3 - 9
The number of beeps and LED flashes emitted by the CCB01-010BT base for an error condition can be programmed from 
1 - 9.  For example, if you program this option to have five error beeps, there will be five error beeps and five LED flashes in 
response to an error.  To change the number of error beeps, scan the bar code below and then scan a digit (1-9) bar code 
and the Save bar code on the Programming Chart inside the back cover of this manual.  Default = 1.
Scanner Report
Scan the bar code below to generate a report for the connected scanners.  The report indicates the port, work group, scanner 
name, and address.  To assign a name to your scanner, refer to Menu Command Syntax, page 12-1.
Scanner Address
Scan the bar code below to determine the address of the scanner you are using.
Base or Access Point Address
Scan the bar code below to determine the address of the base or Access Point you are using.
Scanner Modes
Your scanner is capable of working in single scanner mode, multiple scanner mode, or with Bluetooth devices other than the 
charge base or Access Point.
Charge Only Mode
There may be times when you want to charge your scanner, but not link to the base.  For example, if a scanner is linked to 
an Access Point or other Bluetooth device and you need to charge the scanner, but want to retain your existing link.  
In order to program the base for Charge Only Mode, you must link a scanner to it.  Once the scanner is linked to the base, 
scan the Charge Only Mode bar code.  Any subsequent scanners placed in that base will charge without linking to it.  The 
scanner used to program the base remains linked to the base.  To unlink this scanner, scan Unlink Scanneron page 3-10. 
Note: When in Charge Only Mode, the scanner periodically wakes up and beeps.  See "Power Up Beeper"on page 4-1 to 
change this setting.
Number of Base Error Beeps/LED Flashes
Scanner Report
Scanner Address
Base Address
Charge Only Mode
Pdf xmp metadata editor - add, remove, update PDF metadata in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# Developers to Read, Add, Edit, Update and Delete PDF Metadata
pdf metadata viewer; remove pdf metadata online
Pdf xmp metadata editor - VB.NET PDF metadata library: add, remove, update PDF metadata in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Enable VB.NET Users to Read, Write, Edit, Delete and Update PDF Document Metadata
read pdf metadata; change pdf metadata creation date
3 - 10
If you want to charge a scanner and link to the base, use Charge and Link Mode.  If the base is programmed for Charge 
Only Mode, you must link a scanner to it first in order to program it for Charge and Link Mode.  Scan the linking bar code on 
the base to link the scanner, then scan Charge and Link Mode.  Default = Charge and Link Mode. 
Linked Modes
Locked Link Mode and Open Link Mode are the link modes that accommodate different applications.  Scan the appropriate 
bar codes included in the Open Link and Locked Link Mode explanations that follow to switch from one mode to another.  
Default = Open Link Mode.
Locked Link Mode - Single Scanner
If you link a scanner to a base or an Access Point using the Locked Link Mode, other scanners are blocked from being 
linked if they are inadvertently placed into the base, or if the Access Point linking bar code is scanned.  If you do place 
a different scanner into a base, it will charge the scanner, but the scanner will not be linked. 
To use a different scanner, you need to unlink the original scanner by scanning the Unlink Scanner bar code. (See 
Scanner Modes,page 3-9.)
Open Link Mode - Single Scanner
When newly shipped or defaulted to factory settings, a scanner is not linked to a base or an Access Point.  A link is 
established when the scanner is placed into a base, or an Access Point linking bar code is scanned.  When in Open 
Link Mode, a new link is established when a new scanner is placed in the base, or you scan an Access Point linking bar 
code.  Each time a scanner is placed into a base or scans an Access Point linking bar code, the scanner becomes 
linked to the base or Access point and the old scanner is unlinked.
Unlinking the Scanner
If a base or an Access Point has a scanner linked to it, that scanner must be unlinked before a new scanner can be linked.  
Once the previous scanner is unlinked, it will no longer communicate with the base or Access Point.  To unlink the scanner from 
a base or an Access Point, scan the Unlink Scanner bar code below.
* Charge and Link Mode
Locked Link Mode
(Single Scanner)
* Open Link Mode
(Single Scanner)
Unlink Scanner
C# TIFF: TIFF Metadata Editor, How to Write & Read TIFF Metadata
How to Get TIFF XMP Metadata in C#.NET. Use this C# sample code to get Tiff image Xmp metadata for string. // Load your target Tiff docuemnt.
pdf metadata reader; view pdf metadata
XDoc.Tiff for .NET, Comprehensive .NET Tiff Imaging Features
types, including EXIF tags, IIM (IPTC), XMP data, and to read, write, delete, and update Tiff file metadata. Render and output text to text, PDF, or Word file.
read pdf metadata online; get pdf metadata
3 - 11
Override Locked Scanner
If you need to replace a broken or lost scanner that is linked to a base or an Access Point, scan the Override Locked 
Scanner bar code below with a new scanner and place that scanner in the base, or scan the Access Point linking bar code.  
The locked link will be overridden; the broken or lost scanner’s link with the base or Access Point will be removed, and the 
new scanner will be linked.
Out-of-Range Alarm
If your scanner is out range of the base, an alarm sounds from both your base and scanner.  If your scanner is out range of an 
Access Point, an alarm sounds from just the scanner.  The alarm stops when the scanner is moved closer to the base or Access 
Point, when the base or Access Point connects to another scanner, or when the alarm duration expires.  To activate the alarm 
options for the scanner or the base and to set the alarm duration, scan the appropriate bar code below and then set the time-out 
duration (from 0-3000 seconds) by scanning digits on the Programming Chart inside the back cover, then scanning Save.  
Default = 0 sec (no alarm).
Note: If you are out of range when you scan a bar code, you will receive an error tone even if you do not have the alarm set.  
You receive the error tone since the data could not be communicated to the base or Access Point or the host.
Alarm Sound Type
You may change the alarm type for the scanner or a CCB01-010BT base by scanning the appropriate bar code below and 
then scanning a digit (0-7) bar code and the Save bar code on the Programming Chart inside the back cover of this manual.  
Default = 0.  
The sounds are as follows:
Note: The Access Point does not have a base alarm.
Setting
Sound
0
3 long beeps, medium pitch
1
3 long beeps, high pitch
2
4 short beeps, medium pitch
3
4 short beeps, high pitch
4
single chirps, medium pitch
5
2 chirps, then 1 chirp, medium pitch
6
single chirps, high pitch
7
2 chirps, then 1 chirp, high pitch
Override Locked Scanner
(Single Scanner)
Base Alarm Duration
Scanner Alarm Duration
C# Raster - Raster Conversion & Rendering in C#.NET
RasterEdge XImage.Raster conversion toolkit for C#.NET supports image conversion between various images, like Jpeg, Png, Bmp, Xmp and Gif, .NET Graphics
edit pdf metadata online; bulk edit pdf metadata
C# Raster - Image Process in C#.NET
Image Access and Modify. Image Information. Metadata(tag) Edit. Color VB.NET How-to, VB.NET PDF, VB.NET Word process various images, like Jpeg, Png, Bmp, Xmp
modify pdf metadata; rename pdf files from metadata
3 - 12
Scanner Power Time-Out Timer
Note: Scanner Power Time-out Timer only applies to cordless systems.  It does not apply to corded scanners.
When there is no activity within a specified time period, the scanner enters low power mode.  Scan the appropriate scanner 
power time-out bar code to change the time-out duration (in seconds).
Note:  Scanning zero (0) is the equivalent of setting no time-out.
If there are no trigger pulls during the timer interval, the scanner goes into power down mode.  Whenever the trigger is enabled, 
the timer is reset.  If the scanner is placed in the charge base cradle and the battery is in the process of being charged, the 
scanner will not go into power down mode.  Default = 3600 seconds.
Note: When the scanner is in power down mode, pull the trigger to power the unit back up.  There will be a set of power up beeps 
and a delay of up to a few seconds for the radio to join.  The scanner will then be ready to use.
Note: Only the CCB01-010BT base has an alarm. 
Base Alarm Type
Scanner Alarm Type
0 seconds
200 seconds
400 seconds
900 seconds
* 3600 seconds
7200 seconds
3 - 13
Flexible Power Management
If you are experiencing network performance issues, and suspect the scanner is interfering with other devices, you can turn 
down the power output of the scanner.  This reduces the range between the scanner and a base or an Access Point as shown 
in the following illustration:
Scan one of the bar codes below to set the scanner’s power output to Full Power (100%), Medium Power (35%), Medium Low 
Power (5%), or Low Power (1%).   Default = Full Power.
Note: Setting a Granit scanner to anything lower than Full Power changes it to Class II Bluetooth.
Batch Mode
Batch mode is used to store bar code data when a scanner is out of range of its base or Access Point, or when performing 
inventory.  The data is transmitted to the base or Access Point once the scanner is back in range or when the records are man-
ually transmitted.  
Note: Batch Mode is only supported by the Honeywell Charge and Communication Base (CCB) and Honeywell Access Point 
(AP).  Batch mode has limitations when using multiple scanners to one base or Access Point.  If a cordless system is being 
used in “multiple link mode,” where up to 7 scanners are to be connected to one base or Access Point, some accumulated 
or batched scans could be lost if scanners are constantly being moved in and out of range.
Automatic Batch Mode stores bar code data when the scanner is out of range of the base or Access Point.  The data is auto-
matically transmitted to the base or Access Point once the scanner is back in range.  When the scanner’s buffer space is full, 
any bar codes scanned generate an error tone.  In order to scan bar codes again, the scanner must be moved back into range 
of the base or Access Point so data can be transmitted. 
Inventory Batch Mode stores bar code data, whether or not you are in range of the base or Access Point.  To transmit the 
stored data to the base or Access Point, either place the scanner in the base, or scan Transmit Inventory Records (page 3-17).  
When the scanner’s buffer space is full, any bar codes scanned generate an error tone.  In order to scan bar codes again, the 
data must be transmitted to the base or Access Point.  Once the data is transmitted, it is cleared in the scanner.
Full Power
R
e
d
uced Po
w
e
r
1902
Scanner
802.11
LAN
* Full Power
Medium Power
Medium Low Power
Low Power
3 - 14
Persistent Batch Mode is the same as Inventory Batch Mode, except that once the data is transmitted to the base or Access 
Point, it is retained in the scanner.  If you want to transmit more than once, you can do so using this mode.  In order to clear the 
scanner’s buffer, you must scan Clear All Codes (see page 3-17).
Default = Batch Mode Off.
Batch Mode Beep
When scanning in Inventory Batch Mode  (page 3-14), the scanner beeps every time a bar code is scanned.   If using a 
Granit scanner, it also vibrates.  When Batch Mode Beep is On, you will also hear a click when each bar code is sent to the 
host.  If you do not want to hear these clicks, scan Batch Mode Beep Off.  Default = Batch Mode Beep On.
Batch Mode Storage
When a scanner is storing data during a Batch Mode process, you can select whether the data is stored in Flash memory 
or in RAM.  
Flash Storage: The scanner writes any untransmitted data to flash memory prior to powering down.  The data will still be 
there when the scanner powers back up.  However, the scanner will power down, even with untransmitted data, if it reaches 
a power down timeout or if the battery power is very low. 
* Batch Mode Off
Automatic Batch Mode
Inventory Batch Mode
Persistent Batch Mode
Batch Mode Beep Off
* Batch Mode Beep On
3 - 15
RAM Storage: The scanner will not power down while it contains data that has not been transmitted to the base or Access 
Point, even if it reaches a power down timeout.  However, if the scanner runs out of battery power, it will power down and 
the data will be lost.
Default = Flash Storage.
Batch Mode Quantity
When in Batch Mode, you may wish to transmit the number of multiple bar codes scanned, rather than a single bar code 
multiple times.  For example, if you scan three bar codes called XYZ with Batch Mode Quantity Off, when you transmit 
your data it will appear as XYZ three times.  Using Batch Mode Quantity On and the Quantity Codes (page 3-16), you 
could output your data as “XYZ, 00003” instead.
Note: If you wish to format your output, for example, place a CR or tab between the bar code data and the quantity, refer 
to Data Formattingbeginning on page 7-1.
Default = Batch Mode Quantity Off. 
Entering Quantities
Quantity Codes (page 3-16) allow you to enter a quantity for the last item scanned, up to 9999 (default = 1).  Quantity digits 
are shifted from right to left, so if a 5th digit is scanned, the 1st digit scanned is discarded and the 2nd, 3rd and 4th digits 
are moved to the left to accommodate the new digit.  
For example, if the Quantity 5 bar code is scanned after the quantity has been set to 1234, then the 1 is dropped, the quan-
tity will be 2345.
Example: Add a quantity of 5 for the last item scanned.
1. Scan the item's bar code.
2. Scan the quantity 5 bar code.
Example: Add a quantity of 1,500 for the last item scanned.
1. Scan the item's bar code. 
2. Scan the quantity 1 bar code.
3. Scan the quantity 5 bar code.
4. Scan the quantity 0 bar code.
5. Scan the quantity 0 bar code.
Example: Change a quantity of 103 to 10.
To correct an incorrect quantity, scan the quantity 0 bar code to replace the incorrect digits, then scan the correct quantity 
bar codes.
* Flash Storage
RAM Storage
* Batch Mode Quantity Off
Batch Mode Quantity On
3 - 16
1. Scan the quantity 0 bar code to change the quantity to 1030.
2. Scan the quantity 0 bar code to change the quantity to 0300.
3. Scan the quantity 1 bar code to change the quantity to 3001.
4. Scan the quantity 0 bar code to change the quantity to 0010.
Default = 1.
Quantity Codes
0
1
2
3
4
5
6
7
8
9
3 - 17
Batch Mode Output Order
When batch data is transmitted, select whether you want that data sent as FIFO (first-in first-out), or LIFO (last-in first-out).  
Default = Batch Mode FIFO.
Total Records
If you wish to output the total number of bar codes scanned when in Batch Mode, scan Total Records.  
Delete Last Code
If you want to delete the last bar code scanned when in Batch Mode, scan Delete Last Code.
Clear All Codes
If you want to clear the scanner’s buffer of all data accumulated in Batch Mode, scan Clear All Codes.
Transmit Records to Host
If you are operating in Inventory Batch Mode (see Inventory Batch Mode  on page 3-14), you must scan the following bar 
code to transmit all the stored data to the host system.
* Batch Mode FIFO
Batch Mode LIFO
Total Records 
Delete Last Code
Clear All Codes
Transmit Inventory Records
3 - 18
Batch Mode Transmit Delay
Sometimes when accumulated scans are sent to the host system, the transmission of those scans is too fast for the appli-
cation to process.  To program a transmit delay between accumulated scans, scan one of the following delays.  Default = 
Off.
Note: In most cases, a short (250 ms (milliseconds)) delay is ideal, however, longer delays may be programmed.  Contact 
Technical Support (page -xi) for additional information.
Multiple Scanner Operation
Note: Multiple Scanner Operation Mode allows you to link up to 7 scanners to one base or Access Point.  You cannot join an 
8th scanner until you unlink one of the 7 scanners or take a scanner out of range.
To put the scanner in multiple scanner mode, scan the bar code below.  Once you scan this bar code, the scanner is unlinked 
from the base or Access Point and must either be placed into the base, or you must scan the Access Point linking bar code in 
order to relink.
Scanner Name
You may assign a name to each scanner you are using for identification purposes.  For example, you may want to have a unique 
identifier for a scanner that is receiving imaging commands sent from the base or Access Point.
The default name is in the format “ScannerName_Model_SN_XXXXXXXXXX”  If you have more than one scanner linked to a 
base, and they all have the same name, the first scanner linked to the base receives commands.  When renaming a series of 
scanners with identical names, unlink all except one of the scanners from the base.
Perform the rename operation using either the bar codes on page 3-19, or by sending the serial command :Scanner-
Name:BT_NAMNewName. where ScannerName is the current name of the scanner, and NewName is the new name for the 
scanner.  If you wish to change the names of additional scanners, link them one at a time and repeat the :ScannerName:BT_N-
AMNewName. command for each scanner.
* Batch Mode Transmit Delay Off
(No Delay)
Batch Mode Transmit Delay Short
(250 ms)
Batch Mode Transmit Delay Medium
(500 ms)
Batch Mode Transmit Delay Long
(1000 ms)
Multiple Scanner Operation
Documents you may be interested