download pdf c# : View pdf metadata SDK application project winforms html .net UWP ZVL_Operating_008_V3_205-part1092

R&S ZVL 
Preparing for Use 
Remote Control in a LAN 
Quick Start Guide 1303.6538.62 - 06
35
C
If the network does not support DHCP, or if the analyzer is set to use alternate 
TCP/IP configuration, the addresses must be set manually.   
By default, the analyzer is configured to use dynamic TCP/IP configuration and obtain 
all address information automatically. This means that it is safe to establish a physical 
connection to the LAN without any previous analyzer configuration.  
Address selection 
If your network does not support DHCP, or if you choose to disable dynamic TCP/IP 
configuration, you must assign valid address information before connecting the 
analyzer to the LAN. Contact your network administrator to obtain a valid IP address, 
because connection errors can affect the entire network. 
Manual TCP/IP configuration 
To disable dynamic TCP/IP configuration and enter the TCP/IP address information 
manually proceed as follows:  
1.  Obtain the IP address and subnet mask for the analyzer and the IP address for the 
local default gateway from your network administrator. If needed, also obtain the 
name of your DNS domain and the IP addresses of the DNS and WINS servers on 
your network.   
2.  Press the SETUP front panel key to the left of the analyzer's display.  
3.  In the softkey menu opened, press General Setup – Network Address– DHCP: Off.  
4.  Enter your IP-Address and Subnet Mask. 
To enter additional IP address information, you have to access the operating system of 
the R&S ZVL.  
1.  Access Windows XP using an external keyboard; see Accessing Window XP's 
Start Menu.  
2.  Open the Control Panel – Network Connections – Local Area Connection Status – 
Local Area Connection Properties – Internet Protocol (TCP/IP) Properties dialog 
and enter the complete address information, e.g.: 
View pdf metadata - add, remove, update PDF metadata in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# Developers to Read, Add, Edit, Update and Delete PDF Metadata
analyze pdf metadata; change pdf metadata
View pdf metadata - VB.NET PDF metadata library: add, remove, update PDF metadata in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Enable VB.NET Users to Read, Write, Edit, Delete and Update PDF Document Metadata
edit pdf metadata; clean pdf metadata
R&S ZVL 
Preparing for Use 
Remote Control in a LAN 
Quick Start Guide 1303.6538.62 - 06
36
For more information refer to the Windows XP Help.  
1.7.2  Remote Desktop Connection 
Remote Desktop is a Windows application which can be used to access and control 
the analyzer from a remote computer through a LAN connection. While the 
measurement is running, the analyzer screen contents are displayed on the remote 
computer, and Remote Desktop provides access to all of the applications, files, and 
network resources of the analyzer.  
To set up a Remote Desktop connection  
1.  Connect the analyzer to a LAN and determine its IP address; see Remote Control 
in a LAN. 
2.  Set up your remote computer (integrated in the LAN) to use Remote Desktop and 
create the Remote Desktop connection to the analyzer.  
For detailed information about Remote Desktop and the connection refer to the 
Windows XP Help.  
VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
View PDF in WPF. Annotate PDF in WPF. Export PDF in to PDF. Image: Remove Image from PDF Page. Image Link: Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete
pdf keywords metadata; remove metadata from pdf online
VB.NET PDF Library SDK to view, edit, convert, process PDF file
Offer professional PDF document metadata editing APIs, using which VB.NET developers can redact, delete, view and save PDF metadata. PDF Document Protection.
change pdf metadata creation date; modify pdf metadata
R&S ZVL 
Preparing for Use 
Windows XP 
Quick Start Guide 1303.6538.62 - 06
37
1.8  Windows XP 
The analyzer is equipped with a Windows XP operating system which has been 
configured according to the instrument's features and needs. Changes in the system 
configuration can be necessary in order to  
C
Establish a LAN connection  
C
Customize the properties of the external accessories connected to the analyzer  
C
Call up additional software tools  
Operating system settings 
The operating system is adapted to the network analyzer. To avoid impairment of 
instrument functions, only change the settings described in this manual. Existing 
software must be modified only with update software released by Rohde & Schwarz. 
Likewise, only programs authorized by Rohde & Schwarz for use on the instrument 
must be executed. 
The Start menu of the operating system is accessed as described below. All necessary 
settings can be accessed from the Start menu, in particular from the Control Panel.
1.8.1  Accessing Windows XP's Start Menu 
The Windows XP Start menu provides access to the Windows XP functionality and 
installed programs. From the Start menu, you can navigate to the submenus by using 
the mouse or the cursor keys of the keyboard.  
The simplest way to access the Start menu is by pressing SETUP – General Setup – 
More – Open Start Menu. This will not close the measurement application. 
If you find it more convenient, you can also use an external keyboard to access the 
Start menu,  
P
On your keyboard, press the Windows key or the CTRL+ESC key combination.  
To return to the measurement screen use one of the following methods: 
1.  Press the ALT+TAB key combination to switch to the analyzer application.  
2.  In the Windows task bar (opened via ALT + Tab), click the "R&S Analyzer Interface" 
icon. 
C# PDF Library SDK to view, edit, convert, process PDF file for C#
RasterEdge WPF PDF Viewer provides C# users abilities to view, annotate, convert and create PDF in WPF application. C#.NET: Edit PDF Metadata.
pdf xmp metadata editor; adding metadata to pdf
VB.NET PDF - View PDF with WPF PDF Viewer for VB.NET
View PDF in WPF. Annotate PDF in WPF. Export PDF in to PDF. Image: Remove Image from PDF Page. Image Link: Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete
rename pdf files from metadata; pdf metadata editor online
R&S ZVL 
Preparing for Use 
Firmware Update 
Quick Start Guide 1303.6538.62 - 06
38
1.9  Firmware Update 
Upgrade versions of the analyzer firmware are supplied as setup files (*msi). To 
perform a firmware update, you can either use the softkeys associated with the SETUP 
front panel key or the Instrument_Update_Tool. The latter procedure is recommended if 
installation via SETUP is not practicable.  
Setup files 
To prepare the installation, copy the setup file to any storage medium accessible from 
the analyzer. This may be the internal hard disk, an external storage medium (USB 
memory stick, CD-ROM with external drive) or a network connection (LAN, GPIB bus).
Calibration unit 
The Calibration Unit (accessory R&S ZV-Z5x) must be disconnected during a firmware 
update.  
To install new fimware using the SETUP menu, 
1.  Press SETUP > More > Firmware Update and open the Firmware Update dialog 
box.  
2.  Enter the update path of your firmware, depending on the installation medium that 
you use. You can also Browse… the update path in the dialog.  
3.  Click Execute to start the installation.  
The installation program will guide you through the installation. If installation fails, use 
the Instrument_Update_Tool as described below.  
Setup files can be stored and installed again. The default drive name of the USB 
interfaces is C:. External storage devices are automatically mapped to the next free 
drive, i.e. D:, E: etc.   
Remote control: SYST:FIRM:UPD 'D:\FW_UPDATE'
To install new fimware using the update tool, 
4.  Close all applications.  
5.  Access Window XP’s startup menu, e.g. by pressing SETUP – General Setup – 
More – Open Start Menu (see section Accessing Windows XP's Start Menu on p. 
37).  
6.  Select Programs > Accessories > Instrument_Update_Tool.  
7.  In the dialog box opened, select the ZVL.package file and click Open.  
8.  In the Install Manager dialog box opened, click Install.  
C# WPF PDF Viewer SDK to view PDF document in C#.NET
WPF Viewer & Editor. WPF: View PDF. WPF: Annotate PDF. WPF: Export PDF. Bookmark: Edit Bookmark. Metadata: Edit, Delete Metadata. Watermark: Add Watermark to PDF
pdf metadata viewer online; preview edit pdf metadata
How to C#: Modify Image Metadata (tag)
C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET VB.NET How-to, VB.NET PDF, VB.NET Word, VB VB.NET Barcode Read, VB.NET Barcode Generator, view less.
batch update pdf metadata; remove metadata from pdf
R&S ZVL 
Preparing for Use 
Firmware Update 
Quick Start Guide 1303.6538.62 - 06
39
1.9.1  Operation with and without Administrator Rights 
With firmware version V3.xx (image version 3.11) and higher, the network analyzer 
may be operated with or without administrator rights. Some administrative tasks (e.g. a 
firmware update) do require administrator rights; refer to the detailed description of the 
SETUP softkeys in chapter 4 of the operating manual.  
In the default configuration, auto login is enabled, and an account with administrator 
rights is active. This means that no password is required, and the full functionality of 
the analyzer is available to any user. An additional user account without administrator 
rights is pre-defined.  
To install new fimware using the update tool, 
To change the user account, access Windows XP's Start menu, e.g. by pressing 
SETUP – General Setup – More – Open Start Menu (see section Accessing Windows 
XP's Start Menu on p. 37) and click Settings – Control Panel – User Accounts. In the 
dialog opened, you can also change the passwords for the user accounts. User 
accounts with the following user names and passwords are pre-defined::  
Description 
User name 
Pasword 
Default account, with administrator rights  
Instrument 
894129 
Account without administrator rights 
NormalUser 
894129 
(De)activating auto login   
After being turned off, the R&S ZVB will return to the Instrument account without 
prompting for a password. To de-activate the automatic login mechanism,  
1.  Access the Start menu and select Run... 
2.  In the dialog box opened, enter C:\R_S\INSTR\USER\NO_AUTOLOGIN.REG and 
confirm.  
Auto login is deactivated. The next time you switch on the R&S ZVL, you will have to 
enter a user name and a password. Proceed in the same way, using the 
C:\R_S\INSTR\USER\AUTOLOGIN.REG file, to re-activate automatic login.  
Firmware upgrade and downgrade  
An update from a firmware version <V3.xx to version V3.xx or higher does not replace 
the image. To replace the image version, contact your R&S service representative. The 
image upgrade is possible on instruments with a DVI-D connector on the rear panel.  
Adowngrade of the firmware from V3.xx or higher to version <V3.xx requires the 
BackGrade program, which can be accessed from the Windows XP Start menu of the 
analyzer:  
1.  Access the Start menu.  
2.  Click Programs – Accessories – BackGrade and confirm with OK.  
3.  Perform the firmware update using the Instrument Update Tool described above.  
C# TIFF: TIFF Metadata Editor, How to Write & Read TIFF Metadata
C#.NET. Allow Users to Read and Edit Metadata Stored in Tiff Image in C#.NET Application. C# Overview - View and Edit TIFF Metadata.
read pdf metadata online; edit pdf metadata acrobat
VB.NET PDF File Compress Library: Compress reduce PDF size in vb.
Document and metadata. All object data. File attachment. Flatten visible layers. VB.NET Demo Code to Optimize An Exist PDF File in Visual C#.NET Project.
search pdf metadata; adding metadata to pdf files
R&S ZVL 
Preparing for Use 
Firmware Update 
Quick Start Guide 1303.6538.62 - 06
40
LXI  
The LXI functionality including the home page is unavailable while the instrument is 
operated without administrator rights.  
R&S ZVL 
Table of Contents 
Operating manual 1303.6538.62 - 05 
41 
Table of Contents 
2  Getting Started.................................................................................. 43 
2.1
Reflection Measurements.........................................................................................43
2.1.1
Instrument Setup for Reflection Measurements ..........................................................43
2.1.2
Parameter and Sweep Range Selection .....................................................................44
2.1.3
Instrument Calibration..................................................................................................45
2.1.4
Evaluation of Data........................................................................................................47
2.1.5
Saving and Printing Data.............................................................................................48
2.2
Transmission Measurements...................................................................................49
2.3
Basic Tasks................................................................................................................50
2.3.1
Control via Front Panel Keys.......................................................................................50
2.3.2
Data Entry....................................................................................................................52
2.3.3
Scaling Diagrams.........................................................................................................54
R&S
ZVL 
Getting Started 
Reflection Measurements 
Operating manual 1303.6538.62 - 05 
43 
2 Getting Started 
The following chapter presents a sample session with a R&S ZVL network analyzer 
and explains how to solve basic tasks that you will frequently encounter when working 
with the instrument.  
General safety instructions 
Before starting any measurement on your network analyzer, please note the 
instructions given in Chapter Preparing for Use.
In the System Overview you will find detailed information on customizing the 
instrument and the display according to your personal preferences. For a systematic 
explanation of all menus, functions and parameters and background information refer 
to the reference chapters in the online help system.  
Windows operation 
In the following we assume that you are familiar with standard Windows dialogs and 
mouse operation. Refer to sections Using Front Panel Keys and Data Entry to learn 
how to access instrument functions and control dialogs without a mouse and keyboard. 
2.1  Reflection Measurements     
In a reflection measurement, the analyzer transmits a stimulus signal to the input port 
of the device under test (DUT) and measures the reflected wave. A number of trace 
formats allow you to express and display the results. depending on what you want to 
learn from the data. Only one analyzer test port is required for reflection 
measurements.  
In the following example, the analyzer is set up for a reflection measurement, a 
frequency sweep range and measurement parameter is selected, the instrument is 
calibrated and the result is evaluated using various formats.   
2.1.1  Instrument Setup for Reflection Measurements 
In order to prepare a reflection measurement, you have to connect your DUT (which is 
assumed to have a male N 50  connector) to one of the (equivalent) analyzer test 
ports. Besides, it is recommended to preset the instrument in order to set it to a 
definite, known state.  
R&S
ZVL 
Getting Started 
Reflection Measurements 
Operating manual 1303.6538.62 - 05 
44 
1.  Proceed as described in section 
Starting the Analyzer and 
Shutting Down in Chapter 1 to 
switch on the instrument and 
start the NWA application. 
2.  Connect the input port of your 
DUT to test port 1 of the network 
analyzer.  
3.  Press the PRESET key in the 
upper left corner of the front 
panel to perform a factory preset 
of the analyzer.  
The analyzer is now set to its default 
state. The default measured quantity 
is the transmission S-parameter S
21
.
This quantity is zero in the current 
test setup, so the trace shows the 
noise level. 
2.1.2  Parameter and Sweep Range Selection 
After preset the display shows a diagram with a dB Mag scale. The sweep range (scale 
of the horizontal axis) is equal to the maximum frequency range of the analyzer, and 
the S-parameter S
12
is selected as a measurement parameter.  
To obtain information about the reflection characteristics of your DUT you have to 
select an appropriate measurement parameter and specify the sweep range.  
1.  Press the CENTER function key to the right of the display to open 
the associated numeric entry bar (Center Frequency). Enter the 
center of your desired frequency range in (e.g. 5.25 GHz). 
If you use the data keys at the front panel for data entry, simply type 5.25 
and terminate the entry with the G/n key. Refer to section Data Entry to 
learn more about entering numeric values and characters.  
2.  Press SPAN and enter the width of the frequency range you want to 
measure (e.g. 0.5 GHz). 
In addition to the linear frequency sweep considered in this example the 
analyzer provides frequency sweeps with a logarithmic or segmented 
frequency axis. Refer to Setting up a Sweep for more application 
examples.  
3.  Press MEAS and select the forward reflection coefficient S
11
as a 
measurement parameter. 
4.  Press SCALE and activate the Autoscale function. 
The analyzer adjusts the scale of the diagram to fit in the entire S
11
trace, 
Documents you may be interested