R&S ZVL 
Remote Control 
Messages 
Operating Manual 1303.6580.32-05 
325
Example: 
SOUR:RFG:FREQ 1.5GHz is equivalent to 
SOUR:RFG:FREQ 1.5E9 
Special numeric values 
The texts MINimum, MAXimum, DEFault, UP and DOWN are interpreted as special numeric values. A 
query returns the associated numerical value.  
Example: 
Setting command: SENSe:FREQuency:STARt  MINimum 
The query SENSe:FREQuency:STARt? returns 300000 (the exact value depends on the analyzer 
model). 
The following special values can be used: 
MIN/MAX MINimum and MAXimum denote the minimum and maximum value of a range of 
numeric values.  
DEF DEFault denotes the preset value. This value is set by the *RST command.  
UP/DOWN UP, DOWN increases or reduces the numeric value by one step. The step width is 
reported in the detailed command description.  
INF/NINF Negative INFinity (NINF) represent the numerical values –9.9E37 or +9.9E37, 
respectively. INF and NINF are only sent as device responses.  
NAN Not a Number (NAN) represents the value 9.91E37. NAN is only sent as device response. 
This value is not defined. Possible causes are division by zero, subtraction or addition of infinite 
and the representation of missing values.  
Unless it is explicitly stated in the command description you can use the special numeric parameters 
for all commands of the analyzer.  
Boolean Parameters 
Boolean parameters represent two states. The ON state (logically true) is represented by ON or a 
numerical value different from 0. The OFF state (logically false) is represented by OFF or the numerical 
value 0. A query responds with 0 or 1. 
Example: Setting command: SWEep:TIME:AUTO ON 
Query: SWEep:TIME:AUTO? returns 1 
Text Parameters 
Text parameters observe the syntax rules for key words, i.e. they can be entered using a short or long 
form. Like any parameter, they have to be separated from the header by a white space. In the case of a 
query, the short form of the text is provided.  
Example: Setting command: TRIGger:SOURce EXTernal 
Query: TRIGger:SOURce? returns EXT 
Get pdf metadata - add, remove, update PDF metadata in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# Developers to Read, Add, Edit, Update and Delete PDF Metadata
online pdf metadata viewer; modify pdf metadata
Get pdf metadata - VB.NET PDF metadata library: add, remove, update PDF metadata in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Enable VB.NET Users to Read, Write, Edit, Delete and Update PDF Document Metadata
metadata in pdf documents; pdf metadata viewer online
R&S ZVL 
Remote Control 
Messages 
Operating Manual 1303.6580.32-05 
326
Strings 
Strings must always be entered within single or double quotation marks (' or "). 
Example: CONFigure:CHANnel:NAME "Channel 4" or  
CONFigure:CHANnel:NAME 'Channel 4' 
Block Data Format 
Block data is a transmission format which is suitable for the transmission of large amounts of data. A 
command using a block data parameter with definite length has the following structure: 
Example:  HEADer:HEADer #45168xxxxxxxx 
The hash symbol # introduces the data block. The next number indicates how many of the following digits 
describe the length of the data block. In the example the 4 following digits indicate the length to be 5168 
bytes. The data bytes follow. During the transmission of these data bytes all End or other control signs are 
ignored until all bytes are transmitted. 
A#0 combination introduces a data block of indefinite length. The use of the indefinite format requires a 
NL^END message to terminate the data block. This format is useful when the length of the transmission is 
not known or if speed or other considerations prevent segmentation of the data into blocks of definite 
length.  
Overview of Syntax Elements 
:
The colon separates the key words of a command. In a command line the 
separating semicolon marks the uppermost command level. 
;
The semicolon separates two commands of a command line. It does not alter 
the path. 
,
The comma separates several parameters of a command. 
?
The question mark forms a query. 
*
The asterisk marks a common command. 
', 
"
Quotation marks introduce a string and terminate it. 
#
The hash sign # introduces binary, octal, hexadecimal and block data. 
Binary: #B10110 
Octal: #O7612 
Hexadecimal: #HF3A7 
Block: #21312 
A "white space" (ASCII-Code 0 to 9, 11 to 32 decimal, e.g. blank) separates 
header and parameter. 
C# TIFF: TIFF Metadata Editor, How to Write & Read TIFF Metadata
TIFFDocument doc = new TIFFDocument(@"c:\demo1.tif"); // Get Xmp metadata for string. TagCollection collection = doc.GetTagCollection(0); // Get Exif metadata.
endnote pdf metadata; adding metadata to pdf files
VB.NET PDF Annotate Library: Draw, edit PDF annotation, markups in
' Get PDF document. Dim fileInpath As String = "" Dim doc As PDFDocument = New PDFDocument(fileInpath) ' Get all annotations. ' Get PDF document.
edit multiple pdf metadata; pdf xmp metadata
R&S ZVL 
Remote Control 
Basic Remote Control Concepts 
Operating Manual 1303.6580.32-05 
327
Basic Remote Control Concepts     
The functionality of the network analyzer's remote control commands has been defined in close analogy to 
the menu commands and control elements of the graphical user interface (GUI). The basic concepts of 
setups, traces, channels, and diagram areas remain valid in remote control. Moreover, all commands 
follow SCPI syntax rules, and SCPI-confirmed commands have been used whenever possible. These 
principles largely simplify the development of remote control scripts.  
The GUI and the remote control command set both aim at maximum operating convenience. In manual 
control this generally means that the control elements are easy to find and intuitive to handle, and that the 
effect of each operation is easy to verify on the screen. Convenient remote control operation depends on a 
simple and systematic program syntax and on a predictable instrument state; the display of results is 
secondary.    
These differences suggest the peculiarities in the analyzer's remote control concept discussed in the 
following sections.  
Traces, Channels, and Diagram Areas     
Like in manual control, traces can be assigned to a channel and displayed in diagram areas (see section 
Traces, Channels and Diagram Areas in Chapter 3). There are two main differences between manual and 
remote control: 
Atrace can be created without being displayed on the screen.  
Achannel must not necessarily contain a trace. Channel and trace configurations are independent 
of each other.   
The following frequently used commands create and delete traces, channels, and diagram areas:  
Create new trace 
and new channel  
(if channel <Ch> 
does not exist 
yet) 
CALCulate<Ch>:PARameter:SDEFine '<Trace Name>', 
'< Meas Parameter> 
Delete trace 
CALCulate<Ch>:PARameter:DELete <Trace Name> 
Create or delete 
channel 
CONFigure:CHANnel<Ch>[:STATe] ON | OFF 
Create or delete 
diagram area 
DISPlay:WINDow<Wnd>:STATe ON | OFF 
Display trace in 
diagram area 
DISPlay:WINDow<Wnd>:TRACe<WndTr>:FEED 
The assignment between traces, channels, and diagram areas is defined via numeric suffixes as 
illustrated in the following example:  
CALC4:PAR:SDEF 'Ch4Tr1', 'S11'  
Create channel 4 (channel suffix 4) and a trace named Ch4Tr1 to measure the input reflection coefficient 
S
11
.The trace is created but not displayed. 
C# PDF Annotate Library: Draw, edit PDF annotation, markups in C#.
Get PDF document. String fileInpath = @""; PDFDocument doc = new PDFDocument(fileInpath); // Get all annotations. Get PDF document.
analyze pdf metadata; batch edit pdf metadata
How to C#: Modify Image Metadata (tag)
VB.NET How-to, VB.NET PDF, VB.NET Word, VB.NET Excel How to C#: Modify Image Metadata (tag). With XImage.Raster, you can get the image tags and modify them rapidly
pdf metadata editor; remove pdf metadata online
R&S ZVL 
Remote Control 
Basic Remote Control Concepts 
Operating Manual 1303.6580.32-05 
328
DISP:WIND2:STAT ON  
Create diagram area no. 2 (window suffix 2).  
DISP:WIND2:TRAC9:FEED 'CH4TR1' 
Display the generated trace (identified by its name Ch4Tr1) in diagram area no. 2 (window suffix 2), 
assigning the trace number 9 (trace suffix 9) to it.  
Active Traces in Remote Control     
In manual control there is always exactly one active trace, irrespective of the number of channels and 
traces defined. The active channel contains the active trace; see section Trace Settings in Chapter 3.  
In remote control, each channel contains an active trace (unless the channel contains no trace at all), so 
the notion of active channel is meaningless. This principle actually simplifies the remote control command 
syntax, because it allows the active trace in a particular channel to be referenced by means of the channel 
suffix. No additional trace identifier is needed; there is no need either to distinguish channel and trace 
settings using mnemonics or suffixes.  
The active traces are handled as follows:  
After a preset (*RST), the analyzer displays a single diagram area with the default trace no. 1 
named TRC1. The trace is active in manual and in remote control.  
In manual control, a new, added trace automatically becomes the active trace. To select another 
trace as the active trace, click inside the trace list.  
In remote control, a new trace added via CALCulate<Ch>:PARameter:SDEFine 
'<trace_name>', '<parameter>' also becomes the active trace. To select another trace as 
the active trace, use (CALCulate<Ch>:PARameter:SELect '<trace_name>').  
The active traces for manual and remote control may be different.   
VB.NET PDF: Get Started with PDF Library
rotate PDF pages, C#.NET search text in PDF, C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET VB.NET PDF: Get Started with .NET PDF Library Using VB.
c# read pdf metadata; pdf metadata editor online
C# PDF Image Extract Library: Select, copy, paste PDF images in C#
Scan image to PDF, tiff and various image formats. Get image information, such as its location, zonal information, metadata, and so on.
edit pdf metadata acrobat; batch pdf metadata
R&S ZVL 
Remote Control 
Basic Remote Control Concepts 
Operating Manual 1303.6580.32-05 
329
The following program example illustrates how to create, select and reference traces. It is instructive to 
observe the analyzer screen in order to check the effect of each step.  
*RST  
Reset the analyzer, creating channel no. 1 with the default trace Trc1. The trace is displayed in diagram 
area no. 1.  
CALC1:PAR:SDEF 'Trc2', 'S11'; DISP:WIND:TRAC2:FEED 'Trc2'  
Create a new trace named Trc2, assigned to channel no. 1 (the suffix 1 after CALC, may be omitted), and 
display the trace. The new trace automatically becomes the active trace for manual and for remote control. 
To check this, click Trace – Marker –  Marker 1 to create a marker. The marker is assigned to Trc2. Delete 
all markers (Trace – Marker –  All Markers Off).  
CALC1:MARK ON  
To verify that Trc2 is also active for remote control, use the channel suffix 1 after CALC (may be omitted) 
to reference the active trace in channel 1 and create a marker Mkr 1. The marker is assigned to Trc2.
CALC:PAR:SEL 'Trc1'; CALC1:MARK ON  
Select the old default trace Trc1 as the active trace for remote control. Create a new marker to verify that 
Trc1 is now the active trace in channel 1.   
In the SCPI command description, the numeric suffix <Ch> is used for channel settings (it 
denotes the configured channel), whereas <Chn> is used for trace settings (it denotes the 
active trace in the channel).  
Initiating Measurements, Speed Considerations     
After a reset the network analyzer measures in continuous mode. The displayed trace shows the result of 
the last sweep and is continuously updated. This provides a permanent visual control over the 
measurement and the effect of any analyzer settings.  
In remote control, it is advisable to follow a different approach in order use the analyzer's resources to full 
capacity and gain measurement speed. The following principles can help to optimize a remote control 
program (see also programming example Typical Stages of a Measurement):  
Switch off the measurement while configuring your instrument.  
Use a minimum number of suitably positioned sweep points.  
Start a single sweep, observing proper command synchronization, and retrieve your results.  
The following command sequence performs a single sweep in a single channel.   
*RST; INITiate:CONTinous OFF  
Activate single sweep mode for all channels (including the channels created later).  
INITiate:SCOPe SING  
State that a single sweep will be performed in the active channel only.  
INITiate[:IMMediate]; *WAI  
Start a single sweep in channel no. 2, wait until the sweep is terminated before proceeding to the next 
command (see Command Synchronization).   
VB.NET PDF Image Extract Library: Select, copy, paste PDF images
Capture image from whole PDF based on special characteristics. Get image information, such as its location, zonal information, metadata, and so on.
change pdf metadata creation date; preview edit pdf metadata
C# PDF Page Extract Library: copy, paste, cut PDF pages in C#.net
You can easily get pages from a PDF file, and then use these pages to create and output a new PDF file. Pages order will be retained.
edit pdf metadata online; read pdf metadata online
R&S ZVL 
Remote Control 
Command Processing 
Operating Manual 1303.6580.32-05 
330
Command Processing 
The block diagram below shows how GPIB bus commands are serviced in the instrument.  
The individual components work independently and simultaneously. They communicate with each other by 
means of so-called "messages". 
Input Unit 
The input unit receives commands character by character from the controller and collects them in the input 
buffer. The input unit sends a message to the command recognition as soon as the input buffer is full or as 
soon as it receives a delimiter, <PROGRAM MESSAGE TERMINATOR>, as defined in IEEE 488.2, or the 
interface message DCL.  
If the input buffer is full, the message data traffic is stopped and the data received up to then is processed. 
Subsequently the traffic is continued. If, however, the buffer is not yet full when receiving the delimiter, the 
input unit can already receive the next command during command recognition and execution. The receipt 
of a DCL clears the input buffer and immediately initiates a message to the command recognition. 
Command Recognition 
The command recognition stage analyzes the data received from the input unit. It proceeds in the order in 
which it receives the data. Only a DCL is serviced with priority, e.g. a GET (Group Execute Trigger) is only 
executed after the commands received before. Each recognized command is immediately transferred to 
the data set but not executed immediately.  
C# PDF insert text Library: insert text into PDF content in C#.net
String inputFilePath = Program.RootPath + "\\" 1.pdf"; PDFDocument doc = new PDFDocument(inputFilePath); // get a text manager from the document object
get pdf metadata; pdf metadata extract
R&S ZVL 
Remote Control 
Command Processing 
Operating Manual 1303.6580.32-05 
331
The command recognition detects syntax errors in the commands and transfers them to the status 
reporting system. The rest of a command line after a syntax error is still executed, if possible. After the 
syntax check, the range of the numerical parameters is checked, if required.  
If the command recognition detects a delimiter or a DCL, it also requests the data set to perform the 
necessary instrument hardware settings. Subsequently it is immediately prepared to process further 
commands. This means that new commands can already be serviced while the hardware is still being set 
("overlapping execution").  
Data Base and Instrument Hardware 
The expression "instrument hardware" denotes the part of the instrument fulfilling the actual instrument 
function – signal generation, measurement etc. The controller is not included. The data base manages all 
the parameters and associated settings required for the instrument hardware.   
Setting commands lead to an alteration in the data set. The data set management enters the new values 
(e.g. frequency) into the data set, however, it only passes them on to the hardware when requested by the 
command recognition. This can only occur at the end of a command line, therefore the order of the setting 
commands in the command line is not relevant.  
The commands are only checked for their compatibility among each other and with the instrument 
hardware immediately before they are transmitted to the instrument hardware. If the instrument detects 
that execution is not possible, an "execution error" is signalled to the status reporting system. All 
alterations of the data set are cancelled, the instrument hardware is not reset. Due to the delayed 
checking and hardware setting, however, impermissible instrument states can be set for a short period of 
time within one command line without this leading to an error message (example: simultaneous activation 
of a frequency and a power sweep). At the end of the command line, however, a permissible instrument 
state must have been reached again.  
Before passing on the data to the hardware, the settling bit in the STATus:OPERation register is set (cf. 
section STATus:OPERation Register). The hardware executes the settings and resets the bit again as 
soon as the new state has settled. This fact can be used to synchronize command servicing.  
Queries induce the data set management to send the desired data to the output unit. 
Status Reporting System 
The status reporting system collects information on the instrument state and makes it available to the 
output unit on request. The exact structure and function are described in section Status Reporting System. 
Output Unit 
The output unit collects the information requested by the controller, which it receives from the data set 
management. It processes it according to the SCPI rules and makes it available in the output buffer. If the 
information requested is longer, it is made available "in portions" without this being recognized by the 
controller. 
If the instrument is addressed as a talker without the output buffer containing data or awaiting data from 
the data set management, the output unit sends the error message "Query UNTERMINATED" to the 
status reporting system. No data is sent on the GPIB bus or via the Ethernet, the controller waits until it 
has reached its time limit. This behavior is specified by SCPI. 
R&S ZVL 
Remote Control 
Command Processing 
Operating Manual 1303.6580.32-05 
332
Command Sequence and Command Synchronization 
IEEE 488.2 defines a distinction between overlapped and sequential commands:  
Asequential command is one which finishes executing before the next command starts executing. 
Commands that are processed quickly are usually implemented as sequential commands.  
An overlapping command is one which does not automatically finish executing before the next 
command starts executing. Usually, overlapping commands take longer to process and allow the 
program to do other tasks while being executed. If overlapping commands do have to be executed 
in a defined order, e.g. in order to avoid wrong measurement results, they must be serviced 
sequentially. This is called synchronization between the controller and the analyzer.  
According to section Data Set and Instrument Hardware, setting commands within one command line, 
even though they may be implemented as sequential commands, are not necessarily serviced in the order 
in which they have been received. In order to make sure that commands are actually carried out in a 
certain order, each command must be sent in a separate command line. Examples:  
Example 1: Commands and queries in one message  
The response to a query combined in a program message with commands that affect the queried value is 
not predictable. Sending  
:FREQ:STAR 1GHZ;SPAN 100 
:FREQ:STAR? 
always returns 1000000000 (1 GHz). When: 
:FREQ:STAR 1GHz;STAR?;SPAN 1000000 
is sent, however, the result is not specified by SCPI. The result could be the value of STARt before the 
command was sent since the instrument might defer executing the individual commands until a program 
message terminator is received. The result could also be 1 GHz if the instrument executes commands as 
they are received. 
As a general rule, send commands and queries in different program messages. 
Example 2: Overlapping command with *OPC  
The analyzer implements INITiate[:IMMediate] as an overlapped command. Assuming that 
INITiate[:IMMediate] takes longer to execute than *OPC, sending the command sequence  
INIT; *OPC. 
results in initiating a sweep and, after some time, setting the OPC bit in the ESR. Sending the commands:  
INIT; *OPC; *CLS 
still initiates a sweep. Since the operation is still pending when the analyzer executes *CLS, forcing it into 
the Operation Complete Command Idle State (OCIS), *OPC is effectively skipped. The OPC bit is not set 
until the analyzer executes another *OPC command.  
The analyzer provides only one overlapped command, INITiate<Ch>[:IMMediate].
What is said below is not relevant for the other (sequential) SCPI commands.   
R&S ZVL 
Remote Control 
Status Reporting System 
Operating Manual 1303.6580.32-05 
333
Preventing overlapping execution 
To prevent an overlapping execution of commands, one of the commands *OPC, *OPC? or *WAI can be 
used. For a programming example refer to section Command Synchronization in Chapter Programming 
Examples. 
Command 
Action after the hardware has settled 
Programming the controller 
*WAI 
Stops further command
processing until all 
commands sent before *WAI have been 
executed  
Note: The GPIB bus handshake is not stopped 
Send *WAI directly after the command 
which should be terminated before the 
next command is executed.  
*OPC? 
Stops command processing until 1 is returned, 
i.e. until the Operation Complete bit has been set 
in the ESR. This bit indicates that the previous 
commands have been completed.  
Send *OPC? directly after the 
command which should be terminated 
before the next command is executed.  
*OPC 
Sets the operation complete bit in the ESR 
after all previous commands have been 
executed. 
–Set bit 0 in the ESE 
–Set bit 5 in the SRE 
–Wait for service request (SRQ) 
Status Reporting System 
The status reporting system stores all information on the present operating state of the instrument, and on 
errors which have occurred. This information is stored in the status registers and in the error queue. Both 
can be queried via GPIB bus or Ethernet (STATus... commands). 
Hierarchy of status registers 
As shown in the graphical overview, the status information is of hierarchical structure.  
STB, SRE The STatus Byte (STB) register and its associated mask register Service Request 
Enable (SRE) form the highest level of the status reporting system. The STB provides a rough 
overview of the instrument status, collecting the information of the lower-level registers.  
ESR, SCPI registers 
The STB receives its information from the following registers: 
The Event Status Register (ESR) with the associated mask register standard event status 
enable (ESE).  
The STATus:OPERation and STATus:QUEStionable registers which are defined by SCPI 
and contain detailed information on the instrument.  
IST, PPE The IST flag ("Individual STatus"), like the SRQ, combines the entire instrument status in 
asingle bit. The PPE is associated to the IST flag. It fulfills an analogous function for the IST flag 
as the SRE does for the service request.  
Output buffer contains the messages the instrument returns to the controller. It is not part of the 
status reporting system but determines the value of the MAV bit in the STB and thus is 
represented in the overview.  
All status registers have the same internal structure. 
R&S ZVL 
Remote Control 
Status Reporting System 
Operating Manual 1303.6580.32-05 
334
The service request enable register SRE can be used as ENABle part of the STB if the STB 
is structured according to SCPI. By analogy, the ESE can be used as the ENABle part of the 
ESR.  
Overview of Status Registers 
The status registers of the network analyzer are implemented as shown below.  
STB
STATus:OPERation Register
& =logical AND
=logical OR
of all bits
Error Queue
RQS/MSS
MAV
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
STATus:QUEStionable Register
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
STATus:QUEStionable
:LIMit1 Register
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
STATus:QUEStionable
:LIMit2 Register
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
STATus:QUEStionable:INTegrity Register
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
STATus:QUEStionable
:INTegrity:HARDware Register
Documents you may be interested
Documents you may be interested