how to download pdf file in c# windows application : Remove metadata from pdf online control application platform web page azure .net web browser ZVL_Operating_008_V3_2055-part1098

R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
535
STATus:QUEStionable:PTRansition 
Sets the positive transition filter. Setting a bit causes a 0 to 1 transition in the corresponding bit of the 
associated condition register to cause a 1 to be written in the associated bit of the corresponding event 
register.  
<NRf> 
0to 65535 (decimal representation) 
*RST value 
–(see also Reset Values of the Status Reporting System) 
SCPI, Command Types 
Confirmed, command or query 
Example: 
STAT:QUES:PTR 1536  
Set bits no. 9 and 10 of the QUEStionable:PTRansition register
STATus:QUEStionable:LIMit<1|2>:CONDition? 
Returns the contents of the CONDition part of the QUEStionable:LIMit<1|2> register. Reading the 
CONDition registers is nondestructive.  
*RST value 
SCPI, Command 
Types 
Confirmed, query only 
Example: 
STAT:QUES:LIMit:COND?  
Query the CONDition part of the QUEStionable:LIMit1 register to retrieve the 
current status of the limit check. 
STATus:QUEStionable:LIMit<1|2>:ENABle 
Sets the enable mask which allows true conditions in the EVENt part of the QUEStionable:LIMit<1|2> 
register to be reported in the summary bit. If a bit is 1 in the enable register and its associated event bit 
transitions to true, a positive transition will occur in the summary bit (bit 10 of the QUEStionable register 
for the LIMit1 register, bit 0 of the LIMit1 register for the LIMit2 register).  
<NRf> 
0to 65535 (decimal representation) 
*RST value 
–(see also Reset Values of the status reporting system) 
SCPI, Command Types 
Confirmed, command or query 
Example: 
STAT:QUES:LIM2:ENAB 6  
Set bits no. 1 and 2 of the QUEStionable:LIMit2:ENABle register
STATus:QUEStionable:LIMit<1|2>[:EVENt]? 
Returns the contents of the EVENt part of the QUEStionable:LIMit<1|2> register. Reading an EVENt 
register clears it.  
Remove metadata from pdf online - add, remove, update PDF metadata in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# Developers to Read, Add, Edit, Update and Delete PDF Metadata
edit pdf metadata online; endnote pdf metadata
Remove metadata from pdf online - VB.NET PDF metadata library: add, remove, update PDF metadata in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Enable VB.NET Users to Read, Write, Edit, Delete and Update PDF Document Metadata
change pdf metadata; remove pdf metadata
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
536
*RST value 
SCPI, Command 
Types 
Confirmed, query only 
Example: 
STAT:QUES:LIM1?  
Query the EVENt part of the QUEStionable:LIMit1 register to check whether an 
event has occurred since the last reading. 
STATus:QUEStionable:LIMit<1|2>:NTRansition 
Sets the negative transition filter. Setting a bit causes a 1 to 0 transition in the corresponding bit of the 
associated condition register to cause a 1 to be written in the associated bit of the corresponding event 
register.  
<NRf> 
0to 65535 (decimal representation) 
*RST value 
–(see also Reset Values of the Status Reporting System) 
SCPI, Command Types 
Confirmed, command or query 
Example: 
STAT:QUES:LIM2:NTR 6  
Set bits no. 1 and 2 of the QUEStionable:LIMit2:NTRansition register
STATus:QUEStionable:LIMit<1|2>:PTRansition 
Sets the positive transition filter. Setting a bit causes a 0 to 1 transition in the corresponding bit of the 
associated condition register to cause a 1 to be written in the associated bit of the corresponding event 
register.  
<NRf> 
0to 65535 (decimal representation) 
*RST value 
–(see also Reset Values of the Status Reporting System) 
SCPI, Command Types 
Confirmed, command or query 
Example: 
STAT:QUES:LIM2:PTR 6 
Set bits no. 1 and 2 of the QUEStionable:LIMit2:PTRansition register
STATus:QUEue[:NEXT]? 
Queries and at the same time deletes the oldest entry in the error queue. Operation is identical to that of 
SYSTem:ERRor[:NEXT]?  
The entry consists of an error number and a short description of the error. Positive error numbers are 
instrument-dependent. Negative error numbers are reserved by the SCPI standard; see section Error 
Messages.  
*RST value 
SCPI, Command 
Confirmed, query only 
VB.NET PDF remove image library: remove, delete images from PDF in
Image: Insert Image to PDF. Image: Remove Image from PDF Page. Image Link: Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete Metadata. Form Process.
pdf metadata editor; pdf metadata
VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.
Ability to remove consecutive pages from PDF file in VB Enable specified pages deleting from PDF in Visual Basic Online source codes for quick evaluation in VB
read pdf metadata; pdf metadata extract
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
537
Types 
Example: 
STAT:QUE? 
Query the oldest entry in the error queue. 0,"No error" is returned if the error 
queue is empty. 
SYSTem...     
This subsystem collects the functions that are not related to instrument performance, such as function for 
general housekeeping and function related to global configurations.    
SYSTem:COMMunicate:AKAL:CONNection THRough | OPEN | SHORt | MATCh, 
<port_1>, <port_2> 
Connects the selected calibration standard to one or two ports of the active calibration unit (see 
SYSTem:COMMunicate:RDEVice:AKAL:ADDRess).   
THRough | OPEN | 
SHORt | MATCh 
Connected one or two-port standard  
<port_1> 
Port number of the calibration unit, for one and two-port 
standards 
<port_2> 
Second port number of the calibration unit, for two-port 
standards (THRough) only, omitted for the one-port standards  
*RST value 
–  
SCPI, Command 
Types 
Device-specific, command or query 
Example: 
SYST:COMM:AKAL:CONN THR, 1, 2  
Connect a trough standard between ports 1 and 2 of the cal 
unit.  
SYSTem:COMMunicate:AKAL:MMEMory[:STATe] <Boolean> 
Shows or hides the memory of the active calibration unit (see 
SYSTem:COMMunicate:RDEVice:AKAL:ADDRess).   
<Boolean> 
ON – memory is shown in a separate drive 
OFF – memory is not shown  
*RST value 
OFF  
SCPI, Command Types 
Device-specific, command or query 
Example: 
SYST:COMM:AKAL:MMEM ON  
Show the memory of the active calibration unit.  
C# PDF Page Delete Library: remove PDF pages in C#.net, ASP.NET
Free online C# class source code for deleting specified PDF pages in .NET console application. Able to remove a single page from PDF document.
embed metadata in pdf; remove metadata from pdf
C# PDF Password Library: add, remove, edit PDF file password in C#
Support to add password to PDF document online or in C# String outputFilePath = Program.RootPath + "\\" Remove.pdf"; // Remove password in the input file and
batch update pdf metadata; batch edit pdf metadata
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
538
SYSTem:COMMunicate:GPIB[:SELF]:ADDRess <address_no> 
Sets the GPIB address of the analyzer.  
<address_no> 
GPIB address (integer number)  
Range [def. unit] 
0to 30 [–].   
*RST value 
The GPIB address is factory-preset (value 20). *RST has no effect on the 
value.  
SCPI, Command 
Types 
Confirmed, command or query 
Example: 
SYST:COMM:GPIB:ADDR 10 
Set the GPIB address to 10. 
*RST; SYST:COMM:GPIB:ADDR?  
After a reset, the address is maintained (the response is 10). 
SYSTem:COMMunicate:GPIB[:SELF]:RTERminator LFEoi | EOI 
Sets the receive terminator of the analyzer. The receive terminator indicates the end of a command or a 
data block.  
The receive terminator setting is relevant if block data is transferred to the analyzer (FORMat[:DATA] 
REAL). In the default setting LFEOI, the analyzer recognizes an LF character sequence with or without the 
EOI control bus message as a receive terminator. An accidental LF in a data block can be recognized as a 
terminator and cause an interruption of the data transfer.  
The EOI setting is especially important if commands are transferred in block data format, because it 
ensures that the parser for command decoding is activated by the terminator only after the command has 
been completely transferred. Readout of binary data does not require a change of the receive terminator.   
LFEoi 
LF character sequence with or without EOI recognized 
EOI 
EOI recognized only 
*RST value 
LFEoi.  
SCPI, Command Types 
Device-specific, command or query 
Example: 
SYST:COMM:GPIB:RTER EOI 
Set the terminator to EOI. 
SYSTem:COMMunicate:PRINter:ENUMerate[:NEXT]? 
Queries the name of the next printer installed under Windows XP. 
The SYSTem:COMMunicate:PRINter:ENUMerate:FIRSt? command should be sent previously to 
return to the beginning of the printer list and query the name of the first printer. 
The names of other printers can then be queried with the 
SYSTem:COMMunicate:PRINter:ENUMerate[:NEXT]? command. After all available printer names 
have been output, an empty string enclosed by quotation marks (") is output for the next query. Further 
C# PDF remove image library: remove, delete images from PDF in C#.
Text in PDF. Image: Insert Image to PDF. Image: Remove Image from PDF Page. Cut Image in Page. Link: Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete
acrobat pdf additional metadata; pdf metadata reader
C# PDF bookmark Library: add, remove, update PDF bookmarks in C#.
Ability to remove and delete bookmark and outline from PDF document. Merge and split PDF file with bookmark. Save PDF file with bookmark open.
pdf keywords metadata; adding metadata to pdf
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
539
queries are answered by a query error. 
*RST value 
SCPI, Command Types 
Device-specific, query only 
Example: 
SYST:COMM:PRIN:ENUM:NEXT?
SYSTem:COMMunicate:PRINter:ENUMerate:FIRSt? 
Queries the name of the first printer (in the list of printers) available under Windows XP. The names of 
other installed printers can be queried with the 
SYSTem:COMMunicate:PRINter:ENUMerate[:NEXT]? command. 
If no printer is configured an empty string is output. 
*RST value 
SCPI, Command Types 
Device-specific, query only
Example: 
SYST:COMM:PRIN:ENUM:FIRS?
SYSTem:COMMunicate:PRINter:SELect <config> <printer name> 
Selects one of the printers configured under Windows XP including the associated output destination. 
The HCOPy:DESTination command is used to select an output medium other than the default one. 
<config> 
1| 2 - Printer configuration 1 or 2. If there is no suffix, configuration 1 is automatically 
selected. 
<printer 
name> 
Printer name as returned by the commands 
SYSTem:COMMunicate:PRINter:ENUMerate:FIRSt? or 
SYSTem:COMMunicate:PRINter:ENUMerate[:NEXT]? 
*RST value 
SCPI, 
Command 
Types 
Device-specific, command or query 
Example: 
SYST:COMM:PRIN:SEL LASER on LPT1 
Select printer LASER on LPT1. 
SYSTem:COMMunicate:RDEVice:AKAL:ADDRess '<cal_unit_name>'   
Selects one of the USB-connected calibration units for calibration (see commands 
SENSe<Ch>:CORRection:COLLect:AUTO...). This command is not necessary if only one cal unit is 
connected.  
<cal_unit_name> 
Name (USB address) of a connected calibration unit (string 
VB.NET PDF delete text library: delete, remove text from PDF file
to remove text format by modifying text font, size, color, etc. Other PDF edit functionalities, like add PDF text, add PDF text box and field. Online .NET
search pdf metadata; extract pdf metadata
VB.NET PDF Password Library: add, remove, edit PDF file password
Remove password from PDF. Dim outputFilePath As String = Program.RootPath + "\\" Remove.pdf" ' Remove password in the input file and output to a new file.
read pdf metadata java; modify pdf metadata
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
540
variable). The names of all connected cal units can be queried 
using SYSTem:COMMunicate:RDEVice:AKAL:ADDRess:ALL? 
*RST values 
'' (empty string; *RST has no effect on external devices).  
SCPI, Command 
Types 
Device-specific, command or query 
Example: 
SYST:COMM:RDEV:AKAL:ADDR:ALL?  
Query the names of all connected calibration units.  
SYST:COMM:RDEV:AKAL:ADDR 'ZV-Z52::1234'  
Select the cal unit named 'ZV-Z52::1234' for calibration.   
CORR:COLL:AUTO '', 1, 2, 4  
Perform an automatic 3-port TOSM calibration at test ports 1, 2, 
and 4 using the calibration unit's default calibration kit file and 
arbitrary test ports of the cal unit.  
SYSTem:COMMunicate:RDEVice:AKAL:ADDRess:ALL?   
Queries the names (USB addresses) of all connected calibration units.  
Response 
Names (USB addresses) of all connected calibration units (comma-
separated list of string variables).  
*RST values 
'' (empty string; *RST has no effect on external devices).  
SCPI, 
Command 
Types 
Device-specific, query only 
Example: 
See SYSTem:COMMunicate:RDEVice:AKAL:ADDRess  
SYSTem:DATA:SIZE ALL | AUTO 
Defines the block size for the data transfer between the instrument hardware and the software. The block 
size has an impact on the display of traces and on the readout of trace data using the commands of the 
TRACe... or CALCulate<Chn>:DATA... subsystems.  
ALL 
Data transfer with full buffer size. The data for each sweep are transferred together 
so that each displayed trace contains the data of exactly one sweep. The same is 
true for queried trace data. The trace is displayed or updated at once, the sweep 
progress is not visible on the screen.  
To make sure that all queried trace points stem from the same sweep you can 
also use single sweep mode (INITiate<Ch>:CONTinuous OFF) and the common 
command *OPC?  
AUTO 
Data transfer with an automatically determined block size. In general the data blocks 
comprise only part of a trace, therefore the sweep progress is visible on the screen. 
On the other hand the displayed trace can show the results of two consecutive 
sweeps.  
*RST value 
AUTO  
SCPI, 
Device-specific, command or query 
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
541
Command 
Types 
Example: 
SYST:DATA:SIZE ALL 
Select data transfer with full buffer size in order to view the trace data from a single 
sweep.. 
SYSTem:DATE <year>,<month>,<day> 
Sets the date for the internal calendar. 
<year>,<month>,<day> 
Date; the sequence of entry is year, month, day.
Range [def. unit] 
1980 to 2099, 1 to 12, 1 to 31. 
*RST value 
SCPI, Command Types 
Confirmed, command or query 
Example: 
SYST:DATE 2007,6,1 
SYSTem:DISPlay:COLor DBACkground | LBACkground | BWLStyles | BWSolid  
Selects the color scheme for all diagram areas in the active setup.   
DBACkground 
Dark background   
LBACkground 
Light background  
BWLStyles 
Black and white line styles  
BWSolid 
Black and white solid  
*RST value 
*RST does not affect the color settings; see also description of the Preset 
command.  
SCPI, Command 
Types 
Device-specific, command or query 
Example: 
SYST:DISP:COL LBAC 
Select a light background, e.g. to generate color hardcopies.  
SYSTem:DISPlay:FPANel <Boolean> 
Activates or deactivates the display of the front panel keys on the screen. With the display activated, the 
instrument can be operated on the screen using the mouse by pressing the corresponding buttons.  
<Boolean> 
ON | OFF – Activates or deactivates the display.
*RST value 
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
542
SCPI, Command Types 
Device-specific, command or query 
Example: 
SYST:DISP:FPAN ON 
Activates the display. 
SYSTem:DISPlay:UPDate <Boolean> | ONCE 
Switches the display on or off while the analyzer is in the remote state. The command has no effect while 
the analyzer is in the Local operating state.  
Switching off the display speeds up the measurement. This command may have an impact on the 
update of trace and channel settings; see SYSTem:SETTings:UPDate.
<Boolean> 
ON | OFF – Switch the display on or off. If the display is switched on, the analyzer 
shows the diagrams and traces like in manual control.   
ONCE 
Switch the display on and show the current trace. This parameter can be used for 
occasional checks of the measurement results or settings. The measurement is 
continued, however, the measurement results are not updated. Compared to the ON 
setting, ONCE does not slow down the measurement speed. 
*RST value 
OFF 
SCPI, 
Command 
Types 
Device-specific, command or query 
Example: 
SYST:DISP:UPD ON 
Switch the display on to view the traces and diagrams.  
SYSTem:ERRor[:NEXT]? 
Queries and at the same time deletes the oldest entry in the error queue. Operation is identical to that of 
STATus:QUEue[:NEXT]? 
The entry consists of an error number and a short description of the error. Positive error numbers are 
instrument-dependent. Negative error numbers are reserved by the SCPI standard; see section Error 
Messages. If the error queue is empty, the error number 0, "No error", is returned. 
*RST value 
SCPI, Command 
Types 
Confirmed, query only 
Example: 
SYST:ERR? 
Query the oldest entry in the error queue. 0,"No error" is returned if the error 
queue is empty. 
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
543
SYSTem:ERRor:ALL? 
Queries and at the same time deletes all entries in the error queue.  
The entries consist of an error number and a short description of the error. Positive error numbers are 
instrument-dependent. Negative error numbers are reserved by the SCPI standard; see section Error 
Messages.   
*RST value 
SCPI, Command 
Types 
Confirmed, command or query 
Example: 
SYST:ERR:ALL? 
Query all entries in the error queue. 0,"No error" is returned if the error 
queue is empty. 
SYSTem:ERRor:CLEar:ALL 
Deletes all entries in the table SYSTEM MESSAGES. 
*RST value 
SCPI, Command Types 
Device-specific, no query 
Example: 
SYST:ERR:CLE:ALL 
Delete all entries in the table.
SYSTem:ERRor:DISPlay <Boolean>  
Switches the display of a tooltip for remote command errors on or off. The tooltip appears at the bottom of 
the remote screen and of the manual screen; it is not displayed for SCPI errors no. –113, Undefined 
header. 
<Boolean> 
ON | OFF – Switch the tooltip on or off.    
*RST value 
OFF 
SCPI, Command Types 
Device-specific, command or query 
Example: 
SYST:ERR:DISP ON 
Switch the display of the tooltip for remote command errors on. 
FREQ:STAR 1 
SYSTem:ERRor:LIST? 
Reads all system messages and returns a list of comma separated strings. Each string corresponds to an 
R&S ZVL 
Command Reference 
Instrument-Control Commands 
Operating Manual 1303.6580.32-05 
544
entry in the table SYSTEM MESSAGES. If the error list is empty, an empty string "" will be returned.  
*RST value 
SCPI, Command Types 
Device-specific, query only 
Example: 
SYST:ERR:LIST? 
Read system messages and display them in a list.
SYSTem:FIRMware:UPDate '<file_name>' 
Installs a firmware version stored in a NWA setup file (*.msi) on the analyzer. The installation is automatic 
and does not require any further action to be taken.  
'<file_name>' 
String variable for the name and directory of a NWA setup file (*.msi).  
*RST value 
SCPI, Command 
Types 
Device-specific, no query 
Example: 
SYST:FIRM:UPD 'C:\Setup\ZVL_01.10.msi 
Install the firmware version 01.10 from the setup file stored in the Setup 
directoy of the analyzer's internal hard disk.   
SYSTem:FORMat:IDENt ZVL | LEGacy 
Adapts the return value of the *IDN? command to the R&S FSP/FSU/FSQ family. This function is 
intended for re–use of existing FSP/FSU/FSQ control programs together with the R&S ZVL.  
ZVL 
Switches the FSP adaptation off. Example *IDN? return string: 
'Rohde&Schwarz,ZVL-6,1303.6509K06/100007,1.10'.  
LEGacy 
Adapts the return value to the R&S FSP. Example *IDN? return string: 
'Rohde&Schwarz,ZVL-6,100007/006,1.10'.  
*RST value 
FSL 
SCPI, Command 
Types 
Device-specific, command or query 
Example: 
SYST:FORM:IDEN FSL 
Adapts the return value of *IDN? to the FSP. 
SYSTem:PASSword[:CENable] '<password>' 
Sends a password to the analyzer enabling a class of service functions to function (Command 
ENable). Service functions are activated with the commands of the DIAGnostic system and should be 
used by a R&S service representative only. Refer to the service manual for more information.   
'<password>' 
Case-sensitive string variable. Sending an invalid password generates error -
Documents you may be interested
Documents you may be interested