c# pdf parser free : Online pdf metadata viewer SDK control project winforms azure html UWP Xenon-UG18-part802

9 - 1
9
Imaging Commands
The scanner is like a digital camera in the way it captures, manipulates, and transfers images.  The following commands allow 
you to alter the way the scanner performs these functions.
Note: If you are using the scanner in a stand, you must set the In-Stand Sensor Mode to Off in order to take images (see In-
Stand Sensor Mode on page 4-9).
Single-Use Basis
Imaging Commands with their modifiers send instructions to the scanner on a single-use basis, and take effect for a single 
image capture.  Once that capture is complete, the scanner reverts to its imaging default settings.  If you want to permanently 
change a setting, you must use the serial default commands (see Chapter 12).  When the serial default command is used, that 
selection becomes the new, permanent setting for the scanner.
Command Syntax
Multiple modifiers and commands can be issued within one sequence.  If additional modifiers are to be applied to the same 
command, just add the modifiers to that command.  For example, to add 2 modifiers to the Image Snap command, such as set-
ting the Imaging Style to 1P and the Wait for Trigger to 1T, you would enter IMGSNP1P1T.  
Note: After processing an image capture command (IMGSNP or IMGBOX), you must follow it with an IMGSHP command if you 
want to see it on your terminal.
To add a command to a sequence, each new command is separated with a semicolon.  For example, to add the Image Ship 
command to the above sequence, you would enter IMGSNP1P1T;IMGSHP.  
The imaging commands are:
Image Snap - IMGSNP (page 9-1)
Image Ship - IMGSHP (page 9-3)
Intelligent Signature Capture - IMGBOX (page 9-10)
The modifiers for each of these commands follow the command description.
Note: The images included with each command description are examples only.  The results you achieve may be different from 
those included in this manual.  The quality of the output you receive will vary depending on lighting, quality of the initial 
image/object being captured, and distance of the scanner from the image/object.  To achieve a high quality image, it is 
recommended that you position your scanner 4-6" (10.2-15.2 cm) away from the image/object you are capturing.
Step 1 - Take a Picture Using IMGSNP
Image Snap - IMGSNP
An image is taken whenever the hardware button is pressed, or when the Image Snap (IMGSNP) command is processed.    
The image snap command has many different modifiers that can be used to change the look of the image in memory.  Any num-
ber of modifiers may be appended to the IMGSNP command.  For example, you can use the following command to snap an 
image, increase the gain, and have the beeper sound once the snap is complete:  IMGSNP2G1B
IMGSNP Modifiers
P - Imaging Style  
This sets the Image Snap style.  
0P Decoding Style.  This processing allows a few frames to be taken until the exposure parameters are met.  The last 
frame is then available for further use.
1P Photo Style  (default).  This mimics a simple digital camera, and results in a visually optimized image.
2P Manual Style.  This is an advanced style that should only be used by an experienced user.  It allows you the most 
freedom to set up the scanner, and has no auto-exposure.
B - Beeper
Causes a beep to sound after an image is snapped.
Online pdf metadata viewer - add, remove, update PDF metadata in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# Developers to Read, Add, Edit, Update and Delete PDF Metadata
pdf keywords metadata; remove metadata from pdf online
Online pdf metadata viewer - VB.NET PDF metadata library: add, remove, update PDF metadata in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Enable VB.NET Users to Read, Write, Edit, Delete and Update PDF Document Metadata
delete metadata from pdf; add metadata to pdf file
9 - 2
0B No beep (default)
1B Sounds a beep when the image is captured. 
T - Wait for Trigger
Waits for a hardware button push before taking the image.  This is only available when using Photo Style (1P).
0T Takes image immediately (default)
1T Waits for a button push, then takes the image
L - LED State
Determines if the LEDs should be on or off, and when.  Ambient illumination (0L) is preferred for taking pictures of color 
documents, such as ID cards, especially when the scanner is in a stand.  LED illumination (1L) is preferred when the scan-
ner is handheld.  LED State is not available when using Decoding Style  (0P).  
0L LEDs off (default)
1L LEDs on 
E - Exposure
Exposure is used in Manual Style only (2P), and allows you to set the exposure time.  This is similar to setting a shutter 
speed on a camera.  The exposure time determines how long the scanner takes to record an image.  On a bright day, expo-
sure times can be very short because plenty of light is available to help record an image. At nighttime, exposure time can 
increase dramatically due to the near absence of light.  Units are 127 microseconds.  (Default = 7874)   
nE Range: 1 - 7874
G - Gain
Gain is used in Manual Style only (2P).  Like a volume control, the gain modifier boosts the signal and multiplies the pixel 
value. As you increase the gain, the noise in an image is also amplified.
1G No gain (default)
2G Medium gain
4G Heavy gain
8G Maximum gain
Example of Exposure at 7874E with 
fluorescent lighting:
Example of Exposure at 100E with 
fluorescent lighting:
Example of Gain at 
1G:
Example of Gain at 
4G:
Example of Gain at 
8G:
VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET C#.NET read barcodes from PDF, C#.NET OCR scan PDF. C# ASP.NET Document Viewer, C# Online Dicom Viewer
adding metadata to pdf files; edit pdf metadata
C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
Create PDF Online. Convert PDF Online. WPF PDF Viewer. View Image to PDF. Image: Remove Image from PDF Page. Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete
pdf metadata; get pdf metadata
9 - 3
W - Target White Value
Sets the target for the median grayscale value in the captured image.  For capturing close-up images of high contrast doc-
uments, a lower setting, such as 75, is recommended.  Higher settings result in longer exposure times and brighter images, 
but if the setting is too high, the image may be overexposed.  Target White Value is only available when using Photo Style 
(1P).  (Default = 125)
nW Range: 0 - 255
D - Delta for Acceptance
This sets the allowable range for the white value setting (see W - Target White Value).  Delta is only available when using 
Photo Style (1P).  (Default = 25)
nD Range:  0 - 255
U - Update Tries
This sets the maximum number of frames the scanner should take to reach the D - Delta for Acceptance Update Tries is 
only available when using Photo Style (1P).  (Default = 6)
nU Range:  0 - 10
% - Target Set Point Percentage
Sets the target point for the light and dark values in the captured image.  A setting of 75% means 75% of the pixels are at or 
below the target white value, and 25% of the pixels are above the target white value.  Altering this setting from the default is 
not recommended under normal circumstances.  To alter grayscale values, W - Target White Value should be used. 
(Default = 50)
n% Range: 1 - 99
Step 2 - Ship a Picture Using IMGSHP
Image Ship - IMGSHP
An image is taken whenever the button is pressed, or when the Image Snap (IMGSNP) command is processed.  The last image 
is always stored in memory.  You can “ship” the image by using the IMGSHP command. 
The image ship commands have many different modifiers that can be used to change the look of the image output.  Modifiers 
affect the image that is transmitted, but do not affect the image in memory.  Any number of modifiers may be appended to the 
IMGSHP command.  For example, you can use the following command to snap and ship a bitmap image with gamma correction 
and document image filtering:  IMGSNP;IMGSHP8F75K26U 
Example of White 
Value at 75W:
Example of White 
Value at 125W:
Example of White 
Value at 200W:
Example of Target 
Set Point 
Percentage at 97%:
Example of Target 
Set Point 
Percentage at 40%:
Example of Target 
Set Point 
Percentage at 50%:
VB.NET PDF - WPF PDF Viewer for VB.NET Program
C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET C#.NET read barcodes from PDF, C#.NET OCR scan PDF. C# ASP.NET Document Viewer, C# Online Dicom Viewer
c# read pdf metadata; change pdf metadata creation date
VB.NET PDF - Create PDF Online with VB.NET HTML5 PDF Viewer
C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET C#.NET read barcodes from PDF, C#.NET OCR scan PDF. C# ASP.NET Document Viewer, C# Online Dicom Viewer
search pdf metadata; metadata in pdf documents
9 - 4
IMGSHP Modifiers
A - Infinity Filter
Enhances pictures taken from very long distances (greater than 10 feet or 3m).  The Infinity Filter should not be used with 
IMGSNP Modifiers (page 9-1).
0A Infinity filter off (default)
1A Infinity filter on
C - Compensation
Flattens the image to account for variations in illumination across the image.
0C Compensation disabled (default)
1C Compensation enabled
D - Pixel Depth
Indicates the number of bits per pixel in the transmitted image (KIM or BMP format only).
8D 8 bits per pixel, grayscale image (default)
1D 1 bit per pixel, black and white image
Example of Infinity Filter off (0A) 
from approximately 12 feet 
(3.66m) away:
Example of Infinity Filter on (1A)
from approximately 12 feet (3.66m) 
away:
Example of Compensation at 0C:
Example of Compensation at 1C:
C# HTML5 PDF Viewer SDK to create PDF document from other file
C#.NET edit PDF bookmark, C#.NET edit PDF metadata, C#.NET C#.NET read barcodes from PDF, C#.NET OCR scan PDF. C# ASP.NET Document Viewer, C# Online Dicom Viewer
pdf metadata editor online; read pdf metadata
C# HTML5 PDF Viewer SDK to view, annotate, create and convert PDF
This online HTML5 PDF document viewer library component offers reliable and excellent functionalities. C#.NET users and developers
bulk edit pdf metadata; batch update pdf metadata
9 - 5
E - Edge Sharpen
An edge sharpen filter cleans up the edges of an image, making it look cleaner and sharper.  While edge sharpening does 
make the image look cleaner, it also removes some fine detail from the original image.  The strength of the edge sharpen 
filter can be entered from 1 to 24.  Entering a 23E gives the sharpest edges, but also increases noise in the image.
0E Don’t sharpen image (default)
14E Apply edge sharpen for typical image
ne Apply edge sharpen using strength n (n = 1-24) 
F - File Format
Indicates the desired format for the image.  
0F KIM format 
1F TIFF binary
2F TIFF binary group 4, compressed
3F TIFF grayscale
4F Uncompressed binary (upper left to lower right, 1 pixel/bit, 0 padded end of line)
5F Uncompressed grayscale (upper left to lower right, bitmap format)
6F JPEG image (default)
8F BMP format (lower right to upper left, uncompressed)
10F TIFF color compressed image
11F TIFF color uncompressed image
12F JPEG color image
14F BMP color format
15F BMP Uncompressed raw image
H - Histogram Stretch
Increases the contrast of the transmitted image.  Not available with some image formats.  
0H No stretch  (default)
1H Histogram stretch
Example of Edge Sharpen at 0E:
Example of Edge Sharpen at 24E:
Example of Histogram Stretch at 0H: Example of Histogram Stretch at 1H:
C# WPF PDF Viewer SDK to view, annotate, convert and print PDF in
Create PDF Online. Convert PDF Online. WPF PDF Viewer. View Image to PDF. Image: Remove Image from PDF Page. Edit URL. Bookmark: Edit Bookmark. Metadata: Edit, Delete
google search pdf metadata; pdf metadata viewer online
VB.NET PDF Image Extract Library: Select, copy, paste PDF images
zonal information, metadata, and so on. Extract image from PDF free in .NET framework application with trial SDK components for .NET. Online source codes for
pdf metadata online; extract pdf metadata
9 - 6
I - Invert Image
Invert image is used to rotate the image around the X or Y axis.  
1ix Invert around the X axis (flips picture upside down)
1iy Invert around the Y axis (flips picture left to right)
IF- Noise Reduction
Used to reduce the salt and pepper noise in an image.
0if No salt and pepper noise reduction (default)
1if Salt and pepper noise reduction
Example of image 
with Invert Image set to 
1ix:
Example of image not 
inverted:
Example of image 
with Invert Image set 
to 1iy:
Example of Noise Reduction On (1if):
Example of Noise Reduction Off (0if):
9 - 7
IR - Image Rotate  
0ir Image as snapped (rightside up) (default)
1ir Rotate image 90 degrees to the right
2ir Rotate image 180 degrees (upside down)
3ir Rotate image 90 degrees to the left
J - JPEG Image Quality
Sets the desired quality when the JPEG image format is selected.  Higher numbers result in higher quality, but larger files.  
Smaller numbers result in greater amounts of lossy compression, faster transmission times, lower quality, but smaller files.  
(Default =  50)
nJ  Image is compressed as much as possible while preserving quality factor of n (n = 0 - 100)
0J worst quality (smallest file)
100Jbest quality (largest file)
K - Gamma Correction
Gamma measures the brightness of midtone values produced by the image.  You can brighten or darken an image using 
gamma correction.  A higher gamma correction yields an overall brighter image.  The lower the setting, the darker the 
image.  The optimal setting for text images is 50K. 
0K Gamma correction off (default)
50K Apply gamma correction for brightening typical document image
nK Apply gamma correction factor n (n = 0-1,000)
L, R, T, B, M - Image Cropping
Ships a window of the image by specifying the left, right, top, and bottom pixel coordinates.  Device columns are numbered 
0 through 1279, and device rows are numbered 0 through 959.
Example of Image Rotate set to  0ir:
Example of Image Rotate set to  2ir:
Example of Image Rotate set to  1ir:
Example of Image Rotate set to  3ir:
Example of Gamma 
Correction set to 50K:
Example of Gamma 
Correction set to 0K:
Example of Gamma 
Correction set to 255K:
9 - 8
nL The left edge of the shipped image corresponds to column n of the image in memory.  Range: 000 - 843.  (Default 
=  0)
nR The right edge of the shipped image corresponds to column n - 1 of the image in memory.  Range: 000 - 843.  
(Default =  all columns)
nT The top edge of the shipped image corresponds to row n of the image in memory.  Range: 000 - 639.  (Default =  0)
nB The bottom edge of the shipped image corresponds to row n - 1 of the image in memory.  Range: 000 - 639.  
(Default =  all rows)
Alternately, specify the number of pixels to cut from the outside margin of the image; thus only the center pixels are trans-
mitted.
nM Margin:  cut n columns from the left, n + 1 columns from the right, n rows from the top, and n + 1 rows from the 
bottom of the image.  Ship the remaining center pixels.  Range:  0 - 238.  
(Default =  0, or full image)
P - Protocol
Used for shipping an image.  Protocol covers two features of the image data being sent to the host.  It addresses the proto-
col used to send the data (Hmodem, which is an Xmodem 1K variant that has additional header information), and the for-
mat of the image data that is sent.
0P None (raw data) 
2P None (default for USB)
3P Hmodem compressed (default for RS232)
4P Hmodem
S - Pixel Ship
Pixel Ship sizes an image in proportion to its original size.  It decimates the image by shipping only certain, regularly 
spaced pixels.  For example, 4S would transmit every fourth pixel from every fourth line.  The smaller number of pixels 
shipped, the smaller the image, however, after a certain point the image becomes unusable. 
1S ship every pixel  (default)
2S ship every 2nd pixel, both horizontally and vertically
Example of Image 
Crop set to 300L:
Example of Image Crop 
set to 300R:
Uncropped Image:
Example of Image Crop set to 200T:
Example of Image Crop set to 200B:
Example of Image Crop set to 238M:
9 - 9
3S ship every 3rd pixel, both horizontally and vertically
U - Document Image Filter
Allows you to input parameters to sharpen the edges and smooth the area between the edges of text in an image.  This fil-
ter should be used with gamma correction (see page 9-7), with the scanner in a stand, and the image captured using the 
command:
IMGSNP1P0L168W90%32D
This filter typically provides better JPEG compression than the standard E - Edge Sharpen command (see page 9-9).  This 
filter also works well when shipping pure black and white images (1 bit per pixel).  The optimal setting is 26U.
0U Document image filter off (default)
26UApply document image filter for typical document image
nU Apply document image filter using grayscale threshold n.  Use lower numbers when the image contrast is lower.  
1U will have a similar effect to setting E - Edge Sharpen (page 9-5) to 22e.  Range:  0-255.
V - Blur Image
Smooths transitions by averaging the pixels next to the hard edges of defined lines and shaded areas in an image.    
0V Don’t blur (default)
1V Blur
W - Histogram Ship
A histogram gives a quick picture of the tonal range of an image, or key type.  A low-key image has detail concentrated in 
the shadows; a high-key image has detail concentrated in the highlights; and an average-key image has detail concentrated 
in the midtones.  This modifier ships the histogram for an image.
0W Don’t ship histogram (default)
Example of Pixel Ship set to 1S:
Example of Pixel 
Ship set to 2S:
Example of Pixel 
Ship set to 3S:
Example of Document 
Image Filter set to 0U:
Example of Document 
Image Filter set to 26U:
Example of Blur Image Off (0V):
Example of Blur Image On (1V):
9 - 10
1W Ship histogram
Image Size Compatibility
If you have applications that expect an image ship to return exactly 640x480 pixels, scan the Force VGA Resolution bar 
code.  Default = Native Resolution.
Intelligent Signature Capture - IMGBOX
IMGBOX allows you to configure the size and location of a signature capture area relative to its proximity to a bar code.  This 
allows you to tailor a signature capture area to a specific form.  In order to use IMGBOX, you need a set form where the signa-
ture box location is in a known location relative to a bar code.  You can input the overall size of the signature area, as well as 
specify how far the signature area is from the bar code, vertically and horizontally.  You can also set the resolution and file format 
for the final output of the signature capture image.
Note: IMGBOX commands can only be triggered by one of the following types of bar codes: PDF417, Code 39, Code 128, Aztec, 
Codabar, and Interleaved 2 of 5.  Once one of these symbologies has been read, the image is retained for a possible 
IMGBOX command.
Signature Capture Optimize
If you will be using your scanner to capture signatures frequently, you should optimize it for this purpose.  However, the 
speed of scanning bar codes may be slowed when this mode is enabled.  Default = Off.
Image used for histogram:
Histogram of image at left:
Force VGA Resolution
*  Native Resolution
Optimize On
* Optimize  Off