4 - 1
4
Input/Output Settings
Power Up Beeper
Note: This feature does not apply to the CCB02-100BT/CCB05-100BT base.
The scanner can be programmed to beep when it’s powered up.  If you are using a cordless system, the base can also be pro-
grammed to beep when it is powered up.  Scan the Off bar code(s) if you don’t want a power up beep.  Default = Power Up 
Beeper On - Scanner.
Beep on BEL Character
You may wish to force the scanner to beep upon a command sent from the host.  If you scan the Beep on BEL On bar code 
below, the scanner will beep every time a BEL character is received from the host.  Default = Beep on BEL Off.
Power Up Beeper Off - 
Scanner
* Power Up Beeper On - 
Scanner
Power Up Beeper Off - 
Cordless Base
Power Up Beeper On - 
Cordless Base
*Beep on BEL Off
Beep on BEL On
Pdf metadata extract - add, remove, update PDF metadata in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# Developers to Read, Add, Edit, Update and Delete PDF Metadata
change pdf metadata; remove pdf metadata
Pdf metadata extract - VB.NET PDF metadata library: add, remove, update PDF metadata in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Enable VB.NET Users to Read, Write, Edit, Delete and Update PDF Document Metadata
batch edit pdf metadata; clean pdf metadata
4 - 2
Trigger Click
To hear an audible click every time the scanner trigger is pressed, scan the Trigger Click On bar code below.  Scan the Trigger 
Click Off code if you don’t wish to hear the click.  (This feature has no effect on serial or automatic triggering.)  Default = Trigger 
Click Off.
Good Read and Error Indicators
Beeper – Good Read
The beeper may be programmed On or Off in response to a good read.  Turning this option off only turns off the beeper 
response to a good read indication.  All error and menu beeps are still audible.  Default = Beeper - Good Read On.
Beeper Volume – Good Read
The beeper volume codes modify the volume of the beep the scanner emits on a good read.  Default = High for Granit/
Xenon, Low for Xenon HC.
*Trigger Click Off
Trigger Click On
Beeper - Good Read Off
* Beeper - Good Read On
* Low
Medium
* High
Off
VB.NET PDF Image Extract Library: Select, copy, paste PDF images
Get image information, such as its location, zonal information, metadata, and so on. Extract image from PDF free in .NET framework application with trial SDK
pdf xmp metadata viewer; remove metadata from pdf acrobat
C# PDF Image Extract Library: Select, copy, paste PDF images in C#
information, such as its location, zonal information, metadata, and so on. Able to edit, add, delete, move, and output PDF document image. Extract image from PDF
metadata in pdf documents; acrobat pdf additional metadata
4 - 3
Beeper Pitch – Good Read
The beeper pitch codes modify the pitch (frequency) of the beep the scanner emits on a good read.  The Medium pitch dif-
fers for the Xenon and Granit scanners.  Default = Medium.
Vibrate – Good Read
Note: Vibration settings apply only to Granit Devices.
The scanner vibrates once when a bar code is successfully read, and twice when a programming bar code is successfully 
read.  When a programming bar code is unsuccessful, the scanner emits one long vibration (2 times the Vibrate Duration 
length).  Scan Vibrate - Good Read Off to keep the scanner from vibrating.     Default = Vibrate - Good Read On.
Vibrate Duration
If you want to set the length for the good read vibration, scan the bar code below, then set the duration (from 100 - 
2,000 milliseconds) by scanning digits from the inside back cover, then scanning Save.  Default = 300 ms.
Low (1600 Hz)
* Medium - Xenon
(2700 Hz)
* Medium - Granit
(3200 Hz)
High (4200 Hz)
Vibrate- Good Read Off
* Vibrate- Good Read On
Vibrate Duration
C# PDF Page Extract Library: copy, paste, cut PDF pages in C#.net
|. Home ›› XDoc.PDF ›› C# PDF: Extract, Copy and Paste PDF Pages. C#.NET Sample Code: Extract PDF Pages and Save into a New PDF File in C#.NET.
pdf xmp metadata editor; extract pdf metadata
VB.NET PDF Library SDK to view, edit, convert, process PDF file
Feel free to define text or images on PDF document and extract accordingly. Multiple metadata types of PDF file can be easily added and processed.
batch update pdf metadata; delete metadata from pdf
4 - 4
Beeper Pitch – Error
The beeper pitch codes modify the pitch (frequency) of the sound the scanner emits when there is a bad read or error.  
Default = Razz.
Beeper Duration – Good Read
The beeper duration codes modify the length of the beep the scanner emits on a good read.  Default = Normal.
LED – Good Read
The LED indicator can be programmed On or Off in response to a good read.  Default = On.
* Razz (250 Hz)
Medium (3250 Hz)
High (4200 Hz)
* Normal Beep
Short Beep
Short Beep
* LED - Good Read On
LED - Good Read Off
C# PDF Text Extract Library: extract text content from PDF file in
XDoc.PDF ›› C# PDF: Extract PDF Text. C# PDF - Extract Text from PDF in C#.NET. Feel Free to Extract Text from PDF Page, Page Region or the Whole PDF File.
view pdf metadata; remove metadata from pdf online
VB.NET PDF Text Extract Library: extract text content from PDF
PDF ›› VB.NET PDF: Extract PDF Text. VB.NET PDF - Extract Text from PDF Using VB. How to Extract Text from PDF with VB.NET Sample Codes in .NET Application.
read pdf metadata java; pdf xmp metadata
4 - 5
Number of Beeps – Good Read
The number of beeps of a good read can be programmed from 1 - 9.  The same number of beeps will be applied to the 
beeper and LED in response to a good read.  For example, if you program this option to have five beeps, there will be five 
beeps and five LED flashes in response to a good read.  The beeps and LED flashes are in sync with one another.  To 
change the number of beeps, scan the bar code below and then scan a digit (1-9) bar code and the Save bar code on the 
Programming Chart inside the back cover of this manual.  Default = 1.
Number of Beeps – Error
The number of beeps and LED flashes emitted by the scanner for a bad read or error can be programmed from 1 - 9.  For 
example, if you program this option to have five error beeps, there will be five error beeps and five LED flashes in response 
to an error.  To change the number of error beeps, scan the bar code below and then scan a digit (1-9) bar code and the 
Save bar code on the Programming Chart inside the back cover of this manual.  Default = 1.
Beeper Volume Max
Note: The Beeper Volume Max feature only applies to Granit products.
Scan the following bar code to set all error and good read beeps to the maximum volume.  This feature also sets the Beeper 
Pitch – Good Read to the highest level.
Good Read Delay
This sets the minimum amount of time before the scanner can read another bar code.  Default = 0 ms (No Delay).
Number of Good Read Beeps/LED Flashes
Number of Error Beeps/LED Flashes
Beeper Volume Max
* No Delay
Short Delay (500 ms)
Medium Delay (1,000 ms)
VB.NET PDF Form Data Read library: extract form data from PDF in
Data: Read, Extract Field Data. |. Home ›› XDoc.PDF ›› VB.NET PDF: Read, Extract Field Data. VB.NET PDF - Read and Extract Field Data in VB.NET.
modify pdf metadata; pdf metadata editor
C# PDF Library SDK to view, edit, convert, process PDF file for C#
Feel free to define text or images on PDF document and extract accordingly. Multiple metadata types of PDF file can be easily added and processed in C#.NET
bulk edit pdf metadata; rename pdf files from metadata
4 - 6
User-Specified Good Read Delay
If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0 - 30,000 mil-
liseconds) by scanning digits from the inside back cover, then scanning Save. 
Manual Trigger Modes
When in manual trigger mode, the scanner scans until a bar code is read, or until the trigger is released.  Two modes are avail-
able, Normal and Enhanced.   Normal mode offers good scan speed and the longest working ranges (depth of field).  
Enhanced mode will give you the highest possible scan speed but slightly less range than Normal mode.  Enhanced mode is 
best used when you require a very fast scan speed and don’t require a long working range.  Default = Manual Trigger-Normal.
Note: Granit 1980i and 1981i do not support Enhanced Manual Trigger Mode. 
Serial Trigger Mode
You can activate the scanner either by pressing the trigger, or using a serial trigger command (see Trigger Commandson page 
12-3).  When in serial mode, the scanner scans until a bar code has been read or until the deactivate command is sent.  The 
scanner can also be set to turn itself off after a specified time has elapsed (see Read Time-Out, which follows).
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the scanner’s trigger when using serial commands to trigger the 
scanner.  Once the scanner has timed out, you can activate the scanner either by pressing the trigger or using a serial trig-
ger command.  After scanning the Read Time-Out bar code, set the time-out duration (from 0-300,000 milliseconds) by 
scanning digits on the Programming Chart inside the back cover, then scanning Save.  Default = 30,000 ms.
Long Delay (1,500 ms)
User-Specified Good Read Delay
* Manual Trigger - Normal
Manual Trigger - Enhanced
Read Time-Out
4 - 7
Presentation Mode
Presentation Mode uses ambient light and scanner illumination to detect bar codes.  When in Presentation Mode, the LEDs 
remain dim until a bar code is presented to the scanner, then the aimer turns on and the LEDs turn up to read the code.  If the 
light level in the room is not high enough, Presentation Mode may not work properly   
Note: If you are using a cordless charge base in Presentation Mode, the battery will not charge unless the power supply is 
plugged into the base’s auxiliary power port.
Scan the following bar code to program your scanner for Presentation Mode.
Presentation LED Behavior after Decode
When a scanner is in presentation mode, the LEDs dim 30 seconds after a bar code is decoded.  If you wish to dim the 
LEDs immediately after a bar code is decoded, scan the LEDs Off bar code, below.  Default = LEDs On.
Presentation Sensitivity
Presentation Sensitivity is a numeric range that increases or decreases the scanner's reaction time to bar code presenta-
tion.  To set the sensitivity, scan the Sensitivity bar code, then scan the degree of sensitivity (from 0-20) from the inside 
back cover, and Save.  0 is the most sensitive setting, and 20 is the least sensitive.  Default = 1.
Note: Granit 1980i and 1981i do not support this setting.
Presentation Centering
Use Presentation Centering to narrow the scanner’s field of view when it is in the stand to make sure the scanner reads 
only those bar codes intended by the user.  For instance, if multiple codes are placed closely together, Presentation Center-
ing will insure that only the desired codes are read.  
Note: To adjust centering when the scanner is hand-held, see Centering(page 4-15).
If a bar code is not touched by a predefined window, it will not be decoded or output by the scanner.  If Presentation Center-
ing is turned on by scanning Presentation Centering On, the scanner only reads codes that pass through the centering 
window you specify using the Top of Presentation Centering Window, Bottom of Presentation Centering Window, 
Left, and Right of Presentation Centering Window bar codes. 
In the example below, the white box is the centering window.  The centering window has been set to 20% left, 30% right, 
8% top, and 25% bottom.  Since Bar Code 1 passes through the centering window, it will be read.  Bar Code 2 does not 
pass through the centering window, so it will not be read.
Presentation Mode
* LEDs On
LEDs Off
Sensitivity
4 - 8
Note: A bar code needs only to be touched by the centering window in order to be read.  It does not need to pass completely 
through the centering window.
Scan Presentation Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the 
centering window.  Then scan the percent you want to shift the centering window using digits on the inside back cover of 
this manual.  Scan Save.   Default Presentation Centering = 40% for Top and Left, 60% for Bottom and Right.
0
Bar Code 1
Bar Code 2
10
20
30
40
50
60
70
80
90
100%
100
90
80
70
60
50
40
30
20
10
0%
Presentation Centering On
* Presentation Centering Off
Top of Presentation Centering 
Window 
Bottom of Presentation 
Centering Window
Left of 
PresentationCentering 
Window
4 - 9
In-Stand Sensor Mode
Note: The In-Stand Sensor feature only applies to Xenon products.
This feature senses when the scanner is removed from the stand and tells it to begin manual triggering.  When Sensor On is 
enabled, the scanner defaults to Streaming Presentation Mode when it is in the stand, and to Manual Trigger Mode when it is 
removed from the stand.  Default = Sensor On.
Note: If you are taking images (see Imaging Commands beginning on page 9-1), you must set the In-Stand Sensor to Off.
You may program a Streaming Presentation Mode (Normal, Enhanced, or Mobile Phone) you wish to use for in-stand scanning, 
and a Manual Trigger mode (Normal, Enhanced, or Mobile Phone) you wish to use for out-of-stand scanning.  To do this, you 
must first scan the preferred Streaming Presentation mode (see below), then scan the Manual Trigger mode (see page 4-6 and 
page 4-11) you want to use.
Poor Quality Codes
Poor Quality 1D Codes
This setting improves the scanner’s ability to read damaged or badly printed linear bar codes.  When Poor Quality 1D 
Reading On is scanned, poor quality linear bar code reading is improved, but the scanner’s snappiness is decreased, mak-
ing it less aggressive when reading good quality bar codes.  This setting does not affect 2D bar code reading.  Default = 
Poor Quality 1D Reading Off.
Right of Presentation Centering 
Window
* Sensor On
Sensor Off
Poor Quality 1D Reading On
* Poor Quality 1D Reading Off
4 - 10
Poor Quality PDF Codes
This setting improves the scanner’s ability to read damaged or badly printed PDF codes by combining information from mul-
tiple images.  When Poor Quality PDF On is scanned, poor quality PDF code reading is improved, but the scanner’s snap-
piness is decreased, making it less aggressive when reading good quality bar codes.  This setting does not affect 1D bar 
code reading.  Default = Poor Quality PDF Reading Off.
CodeGate
®
When CodeGate is On, the trigger is used to allow decoded data to be transmitted to the host system.  The scanner remains on, 
scanning and decoding bar codes, but the bar code data is not transmitted until the trigger is pressed.  When CodeGate is Off, 
bar code data is transmitted when it is decoded.  Default = CodeGate Off Out-of-Stand.
Streaming Presentation™ Mode
When in Streaming Presentation mode, the scanner’s aimer goes out after a short time, but the scan illumination remains on all 
the time to continuously search for bar codes.  Two modes are available, Normal and Enhanced.   Normal mode offers good 
scan speed and the longest working ranges (depth of field).  Enhanced mode will give you the highest possible scan speed but 
slightly less range than Normal mode.  Enhanced mode is best used when you require a very fast scan speed and don’t require 
a long working range.
Note: Granit 1980i and 1981i do not support Enhanced Streaming Presentation Mode. 
Poor Quality PDF Reading On
* Poor Quality PDF Reading Off
* CodeGate Off
Out-of-Stand
CodeGate On
Out-of-Stand
Streaming Presentation Mode 
- Normal
Streaming Presentation Mode 
- Enhanced