download pdf c# : Endnote pdf metadata SDK Library API .net asp.net web page sharepoint ZVL_Operating_008_V3_2040-part1082

R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
385
as a fixed marker.  
CALC:MARK:REF:X 1GHz   
Shift the marker horizontally. The response value remains fixed.  
CALCulate<Chn>:MARKer<Mk>:REFerence:X <numeric_value> 
Defines the stimulus (in Cartesian diagrams: x-axis) value of the reference marker, which can (but doesn't 
have to) be displayed using CALCulate<Chn>:MARKer<Mk>:REFerence[:STATe] ON.
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10. This numeric suffix is ignored and may 
be set to any value.  
<numeric_value> 
Stimulus value of the reference marker.  
Range [def. unit] 
–9.9E+11 Hz to +9.9E+11 Hz [Hz] 
*RST value 
0Hz  
SCPI, Command 
Types 
Device-specific, command or query.  
Example: 
Suppose that the active setup contains an active trace no. 1 and that the 
sweep range for a frequency sweep starts at 1 GHz.  
CALC:MARK:REF ON  
Create the reference marker and display it in the center of the sweep range.  
CALC:MARK:REF:X 1GHz  
Set the reference marker to the beginning of the sweep range.  
CALCulate<Chn>:MARKer<Mk>:REFerence:Y? 
Returns the response (in Cartesian diagrams: y-axis) value of the reference marker. The reference marker 
must be created before using CALCulate<Chn>:MARKer<Mk>:REFerence[:STATe] ON.
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10. This numeric suffix is ignored and may be 
set to any value.  
Response 
Response value of the reference marker.   
Range [def. unit] 
Depending on the measured quantity. [unit depending on the marker format; see 
CALCulate<Chn>:MARKer<Mk>:FORMat]
*RST value 
SCPI, 
Command 
Types 
Device-specific, query only.  
Example: 
Suppose that the active setup contains an active trace no. 1.  
CALC:MARK:REF ON  
Endnote pdf metadata - add, remove, update PDF metadata in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# Developers to Read, Add, Edit, Update and Delete PDF Metadata
pdf xmp metadata editor; add metadata to pdf
Endnote pdf metadata - VB.NET PDF metadata library: add, remove, update PDF metadata in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Enable VB.NET Users to Read, Write, Edit, Delete and Update PDF Document Metadata
read pdf metadata online; read pdf metadata java
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
386
Create the reference marker and display it in the center of the sweep range.  
CALC:MARK:REF:Y?  
Query the measurement value at the reference marker position.  
CALCulate<Chn>:MARKer<Mk>SEARch:BFILter:RESult[:STATe] <Boolean> 
Shows or hides the bandfilter search results in the diagram area.   
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10. This numeric suffix is ignored and may be set to 
any value.   
<Boolean> 
ON - Show the bandfilter search results. If no bandfilter search has been initiated 
before (CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute BFILter), 
nothing is displayed. 
OFF - hide the bandfilter search results.   
*RST value 
OFF 
SCPI, 
Command 
Types 
Device-specific, command or query.  
Example: 
See CALCulate<Chn>:MARKer<Mk>:BWIDth. 
CALCulate<Chn>:MARKer<Mk>:SEARch[:IMMediate]  
Initiates a search according to the search function selected with 
CALCulate<Chn>:MARKer<Mk>:FUNCtion[:SELect]. The marker must be created before using 
CALCulate<Chn>:MARKer<Mk>[:STATe] ON.
Note: Together with CALCulate<Chn>:MARKer<Mk>:FUNCtion[:SELect] this command is the ZVR-
compatible equivalent of CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute ....
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10. For a bandfilter search (BFILter) this 
numeric suffix is ignored and may be set to any value because the bandfilter 
search functions always use markers Mkr1 to Mkr4.  
Range [def. 
unit] 
–[–]  
*RST value 
– 
SCPI, 
Command 
Types 
Device-specific, no query.  
CALCulate<Chn>:MARKer<Mk>:SEARch:LEFT  
Selects a search mode for marker no. <Mk> and initiates a search for the next valid peak to the left. The 
marker must be created before using CALCulate<Chn>:MARKer<Mk>[:STATe] ON.
C# Word - Footnote & Endnote Processing in C#.NET
C# Word - Footnote & Endnote Processing in C#.NET. Provide Variety of C# Methods to Process Footnote & Endnote in Word Document. Create Footnote & Endnote.
change pdf metadata; pdf metadata reader
C# Word - Word Create or Build in C#.NET
Create Word Document from Existing Files Using C#. Create Word From PDF. Create Word From PowerPoint. Footnote & Endnote Processing.
remove metadata from pdf online; pdf metadata viewer
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
387
Note: This command is the ZVR-compatible equivalent of 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute LPEak.
<Chn> 
Channel number used to identify the active trace.
<Mk> 
Marker number in the range 1 to 10.  
Range [def. unit] 
– [–]  
*RST value 
– 
SCPI, Command Types 
Device-specific, no query.  
CALCulate<Chn>:MARKer<Mk>:SEARch:NEXT  
Selects a search mode for marker no. <Mk> and initiates a search for the next highest or lowest value 
among the valid peaks. The marker must be created before using 
CALCulate<Chn>:MARKer<Mk>[:STATe] ON.
Note: This command is the ZVR-compatible equivalent of 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute NPEak.
<Chn> 
Channel number used to identify the active trace.
<Mk> 
Marker number in the range 1 to 10.  
Range [def. unit] 
– [–]  
*RST value 
– 
SCPI, Command Types 
Device-specific, no query.  
CALCulate<Chn>:MARKer<Mk>:SEARch:RIGHt  
Selects a search mode for marker no. <Mk> and initiates a search for the next valid peak to the right. The 
marker must be created before using CALCulate<Chn>:MARKer<Mk>[:STATe] ON.
Note: This command is the ZVR-compatible equivalent of 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute RPEak.
<Chn> 
Channel number used to identify the active trace.
<Mk> 
Marker number in the range 1 to 10.  
Range [def. unit] 
– [–]  
*RST value 
– 
SCPI, Command Types 
Device-specific, no query.  
CALCulate<Chn>:MARKer<Mk>:SEARch:TRACking <Boolean> 
Enables or disables the marker tracking mode for marker no. <Mk>. Tracking mode causes the active 
minimum/maximum or target search of the active marker to be repeated after each sweep. A marker must 
be created and a search mode must be active (CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute 
...) to use this command.   
If the current search mode is a bandfilter search this command enables or disables bandfilter tracking.  
<Chn> 
Channel number used to identify the active trace. 
C# Word - Convert Word to PDF in C#.NET
Word: Convert Word to PDF. C# Word - Convert Word to PDF in C#.NET. Online C# Tutorial for Converting Word to PDF (.pdf) Document. Word to PDF Conversion Overview
bulk edit pdf metadata; clean pdf metadata
C# Word - Insert Image to Word Page in C#.NET
Footnote & Endnote Processing. Table Row Processing. Table Cell Processing. Annotate Word. text in PDF, C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET
analyze pdf metadata; edit pdf metadata acrobat
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
388
<Mk> 
Marker number in the range 1 to 10. For a bandfilter search (BFILter) this 
numeric suffix is ignored and may be set to any value because the bandfilter 
search functions always use markers Mkr1 to Mkr4.  
<Boolean> 
ON | OFF - Enables or disables the marker tracking mode. 
*RST value 
OFF 
SCPI, 
Command 
Types 
Device-specific, command or query.  
Example: 
Suppose that the active setup contains an active trace no. 1.  
CALC:MARK ON; FUNC:EXEC MAXimum  
Create marker no. 1 and assign them to trace no. 1. Activate a maximum search 
for marker no. 1.  
CALC:MARK:SEAR:TRAC ON   
Enable the tracking mode for the created marker.  
CALCulate<Chn>:MARKer<Mk>[:STATe] <Boolean> 
Creates the marker numbered <Mk> and assigns it to trace no. <Chn>.   
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10. If unspecified the numeric suffix is set to 
1.  
<Boolean> 
ON | OFF - Creates or removes the marker.  
*RST value 
OFF 
SCPI, Command 
Types 
Device-specific, command or query.  
Example: 
Suppose that the active setup contains an active trace no. 1.  
CALC:MARK ON; MARK2 ON   
Create markers 1 and 2 and assign them to trace no. 1. The default position of both markers is 
the center of the sweep range.  
CALCulate<Chn>:MARKer<Mk>:TARget <numeric_value> 
Defines the target value for the target search of marker no. <Mk>, which can be activated using 
CALCulate<Chn>:MARKer<Mk>:FUCTion:EXECute TARGet.
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10.   
<numeric_value> 
Target search value of marker no. <Mk>.  
Range [def. unit] 
Depending on the format of the active trace (CALCulate<Chn>:FORMat). For 
adB Mag trace the range is –300 dB to +200 dB, the increment (UP. DOWN) 
is 0.1 dB. [dB, deg etc., depending on the trace format]   
*RST value 
Depending on the trace format; 0 dB for a dB Mag trace. 
How to C#: Generate Thumbnail for Word
Footnote & Endnote Processing. Table Row Processing. Table Cell Processing. Annotate Word. text in PDF, C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET
embed metadata in pdf; pdf keywords metadata
C# Word - Document Processing in C#.NET
Provide a Series of Methods to Setup Document Properties and Modify Document Content for Users.
remove pdf metadata; search pdf metadata
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
389
SCPI, Command 
Types 
Device-specific, command or query.  
Example: 
CALC:MARK ON  
Create marker no. 1 and display it in the center of the sweep range.  
:CALC:MARK:TARG -10; FUNC:EXEC TARG  
Define a target search value of –10 dB and start the target search.  
CALC:MARK:X? 
Query the stimulus value corresponding to the target search result.  
CALCulate<Chn>:MARKer<Mk>:TYPE NORMal | FIXed  
Sets marker no. <Mk> to normal or fixed mode. The marker must be created before using 
CALCulate<Chn>:MARKer<Mk>[:STATe] ON.
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10.  
Parameters 
NORMal – response value changes according to the measurement result. 
FIXed –  marker keeps its current response value.   
*RST value 
NORMal 
SCPI, Command 
Types 
Device-specific, command or query.  
Example: 
CALC:MARK ON; CALC:MARK:TYPE FIX  
Create marker 1and display it in the center of the sweep range as a fixed 
marker. 
CALC:MARK:X 1GHz  
Shift the marker horizontally. The response value remains fixed.  
CALCulate<Chn>:MARKer<Mk>:X <numeric_value> 
Defines the stimulus (in Cartesian diagrams: x-axis) value of the marker no. <Mk>, which can (but doesn't 
have to) be created using CALCulate<Chn>:MARKer<Mk>[:STATe] ON.
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10.   
<numeric_value> 
Stimulus value of marker no. <Mk>.  
Range [def. unit] 
–9.9E+11 Hz to +9.9E+11 Hz [Hz] (for frequency sweeps)  
*RST value 
0Hz  
SCPI, Command 
Types 
Device-specific, command or query.  
Example: 
Suppose that the active setup contains an active trace no. 1 and the sweep range for a 
frequency sweep starts at 1 GHz.  
CALC:MARK ON  
Create marker no. 1 and display it in the center of the sweep range.  
C# Word - Delete Word Document Page in C#.NET
Provides Users with Mature Document Manipulating Function for Deleting Word Pages.
remove metadata from pdf; batch pdf metadata
C# Word - Extract or Copy Pages from Word File in C#.NET
Footnote & Endnote Processing. Table Row Processing. Table Cell Processing. Annotate Word. text in PDF, C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET
adding metadata to pdf; online pdf metadata viewer
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
390
CALC:MARK:X 1GHz  
Set the marker to the beginning of the sweep range.  
CALCulate<Chn>:MARKer<Mk>:Y? 
Returns the response (in Cartesian diagrams: y-axis) value of marker no. <Mk>. The marker must be 
created before using CALCulate<Chn>:MARKer<Mk>[:STATe] ON.
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10.   
Response 
Response value of marker no. <Mk>.   
Range [def. unit] 
Depending on the measured quantity. [unit depending on the marker format; see 
CALCulate<Chn>:MARKer<Mk>:FORMat]
*RST value 
SCPI, 
Command 
Types 
Device-specific, query only.  
Example: 
Suppose that the active setup contains an active trace no. 1.  
CALC:MARK ON  
Create marker no. 1 and display it in the center of the sweep range.  
CALC:MARK:Y?  
Query the measurement value at the marker position.  
CALCulate<Chn>:MATH...     
This subsystem permits processing of measured data in numerical expression format. The operators are -, 
/and use of constants and data arrays are permitted. 
CALCulate<Chn>:MATH:FUNCtion NORMal | SUBTract | DIVide 
Defines a simple mathematical relation between the active trace and the active memory trace to calculate 
anew mathematical trace and displays the mathematical trace.  
This command places some restrictions on the mathematical expression and the operands. Use 
CALCulate<Chn>:MATH[:EXPRession]:SDEFine to define general expressions.  
<Chn> 
Channel number used to identify the active trace. If unspecified the numeric suffix 
is set to 1. 
NORMal 
SUBTract 
DIVide 
Math. trace = active data trace 
Math. trace = data – memory 
Math. trace = data / memory 
*RST value 
NORMal 
SCPI, 
Confirmed, with query.  
C# Word - Insert Blank Word Page in C#.NET
Guide C# Users to Insert (Empty) Word Page or Pages from a Supported File Format.
acrobat pdf additional metadata; read pdf metadata
C# Word - Word Creating in C#.NET
Tell Users How to Create New Word File and Load Word from Other Files.
get pdf metadata; adding metadata to pdf files
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
391
Command 
Types 
Example: 
*RST; CALC:MATH:MEM  
Copy the current state of the default trace Trc1 to a memory trace named 
'Mem2[Trc1]'. The memory trace is not displayed. 
CALC:MATH:FUNC DIV  
Define a mathematical trace, dividing the data trace by the stored memory trace. 
The mathematical trace is displayed instead of the active data trace. 
CALC:MATH:STAT?  
The response is 1 (mathematical mode switched on, mathematical trace 
displayed).   
CALCulate<Chn>:MATH:MEMorize  
Copies the current state of the active data trace to a memory trace. If a mathematical trace is active, the 
data trace associated with the mathematical trace is copied. The memory trace is named 
Mem<n>[<Data_Trace>] where <n> counts all data and memory traces in the active setup in chronological 
order, and <Data_Trace> is the name of the associated (copied) data trace.  
The exact function of the command depends on the number of memory traces associated with the active 
data trace: 
If no memory trace is associated to the active trace, a new memory trace is generated. 
If several memory traces are associated with the active trace, the current measurement data 
overwrites the last generated or changed memory trace.   
To copy a trace to the memory without overwriting an existing memory trace or define a memory trace 
name, use TRACe:COPY <memory_trc>,<data_trc>. To copy an active mathematical trace use 
TRACe:COPY:MATH <memory_trc>,<data_trc> 
<Chn> 
Channel number used to identify the active trace.   
*RST value 
SCPI, Command 
Types 
Device-specific, no query 
Example: 
*RST; CALC:MATH:MEM  
Copy the current state of the default trace Trc1 to a memory trace named 
'Mem2[Trc1]'. The memory trace is not displayed.  
DISP:WIND:TRAC2:FEED 'Mem2[Trc1]' 
Display the created memory trace in the active diagram area (diagram area no. 
1). 
CALCulate<Ch>:PARameter...     
This subsystem assigns names and measurement parameters to traces. The commands are device-
specific.  
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
392
CALCulate<Ch>:PARameter:CATalog? 
Returns the trace names and measurement parameters of all traces assigned to a particular channel.  
<Ch> 
Channel number. If unspecified the numeric suffix is set to 1.   
Response 
String parameter with comma-separated list of trace names and measurement 
parameters, e.g. 'CH4TR1,S11,CH4TR2,S12'. The measurement parameters are 
returned according to the naming convention of 
CALCulate<Ch>:PARameter:SDEFine. The order of traces in the list reflects their 
creation time: The oldest trace is the first, the newest trace is the last trace in the list.  
*RST value 
SCPI, 
Command 
Types 
Device-specific, query only.  
Example: 
CALC4:PAR:SDEF 'Ch4Tr1', 'S11'  
Create channel 4 and a trace named Ch4Tr1 to measure the input reflection 
coefficient S11.  
CALC4:PAR:CAT?  
Query the traces assigned to channel 4. If Ch4Tr1 is the only trace assigned to 
channel 4, the response is 'CH4TR1,S11'. 
CALCulate<Ch>:PARameter:DEFine '<string>', S11 | S12 | S21 | S22 
Creates a trace and assigns a channel number, a name and a measurement parameter to it. The trace is 
not displayed. To display a trace defined via CALCulate<Ch>:PARameter:DEFine, a window must be 
created (DISPlay:WINDow<Wnd>[:STATe] ON) and the trace must be assigned to this window 
(DISPlay:WINDow<Wnd>:TRACe:FEED); see example below. 
Traces must be selected to become active traces; see CALCulate:PARameter:SELect.
This command has been implemented for compatibility reasons. The parameter names in this 
command differ from ZVL conventions; moreover the parameter list is not complete. The 
alternative command CALCulate<Ch>:PARameter:SDEFine uses a complete parameter list with 
compatible names.  
<Ch> 
Channel number. <Ch> may be used to reference a previously defined channel. If 
<Ch> does not exist, it is generated with default channel settings.  
'<string>' 
Trace name, e.g. 'Trc4'. See Rules for trace names in the Trace Manager 
description.  
S11, S12, S21, 
S22 
Measurement parameter 
*RST value 
SCPI, 
Command 
Types 
Device-specific, no query. CALCulate<Ch>:PARameter:CATalog? returns a list 
of all defined traces.  
Example: 
CALC4:PAR:DEF 'Ch4Tr1', S11  
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
393
Create channel 4 and a trace named Ch4Tr1 to measure the input reflection 
coefficient S11.  
DISP:WIND:STAT ON  
Create diagram area no. 1.  
DISP:WIND:TRAC:FEED 'CH4TR1' 
Display the generated trace in diagram area no. 1. 
CALCulate<Ch>:PARameter:DELete '<string>' 
Deletes a trace with a specified trace name and channel.   
<Ch> 
Channel number.   
'<string>' 
Trace name, e.g. 'Trc4'. See Rules for trace names in the Trace Manager 
description.  
*RST value 
SCPI, Command 
Types 
Device-specific, no query.  
Example: 
CALC4:PAR:SDEF 'Ch4Tr1', 'S11'  
Create channel 4 and a trace named Ch4Tr1 to measure the input reflection 
coefficient S11.  
CALC4:PAR:CAT?  
Query the traces assigned to channel 4. If Ch4Tr1 is the only trace assigned to 
channel 4, the response is 'CH4TR1,S11'. 
CALC4:PAR:DEL 'CH4TR1' 
Delete the created trace. 
CALCulate<Ch>:PARameter:MEASure '<string>', 'S11' | 'Y-S11' | ... | 'Z-S11' 
Assigns a measurement parameter to an existing trace.  
Note: To create a new trace and at the same time assign the attributes, use 
CALCulate<Ch>:PARameter:SDEFine . To display the trace, create a window 
(DISPlay:WINDow<Wnd>[:STATe] ON) and assign the trace to this window 
(DISPlay:WINDow<Wnd>:TRACe:FEED); see example below. 
Traces must be selected to become active traces; see CALCulate:PARameter:SELect.
CALCulate<Ch>:PARameter:CATalog? returns a list of all defined traces. You can open the trace 
manager (DISPlay:MENU:KEY:EXECute 'Trace Manager') to obtain an overview of all channels 
and traces, including the traces that are not displayed.   
<Ch> 
Channel number of an existing channel containing the referenced trace.   
'<string>' 
Trace name, e.g. 'Trc4'. See Rules for trace names in the Trace Manager 
description.  
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
394
'S11', ...  
Measurement parameter (string variable); see list of in the 
CALCulate<Ch>:PARameter:SDEFine command description.  
*RST value 
SCPI, 
Command 
Types 
Device-specific, with query (see 'S11',... parameter description above).   
Example: 
CALC4:PAR:SDEF 'Ch4Tr1', 'S11'  
Create channel 4 and a trace named Ch4Tr1 to measure the input reflection 
coefficient S
11
.
CALC4:PAR:MEAS 'Ch4Tr1', 'S12'  
Change the measurement parameter of the trace and measure the transmission 
coefficient S
12
.
CALC4:PAR:MEAS? 'Ch4Tr1'  
Query the measured quantity. The response is 'S12'.  
CALCulate<Ch>:PARameter:SDEFine '<string>', 'S11' | ... | 'Y-S11' | ... | 'Z-S11' | ...  
Creates a trace and assigns a channel number, a name and a measurement parameter to it. The trace 
becomes the active trace in the channel but is not displayed.  
To display the trace defined via CALCulate<Ch>:PARameter:SDEFine, create a window 
(DISPlay:WINDow<Wnd>[:STATe] ON) and assign the trace to this window 
(DISPlay:WINDow<Wnd>:TRACe:FEED); see example below. 
CALCulate<Ch>:PARameter:MEASure changes the measurement parameter of an existing 
trace.  
To select an existing trace as the active trace, use CALCulate:PARameter:SELect. You can open the 
trace manager (DISPlay:MENU:KEY:EXECute 'Trace Manager') to obtain an overview of all 
channels and traces, including the traces that are not displayed.    
In FW versions <V1.90, traces created with CALCulate<Ch>:PARameter:SDEFine must be 
selected explicitly (CALCulate:PARameter:SELect) in order to become active traces.  
<Ch> 
Channel number. <Ch> may be used to reference a previously defined channel. If 
<Ch> does not exist, it is generated with default channel settings.  
'<string>' 
Trace name, e.g. 'Trc4'. See Rules for trace names in the Trace Manager 
description.  
'S11', ...  
Measurement parameter (string variable); see list of parameters below. 
*RST value 
SCPI, 
Command 
Types 
Device-specific, no query. CALCulate<Ch>:PARameter:MEASure? 
'<Trc_name>' queries the measurement parameter of the trace. 
CALCulate<Ch>:PARameter:CATalog? returns a list of all defined traces.  
Example: 
CALC4:PAR:SDEF 'Ch4Tr1', 'S11'  
Create channel 4 and a trace named Ch4Tr1 to measure the input reflection 
coefficient S11.  
DISP:WIND2:STAT ON  
Documents you may be interested
Documents you may be interested