convert pdf page to image c# itextsharp : Create pdf password application Library utility azure asp.net wpf visual studio FT1A-Ladder-Programming21-part1611

SMARTAXIS LADDER PROGRAMMING MANUAL FT9Y-B1382 
13-15
13: DISPLAY INSTRUCTIONS
Configuring the special data
17.Select the left edge of the fourth line and click Special Data.
The Special Data List window is poped up.
18.Double-click on the Current date.
19.After the settings are configured, click OK.
The configured content is displayed on the LCD screen area.
This concludes configuring the settings.
LCD display
20
12
/
0
3
1
/
0
IDE C r oom  tem p is
Now:
28°C
20
12
/
0
3
1
/
0
IDE C ro om te mp i s
Now :
20
12
/
0
3
1
/
0
IDE C ou td oo r te mp i s
28° C
No w:
-5° C
When M0000 is on, the room temperature stored in D0002
is displayed as the numeric value (°C) and bar graph.
When M0000 is off, the outdoor temperature stored in D0002
is displayed as the numeric value (°C) and bar graph.
Create pdf password - C# PDF Password Library: add, remove, edit PDF file password in C#.net, ASP.NET, MVC, WinForms, WPF
Help to Improve the Security of Your PDF Document by Setting Password
protected pdf; break pdf password
Create pdf password - VB.NET PDF Password Library: add, remove, edit PDF file password in vb.net, ASP.NET, MVC, WinForms, WPF
Help to Improve the Security of Your PDF Document by Setting Password
pdf password encryption; crystal report to pdf with password
13: DISPLAY INSTRUCTIONS
13-16
SMARTAXIS LADDER PROGRAMMING MANUAL FT9Y-B1382 
Modifying Device Values on the SmartAXIS
The values of the word devices displayed on the SmartAXIS LCD can be modified using the SmartAXIS operation buttons.
The values cannot be modified when the SmartAXIS is stopped.
[To modify the value of word device CP0]
When the SmartAXIS is running and the input to the MSG instruction is turned on, the following screen will be displayed on the 
LCD.
While the above message is displayed, press and hold the   (OK) button and the cursor is displayed on the devices that can be 
modified.
Move the cursor to the device you wish to edit using the   (up)   (down)   (left)   (right) buttons and press and hold the   
(OK) button to change the device in the editable state.
Press the   (right) button to move the cursor to the fourth digit, and then use the   (up) button to modify the target value to 
"65000".
Press the   (OK) button to confirm the modifications.
Line A monitor
Plan: CPO   Actual:CCO
Diff: DO
Bar Graph CC0
Line A monitor
Plan: 60000 Actual:20000
Diff: 40000
Line A monitor
Line A monitor
Diff: 40000
Plan: 60000 Actual:20000
Line A monitor
Diff: 40000
Plan: 60000 Actual:20000
6
Line A monitor
Diff: 40000
Plan: 65000 Actual:20000
Line A monitor
Line A monitor
Diff: 40000
Plan: 65000 Actual:20000
VB.NET Create PDF from PowerPoint Library to convert pptx, ppt to
Protect. Password: Set File Permissions. Password: Open Document. Add Text Box. Drawing Markups. PDF Print. Work Barcode Read. Barcode Create. OCR. Twain. Create
pdf user password; pdf passwords
VB.NET Create PDF from Word Library to convert docx, doc to PDF in
Protect. Password: Set File Permissions. Password: Open Document. Add Text Box. Drawing Markups. PDF Print. Work Barcode Read. Barcode Create. OCR. Twain. Create
change password on pdf; break pdf password online
SMARTAXIS LADDER PROGRAMMING MANUAL FT9Y-B1382 
13-17
13: DISPLAY INSTRUCTIONS
Scrolling text example
[Character Set: European scroll speed: 500 ms]
When a text with effect is set to scroll, the text is displayed on the SmartAXIS LCD as follows.
When scrolling a text longer than the specified area on 
the LCD
Text:  "IDEC Corporation SmartAXIS"
When scrolling a text shorter than or equal to the 
specified area on the LCD
Text:  "IDEC Corp. SmartAXIS"
500 msec
500 msec
500 msec
500 msec
500 msec
500 msec
500 msec
500 msec
500 msec
500 msec
500 msec
500 msec
IDEC Corporation SmartAXIS
・・・
IDEC Corporation SmartAXIS
ion SmartAXIS
on SmartAXIS
IDEC Corpor
IDEC Corpora
IDEC Corporat
IDEC Corporati
IDEC Corporation SmartAXIS
IDEC Corporation SmartAXIS
IDEC Corporation SmartAXIS
IDEC Corporation SmartAXIS
IDEC Corporation SmartAXIS
500 msec
500 msec
500 msec
500 msec
500 msec
500 msec
・・・
IDEC Corp. SmartAXIS
DEC Corp. SmartAXIS
I
EC Corp. SmartAXIS
ID
C Corp. SmartAXIS
IDE
Corp. SmartAXIS
IDEC
Corp. SmartAXIS
IDEC 
orp. SmartAXIS
IDEC C
VB.NET Create PDF from Excel Library to convert xlsx, xls to PDF
Protect. Password: Set File Permissions. Password: Open Document. Add Text Box. Drawing Markups. PDF Print. Work Barcode Read. Barcode Create. OCR. Twain. Create
pdf open password; create pdf password
Online Remove password from protected PDF file
Online Remove Password from Protected PDF file. Download Free Trial. Remove password from protected PDF file. Find your password-protected PDF and upload it.
pdf password reset; pdf password unlock
13: DISPLAY INSTRUCTIONS
13-18
SMARTAXIS LADDER PROGRAMMING MANUAL FT9Y-B1382 
[Character Set: European, Scroll speed: 500 ms, Scroll unit: 1-dot]
When a text with effect is set to scroll, the text is displayed on the LCD of the SmartAXIS as follows.
Text: "IDEC Corporation SmartAXIS"
62.5 msec
62.5 msec
62.5 msec
62.5 msec
62.5 msec
62.5 msec
62.5 msec
62.5 msec
1 character (8 dots)  is scrolled in 500 ms
62.5 msec
1
2
3
4
5
6
7
8
9
100
111
122
133
144
155
166
1
2
12 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
12 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 55 6 7 8 1 2
56 7 8 1 2
12
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
IDEC Corporation.
C# Create PDF from Tiff Library to convert tif images to PDF in C#
Create PDF from Tiff. |. Home ›› XDoc.PDF ›› C# PDF: Create PDF from Tiff. Create PDF from Tiff in both .NET WinForms and ASP.NET application.
create password protected pdf from word; copy text from protected pdf
VB.NET PDF Convert to Tiff SDK: Convert PDF to tiff images in vb.
Qualified Tiff files are exported with high resolution in VB.NET. Create multipage Tiff image files from PDF in VB.NET project. Support
acrobat password protect pdf; convert protected pdf to word
SMARTAXIS LADDER PROGRAMMING MANUAL FT9Y-B1382
14-1
14:PROGRAM BRANCHING INSTRUCTIONS
Introduction
The program branching instructions reduce execution time by making it possible to bypass portions of the program whenever 
certain conditions are not satisfied.
The basic program branching instructions are LABEL and LJMP, which are used to tag an address and jump to the address which 
has been tagged. Programming tools include “either/or” options between numerous portions of a program and the ability to call 
one of several subroutines which return execution to where the normal program stopped.
LABEL (Label)
Applicable SmartAXIS
Valid Devices
LJMP (Label Jump)
Applicable SmartAXIS
Valid Devices
For valid device address ranges, see "Device Addresses" on page 3-1.
Since the LJMP instruction is executed in each scan while input is on, a pulse input from a SOTU or SOTD instruction should be used.
Note: Make sure that a LABEL instruction of the label number used for a LJMP instruction is programmed. When designating S1 using other than a 
constant, the value for the label is a variable. When using a variable for a label, make sure that all probable LABEL numbers are included in the user 
program. If a matching label does not exist, a user program execution error will result, turning on special internal relay M8004 and the ERR LED on 
the SmartAXIS. For details about the user program execution errors, see "User Program Execution Errors" on page 4-13.
This is the label number, from 0 to 255, used at the program address where the execution of program instructions 
begins for a program branch.
An END instruction may be used to separate a tagged portion of the program from the main program. In this way, scan 
time is minimized by 
not
executing the program branch unless input conditions are satisfied.
Note: A single label number cannot be used more than once.
LABEL
***
FT1A-12
FT1A-24
FT1A-40
FT1A-40
FT1A-Touch
X
X
X
X
X
Device
Function
I
Q
M
R
T
C
D
Constant
Repeat
Label number
Tag for LJMP and LCAL
0-255
When input is on, jump to the address with label 0 through 255 assigned by S1.
When input is off, no jump takes place, and program execution proceeds with the next instruction.
The LJMP instruction is used as an “either/or” choice between two portions of a program. Program 
execution does 
not
return to the instruction following the LJMP instruction, after the program branch.
LJMP
S1
*****
FT1A-12
FT1A-24
FT1A-40
FT1A-48
FT1A-Touch
X
X
X
X
X
Device
Function
I
Q
M
R
T
C
D
Constant
Repeat
S1 (Source 1)
Label number
X
0-255
C# Create PDF from Excel Library to convert xlsx, xls to PDF in C#
C#.NET PDF SDK- Create PDF from Word in Visual C#. Online C#.NET Tutorial for Create PDF from Microsoft Office Excel Spreadsheet Using .NET XDoc.PDF Library.
pdf password security; protected pdf
C# Create PDF from PowerPoint Library to convert pptx, ppt to PDF
C#.NET PDF SDK- Create PDF from PowerPoint in C#. How to Use C#.NET PDF Control to Create PDF from Microsoft PowerPoint Presentation in .NET Project.
copy protected pdf to word converter online; convert password protected pdf to normal pdf online
14: PROGRAM BRANCHING INSTRUCTIONS
14-2
SMARTAXIS LADDER PROGRAMMING MANUAL FT9Y-B1382
Example: LJMP and LABEL
The following example demonstrates a program that jumps to three different portions of the program depending on the input.
Using the Timer Instruction with Program Branching
When the timer start input of the TML, TIM, TMH or TMS instruction is already on, countdown begins immediately at the location 
jumped to, starting with the timer current value. When using a program branch, it is important to make sure that timers are 
initialized when desired, after the jump. If it is necessary to initialize the timer instruction (set to the preset value) after the jump, 
the timer’s start input should be kept off for one or more scan cycles before initialization. Otherwise, the timer input on will not be 
recognized.
Using the SOTU/SOTD Instructions with Program Branching
Check that pulse inputs of counters and shift registers, and inputs of single outputs (SOTU and SOTD) are maintained during the 
jump, if required. Hold the input off for one or more scan cycles after the jump for the rising or falling edge transition to be 
recognized.
LABEL
0
I0
LJMP
S1
0
END
I1
LJMP
S1
1
I2
LJMP
S1
2
M8121
END
M8122
END
M8123
END
Q0
Q1
Q2
LABEL
1
LABEL
2
When input I0 is on, program execution jumps to label 0.
When input I1 is on, program execution jumps to label 1.
When input I2 is on, program execution jumps to label 2.
M8121 is the 1-sec clock special internal relay.
When jump occurs to label 0, output Q0 oscillates in 1-sec increments.
M8122 is the 100-ms clock special internal relay.
When jump occurs to label 1, output Q1 oscillates in 100-ms increments.
M8123 is the 10-ms clock special internal relay.
When jump occurs to label 2, output Q2 oscillates in 10-ms increments.
Although normally, the SOTU instruction produces a pulse for 
one scan, when used in a program branch the SOTU pulse will 
last only until the next time the same SOTU instruction is 
executed.
In the example on the left, the program branch will loop as long 
as internal relay M0 remains on. However, the SOTU produces a 
pulse output only during the first loop.
Since the END instruction is not executed as long as M0 remains on, output Q1 is not turned on even if input I1 is on.
I1
SOTU
M0
LJMP
S1
0
Q1
LABEL
0
Q1 Internal
ON
OFF
Q1 Output
ON
OFF
Memory
END
END
SMARTAXIS LADDER PROGRAMMING MANUAL FT9Y-B1382
14-3
14: PROGRAM BRANCHING INSTRUCTIONS
LCAL (Label Call)
Applicable SmartAXIS
Valid Devices
For valid device address ranges, see "Device Addresses" on page 3-1.
Since the LCAL instruction is executed in each scan while input is on, a pulse input from a SOTU or SOTD instruction should be used.
Note: Make sure that a LABEL instruction of the label number used for a LCAL instruction is programmed. When designating S1 using other than a 
constant, the value for the label is a variable. When using a variable for a label, make sure that all probable LABEL numbers are included in the user 
program. If a matching label does not exist, a user program execution error will result, turning on special internal relay M8004 and the ERR LED on 
the SmartAXIS.
LRET (Label Return)
Applicable SmartAXIS
Valid Devices
When input is on, the address with label 0 through 255 assigned by S1 is called. When input is off, no call 
takes place, and program execution proceeds with the next instruction.
The LCAL instruction calls a subroutine, and returns to the main program after the branch is executed. A 
LRET instruction (see below) must be placed at the end of a program branch which is called, so that normal 
program execution resumes by returning to the instruction following the LCAL instruction.
Note: The END instruction must be used to separate the main program from any subroutines called by the 
LCAL instruction.
A maximum of four LCAL instructions can be nested. When more than four LCAL instructions are nested, a 
user program execution error will result, turning on special internal relay M8004 and the ERR LED on the 
SmartAXIS.
LCAL
S1
*****
FT1A-12
FT1A-24
FT1A-40
FT1A-48
FT1A-Touch
X
X
X
X
X
Device
Function
I
Q
M
R
T
C
D
Constant
Repeat
S1 (Source 1)
Label number to call
X
0-255
This instruction is placed at the end of a subroutine called by the LCAL instruction. When the subroutine is completed, 
normal program execution resumes by returning to the instruction following the LCAL instruction.
The LRET must be placed at the end of the subroutine starting with a LABEL instruction. When the LRET is programmed 
at other places, a user program execution error will result, turning on special internal relay M8004 and the ERR LED on 
the SmartAXIS.
LRET
FT1A-12
FT1A-24
FT1A-40
FT1A-48
FT1A-Touch
X
X
X
X
X
Device
Function
I
Q
M
R
T
C
D
Constant
Repeat
14: PROGRAM BRANCHING INSTRUCTIONS
14-4
SMARTAXIS LADDER PROGRAMMING MANUAL FT9Y-B1382
Correct Structure for Calling Subroutine
When a LCAL instruction is executed, the remaining program instructions on the same rung may not be executed upon return, if 
input conditions are changed by the subroutine. After the LRET instruction of a subroutine, program execution begins with the 
instruction following the LCAL instruction, depending on current input condition.
When instructions following a LCAL instruction must be executed after the subroutine is called, make sure the subroutine does not 
change input conditions unfavorably. In addition, include subsequent instructions in a new ladder line, separated from the LCAL 
instruction.
Example: LCAL and LRET
The following example demonstrates a program that calls three different portions of program depending on the input. When the 
subroutine is complete, program execution returns to the instruction following the LCAL instruction.
I0
LCAL
S1
0
REP
S1 –
D0
D1 –
D1
MOV(W)
REP
S1 –
D20
D1 –
D21
MOV(W)
Correct
I0
LCAL
S1
0
REP
S1 –
D0
D1 –
D1
MOV(W)
REP
S1 –
D20
D1 –
D21
MOV(W)
Incorrect
Separate the ladder line for each LCAL instruction.
I0 status may be changed by the subroutine upon return.
M0
S
M0
S
I0
I0
LCAL
S1
0
END
I1
LCAL
S1
1
I2
LCAL
S1
2
M8121
LRET
M8122
LRET
M8123
LRET
Q0
Q1
Q2
LABEL
0
LABEL
1
LABEL
2
When input I0 is on, program execution jumps to label 0.
When input I1 is on, program execution jumps to label 1.
When input I2 is on, program execution jumps to label 2.
M8121 is the 1-sec clock special internal relay.
When jump occurs to label 0, output Q0 oscillates in 1-sec increments.
Program execution returns to the address of input I1.
M8122 is the 100-ms clock special internal relay.
When jump occurs to label 1, output Q1 oscillates in 100-ms increments.
Program execution returns to the address of input I2.
M8123 is the 10-ms clock special internal relay.
When jump occurs to label 2, output Q2 oscillates in 10-ms increments.
Program execution returns to the address of END.
SMARTAXIS LADDER PROGRAMMING MANUAL FT9Y-B1382
14-5
14: PROGRAM BRANCHING INSTRUCTIONS
DJNZ (Decrement Jump Non-zero)
Applicable SmartAXIS
Valid Devices
For valid device address ranges, see "Device Addresses" on page 3-1.
Since the DJNZ instruction is executed in each scan while input is on, a pulse input from a SOTU or SOTD instruction should be used.
The label number can be 0 through 255. Make sure that a LABEL instruction of the label number used for a DJNZ instruction is programmed. When 
designating S2 using a data register, the value for the label is a variable. When using a variable for a label, make sure that all probable LABEL 
numbers are included in the user program. If a matching label does not exist, a user program execution error will result, turning on special internal 
relay M8004 and the ERR LED on the SmartAXIS.
When input is on, the value stored in the data register assigned by S1 is decremented by one and 
is checked. If the resultant value is not 0, program execution jumps to address with label 0 
through 255 assigned by S2. If the decrement results in 0, no jump takes place, and program 
execution proceeds with the next instruction.
DJNZ
S1
*****
S2
*****
FT1A-12
FT1A-24
FT1A-40
FT1A-48
FT1A-Touch
X
X
X
X
X
Device
Function
I
Q
M
R
T
C
D
Constant
Repeat
S1 (Source 1)
Decrement value
X
S2 (Source 2)
Label number to jump to
X
0-255
14: PROGRAM BRANCHING INSTRUCTIONS
14-6
SMARTAXIS LADDER PROGRAMMING MANUAL FT9Y-B1382
Example: DJNZ and LABEL
The following example demonstrates a program to store consecutive values 1000 through 1049 to data registers D100 through 
D149, respectively.
LABEL
255
M8120
END
M8120
REP
S1 –
D0
D1 –
D99
IMOV(W)
S2
D2
D1
REP
S1 –
1049
D1 –
D0
MOV(W)
REP
S1 –
50
D1 –
D1
MOV(W)
S/D
D0
DEC(W)
S2
255
S1
D1
DJNZ
M8120 is the initialize pulse special internal relay.
At start-up, MOV instructions store initial data.
1049  D0 to store the value for the first cycle.
50  D1 to determine the jump cycles.
IMOV moves D0 data 1049 to D1049 in the first cycle.
DEC decrements D0 data to 1048.
DJNZ jumps to label 255 until D1 value reduces to 0.
1049
D0
Destination: D99 + 50 = D149
1049
D149
50
D1
1st cycle:
1048
D0
Destination: D99 + 49 = D148
1048
D148
49
D1
2nd cycle:
1047
D0
Destination: D99 + 48 = D147
1047
D147
48
D1
3rd cycle:
1046
D0
Destination: D99 + 47 = D146
1046
D146
47
D1
4th cycle:
1001
D0
Destination: D99 + 2 = D101
1001
D101
2
D1
49th cycle:
1000
D0
Destination: D99 + 1 = D100
1000
D100
1
D1
50th cycle:
Documents you may be interested