Acondition is an ANDed grouping of two through nine indicators that must all be
in effect (set off if N is specified; set on if N is not specified) before the field or
keyword is selected. You can specify a maximum of nine indicators for each
condition and nine conditions for each field or keyword. Therefore, a maximum of
81 indicators can be specified for each field or keyword. An AND condition occurs
when you specify a condition requiring that more than one indicator must be on or
off before the condition is satisfied. The first indicator you specify, AND the
second, AND the third, and so on, must all be in effect before the condition is
satisfied and the field or the keyword is selected. You must specify the field or the
keyword on the same line as the last (or only) set of indicators specified.
You can also specify several conditions for a field or keyword so that if any one of
them is satisfied, the field or the keyword is selected. This is called an OR
relationship. In an OR relationship, if the first condition is satisfied, OR the second
condition, OR the third condition, and so on, the field or the keyword is selected.
Conditions within the OR relationship can consist of just one indicator or can
consist of several indicators ANDed together. Indicators can be ANDed to form a
condition. Conditions can be ORed to give your program several ways to select the
field or keyword.
Position 7 (AND)
If you need more than three indicators to form an ANDed condition,
specify the indicators on the next line or lines. You can specify an A in
position 7 on the second or following lines to continue the ANDed
condition, or you can leave it blank because A is the default.
Position 7 (OR)
If you specify several conditions that are to be ORed together, each
condition must start on a new line and each condition, except the first,
must have an O in position 7. An O specified for the first condition
produces a warning message, and that position is assumed to be blank.
Position 8, 11, 14 (NOT)
If you want an indicator to be off instead of on to satisfy a condition,
specify an N in the position just preceding the indicator (position 8, 11, or
14).
DDS Conditioning a Field for More than One Keyword
If you are conditioning a field, the field name (or the constant) and the last (or
only) indicator must be on the same line. If you do not select the field for an
output operation, no keywords specified for that field are in effect, regardless of
how the keywords are conditioned. For example, in Figure 91 on page 110, FLDA is
selected if either indicator 01 is off or indicator 02 is on. If FLDA is not selected,
any keyword associated with that field, such as DSPATR(HI), is ignored.
If you want to condition one or more keywords, the last (or only) indicator must
appear on the same line as the keywords. If the conditioning applies to keywords
on more than one line, you must use keyword continuation for the indicators to
apply to all keywords. See Chapter 1. Introduction to DDS Reference, for more
information about DDS syntax rules.
Display Size Condition Names
If you want your program to open this file to display devices with display sizes
other than 24 lines x 80 characters, specify the DSPSIZ (Display Size) keyword at
the file level. You can then condition the use of keywords and the location of fields
Chapter 3. Keywords for Display Files in DDS
111
Pdf signature field - C# PDF Form Data fill-in Library: auto fill-in PDF form data in C#.net, ASP.NET, MVC, WinForms, WPF
Online C# Tutorial to Automatically Fill in Field Data to PDF
convert an existing form into a fillable pdf; create a fillable pdf form from a pdf
Pdf signature field - VB.NET PDF Form Data fill-in library: auto fill-in PDF form data in vb.net, ASP.NET, MVC, WinForms, WPF
VB.NET PDF Form Data fill-in library: auto fill-in PDF form data in vb.net, ASP.NET, MVC, WinForms, WPF
allow users to attach to pdf form; convert pdf to fillable form online
with the “display size condition names” specified for the DSPSIZ keyword. If you
do not specify the DSPSIZ keyword, your program can only open this file to
display devices with a 24 x 80 display.
The following table shows the display size condition name for each display device.
Device
Display Size
Display Size
Condition
Name (See
Note 1)
3179
3180
3196
3197 (Models C1 and C2)
3476
3487 (Models HA, HC, HG, and HW)
3488 (See Note 2)
3486 (Models BA and BG)
5251 (Models 11 and 12)
5291
5292
24 x 80
characters
(1920
characters)
*DS3
3180
3197 (Models D1, D2, W1, and W2)
3477 (Models FA, FC, FD, and FG)
3487 (Models HA, HC, HG, and HW)
27 x 132
characters
(3564
characters)
*DS4
:
Note 1 You can specify a user-defined display size condition name instead of *DS3, or
*DS4. See the DSPSIZ keyword description for an explanation of how to specify
user-defined condition names.
Note 2 Dependent on monitor attached to display device.
Figure 92 shows how to specify the DSPSIZ keyword and display size condition
names.
In Figure 92, the display size condition name for the primary display size is
defined as *LARGE 1 (column 52 to 64) and the display size condition name for
the secondary display size is defined as *NORMAL 2 (column 66 to 75). FIELDA
appears on line 1, position 2 for both display sizes. FIELDB appears on line 1,
position 120 for the primary display size (*LARGE by default), and on line 1,
position 49 for the secondary display size (*NORMAL specified in positions 9
through 16). FIELDC appears on line 27, position 1 for the primary display size
and on line 15, position 1 for the secondary display size. Only secondary display
sizes (in this example, *NORMAL) can be used to condition field locations.
|...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
A
1
2
00010A
DSPSIZ(27 132 *LARGE 24 80 *NORMAL)
00020A
R RECORDA
00030A
FIELDA
10 0
1 2
00040A
FIELDB
10 0
1120
00050A *NORMAL
1 49
00060A
FIELDC
10 0 27 1
00070A *NORMAL
15 1
A
Figure 92. Specifying the DSPSIZ Keyword and Display Size Condition Names
112
OS/400 DDS Reference V4R5
C# PDF Digital Signature Library: add, remove, update PDF digital
things. Add a signature or an empty signature field in any PDF file page. Search unsigned signature field in PDF document. Prepare
create pdf fillable form; convert an existing form into a fillable pdf form
VB.NET PDF Digital Signature Library: add, remove, update PDF
things. Add a signature or an empty signature field in any PDF file page. Search unsigned signature field in PDF document. Prepare
convert excel to fillable pdf form; converting a word document to a fillable pdf form
Use display size condition names similar to the way you use option indicators,
except that display size condition names do not appear in your program and do
not appear in the output record. A display size condition is on if the display file is
opened to the corresponding display size. When you use display size condition
names, the following rules apply:
v Specify the DSPSIZ keyword to designate the primary display size and the
secondary display size. If you do not specify the DSPSIZ keyword, the default is
DSPSIZ(*DS3).
v You can specify only one display size condition name for a condition. You
cannot specify AND or OR with other display size condition names or option
indicators.
v The display size condition name must start in position 9.
v The display size condition name can be user-defined. See the keyword
description for “DSPSIZ (Display Size) Keyword for Display Files” on page 213
for more details.
v You can specify N in position 8 to designate a NOT condition (for the primary
display size).
Note: Specifying N in position 8 implies an OR relationship between the
remaining display size condition names. For example, N*DS4 implies
*DS3 when *DS3 is specified as a secondary display size on the DSPSIZ
keyword.
v You must not use display size condition names that alter the line or position
sequence of a field within a record. Fields are ordered in the display file by
primary locations. A severe error occurs at file creation time if the secondary
location alters this primary sequence.
For example, FLD1 and FLD2 are on the primary display located on line 2,
position 2 and line 4, position 2, respectively. You cannot use a display size
condition name to display FLD2 ahead of FLD1 on the display (on line 1) for a
secondary display size.
v When you specify the location of a field on a secondary display size, you can
only specify positions 8 through 16 (conditioning) and 39 through 44 (location).
v If you do not specify a condition name for a keyword for which condition
names are valid, the primary condition name specified on the DSPSIZ keyword
is the default.
Table 2 shows the correct and incorrect combinations of display size condition
names and primary display sizes, when both display sizes are specified on the
DSPSIZ keyword and the first one specified varies.
Table 2. Valid Display Size Condition Specifications
Display Size Condition
Name
1
24 x 80 DSPSIZ(*DS3...) or
DSPSIZ(24 80...) Primary
Display Size
27 x 132 DSPSIZ(*DS4...) or
DSPSIZ(27 132...) Primary
Display Size
*DS3
Error
2
Valid
*DS4
Valid
Error
2
N*DS3
Valid
Error
3
N*DS4
Error
3
Valid
Chapter 3. Keywords for Display Files in DDS
113
C# PDF insert image Library: insert images into PDF in C#.net, ASP
field. Access to freeware download and online C#.NET class source code. How to insert and add image, picture, digital photo, scanned signature or logo into PDF
create fill in pdf forms; change pdf to fillable form
How to C#: Basic SDK Concept of XDoc.PDF for .NET
To be specific, you can edit PDF password and digital signature, and set PDF file permission. Class: PasswordSetting. Class: PDFDigitalSignatureHandler.
convert pdf fillable form to word; convert word to pdf fillable form online
Table 2. Valid Display Size Condition Specifications (continued)
Display Size Condition
Name
1
24 x 80 DSPSIZ(*DS3...) or
DSPSIZ(24 80...) Primary
Display Size
27 x 132 DSPSIZ(*DS4...) or
DSPSIZ(27 132...) Primary
Display Size
:
Notes:
1.
See the DSPSIZ keyword description for user-defined names for these display size
condition names.
2.
The display size condition names are in error because that display size is the primary
display size.
3.
These display size condition names are in error because a primary and a secondary
location are implied for the same display size. A condition name specified with the
NOT condition implies an OR relationship. For example, N*DS4 implies *DS3.
Figure 93 and Figure 94 show display size conditioning for a keyword (in this case,
MSGLOC, Message Location).
In Figure 93, the display size condition name *DS4 is specified, so that the message
line is line 26 for a 27 x 132 display and line 25 (the default) for a 24 x 80 display.
In Figure 94, the message line is also line 26 for the 27 x 132 display and line 25
(the default) for the 24 x 80 display, even though no display size condition name is
specified, because the primary display size (*DS4) specified with the DSPSIZ
keyword is the default.
DDS Type of Name or Specification for display files (Position
17)
Specify a value in this position to identify the type of name in positions 19 through
28. The valid entries for display files are:
Entry Meaning
R
Record format name
H
Help specification
Blank Field name
Figure 91 on page 110 shows you how to code the name type.
|...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
00030A
DSPSIZ(*DS3 *DS4)
00040A *DS4
MSGLOC(26)
A
Figure 93. Display Size Conditioning (Example 1)
|...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
00080A
DSPSIZ(*DS4 *DS3)
00081A
MSGLOC(26)
A
Figure 94. Display Size Conditioning (Example 2)
114
OS/400 DDS Reference V4R5
VB.NET PDF: Basic SDK Concept of XDoc.PDF
To be specific, you can edit PDF password and digital signature, and set PDF file permission. Class: PasswordSetting. Class: PDFDigitalSignatureHandler.
asp.net fill pdf form; create a pdf form to fill out
VB.NET PDF insert image library: insert images into PDF in vb.net
project. Import graphic picture, digital photo, signature and logo into PDF document. file. Insert images into PDF form field in VB.NET. An
pdf fillable form; create a fillable pdf form from a word document
For more information on types of names, see the section, “DDS Name for display
files (Positions 19 through 28)”. For more information on Help specifications, see
“HELP (Help) Keyword for Display Files” on page 244.
DDS Reserved for display files (Position 18)
This position does not apply to any file type. Leave this position blank unless you
use it for comment text.
DDS Name for display files (Positions 19 through 28)
Use these positions to specify record format names and field names.
Refer to “DDS Syntax Rules” on page 4 for rules to use when specifying record or
field names in DDS.
The names must begin in position 19.
Figure 91 on page 110 shows you how to specify record format names and field
names.
DDS Record Format Name
When you specify R in position 17, the name specified in positions 19 through 28
is a record format name. You can specify more than one record format for a
display file, but each record format name must be unique within that file.
DDS Field Name
When position 17 is left blank, the name you specified in positions 19 through 28 is
afield name. Field names must be unique within the record format.
DDS Constant Fields
Constant fields are unnamed fields (positions 19 through 28 must be blank). The
following rules apply to constant fields:
v Positions 17 through 38 must be blank.
v The location of the field is required (positions 39 through 44).
v The field can be conditioned using option indicators (positions 7 through 16).
v You can specify secondary display locations using display size condition names
(positions 8 through 16). Only the display size condition name and location can
be specified. That is, positions 7, 17 through 38, and 45 through 80 must be
blank.
v The constant itself is defined in positions 45 through 80 using one of the
following entries:
– Explicit DFT keyword (specify the value within apostrophes with the DFT
keyword)
– Implicit DFT keyword (specify the value within apostrophes without the DFT
keyword)
– DATE keyword (specify no value; see the DATE keyword description)
– TIME keyword (specify no value; see the TIME keyword description)
– SYSNAME keyword (specify no value; see the SYSNAME keyword
description)
Chapter 3. Keywords for Display Files in DDS
115
VB.NET PDF Library SDK to view, edit, convert, process PDF file
NET program. Password, digital signature and PDF text, image and page redaction will be used and customized. PDF Annotation Edit.
fillable pdf forms; convert word form to fillable pdf
C# Create PDF Library SDK to convert PDF from other file formats
PDF file. What's more, you can also protect created PDF file by adding digital signature (watermark) on PDF using C# code. Create
convert pdf file to fillable form; change font pdf fillable form
– USER keyword (specify no value; see the USER keyword description)
– MSGCON keyword (specify the message description, the message file, the
library name, and the length of the message description)
How to Determine the Order of Fields in a Record Format Using
DDS
The order of the name fields that you specify in a record format is the order in
which the name fields appear in your program when it is compiled. (Unnamed
fields do not appear in your program.)
The locations of named and unnamed fields you specify in positions 39 through 44
determine the order that the fields appear in the display. See “DDS Location for
display files (Positions 39 through 44)” on page 135. Hidden fields (H in position
38) and Program-to-System fields (P in position 38) do not appear on the display.
DDS Reference for display files (Position 29)
Specify R in this position to use the reference function of the OS/400 program to
copy the attributes of a previously defined named field (called the referenced field)
to the field you are defining. The referenced field can be previously defined in
either the display file you are defining or a previously created database file (the
database file to be referred to is specified with the REF or REFFLD keyword). The
field attributes referred to are the length, data type, and decimal positions of the
field, as well as the following keywords:
v ALIAS (alternative name)
v CCSID (Coded Character Set Identifier)
v FLTPCN (floating-point precision)
v TEXT
v DATFMT
v DATSEP
v TIMFMT
v TIMSEP
v Editing and validity checking keywords
If you do not specify R, you cannot use the reference function for this field and
you must specify field attributes for this field.
Position 29 must be blank at the file, record, and help levels.
If the name of the referenced field is the same as the field you are defining, you
need only specify R in position 29 (in addition to specifying the name of the field
you are defining in positions 19 through 28). If the name of the field you are
defining is different from the name of the referenced field you must specify the
name of the referenced field with the REFFLD (Referenced Field) keyword.
You can specify the name of the file defining the referenced field as a parameter
value with the REF (Reference) or the REFFLD keyword. See “REF (Reference)
Keyword for Display Files” on page 322, “REFFLD (Referenced Field) Keyword for
Display Files” on page 323, and Appendix A. When to Specify REF and REFFLD
Keywords for DDS Files, for explanations of how the OS/400 program finds the
referenced field.
116
OS/400 DDS Reference V4R5
C# PDF remove image library: remove, delete images from PDF in C#.
in Field Data. Field: Insert, Delete, Update Field. graphic picture, digital photo, scanned signature, logo, etc. remove multiple or all images from PDF document.
create a pdf form to fill out and save; add attachment to pdf form
C# PDF Convert to Images SDK: Convert PDF to png, gif images in C#
in C#.NET class. Create image files including all PDF contents, like watermark and signature in .NET. Turn multipage PDF file into
convert pdf to form fill; convert word to fillable pdf form
You do not need to copy all attributes from the previously defined field to the field
you are defining. To override specific attributes of the referenced field, specify
those attributes for the field you are defining as follows:
v To override the EDTCDE (Edit Code) or EDTWRD (Edit Word) keywords,
specify EDTCDE or EDTWRD for the field you are defining. You can delete
these keywords by specifying the DLTEDT (Delete Edit) keyword for the field
you are defining.
v To override the CHECK (Check), COMP (Comparison), RANGE (Range), and
VALUES (Values) validity checking keywords and the CHKMSGID (Check
Message Identifier) keyword, specify any validity checking keyword for the field
you are defining. You can delete these keywords by specifying the DLTCHK
(Delete Check) keyword for the field you are defining.
When you override some specifications, others are also affected, as follows:
v If you specify keyboard shift attribute, field length, or decimal positions for the
field you are defining, neither editing nor validity checking keywords are copied
from the referenced field.
v If you override the previously defined data type to character (by specifying M,
A, X, or W in position 35), decimal positions are not copied. However, if you
specify N, D, or I in position 35 and leave blanks in positions 36 and 37 (decimal
positions), the field you define has the decimal positions of the referenced field.
For D, the decimal positions must be zero.
v Packed decimal and binary fields are not supported for display files. Therefore,
when you refer to fields of these types, the data type assigned is zoned decimal
with a keyboard shift as follows:
– If editing is in effect for the field you are defining, the keyboard shift is
numeric only (Y in position 35).
– If no editing is in effect for the field you are defining, the keyboard shift is
signed numeric (S in position 35).
v When the referenced field contains the REFSHIFT (Reference Shift) keyword, the
value specified for REFSHIFT is used as the display file keyboard shift.
However, if the data type specified for the new field is not compatible with the
keyboard shift specified on the REFSHIFT keyword, the keyword is not copied
to the new field.
Note: Once the display file is created, you can delete or change the referenced file
without affecting the field descriptions in the display file. Delete and create
the display file again to incorporate changes made in the referenced file.
DDS Length for display files (Positions 30 through 34)
You must specify a length for each named field unless you are copying the length
from a referenced field. The length is the number of bytes of data to pass to or
receive from your program when I/O operations are done for the field. This is
called the program length of the field.
The length of a field when it appears on the display is called the display length. The
display length is greater than or equal to the program length. The display length of
afield is determined by the keyboard shift (specified in position 35) and other field
specifications such as decimal positions (positions 36 and 37) and editing functions.
See “DDS Data Type/Keyboard Shift for display files (Position 35)” on page 118 for
more information.
Chapter 3. Keywords for Display Files in DDS
117
The display length does not include beginning and ending attribute characters of a
field. However, you must consider these attribute characters when planning the
display layout for field locations. Within a record, the ending attribute character of
afield can overlap the beginning attribute character of the next field, requiring
only one space between fields. See “DDS Location for display files (Positions 39
through 44)” on page 135 for more information.
The maximum length of a character field is equal to the display size minus one.
(This allows space for the beginning attribute character.) The maximum length of a
numeric (zoned decimal) field is 31 positions. The maximum length of a
single-precision floating-point field is 9 digits. The maximum length of a
double-precision floating-point field is 17 digits.
You must not specify a field length for a constant field. See the DATE, DFT
(Default), MSGCON, or TIME keyword descriptions for explanations of the lengths
of constant fields.
If you specify length, it must be right-justified. Leading zeros are optional.
Figure 95 shows incorrect and correct field length specifications.
If you use a referenced field, you can override the length of the field by specifying
anew value or by specifying the increase or decrease in length. To increase the
length, specify +n, where n is the increase. To decrease the length, specify −n,
where n is the decrease. For example, an entry of +4 for a numeric field indicates a
field that is 4 digits longer than the referenced field.
In some cases, some keywords specified with the field in the database file are not
included in the display file if you specify a value for length. For more information,
see “DDS Reference for display files (Position 29)” on page 116.
Afield cannot occupy the first position on the display. The first position is
reserved for an attribute character. For example, on a 24 by 80 display, an entry of
1in positions 39 through 41 (line), and 1 in positions 42 through 44 (position) is
not allowed for a signed numeric field since the field starts in position 1.
DDS Data Type/Keyboard Shift for display files (Position 35)
The entry you make in position 35 is the data type/keyboard shift attribute for
display files. This entry does not determine the data type of the field used in your
program. The entry in positions 36 and 37 (decimal positions) determines the data
type of the field. See “DDS Decimal Positions for display files (Positions 36 and
37)” on page 131.
|...+....1....+....2....+....3....+....4....+....5
00010A
FIELD1
7
A
00020A
FIELD2
7
A
00030A
FIELD3
R
+7
A
Note: FIELD1 shows the field length specified incorrectly. FIELD2 and FIELD3 show the
field length specified correctly.
Figure 95. Incorrect and Correct Length Specifications
118
OS/400 DDS Reference V4R5
The keyboard shift attribute automatically shifts 5250 work stations with data-entry
keyboards and can, for all keyboards, limit what the work station user can type
into a field. However, the keyboard shift attribute does not shift 5250 work stations
with the typewriter-like keyboard. Nor does the keyboard shift attribute restrict in
any way what your program can write to a field. Your program can write
alphabetic characters to a numeric field and, in most cases, read that field and
receive those characters. Any restrictions are enforced solely by the programming
language used for your program.
DDS Valid Entries for Display Files
Following are valid entries for display files:
Entry Keyboard Shifts
Meaning
Data Type Permitted
Blank
Default
X
Alphabetic only
Character
A
Alphanumeric shift
Character
N
Numeric shift
Character or numeric
S
Signed numeric
Numeric
Y
Numeric only
Numeric
W
Katakana (for Japan only)
Character
I
Inhibit keyboard entry
Character or numeric
D
Digits only
Character or numeric
M
Numeric only character
Character
Data Type
F
Floating point
Numeric
L
Date
T
Time
Z
Timestamp
Figure 91 on page 110 and Figure 96 on page 127 show you how to specify the
keyboard shift attribute.
The keyboard shift attributes are defined in detail in the following sections.
DDS Default (Blank): If you leave position 35 blank, the entry in positions 36
and 37 (decimal positions) determines the data type of the field as follows:
v If you make a valid entry in positions 36 and 37, the data type is zoned decimal
and the keyboard shift attribute is signed numeric (S) unless you also specify an
editing keyword. The keyboard shift attribute is numeric only (Y) when you also
specify an editing keyword.
v If you make no entry in positions 36 and 37, the data type is character and the
keyboard shift attribute is alphanumeric shift (A).
If you specify the REFSHIFT keyword for a referenced field, the specified value is
used. Otherwise, a data type of packed or binary is converted to zoned decimal in
the display file. Conversion to or from packed or binary can occur within your
program.
Alphabetic Only (X) in DDS: Both types of keyboards are in lowershift. Only the
characters A through Z, comma (,), period (.), dash (–), and space ( ) can be typed
in. When you type lowercase characters a through z, uppercase characters are sent
to the program. See “LC (Lowercase) for Display Files” on page 173 for an
explanation of how to permit typing in lowercase characters for the typewriter-like
keyboard on the 5250 work station.
Chapter 3. Keywords for Display Files in DDS
119
Alphanumeric Shift (A) in DDS: Both types of keyboards are in lowershift. All
characters are valid for entry.
Numeric Shift (N) in DDS: Each type of keyboard is shifted to allow numeric
entry: uppershift for the data-entry keyboard and lowershift for the typewriter-like
keyboard. All characters are valid for entry.
The display length for a numeric shift field is one more than the length coded in
positions 30 through 34 when the following conditions occur:
v The field is an unedited, input-capable field.
v The value in the decimal positions field is greater than zero.
The extra position in the display length is for the decimal point.
Note: Input numeric shift fields with specified decimal positions (in positions 36
and 37) are processed by data management as numeric-only fields, except
that editing is not supported. For more information, see the keyboard
attribute section, “Numeric Only (Y) in DDS” on page 121
Signed Numeric (S) in DDS: Each type of keyboard is shifted to allow numeric
entry: uppershift for the data-entry keyboard and lowershift for the typewriter-like
keyboard. You can only type the numbers 0 through 9 into the field (no blanks, no
plus sign, no minus sign). To leave the field, press the Field Exit key, the Field+
key, the Field− key, or a cursor movement key. If you do not type any data into the
field, you can press the Enter key.
You should consider the following differences when you choose between signed
numeric (S) and numeric only (Y):
v Signed numeric restricts the characters that you can type into the field to the
numbers 0 through 9.
v You cannot specify S in position 35 if you also specify the EDTCDE or EDTWRD
keyword.
v Numeric-only performs character removal to remove nonnumeric characters;
signed numeric prevents you from typing in these characters at all.
For input-capable fields only, the display length for the field is one more than the
length specified in positions 30 through 34. The farthest right position on the
display is reserved for a minus sign.
The following considerations apply when the OS/400 program passes the contents
of a signed numeric field to your program:
v Your program always sees a numeric, right-justified, zero-filled field.
v The field is displayed as a right-justified, blank-filled field unless you specify
CHECK(RZ). If you specify CHECK(RZ), the field is displayed as right-adjusted
and zero-filled.
v The OS/400 program does not perform decimal alignment.
v The OS/400 program does not remove characters from the field (as it does for
numeric only fields).
When an input-capable signed numeric field displays and you do not specify
CHECK(RZ), the OS/400 program performs zero suppression by default (the
EDTCDE and EDTWRD keywords are not valid for signed numeric fields).
Negative numbers are handled as follows:
120
OS/400 DDS Reference V4R5
Documents you may be interested
Documents you may be interested