convert pdf to image in asp.net c# : Create pdf fill in form application software cloud html windows wpf class rbafpmst43-part1727

DDSReservedforprinterfiles(Position18)
This position does not apply to any file type. Leave this position blank unless you
use it for comment text.
DDS Name for printer files (Positions 19 through 28)
Use these positions to specify record format names and field names.
Refer to “DDS Syntax Rules” on page 4 for rules to use when specifying record or
field names in DDS.
Name must begin in position 19.
Figure 307 on page 408 shows how to specify record format names and field
names.
Record Format Name in Printer Files
When you specify an R in position 17, the name specified in positions 19 through
28 is a record format name. You can specify more than one record format for a
printer file, but each name must be unique within that file. You must also specify
field names or constant fields to complete a record format in a printer file.
Field Name in Printer Files
When position 17 is left blank, the name specified in positions 19 through 28 is a
field name. Field names must be unique within the record format.
Constant Fields in Printer Files
Constant fields are unnamed fields (positions 19 through 28 must be blank). The
following rules apply when specifying a constant field:
v Positions 17 through 38 must be blank.
v The location of the field is required (positions 39 through 44).
v The field can be conditioned using option indicators (positions 7 through 16).
v A constant field cannot be specified in a record format that has a BOX,
ENDPAGE, GDF, LINE, OVERLAY, or PAGSEG keyword specified on the record,
or a POSITION keyword specified on any of the fields specified within the
record format.
v The constant itself is defined in positions 45 through 80 using one of the
following entries:
– Explicit DFT keyword (specify the value within apostrophes with the DFT
keyword)
– Implicit DFT keyword (specify the value within apostrophes without the DFT
keyword)
– DATE keyword (specify no value; see the DATE keyword description)
– TIME keyword (specify no value; see the TIME keyword description)
– PAGNBR keyword (specify no value; see the PAGNBR keyword description)
– MSGCON keyword (specify the message description, the message file, the
library name, and the length of the message description; see the MSGCON
keyword description)
Chapter4. Keywords for Printer Files
411
Create pdf fill in form - C# PDF Form Data fill-in Library: auto fill-in PDF form data in C#.net, ASP.NET, MVC, WinForms, WPF
Online C# Tutorial to Automatically Fill in Field Data to PDF
create pdf fillable form; pdf signature field
Create pdf fill in form - VB.NET PDF Form Data fill-in library: auto fill-in PDF form data in vb.net, ASP.NET, MVC, WinForms, WPF
VB.NET PDF Form Data fill-in library: auto fill-in PDF form data in vb.net, ASP.NET, MVC, WinForms, WPF
adding a signature to a pdf form; change font size in fillable pdf form
v The EDTCDE or the EDTWRD keyword can be specified for constant fields only
when DATE, TIME, or PAGNBR keywords are also specified.
If you use line numbers you can specify the fields in any order. If you do not use
line numbers, you must specify the fields in the order in which they are to appear
on the printed page.
DDS Reference for printer files (Position 29)
Specify R in position 29 to copy the attributes of a previously defined named field
(the referenced field) to the field you are defining. (If you do not specify R, you must
specify the field attributes.) For example, you might want to reference fields for an
externally defined file to print a report from a database file.
When using the reference function, specify the referenced field name, even if it is
the same as the referencing field. (The referenced field name can be in a previously
created database file specified on the REF or REFFLD keywords.) The field
attributes referenced are the length, data type, and decimal positions of the field,
as well as the ALIAS, FLTPCN, TEXT, DATFMT, DATSEP, TIMFMT, TIMSEP, and
editing keywords.
If the referenced field name is the same as the field you are defining, specify R in
position 29 and the name of the field you are defining in positions 19 through 28.
If the referenced field is different from the field you are defining, specify the name
of the referenced field with the REFFLD keyword.
Position 29 must be blank at the file and record levels.
You can specify the name of the file defining the referenced field as a parameter
value with the REF or the REFFLD keyword. See the REF and REFFLD keyword
descriptions later in this chapter and in Appendix A. When to Specify REF and
REFFLD Keywords for DDS Files, for explanations of how the OS/400 program
finds the referenced field.
If you do not want to copy all the attributes from the previously defined field,
specify those attributes for the field you are defining, as follows:
v To override editing keywords (EDTCDE or EDTWRD), specify EDTCDE or
EDTWRD for the field you are defining. To delete these keywords, specify
DLTEDT for the field you are defining.
v Validity checking keywords (CHECK, COMP, RANGE, VALUES), if specified for
the referenced field, are ignored in the printer file.
When you override some specifications, others are affected:
v If you specify a value for data type, field length, or decimal positions for the
field you are defining, editing keywords are not copied from the referenced
field.
v Packed decimal and binary fields are not supported for printer files. Therefore,
when you reference fields of these types, the data type is converted to zoned
decimal (S in position 35) in the printer file.
Note: Once the printer file is created, the referenced file can be deleted or changed
without affecting the field definitions in the printer file. To incorporate
changes made in the referenced file, delete and re-create the printer file.
412
OS/400 DDS Reference V4R5
.NET PDF Document Viewing, Annotation, Conversion & Processing
Add, edit, delete links. Form Process. Fill in form data programmatically. Document Protect. Apply password to protect PDF. Allow to create digital signature.
convert word form to fillable pdf form; convert word to pdf fillable form
VB.NET PDF Password Library: add, remove, edit PDF file password
3.pdf" Dim outputFilePath As String = Program.RootPath + "\\" 3_pw_a.pdf" ' Create a password setting passwordSetting.IsAnnot = True ' Allow to fill form.
convert pdf to fill in form; add signature field to pdf
DDS Length for printer files (Positions 30 through 34)
Specify the field length for each named field (unless you copy it from a referenced
field). Your entry represents the number of bytes of data to be passed from your
program when an output operation is done for this field. (If the field is to be
edited, the associated edit code or edit word is used to determine the printed
length of the field.) Figure 307 on page 408 shows how to code the field length.
The maximum length of a zoned decimal field is 31. Data description specifications
allow a maximum field length of 32 767 characters. If the field length causes the
field to extend beyond the page size, a warning diagnostic appears. The maximum
length of a single precision floating-point field is 9 digits; the maximum length of a
double precision floating-point field is 17 digits.
If you use a referenced field, override the referenced length by specifying a new
value or by specifying the increase or decrease in length. To increase the length,
specify +n, where n is the increase. To decrease the length, specify −n, where n is
the decrease. For example, an entry of +4 indicates that the field is to be 4 digits
longer than the referenced field. The field length can be overridden without
overriding the decimals.
If you specify length, it must be right-justified; leading zeros are optional.
Figure 308 shows correct and incorrect field-length specifications.
For floating-point fields, 7 positions will be added to the length you specify in
positions 30 through 34. The 7 extra positions are for the significand sign, the
decimal point or comma, the exponent character, the exponent sign, and the
exponent.
In some cases, if you specify a value for length, some keywords specified with the
field in the database file are not included in the printer file. For more information,
see “DDS Reference for printer files (Position 29)” on page 412.
DDS Data Type for printer files (Position 35)
Use this position to specify the data type associated with the field. The valid
entries for this field for a printer file are:
Entry Meaning
S
Zoned decimal
A
Character
F
Floating point
|...+....1....+....2....+....3....+....4....+....5
00010A
FIELD1
7
A
00020A
FIELD2
7
A
00030A
FIELD3
R
+7
Note: FIELD1 shows the field length specified incorrectly. FIELD2 and FIELD3 show the
field length specified correctly.
Figure 308. Correct and Incorrect Field-Length Specifications for Printer Files
Chapter 4. Keywords for Printer Files
413
C# WPF PDF Viewer SDK to annotate PDF document in C#.NET
Select the fill color when drawing oval, rectangle, polygon and irregular shape. Select the line color when drawing annotations on PDF document. Default create.
convert fillable pdf to word fillable form; convert word doc to fillable pdf form
C# PDF Password Library: add, remove, edit PDF file password in C#
3.pdf"; String outputFilePath = Program.RootPath + "\\" 3_pw_a.pdf"; // Create a password setting passwordSetting.IsAnnot = true; // Allow to fill form.
form pdf fillable; convert pdf fill form
L
Date
T
Time
Z
Timestamp
Figure 307 on page 408 shows how to code the data type.
If you do not specify a data type, and do not duplicate one from a referenced field,
the OS/400 program assigns a default value as follows:
v A (character) if the decimal positions (36 and 37) are blank
v S (zoned decimal) if the decimal positions (36 and 37) contain a number in the
range 0 through 31
Notes:
1.
Specify 0 in position 37 to indicate an integer numeric field.
2.
Specify F in position 35 for a single precision floating-point field. Use the
FLTPCN keyword to specify double precision or to change the precision of an
already specified floating-point field.
3.
Afloating-point value consists of five parts: (a) the significand sign, (b) the
significand, (c) the exponent character (d) the exponent sign, and (e) the
exponent.
The significand sign is not printed for a positive value. The number of digits in
the significand is determined by the length specified (positions 30 through 34).
The location of the decimal point or the comma is determined by the decimal
positions specified (positions 36 and 37). The exponent character and the
exponent sign are always printed. The exponent is always 3 digits.
The printed length for a floating-point field is 7 positions greater than the
length specified in positions 30 through 34. The 7 extra positions are for (a) the
significand sign, (b) the decimal point or comma, (c) the exponent character, (d)
the exponent sign, and (e) the 3 exponent digits.
4.
Date, Time, and Timestamp restrictions:
The field length (*DDS positions 30 and 34) for these data types must be blank.
The field length is determined by the following rules:
v For Date (L), the format specified on the DATFMT keyword dictates the
length of the field. If the DATFMT keyword is not specified, then the format
defaults to *ISO, which has a field length of 10.
v For Time (T), the format specified on the TIMFMT keyword dictates the
length of the field. All formats for the TIMFMT keyword, including the
default of *ISO when TIMFMT is not specified, has a field length of 8.
v For Timestamp (Z), the field length is 26.
Fields that specify these data types are treated as alphanumeric data when
printed. It is up to the application program to provide the data in the correct
format and length according to the data type and keywords specified for these
fields.
Blank is the only supported value for decimal positions (DDS positions 36 and
37).
Zero suppression is not supported for these data types. EDTCDE and EDTWRD
keywords are not valid and the &cpf. program does not perform zero
suppression by default as it does for signed-numeric fields.
414
OS/400 DDS Reference V4R5
VB.NET PDF - Annotate PDF with WPF PDF Viewer for VB.NET
Select the fill color when drawing oval, rectangle, polygon and irregular shape. Select the line color when drawing annotations on PDF document. Default create.
change font in pdf fillable form; create a writable pdf form
VB.NET PDF - Annotate PDF Online with VB.NET HTML5 PDF Viewer
Click to create a note to replace selected text add a text box to specific location on PDF page Outline width, outline color, fill color and transparency are all
convert an existing form into a fillable pdf form; convert pdf fillable form to word
The following field level keywords are not allowed with these data types.
BARCODE
FLTFIXDEC
BLKFOLD
FLTPCN
DATE
IGCCDEFNT
DFT
IGCCHRRRT
EDTCDE
MSGCON
EDTWRD
PAGNBR
TIME
DDS Decimal Positions for printer files (Positions 36 and 37)
Use these positions to specify the decimal placement within a zoned decimal field
and the data type of the field as it appears in your program.
If you leave these positions blank, the OS/400 program assumes a data type of
character for the field.
If you enter a number in these positions, the OS/400 program assumes a data type
of zoned decimal for the field. The number specified is the number of positions to
the right of the decimal point; it must be less than or equal to the field length, with
amaximum of 31. Figure 307 on page 408 shows how to code decimal positions.
If you use a referenced field, you do not need to specify decimal positions because
the information is retrieved from the referenced file. You can override or change
the decimal positions retrieved if you choose.
To override the decimal positions, specify the new value. To change the decimal
positions, specify the amount you want to increase or decrease the field by and
precede the amount with either a + or −. For example, an entry of +4 indicates
there are 4 more digits to the right of the decimal point than in the referenced
field.
Note: High-level languages can impose specific length and value restrictions on
the decimal positions. Observe these restrictions for files used by those
languages.
DDS Usage for printer files (Position 38)
Use this position to specify that a named field is an output-only or
program-to-system field. Do not make an entry in this position for a constant
(unnamed) field.
The valid entries for printer files are:
Entry Meaning
blank or O
Output only
P
Program-to-system (special output field)
Output-only fields pass data from a program to the printer when the program
prints a record.
Chapter 4. Keywords for Printer Files
415
C# HTML5 PDF Viewer SDK to annotate PDF document online in C#.NET
Click to create a note to replace selected text add a text box to specific location on PDF page Outline width, outline color, fill color and transparency are all
change font size pdf fillable form; convert word form to fillable pdf
VB.NET PDF Form Data Read library: extract form data from PDF in
RasterEdge .NET PDF SDK is such one provide various of form field edit functions. Demo Code to Retrieve All Form Fields from a PDF File in VB.NET.
convert pdf to form fill; pdf signature field
Aprogram-to-system field is a named, numeric, or alphanumeric output-only field
used to pass data between the program and the system. It is not printed. A
program can send data to the field with an output operation, but the data is not
printed.
The following rules apply to program-to-system fields:
v The field is always named.
v Locations are not valid.
v Length, data type, and decimal positions are specified as for other named fields.
v The program-to-system field must be specified as a parameter on a PAGSEG,
OVERLAY, GDF, LINE, or POSITION keyword within the same record format.
The program-to-system field is not a valid parameter on any other keyword. A
severe error message is issued if the field is not specified on at least one of these
keywords.
v Program-to-system fields can appear anywhere in the buffer.
v The only valid keywords for a program-to-system field are ALIAS, INDTXT,
REFFLD, and TEXT.
DDS Location for printer files (Positions 39 through 44)
Use these positions to specify where the beginning of the field you are defining
appears on the page. You specify the line (positions 39 through 41) and the
position (positions 42 through 44). The following conditions apply:
v When line numbers are specified, fields can appear in any order. They will be
sequenced again into line-position order when placed in the printer file.
v When line numbers are not specified, the field order within the printer file is the
same as that specified in the DDS.
v When fields or space/skip keywords are conditioned, the data description
processor treats them as if they were selected when diagnosing overlapping
fields.
v For a record format with several fields, when a field that has skip/space
keywords is conditioned or a field-level skip/space keyword is conditioned, a
warning message appears indicating that overlapping fields could occur and not
be diagnosed.
v When the page size is exceeded because of field length, location, or associated
skip/space keywords, or because of a combination of these, a warning message
appears.
v The maximum that can be entered for line number is 255. The actual maximum
for the page may be less depending on the page-length value of the PAGESIZE
parameter on the Create Printer file (CRTPRTF) command and on the lines per
inch specified.
v The maximum value that can be entered for position number is 255. The actual
maximum for the page depends on the page-width value of the PAGESIZE
parameter on the Create Printer File (CRTPRTF) command and on the characters
per inch, either specified or implicit in the font being used.
v The overflow line (the last printed line on a page) depends on the values of
OVRFLW and PAGESIZE parameters on the Create Printer File (CRTPRTF),
Change Printer File (CHGPRTF), and Override with Printer File (OVRPRTF)
commands. For externally defined files, RPG cannot control page overflow.
v When externally defined files are used by high-level language compilers, the
fields are sequenced in the output record area according to the DDS. Refer to the
appropriate high-level language manual for specific information. If fields
416
OS/400 DDS Reference V4R5
overlap, the printer overprints. See the expanded source in the compiler printout
generated by the Create Printer File command for field lengths and output
buffer positions.
v These positions must be blank if the POSITION keyword is specified.
DDS Line (Positions 39 through 41)
These positions specify the line on the page in which the field begins. The entry
must be right-justified; leading zeros are optional. Line numbers can be specified
for either named or unnamed fields within a record. If you specify a line number
for one field within a record, you must specify either a line number in positions 39
through 41 or a plus value (+n) in positions 42 through 44 for all fields within that
record.
Line numbers are not valid if one of the skip or space keywords has been specified
at either the record level or field level. Line numbers are valid, however, if one of
the skip keywords has been specified at the file level. (Space keywords are not
valid at the file level.)
DDS Position (Positions 42 through 44)
Specify the starting position of the field. The position you specify is based on the
value of the characters per inch value for the printer file, which is either specified
or implicit in the font being used. If the printer file uses *DEVD for the font, uses a
coded font, or uses a font character set, text fields are positioned using blanks
(x’40’) to position to the desired columns. Non-text fields, such as barcodes are
positioned using an implied value of 10 CPI. If a proportional spaced font is being
used, this could produce columns which do not line up. It is recommended that
the Position keyword be used for this situation. The entry must be right-justified;
leading zeros are optional.
If you specify a location of a field in a record and the field is not ignored, you can
specify the location of subsequent fields within that record by leaving the line
number blank and specifying a plus value (+n) for 42 through 44 (position entry).
The plus value indicates the number of spaces to be left between the end of the
previous field and the beginning of the field you are defining. The plus value must
be in the range of 0 through 99. If you specify a plus value, the line number entry
must be blank. If the plus value causes an implicit space operation, and line
numbers are not being used for the record format, then skip/space keywords must
be used to cause spacing to occur.
The system uses the page width specified on the CRTPRTF command as the width
limit when figuring field positions. For example, a user specifies the page width as
132. If the record format being created uses reference positioning instead of
hard-coded positions, the fields will be wrapped at position 132. If a line number
was specified on a field in the format, the overlapping fields will be wrapped to
the next line. If no line number was specified for the format, the data will be
wrapped over the data at the beginning of that same line.
Once the positions are calculated, the real values are stored and treated as if they
were hard-coded. Therefore, if a field was wrapped and now resides on line 1,
postion 5, that is where the field remains even if the page width is increased using
the CHGPRTF command.
Chapter 4. Keywords for Printer Files
417
Figure 309 illustrates this problem and two possible solutions (for a page width of
132 characters).
If FOLD(*YES) is specified for the CRTPRTF, CHGPRTF, or OVRPRTF command,
any field that extends beyond the end of a line is continued on the next line. The
break occurs at the end of the line but you can cause it to be folded at a blank by
specifying the BLKFOLD keyword. If FOLD(*NO) is in effect, a field that extends
beyond the end of a line is truncated.
The data description specifications determine which fields appear on the same
print line. The data description processor diagnoses overlap at file creation time.
Keywords or fields containing optional keywords are assumed to be selected.
Therefore, no overlap check is made for the cases where the keywords or fields are
not selected. In Figure 310, no fields would overlap unless indicator 01 is on, in
which case F1, F3, and F4 would overlap. A diagnostic is sent for the format
indicating that field selection or conditioning of space/skip keywords can cause
fields to overlap at run time.
On some printers, printer throughput speed is better when fields on the same line
are specified in the DDS in right-to-left order.
|...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
A*
A* POSITION PLUS VALUE CAUSES PRFLD1 TO OVERLAP PRFLD2
A*
A
R PRTOUT
SKIPB(1)
A
PRFLD1
130
1TEXT('START LOC 1,1 END LOC 1,130')
A
PRFLD2
130
+2TEXT('OVERLAPS PRFLD1')
A*
A* SOLUTION 1 TO PREVENT OVERLAP IS TO SPECIFY SPACEA OR SKIPA WITH PRFLD1
A*
OR TO SPECIFY SPACEB OR SKIPB WITH PRFLD2
A*
A
R PRTOUT2
SKIPB(1)
A
PRFLD1A
130
1
A
PRFLD2A
130
+2SPACEB(1)
A*
A* SOLUTION 2 PROVIDES A FUNCTIONAL EQUIVALENT NOT USING SKIP/SPACE
A*
A
R PRTOUT3
A
PRFLD1B
130
1 1
A
PRFLD2B
130
+2
A
Figure 309. Specifying the Line and Position Location
|...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
A*
A* OVERLAPPING FIELDS ONLY IF IND 01 IS ON
A*
A
R REC1
SKIPB(1)
A
F1
1
1
ANO1
F2
1
1SPACEB(1) SPACEA(1)
A
F3
1
1
A
F4
1
1
ANO1
SPACEB(1)
A
Figure 310. Overlapping Fields
418
OS/400 DDS Reference V4R5
DDS Keyword Entries for printer files (Positions 45 through 80)
This section contains the valid keyword entries for defining printer files. The
keywords are entered in positions 45 through 80 (functions). See “DDS Syntax
Rules” on page 4 for a discussion of the general rules for specifying keywords.
The following keywords are valid for printer files:
ALIAS
BARCODE
BLKFOLD
BOX
CDEFNT
CHRID
CHRSIZ
COLOR
CPI
CVTDTA
DATE
DATFMT
DATSEP
DFNCHR
DFT
DLTEDT
DOCIDXTAG
DRAWER
DTASTMCMD
DUPLEX
EDTCDE
EDTWRD
ENDPAGE
ENDPAGGRP
FLTFIXDEC
FLTPCN
FNTCHRSET
FONT
FORCE
GDF
HIGHLIGHT
INDARA
INDTXT
INVDTAMAP
INVMMAP
LINE
LPI
MSGCON
OVERLAY
OUTBIN
PAGNBR
PAGRTT
PAGSEG
POSITION
PRTQLTY
REF
REFFLD
SKIPA
SKIPB
SPACEA
SPACEB
STRPAGGRP
TEXT
TIME
TIMFMT
TIMSEP
TRNSPY
TXTRTT
UNDERLINE
ZFOLD
ALIAS (Alternative Name) Keyword in Printer Files
Use this field-level keyword to specify an alternative name for a field. When the
program is compiled, the alternative name is brought into the program instead of
the DDS field name. The high-level language compiler in use determines if the
alternative name is used. Refer to the appropriate high-level language reference
manual for information about ALIAS support for that language.
The format of the keyword is:
ALIAS(alternative-name)
Refer to the “DDS Syntax Rules” on page 4 for ALIAS naming conventions.
The alternative-name parameter must be different from all other alternative names
and from all DDS field names in the record format. If a duplicate name is found,
an error appears on the field name or alternative name.
An alternative name cannot be used within DDS or any other OS/400 function (for
example, as a key field name, as the field name specified for the REFFLD keyword,
or as a field name used in the Copy File (CPYF) command).
When you reference a field that has the ALIAS keyword, the ALIAS keyword is
copied in unless the ALIAS keyword is explicitly specified on the referencing field.
Option indicators are not valid for this keyword.
Chapter 4. Keywords for Printer Files
419
ALIAS (Alternative Name) Keyword in Printer Files— — Example
Figure 311 shows how to specify the ALIAS keyword.
In Figure 311, the alternative name for FIELDA is CUSTOMERNAME.
BARCODE (Bar Code) Keyword in Printer Files
Use this field-level keyword to print a field as a user-specified bar code.
BARCODE is valid only for Intelligent Printer Data Stream* (IPDS*) printers and
only for printer files with device type *IPDS or *AFPDS specified.
The format of the keyword is:
BARCODE(bar-code-ID [height] [[*HRZ | *VRT]
[*HRI | *HRITOP | *NOHRI] [*AST | *NOAST]
[check-digit] [unit-width]
[wide/narrow-ratio]])
The bar-code-ID parameter is required. Valid values for the bar code ID are listed
in Table 15 on page 421.
The height parameter is optional, but if it is specified, it must be the second
parameter following the keyword. Valid values for the bar code height are 1
through 9 lines. The value you specify for the bar code height does not include the
human readable interpretation below the bar code. If you do not specify the height
parameter, the printer uses a default height.
You can specify the last 6 parameters (all optional) in any order. Using these
parameters, you can specify that BARCODE:
v Print the bar code horizontally or vertically. The default is horizontal printing
(*HRZ).
v Include or exclude the human readable interpretation of the bar code. The
default is to include the human readable interpretation printed at the bottom of
the bar code (*HRI).
v Indicate that the human readable interpretation should be printed at the top
(*HRITOP) of the bar code. (Check individual printer manuals for different bar
code support of *HRITOP.)
v Include or exclude asterisks around the human readable interpretation for
CODE3OF9 barcodes. The default is to exclude the asterisks (*NOAST).
v Select the check digit type. This is a 1-character hex value that cannot be hex FF.
v Specify the width (in inches) of the narrow bar/space. It is specified as an
expression of the form (*WIDTH value). For more information on how to specify
expressions, see “DDS Syntax Rules” on page 4. The valid values for the
parameter are 0.007 through 0.208.
|...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
00070A
FIELDA
25A
1 2ALIAS(CUSTOMERNAME)
A
Figure 311. Specifying the ALIAS Keyword
Printer Files, ALIAS
420
OS/400 DDS Reference V4R5