parse pdf c# : Edit pdf metadata online application Library tool html asp.net wpf online UMDigitizationSpecs201008272-part336

21
clearly should be reported to the Digital Conversion Unit and noted in the ―notes.txt‖ file to
insu
re that University evaluation of the vendor’s digital product takes this into account.
Evaluation of Image Skew 
All digital images must be deskewed to provide an easily read page image when presented on a 
display screen. Deskewing techniques and tools should be mindful both of the page edges and 
the page content. 
The University evaluates skew using a level horizontal rule across the image frame compared 
against lines of text on the page image, which are assumed to be level and square on the page. 
Deviations greater than 1 degree from the level rule are unacceptable.
Evaluation of Image Crop & Framing 
All digital images should fill the frame of the image to the largest extent possible. Text pages 
should be cropped to just within the page border, post-deskewing.  All 
black borders
where the 
image captures beyond the page itself should be eliminated from the final digital product. 
In the event where an illustration or marginalia goes out to the page edge(s), the vendor should 
consult with the University before performing any image cropping. 
VI. DATA DELIVERY REQUIREMENTS 
Shipping Requirements & Shipping Address
The digitization product must be shipped to the following address: 
Digital Conversion Unit 
University of Michigan 
3212 Buhr Bldg. 
837 Greene Street 
Ann Arbor, MI  48104-3213 
USA 
Delivery Format Options
The digital images files shall be delivered to the University in one of the following optional 
methods. In either case, the delivery medium must be formatted so that they can be accessed 
from a variety of computer platforms and operating systems. 
Portable USB Mass Storage Device 
This delivery format is the University’s preferred data delivery method. In order to utilize this
delivery method, the participating vendor must contact the University with an adequate amount 
of time to have a portable USB mass storage device made available for delivery and shipped to 
the vendor. 
The file organization structure specified in the Technical Requirements section must be 
maintained through the process of storing or moving the data to the mass storage device. The 
Edit pdf metadata online - add, remove, update PDF metadata in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# Developers to Read, Add, Edit, Update and Delete PDF Metadata
delete metadata from pdf; remove metadata from pdf file
Edit pdf metadata online - VB.NET PDF metadata library: add, remove, update PDF metadata in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Enable VB.NET Users to Read, Write, Edit, Delete and Update PDF Document Metadata
pdf xmp metadata viewer; read pdf metadata
22
USB mass storage device will be formatted using the FAT32 file system to maintain the highest 
possible degree of interoperability among computer systems and operating systems. The mass 
storage device and the file system may not be altered or reformatted without contacting the 
University ahead of time. 
It is strongly recommended after moving the digital image files onto the mass storage device that 
the MD5 checksums be verified to insure that all data has successfully migrated onto the mass 
storage device. 
Secure File Transfer Protocol (sFTP) 
This delivery format is an option available to all vendors who have a secure FTP site from which 
client files may be downloaded.  If a vendor has this option available, the University is willing to 
discuss this as a possible means of delivery. 
Optical Disc Format 
This delivery format is an option available to vendors who are unable to use the portable USB 
hard drive or sFTP delivery options. The file organization structure in the Technical 
Requirements section must be maintained through the process of burning the data to optical disc. 
The following media choices are both acceptable: 
· CD-R (Brand: MAM-A Gold CD-R) 
· DVD-R (Brand: MAM-A Gold Archival DVD-R)
For shipments of more than 6GB, DVD-Rs are highly preferred. Media may be mixed (e.g. both 
DVD-Rs and CD-Rs) in a single shipment. Media should be filled as close to maximal capacity 
as is possible within the file structure guidelines. CD-RW and DVD-RW are not acceptable 
media. 
All media must be written in close compliance to ISO-9660 in order facilitate use on the widest 
possible set of computing platforms and operating systems. Use of either UDF or Joliet 
extensions is not acceptable in the media format. All media must be written in a single session 
format only. Unreadable optical discs will be checked for ISO-9660 compliance with the 
CD/DVD Diagnostic software package from Infinadyne, Inc. 
All optical disc media must be labeled with the electronic label assigned by the University for 
that project and incrementing sequentially for each disc included in the delivery shipment. The 
University assigned disc label shall consist of a four-character prefix for the project, an 
underscore character, and three character enume
ration beginning with ―001‖ and incrementing 
one for each disc in the shipment. For example, for a shipment of three DVDs where the 
University assigned 
label prefix is ―PT08‖, they would be labeled electronically ―PT08_001,‖ 
―PT08_002,‖ and
―PT08_003‖ resp
ectively. For shipments where contone images are segregated 
from the bitonal images, separate media must be used for each type of image. Vendors who wish 
to provide data on optical disc should contact the University for clarification of this labeling 
process before burning the digitization process to disc. 
VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET edit PDF digital signatures, C#.NET edit PDF sticky note read barcodes from PDF, C#.NET OCR scan PDF.
preview edit pdf metadata; remove metadata from pdf acrobat
How to C#: Modify Image Metadata (tag)
C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET edit PDF digital signatures, C#.NET edit PDF sticky note read barcodes from PDF, C#.NET OCR scan PDF.
analyze pdf metadata; get pdf metadata
23
In addition, all media must be clearly labeled on the physical disc itself with the following 
information: 
·  CD/DVD Label assigned by University 
·  University Shipment Number 
·  Vendor Name 
·  Date of Disc Write 
VII. ERRORS IN DIGITIZED PRODUCT & REWORK 
The staff of the Digital Conversion Unit and DLPS will provide rigorous review, both automated 
and manual, to insure that the digital data product meets the specifications and requirements of 
that project. For the 
purposes of this document, an ―error‖ shall be defined as a digital product of
a project which does not meet the requirements of this document, ranging from a single image up 
to and including an entire shipment. 
Errors by Vendor
All errors made by the ve
ndor which are identified by the University’s quality control process
must be corrected by the vendor at no additional cost to the library. 
The University shall notify a vendor of all errors requiring rescanning or data correction 
immediately upon completion of quality control for that project. The vendor must then provide a 
timeframe for the correction and delivery of a new digital product. 
Where the vendor cannot meet quality standards or specification due to the condition of the 
University’s original m
aterials, the vendor should immediately contact the Digital Conversion
Unit for consultation and advice. This consultation must produce a clear direction for the vendor 
on how to proceed. 
Errors by University
There are a number of errors for which the University shall take responsibility and shall hold the 
vendor blameless: 
·  Misdesignation of project type, e.g. projects designated as MDP which should have been 
designated as BibID or vice versa are the responsibility of the University to correct; 
·  Failure to provide required targets for project type, e.g. projects designated as BibID projects 
which fail to include a bibliographic target and production note for each volume or 
bibliographic entity are the responsibility of the University to correct. Vendors encountering 
this problem must contact the University for advice before shipping the digital product back 
to the University; 
·  Failure to provide required identifier for an individual volume, e.g. project materials which 
do not have sufficient information by which to assign a proper identifier to the directory 
containing the page images. Vendors encountering this problem must contact the University 
for advice before shipping the digital product back to the University; 
·  Errors identified after digital product is accepted and physical materials returned to 
University. 
VB.NET PDF Library SDK to view, edit, convert, process PDF file
PDF Metadata Edit. Offer professional PDF document metadata editing APIs, using which VB.NET developers can redact, delete, view and save PDF metadata.
pdf xmp metadata editor; add metadata to pdf programmatically
C# HTML5 PDF Viewer SDK to create PDF document from other file
C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET edit PDF digital signatures, C#.NET edit PDF sticky note read barcodes from PDF, C#.NET OCR scan PDF.
remove pdf metadata online; pdf metadata reader
24
VIII. RETURN OF SCANNED MATERIALS 
Approval Required for Return of Materials
The Digital Conversion Unit must approve of the return of all scanned materials in writing via 
email, fax, or postal mail before materials are shipped. Materials may not be returned before the 
Library has received and approved the scanned data product. Shipments that are returned before 
approval is obtained from the Digital Conversion Unit may be subject to financial penalties if 
page images are unacceptable and require rescan. These penalties may accrue up to the entire 
scanning cost of the shipment if all images are unacceptable and the vendor has returned the 
materials before the images were approved. 
Shipments of materials must be returned complete and shipped complete on the same day; a 
shipment may not be broken up into separate shipments upon return of materials. Vendors are 
strongly encouraged to preserve and reuse undamaged packing boxes and padding materials used 
to ship 
the library materials to vendor’s facilities.
The vendor is expected to handle each volume with care, and to pack the returning volumes 
carefully to prevent further damage.  Shrink-wrapping each volume, or tying each volume with 
cotton bindery string, may prevent the volumes from moving around in the shipping boxes.  
Rubber bands are disallowed. 
Shipping Requirements & Shipping Address
The materials to be returned to the Library must be shipped to the following address: 
Digital Conversion Unit 
The University of Michigan 
3212 Buhr Building 
837 Greene Street 
Ann Arbor, Michigan 48104-3213
UPS Freight Collect Shipping will be required for return shipments of original University 
materials.  By using UPS, the University’s preferred shipper, we benefit from
deep price 
discounting including free inside delivery, as well as shipment and financial tracking in the 
University’s ―CampusShip‖ system.  
UPS Shipper No.
and Reference
information will be 
provided with the packing list for each shipment of Library materials sent to the vendor. 
If the vendor cannot ship materials to be returned via UPS, the vendor must use a shipper that 
will load and unload from a ground-level loading area at the Buhr Building. Loading areas at the 
Buhr Building will not accommodate semi-tractor trailer carriers or palletized loads. 
Timing of the Return of Library Materials
All library materials should be returned to the Digital Conversion Unit promptly upon the 
approval of the scanning data, but no later than five (5) business days after the scanning data 
approval is sent to the vendor. If the vendor prefers to only ship on certain days, that request may 
be approved to deviate from the aforementioned schedule if the Digital Conversion Unit is 
consulted in advance. 
C# TIFF: TIFF Metadata Editor, How to Write & Read TIFF Metadata
Tiff ›› C# Tiff: Edit Tiff Metadata. C# TIFF - Edit TIFF Metadata in C#.NET. Allow Users to Read and Edit Metadata Stored in Tiff Image in C#.NET Application.
pdf metadata; pdf remove metadata
VB.NET PDF - Create PDF Online with VB.NET HTML5 PDF Viewer
C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET edit PDF digital signatures, C#.NET edit PDF sticky note read barcodes from PDF, C#.NET OCR scan PDF.
acrobat pdf additional metadata; pdf metadata editor
25
The Digital Conversion Unit should be notified of the date of the return shipment and by which 
carrier it was shipped; provision of tracking number is also appreciated. 
IX. REVISION OF SPECIFICATIONS 
Revision of University Digitization Specifications
These digitization specifications are designed as a general reference document which binds all 
projects which are engaged with a vendor selected as preferred. However, the Library reserves 
the right to revise any area of these specifications at any time. The Library will report all formal 
changes immediately to all preferred vendors as edits or clarifications are made; and the vendor 
will have three months to conform to those changes or withdraw from its preferred vendor 
relationship with the Library from the time of notification. 
Input, questions, and comments from the vendors are invited on this specification document on 
an ongoing basis. In particular, any requirements or specifications that would be impossible for a 
selected vendor to meet should be addressed as soon as possible. Clarification or revision can be 
requested by participating vendors on any section; the University will attempt to address any and 
all concerns in a timely manner. 
Revision of University Technical Specifications
The technical imaging requirements of these digitization project specifications are undergoing 
constant refinement. Any number of cooperative projects at the Library may require a revision or 
alteration of these technical specifications as those projects progress. As the digitization needs of 
the University evolve or as individual projects demand, the University will modify these 
technical specifications where appropriate and possible for the purposes of this project. Any 
periodic modifications to the technical requirements after preferred vendors have been selected 
will be disseminated to all preferred vendors. 
X. SELECTION OF PREFERRED VENDORS 
Notification of Selection
All vendors submitting proposals in response to this RFP will be notified as to the final 
determination of their proposal within 30 days of that determination. 
Any vendor whose proposal is not accepted has the right to resubmit a revised proposal within 30 
days of receipt of notification for reconsideration. If the revised proposal is still determined to be 
unacceptable, then that vendor will be excluded from preferred vendor consideration until the 
next fiscal year. 
Vendors new to the university may be invited to submit a proposal for digitization services at any 
time; however, if their proposal is accepted, their preferred status will not go into effect until the 
next fiscal year. 
C# HTML5 PDF Viewer SDK to view, annotate, create and convert PDF
More details are given on this page. C#.NET: Edit PDF Password in ASP.NET. Users are able to set a password to PDF online directly in ASPX webpage.
pdf metadata editor online; add metadata to pdf
C# PDF Sticky Note Library: add, delete, update PDF note in C#.net
Allow users to add comments online in ASPX webpage. Able to change font size in PDF comment box. Able to save and print sticky notes in PDF file.
extract pdf metadata; view pdf metadata in explorer
26
Letter of Agreement
If selected as a preferred digitization vendor for the University, the vendor will be expected to 
sign a letter of agreement stipulating to these specifications as the governing requirements of all 
work and also stipulating to the accuracy of the cost detail quoted to the university in the 
vendor’s proposal.
Award of Projects to Preferred Vendors
Selection as a preferred vendor for the university does not guarantee that any percentage or 
number of projects will be awarded to any vendor selected as preferred. 
Projects will be awarded based on the University’s determination of what vendor best meets the
technical requirements of individual projects. Price and prior performance are criteria which 
influence the award of individual projects to a particular vendor. 
27
APPENDIX A:  CHECKLISTS FOR DIGITAL PRODUCT COMPLIANCE 
MDP Project Delivered on USB Mass Storage Device
Are all project directories and files stored in a top-level directory named for the University-
assigned shipment number? 
Are there an equal number of barcode subdirectories to volumes listed on the packing list? 
Are all volumes subdirectories named for the 14-digit barcode of the physical volume? 
 Is that barcode on the University supplied packing list? 
Is there one and only one image file for each page of each volume? 
Are all image files named with proper 8-digit file names? 
Do all image files have a proper file extension (either .tif or .jp2)? 
Does the sequence of image files for a volume start with 00000001 and increment sequentially 
for each thereafter? 
 Are there appropriate missing page targets in the sequence for volumes with missing 
pages? 
Are all bitonal images in TIFF format? 
 Are all bitonal TIFFs in CCITT Group 4 compression? 
 Do all bitonal TIFFs have the appropriate TIFF header tags with accurate information? 
Are all continuous tone images (color or grayscale) in JPEG 2000 format? 
 Do the files meet all of the technical requirements of the specifications for JPEG 2000? 
 Is there a UUID box in the JPEG 2000 header? Is there an XMP packet in that UUID 
box? 
Do all images meet the quality and technical parameters required? 
Is there a notes.txt file in each barcode subdirectory? 
Is there an aiim.tif image file in each barcode subdirectory? 
 Does the image file have a time and date stamp that indicates it was scanned along with 
the other images? 
MDP Project Delivered via Secure FTP
Are all project directories and files stored in a top-level directory named for the University-
assigned shipment number? 
Are there an equal number of barcode subdirectories to volumes listed on the packing list? 
28
Are all volumes subdirectories named for the 14-digit barcode of the physical volume? 
 Is that barcode on the University supplied packing list? 
Is there one and only one image file for each page of each volume? 
Are all image files named with proper 8-digit file names? 
Do all image files have a proper file extension (either .tif or .jp2)? 
Does the sequence of image files for a volume start with 00000001 and increment sequentially 
for each thereafter? 
 Are there appropriate missing page targets in the sequence for volumes with missing 
pages? 
Are all bitonal images in TIFF format? 
 Are all bitonal TIFFs in CCITT Group 4 compression? 
 Do all bitonal TIFFs have the appropriate TIFF header tags with accurate information? 
Are all continuous tone images (color or grayscale) in JPEG 2000 format? 
 Do the files meet all of the technical requirements of the specifications for JPEG 2000? 
 Is there a UUID box in the JPEG 2000 header? Is there an XMP packet in that UUID 
box? 
Do all images meet the quality and technical parameters required? 
Is there a notes.txt file in each barcode subdirectory? 
Is there an aiim.tif image file in each barcode subdirectory? 
 Does the image file have a time and date stamp that indicates it was scanned along with 
the other images? 
MDP Project Delivered on Optical Discs
Is the optical disc appropriate labeled both physically and electronically? 
 Does the physical label have the date the disc was burned and the University-assigned 
shipment number? 
 Does the disc report the same label as appears on the physical label? 
Is the optical disc in ISO-9660 format? 
Is the optical disc appropriate media for the data shipment size? 
Are all project directories and files stored in a top-level directory named for the University-
assigned shipment number? 
Are all of the second level directories named for the barcodes in that shipment? 
Are there an equal number of barcode subdirectories to volumes listed on the packing list? 
29
Are all volumes subdirectories named for the 14-digit barcode of the physical volume? 
 Is that barcode on the University supplied packing list? 
Is there one and only one image file for each page of each volume? 
Are all image files named with proper 8-digit file names? 
Do all image files have a proper file extension (either .tif or .jp2)? 
Does the sequence of image files for a volume start with 00000001 and increment sequentially 
for each thereafter? 
 Are there appropriate missing page targets in the sequence for volumes with missing 
pages? 
Are all bitonal images in TIFF format? 
 Are all bitonal TIFFs in CCITT Group 4 compression? 
 Do all bitonal TIFFs have the appropriate TIFF header tags with accurate information? 
Are all continuous tone images (color or grayscale) in JPEG 2000 format? 
 Do the files meet all of the technical requirements of the specifications for JPEG2000? 
 Is there a UUID box in the JPEG 2000 header? Is there an XMP packet in that UUID 
box? 
Do all images meet the quality and technical parameters required? 
Is there a notes.txt file in each barcode subdirectory? 
Is there an aiim.tif image file in each barcode subdirectory? 
 Does the image file have a time and date stamp that indicates it was scanned along with 
the other images? 
BibId Project Delivered on USB Mass Storage Device
Are all project directories and files stored in a top-level directory named for the University-
assigned shipment number? 
Are all subdirectories of the shipment directory named using the BibID indicated on the 
production note target? 
 Do all BibID directories have minimally one volume (four-digit) subdirectory? 
 Do all volume (four-digit) subdirectories have minimally one issue (three-digit) 
subdirectory? 
Is there one bitonal image file for each page of each volume? 
Are all bitonal image files named with proper 8-digit file names? 
Do all bitonal image files have a proper .tif file extension? 
30
Does the sequence of image files for a volume start with 00000001 and increment sequentially 
for each thereafter? 
 Are there appropriate missing page targets in the sequence for volumes with missing 
pages? 
Are all bitonal images in TIFF format? 
 Are all bitonal TIFFs in CCITT Group 4 compression? 
 Do all bitonal TIFFs have the appropriate TIFF header tags with accurate information? 
For volumes with contone images, is there a subdirectory of the issue (three-digit) subdirectory 
named ―pages‖?
Are all contone images in the ―pages‖ subdirectory?
 Are all contone image files named according to standard (with a leading 
―p‖
character 
and the same number as the corresponding bitonal page image)? 
Are all continuous tone images (color or grayscale) in JPEG 2000 format? 
 Do the files meet all of the technical requirements of the specifications for JPEG 2000? 
 Is there a UUID box in the JPEG 2000 header? Is there an XMP packet in that UUID 
box? 
Do all images meet the quality and technical parameters required? 
Is there a notes.txt file in each barcode subdirectory? 
Is there a prodnote.tif target image file in each subdirectory? 
Is there an aiim.tif image file in each barcode subdirectory? 
 Does the image file have a time and date stamp that indicates it was scanned along with 
the other images? 
BibID Project Delivered via Secure FTP
Are all project directories and files stored in a top-level directory named for the University-
assigned shipment number? 
Are there an equal number of barcode subdirectories to volumes listed on the packing list? 
Are all volumes subdirectories named for the 14-digit barcode of the physical volume? 
 Is that barcode on the University supplied packing list? 
Is there one and only one image file for each page of each volume? 
Are all image files named with proper 8-digit file names? 
Do all image files have a proper file extension (either .tif or .jp2)? 
Documents you may be interested
Documents you may be interested