM:DEL "test01.hcp" 
MMEM:RDIR "C:\R_S\Instr\user\TEST" 
Sort Mode 
Opens a submenu to select the sorting mode for the displayed files. The entry for the next higher directory 
level ("..") and the folders are always located at the top of the list. 
Name 
Sorts the displayed files in alphabetical order of the file names. 
Date 
Sorts the displayed files in respect to the date. 
Extension 
Sorts the displayed files in respect to the extension. 
Size 
Sorts the displayed files in respect to the size. 
File Lists 1/2 
Splits the screen to copy files from one directory to the other. The focus between the two panes is 
switched using the FIELD RIGHT and FIELD LEFT keys. 
Current File List 1/2 
Changes the focus to the selected file list. 
Network Drive 
Opens a dialog to map a drive to a server or server folder of the network. As a prerequisite in Microsoft 
networks, sharing of this server or server folder must be enabled.  
How to C#: Modify Image Metadata (tag)
C#.NET PDF Create, C#.NET PDF Document Viewer, C#.NET PDF Windows Viewer, C#.NET search text in PDF, C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET
google search pdf metadata; get pdf metadata
C# PDF Library SDK to view, edit, convert, process PDF file for C#
RasterEdge WPF PDF Viewer provides C# users abilities to view, annotate, convert and create PDF in WPF application. C#.NET: Edit PDF Metadata.
adding metadata to pdf files; pdf xmp metadata viewer
R&S ZVL 
GUI Reference 
SETUP Key 
Operating Manual 1303.6580.32-06 
288
Remote Control: 
MMEM:NETW:USED  
MMEM:NETW:UNUS? 
Map Network Drive 
Changes the focus to the Drive list. 
Remote Control: 
MMEM:NETW:MAP 
Disconnect Network Drive 
Opens a dialog to disconnect a (previously connected) network drive.   
Remote Control: 
MMEM:NETW:DISC 
SETUP Key 
The SETUP key is used to set or display the default settings of the instrument: reference frequency, date, 
time, LAN interface, firmware update and enabling of options, information about instrument configuration 
and service support functions.  
The following table shows all softkeys available in the setup menu. It is possible that your instrument 
configuration does not provide all softkeys. If a softkey is only available with a special option, model or 
(measurement) mode, this information is delivered in the corresponding softkey description. 
Submenu / Command
Submenu / Command 
Submenu / Command 
Reference Int/Ext 
General Setup g
Configure Network 
Network Address g
Computer Name 
IP Address 
Subnet Mask 
DHCP On/Off 
LXI g
LAN Status On/Off 
Info 
Password 
Description 
C# WPF PDF Viewer SDK to view, annotate, convert and print PDF in
PDF Online. Convert PDF Online. WPF PDF Viewer. View PDF in Image to PDF. Image: Remove Image from PDF Page. Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete
remove metadata from pdf acrobat; batch edit pdf metadata
C# TIFF: TIFF Metadata Editor, How to Write & Read TIFF Metadata
C# TIFF - Edit TIFF Metadata in C#.NET. Allow Users to Read and Edit Metadata Stored in Tiff Image in C#.NET Application. How to Get TIFF XMP Metadata in C#.NET.
preview edit pdf metadata; pdf remove metadata
R&S ZVL 
GUI Reference 
SETUP Key 
Operating Manual 1303.6580.32-06 
289
LAN Reset 
GPIB g
GPIB Address 
ID String Factory 
ID String User 
GPIB Language 
Display Update On/Off 
More g
GPIB Terminator LFEOI/EOI 
*IDN Format Leg./ZVL 
I/O Logging On/Off 
Time+Date 
Meas Display g
Display Pwr Save On/Off 
More g
Monitor Int/Ext 
Soft Frontpanel 
Open Start Menu 
More g
Firmware Update g
Firmware Update 
Option Licenses g
Install Option 
Shutdown Off/Standby 
Preset Network 
Preset Spectrum 
System Info g
Hardware Info 
Versions+Options 
System Messages 
Clear All Messages 
C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
PDF Online. Convert PDF Online. WPF PDF Viewer. View PDF in Image to PDF. Image: Remove Image from PDF Page. Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete
metadata in pdf documents; pdf metadata reader
VB.NET PDF Library SDK to view, edit, convert, process PDF file
PDF Metadata Edit. Offer professional PDF document metadata editing APIs, using which VB.NET developers can redact, delete, view and save PDF metadata.
pdf metadata viewer online; remove pdf metadata online
R&S ZVL 
GUI Reference 
SETUP Key 
Operating Manual 1303.6580.32-06 
290
Service g
Reset Password 
Selftest 
Selftest Results 
Password 
Service Function 
Reference Int/Ext 
Switches between the internal and external reference signal source. The default setting is internal 
reference. It is important, that the external reference signal is deactivated when switching from external to 
internal reference to avoid interactions. 
If the reference signal is missing when switching to external reference, the message EXREF is displayed 
to indicate that no synchronization is possible. 
The R&S ZVL can use the internal reference source or an external reference source as frequency 
standard from which all internal oscillators are derived. A 10 MHz crystal oscillator is used as internal 
reference source. In the external reference setting, all internal oscillators of the R&S ZVL are 
synchronized to the external reference frequency (also 10 MHz).  
Remote Control: 
ROSC:SOUR INT 
Firmware Update 
Opens a submenu to install firmware versions. The installation of a new firmware version can be 
performed via USB or LAN interface; see Firmware Update. With firmware versions V3.00 and higher, a 
user account with administrator rights is necessary to install a printer (see Operation with and without 
Administrator Rights). 
Firmware Update 
Opens the Firmware Update dialog box. The update path is changed by entering the new path or via the 
Browse button. The installation is started via the Execute button; see Firmware Update.
Remote Control: 
SYST:FIRM:UPD 'D:\FW_UPDATE' 
Option Licenses 
Opens  a  submenu  to  install  options. With  firmware  versions  V3.00  and  higher,  a  user  account  with 
administrator rights is necessary to install a printer (see Operation with and without Administrator Rights). 
R&S ZVL 
GUI Reference 
SETUP Key 
Operating Manual 1303.6580.32-06 
291
Install Option 
Opens an edit dialog box to enter the license key for the option that you want to install. A message box 
opens if an option is about to expire or has already expired (in which case all functions (including remote 
control) are unavailable until the R&S ZSL is rebooted). For more information about the option in question 
refer to the System Info softkey in the setup menu. 
Shutdown Off/Standby 
Defines the effect of the power on/off key on the front panel, if the R&S ZVL is AC-supplied (see 
Instrument States with AC Power Supply):  
Off: The instrument is completely turned off. To prevent the instrument from overheating, the fan 
remains active.  
Standby: The instrument is switched to standby mode.   
Preset Network 
Sets the preset mode to network analyzer. The instrument is set to this mode when a preset is performed 
(PRESET key or *RST command). 
Preset Spectrum 
Sets the preset mode to spectrum analyzer. The instrument is set to this mode when a preset is performed 
(PRESET key or *RST command). 
General Setup 
Opens a submenu for all general settings such as IP address and LAN settings, date and time, remote 
control (optional) and MEAS display.  
Menu (Key) 
Submenu 
Submenu / Command
Submenu / Command 
SETUP g
General Setup g
Configure Network 
Network Address g
LXI g
GPIB g
Time+Date 
Meas Display g
More g
Monitor Int / Ext 
Soft Frontpanel 
R&S ZVL 
GUI Reference 
SETUP Key 
Operating Manual 1303.6580.32-06 
292
Open Start Menu  
Configure Network 
Opens the Network Connections dialog box to change the LAN settings. See Remote Control in a LAN. 
Time+Date 
Opens an edit dialog box to enter time and date for the internal real time clock.  
Remote Control: 
SYST:TIME 12,30 
SYST:DATE 2004,10,01 
Meas Display 
Opens a submenu with the Display Pwr Save On/Off softkey. 
The Display Pwr Save On/Off softkey switches the power–save mode for the display on/off and opens an 
edit dialog box to enter the time for the power–save function to respond. After the elapse of this time the 
display is completely switched off, i.e. including backlighting. This mode is recommended when the 
instrument is exclusively operated in remote control.  
Remote Control: 
DISP:PSAV ON 
DISP:PSAV:HOLD 15 
Monitor Int/Ext 
Activates the R&S ZVL front panel display (Int) or an external monitor to display the screen contents. An 
external monitor must be connected to the DVI connector on the rear panel of the instrument.  
Soft Frontpanel 
Activates or deactivates the display of the front panel keys on the screen. The soft frontpanel is 
recommended for control of the instrument from an external monitor or a Remote Desktop connection.  
Alternatively, F6 enables or disables the soft frontpanel. 
Remote Control: 
SYST:DISP:FPAN ON 
Open Start Menu  
Opens Windows XP's start menu from where you can access program utilities such as Windows XP's on-
screen keyboard. The R&S ZVL application is not closed.   
R&S ZVL 
GUI Reference 
SETUP Key 
Operating Manual 1303.6580.32-06 
293
Network Address 
Opens a submenu to configure the internet protocol properties and the computer name. 
Menu (Key)
Submenu 
Submenu 
Command 
SETUP g
General Setup g
Network Address g
Computer Name 
IP Address 
Subnet Mask 
DHCP On/Off 
Computer Name 
Opens an edit dialog box to enter the computer name via the keypad. The naming conventions of 
Windows apply. If too many characters and/or numbers are entered, in the status line, a message is 
displayed.  
IP Address 
Opens an edit dialog box to enter the IP address via the keypad. The TCP/IP protocol is preinstalled with 
the IP address 10.0.0.10. If the DHCP server is available (DHCP On), the dialog box entry is read–only. 
The IP address consists of four number blocks separated by dots. Each block contains 3 numbers in 
maximum (e.g. 100.100.100.100), but also one or two numbers are allowed in a block (as an example see 
the preinstalled address).  
Subnet Mask 
Opens an edit dialog box to enter the subnet mask via the keypad. The TCP/IP protocol is preinstalled 
with the subnet mask 255.255.255.0. If the DHCP server is available (DHCP On), the dialog box entry is 
read–only. 
The subnet mask consists of four number blocks separated by dots. Each block contains 3 numbers in 
maximum (e.g. 100.100.100.100), but also one or two numbers are allowed in a block (as an example see 
the preinstalled address).  
DHCP On/Off 
Switches between DHCP server available (On) or not available (Off). If a DHCP server is available in the 
network, the IP address and subnet mask of the instrument are obtained automatically from the DHCP 
server.  
LXI Configuration Menu 
Opens the LXI submenu containing the following softkeys:  
R&S ZVL 
GUI Reference 
SETUP Key 
Operating Manual 1303.6580.32-06 
294
Menu (Key) 
Submenu 
Submenu / 
Command 
Submenu / 
Command 
SETUP g
General 
Setup g
LXI g
LAN Status On/Off 
Info 
Password 
Description 
LAN Reset 
For a description of the LXI browser interface of the R&S ZVL refer to LXI Configuration. 
LAN Status On/Off 
Activates the LAN status bar that shows the current status of the LAN connection. Depending on the 
status of the connection, the LXI logo assumes the following states:  
Red: no connection is established  
Green: connection established 
Blinking: the device could not be identified  
Info 
Shows the current LXI parameters of the analyzer. The R&S ZVL displays the current LXI version, LXI 
class and various system parameters like computer name or IP adress. 
While active, the dialog is not updated. 
Remote control: 
SYSTem:LXI:INFO?  
Password 
Shows the current LXI password. You can also change the current password using this softkey. Some 
settings in the LXI web browser (e.g. IP parameters) are password-protected. An empty password is not 
valid, i.e. you must enter a password. 
By default, the password is LxiWebIfc.  
Remote control: 
SYSTem:LXI:PASSword  
Description 
Opens a dialog box to view or change the LXI instrument description. This description appears on the LXI 
browser interface. By default, the description contains the serial number of the network analyzer.  
Documents you may be interested
Documents you may be interested