c# pdf parser free : Remove pdf metadata SDK application project wpf azure asp.net UWP Xenon-UG10-part794

4 - 21
When the output sequence is Off, the bar code data is output to the host as the scanner decodes it.  Default = Off. 
Note: This selection is unavailable when the Multiple Symbols Selection is turned on.
Multiple Symbols
When this programming selection is turned On, it allows you to read multiple symbols with a single pull of the scanner’s trigger.  
If you press and hold the trigger, aiming the scanner at a series of symbols, it reads unique symbols once, beeping (if turned on) 
for each read.   If using a Granit scanner, the scanner also vibrates.  The scanner attempts to find and decode new symbols as 
long as the trigger is pulled.  When this programming selection is turned Off, the scanner will only read the symbol closest to the 
aiming beam.  Default = Off.
No Read
With No Read turned On, the scanner notifies you if a code cannot be read.  If using an EZConfig-Scanning Tool Scan Data 
Window (see page 11-3), an “NR” appears when a code cannot be read.  If No Read is turned Off, the “NR” will not appear.  
Default = Off.
If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” you can edit the output message (see Data 
Formatting beginning on page 7-1).  The hex code for the No Read symbol is 9C.  
Required
On/Not Required
*Off
On
* Off
On
* Off
Remove pdf metadata - add, remove, update PDF metadata in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# Developers to Read, Add, Edit, Update and Delete PDF Metadata
pdf metadata online; rename pdf files from metadata
Remove pdf metadata - VB.NET PDF metadata library: add, remove, update PDF metadata in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Enable VB.NET Users to Read, Write, Edit, Delete and Update PDF Document Metadata
pdf metadata viewer online; batch pdf metadata editor
4 - 22
Video Reverse
Video Reverse is used to allow the scanner to read bar codes that are inverted.  The Video Reverse Off bar code below is an 
example of this type of bar code.  Scan Video Reverse Only to read only inverted bar codes.  Scan Video Reverse and Stan-
dard Bar Codes to read both types of codes. 
Note: After scanning Video Reverse Only, menu bar codes cannot be read.  You must scan Video Reverse Off or Video 
Reverse and Standard Bar Codes in order to read menu bar codes.
Note: Images downloaded from the unit are not reversed.  This is a setting for decoding only.
Working Orientation
Some bar codes are direction-sensitive.  For example, KIX codes and OCR can misread when scanned sideways or upside 
down.  Use the working orientation settings if your direction-sensitive codes will not usually be presented upright to the scanner. 
Default = Upright. 
Video Reverse Only
Video Reverse and Standard Bar 
Codes
* Video Reverse Off
Upright:
Vertical, Top to Bottom:
(Rotate CW 90°)
Upside Down:
Vertical, Bottom to Top:
(Rotate CCW 90°)
VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.
Able to remove a single page from adobe PDF document in VB.NET. Ability to remove consecutive pages from PDF file in VB.NET. Enable
read pdf metadata java; batch edit pdf metadata
VB.NET PDF remove image library: remove, delete images from PDF in
Insert Image to PDF. Image: Remove Image from PDF Page. Image: Copy, Paste, Cut Image in Page. Link: Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete
pdf metadata viewer; c# read pdf metadata
4 - 23
* Upright
Vertical, Bottom to Top
Upside Down
Vertical, Top to Bottom
C# PDF Page Delete Library: remove PDF pages in C#.net, ASP.NET
console application. Able to remove a single page from PDF document. Ability to remove a range of pages from PDF file. Free trial package
pdf xmp metadata; acrobat pdf additional metadata
C# PDF Password Library: add, remove, edit PDF file password in C#
String outputFilePath = Program.RootPath + "\\" Remove.pdf"; // Remove password in the input file and output to a new file. int
pdf xmp metadata viewer; embed metadata in pdf
4 - 24
C# PDF bookmark Library: add, remove, update PDF bookmarks in C#.
Ability to remove and delete bookmark and outline from PDF document. Merge and split PDF file with bookmark. Save PDF file with bookmark open.
remove metadata from pdf file; edit pdf metadata online
C# PDF remove image library: remove, delete images from PDF in C#.
Insert Image to PDF. Image: Remove Image from PDF Page. Image: Copy, Paste, Cut Image in Page. Link: Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete
analyze pdf metadata; extract pdf metadata
5 - 1
5
Healthcare Settings
The following settings have been developed to enhance scanning in a healthcare environment.  These settings are only sup-
ported by the Xenon 1900h scanner and Xenon 1902h scanner and base.  They allow you to set quickly configure streaming 
presentation, and to set the scanner and base to quiet modes for scanning that does not disturb resting patients.
Quiet Operations - Combination Codes
The following combination codes program your Xenon healthcare scanner and base for silent or quiet settings using a single 
programming code.  If you wish to program some of these quiet settings individually, refer to Quiet Operations - LED and 
Volume Settings, beginning on page 5-3.
Silent Mode with Flashing LED
Scan the following bar code to completely silence the Xenon 1900h scanner or Xenon 1902h scanner and base.  The scan-
ner beep, base beep, base and scanner power up beep, and scanner linking sounds are all silenced.  When a bar code is 
scanned, the LED and aimer flash 5 times.  Green indicates a good scan, red indicates a bad scan.
Silent Mode with Long LED
Scan the following bar code to completely silence the Xenon 1900h scanner or Xenon 1902h scanner and base.  The scan-
ner beep, base beep, base and scanner power up beep, and scanner linking sounds are all silenced.  When a bar code is 
scanned, the LED and aimer remain solidly lit for 1 second.  Green indicates a good scan, red indicates a bad scan.
Silent Mode with Flashing LED - 
Cordless Scanner and Base
Silent Mode with Flashing LED - 
Corded Scanner
Silent Mode with Long LED - 
Cordless Scanner and Base
Silent Mode with Long LED - 
Corded Scanner
C# TIFF: TIFF Metadata Editor, How to Write & Read TIFF Metadata
You can also update, remove, and add metadata. List<EXIFField> exifMetadata = collection.ExifFields; You can also update, remove, and add metadata.
remove metadata from pdf; pdf xmp metadata editor
VB.NET PDF delete text library: delete, remove text from PDF file
projects. Basically, you can use robust APIs to select a PDF page, define the text character position, and remove it from PDF document.
adding metadata to pdf files; change pdf metadata creation date
5 - 2
Very Low Beeper (Nighttime Mode)
The following bar code silences the base, and sets the scanner for a very low beep when reading bar codes.  After scan-
ning this code, the base beep, base and scanner power up beep, and scanner linking sounds are all silenced.  When a bar 
code is scanned, the scanner emits a very soft beep. 
Low Beeper (Daytime Mode)
The following bar code sets all sounds to on, but at a low volume.  The scanner beep, base beep, base and scanner power 
up beep, and scanner linking sounds are all set to low volume. 
To reset your scanner and base to default sounds, refer to Resetting the Custom Defaults (page 12-3).
Page Button and Presentation Modes
Note: The following settings are not supported by the Xenon 1900h scanner.
Nighttime Mode - 
Cordless Scanner and Base
Nighttime Mode - 
Corded Scanner
Daytime Mode - 
Cordless Scanner and Base
Daytime Mode - 
Corded Scanner
5 - 3
When in Streaming Presentation Mode, the scanner’s aimer goes out after a short time, but the scan illumination remains on all 
the time to continuously search for bar codes (see Streaming Presentation™ Mode on page 4-10).  When in Temporary 
Streaming Presentation Mode, pressing the page button on the base puts the scanner into Streaming Presentation Mode until 
the timeout occurs.  If a bar code is scanned before the timeout is reached, the timer starts over. 
When the scanner is in the base, press the page button once to put the scanner into Temporary Streaming Presentation 
Mode.  When the scanner is in the base and the base has external power (plugged into an outlet), press the page button twice 
to put the scanner into Streaming Presentation Mode.  Press it twice again to end Streaming Presentation Mode.  When the 
base does not have external power, pressing the page button twice does not trigger Streaming Presentation Mode.
When the scanner is out of the base, the page button works normally.  Default = Temporary Streaming Presentation Mode On.
To remove Temporary Streaming Presentation Mode, scan the bar code for * Paging Mode On on page 3-7.
Temporary Streaming Presentation Timeout
Set a timeout for the length of time the illumination remains on and searching for bar codes when using Temporary Stream-
ing Presentation Mode.  Set the length for the timeout by scanning one of the bar codes below.  Default = 10,000 ms (10 
seconds).
Quiet Operations - LED and Volume Settings
If you have silenced or muted the scanner and base sounds, you may wish to adjust the visual (LED) indicators for Bluetooth 
linking sounds, scanning sounds, paging sounds, and out of range alarm sounds.
Linking LED Colors and Sound
Note: This setting is not supported by the Xenon 1900h scanner.
Under normal operations, the scanner chirps when linking to a base or an access point, and the LED on both the base and 
scanner flash green.  If you want to silence all sounds and set both devices to flash red LEDs to indicate the linking status, 
scan the Red LED Flashes/Silent bar code below.  The LEDS flash red while linking, then green to indicate the base and 
scanner are linked.  To return to the default LED colors and sound, scan Green LED Flashes/Sound.  Default = Green 
LED Flashes/Sound. 
* Temporary Streaming Presentation Mode On
*10 Second Timeout
60 Second Timeout
* Green LED Flashes/Sound
Red LED Flashes/Silent
5 - 4
Number of LED Flashes
If you have silenced the scanner’s beeper, you may set the number of times the LED flashes when reading bar codes.  
Default = 1 LED Flash.
Note: If you have set LED Solid (No Flash) (page 5-5), to anything but Off, that setting will override the LED Flash settings.  
In that case, scan the LED Solid Off bar code to turn off this feature, then scan the LED Flash code you wish to use.
LED Flash Rate
If you have silenced the scanner’s beeper, you may set the how quickly the LED flashes when reading bar codes.  Default = 
Fast Flash. 
* 1 LED Flash
5 LED Flashes
10 LED Flashes
25 LED Flashes
* Fast Flash
Medium Flash
Slow Flash
5 - 5
LED Solid (No Flash)
Under normal operations, the scanner’s LED flashes once for a good read.  You may set the LED to remain on for a length 
of time after a good read instead of flashing.   Default = LED Solid Off (Resume Flash).
If you have scanned a bar code and don’t want to wait for the LED to turn off, press the trigger a 2nd time and the LED turns 
off.  You can then scan the next bar code. 
Paging Volume Control
Note: This setting is not supported by the Xenon 1900h scanner.
When you press the Page button on the base or Access Point, the scanners associated with that base or Access Point will 
begin beeping in response.  If you pull the trigger on a scanner that is beeping in response, or press the Page button on the 
base or Access Point a second time, all associated scanners will stop beeping.  The following settings set the paging vol-
ume, independent of the volume used when scanning bar codes.  Default = Low.
* LED Solid Off 
(Resume Flash)
LED Solid 1 Second
LED Solid 3 Seconds
LED Solid 5 Seconds
Paging Volume Off
* Paging Volume Low
Paging Volume Medium
Paging Volume High
5 - 6
Out-of-Range Alarm Volume
Note: This setting is not supported by the Xenon 1900h scanner.
If your scanner is out range of the base, an alarm sounds from both your base and scanner.  If your scanner is out range of 
an Access Point, an alarm sounds from just the scanner. The alarm stops when the scanner is moved closer to the base or 
Access Point, when the base or Access Point connects to another scanner, or when the alarm duration expires (see Out-of-
Range Delay on page 5-6).  The following settings set the Out-of-Range Alarm for the base and the scanner, independent 
of the volume used when scanning bar codes.  Default = Base Alarm Volume Low, Scanner Alarm Volume Low.  
Out-of-Range Delay
Note: This setting is not supported by the Xenon 1900h scanner.
Base Alarm Volume 
Off
Scanner Alarm Volume 
Off
* Base Alarm Volume 
Low
* Scanner Alarm Volume 
Low
Base Alarm Volume 
Medium
Scanner Alarm Volume 
Medium
Base Alarm Volume
High
Scanner Alarm Volume 
High
Documents you may be interested