c# convert pdf to tiff : Add jpg signature to pdf Library application class asp.net windows wpf ajax OpenCOBOL%20Programmers%20Guide9-part44

OpenCOBOL 1.1 Programmers Guide 
PROCEDURE DIVISION 
06FEB2009 Version 
Page 6-31 
6.5.
ADD 
6.5.1.
ADD Format 1 – ADD TO 
Figure 6-26 - ADD (TO) Syntax 
This format of the ADD statement generates 
the arithmetic sum of all arguments that 
appear before
the TO (identifier-1 or literal-1) 
and then adds that sum to each of the 
identifiers listed after
the TO (identifier-2). 
1.
Identifier-1 and identifier-2 must be numeric unedited data items. 
2.
Literal-1 must be a numeric literal. 
3.
Should a non-integer result be generated and assigned to any of the identifier-2 data items that have the optional 
ROUNDED keyword, the result saved into identifier-2 will be rounded according to the standard mathematical 
rules for rounding values to the least-significant digit of precision.  For example, if the PICTURE is 99V99 and the 
result to be saved is 12.152, the saved value will be 12.15 whereas a result of 76.165 would save a value of 76.17. 
4.
If the optional LENGTH OF clause is used on any literal-1 or identifier-1, the arithmetic value used during the 
computation process will be the length – in bytes – of the data item or literal, not the actual value of that data 
item or literal. 
5.
The optional ON SIZE ERROR clause allows you 
to specify code that will be executed if the 
result to be saved into an identifier-2 item 
exceeds the capacity of that item.  For 
example, if the PICTURE is 99V99 and the result 
to be saved is 101.43, a SIZE ERROR condition 
would exist.  Without an ON SIZE ERROR 
clause, OpenCOBOL will store a value of 01.43 
into the field.  With an ON SIZE ERROR clause, 
the value of the identifier-2 item will be 
unchanged and imperative-statatement-1 will 
be executed.  As an illustration, observe the 
small demo program and output shown here.  
It also illustrates some of the ͞EX EPTION͟ 
intrinsic functions (see section 6.1.7
). 
Figure 6-27 - A Sample Program Using ON SIZE ERROR 
6.
The NOT ON SIZE ERROR clause, if specified, will execute an imperative statement if the ADD statement did not
encounter a field size overflow condition. 
ADD
[ LENGTH
OF ]
literal-1
identifier-1
...
TO
{ identifier-2 [ ROUNDED
] } ...
[ ON SIZE
ERROR
imperative-statement-1]
[ NOT
ON SIZE
ERROR
imperative-statement-2 ]
[ END-ADD
]
1.       IDENTIFICATION DIVISION.
2.       PROGRAM-ID. corrdemo.
3.       DATA DIVISION.
4.       WORKING-STORAGE SECTION.
5.       01  Item-1       VALUE 1          PIC 99V99.
6.       PROCEDURE DIVISION.
7.       100-Main SECTION.
8.       P1.
9.           ADD 19 81.43 TO Item-1 
10.               ON SIZE ERROR
11.                   DISPLAY 'Item-1:' Item-1
12.                   DISPLAY 'Error: ' FUNCTION EXCEPTION-STATUS
13.                   DISPLAY 'Where: ' FUNCTION EXCEPTION-LOCATION
14.                   DISPLAY ' What: ' FUNCTION EXCEPTION-STATEMENT
15.           END-ADD.
16.
STOP RUN.
When executed, the program produces the following output:
Item-1:0100
Error: EC-SIZE-OVERFLOW
Where: corrdemo; P1 OF 100-Main; 9
What: ADD
Add jpg signature to pdf - C# PDF File Permission Library: add, remove, update PDF file permission in C#.net, ASP.NET, MVC, WPF
Tell C# users how to set PDF file permissions, like printing, copying, modifying, extracting, annotating, form filling, etc
add jpg signature to pdf; export pdf sign in
Add jpg signature to pdf - VB.NET PDF File Permission Library: add, remove, update PDF file permission in vb.net, ASP.NET, MVC, WPF
VB.NET Tutorial for How to Set PDF File Access Permissions Using XDoc.PDF for .NET
add signature to pdf reader; add signature image to pdf acrobat
OpenCOBOL 1.1 Programmers Guide 
PROCEDURE DIVISION 
06FEB2009 Version 
Page 6-32 
6.5.2.
ADD Format 2 – ADD GIVING 
Figure 6-28 - ADD (GIVING) Syntax 
This format of the ADD statement generates 
the arithmetic sum of all arguments that 
appear before
the TO (identifier-1 or literal-
1), adds that sum to the contents of 
identifier-2 (if any) and then replaces the 
contents of the identifiers listed after
the 
GIVING (identifier-3) with that sum. 
1.
Identifier-1 and identifier-2 must be numeric unedited data items. 
2.
Identifier-3 must be a numeric (edited or unedited) data item. 
3.
Literal-1 must be a numeric literal. 
4.
The contents of identifier-2 are not altered. 
5.
The use and behavior of the ROUNDED, LENGTH OF, ON SIZE ERROR and NOT ON SIZE ERROR clauses is as 
described in section 6.5.1 
for Format 1 of the ADD statement. 
6.5.3.
ADD Format 3 – ADD CORRESPONDING 
Figure 6-29 - ADD (CORRESPONDING) Syntax 
This format of the ADD statement 
generates code equivalent to 
individual ADD TO statements for 
corresponding matches of data 
items found subordinate to the two 
identifiers. 
1.
The rules for identifying corresponding matches are as discussed in section 6.28.2
– MOVE CORRESPONDING. 
2.
The use and behavior of the ROUNDED, ON SIZE ERROR and NOT ON SIZE ERROR clauses is as described in section 
6.5.1
for Format 1 of the ADD statement. 
ADD
[ LENGTH
OF ]
literal-1
identifier-1
...
[ TO
identifier-2 ]
[ ON SIZE
ERROR
imperative-statement-1 ]
[ NOT
ON SIZE
ERROR
imperative-statement-2 ]
[ END-ADD
]
GIVING
{identifier-3 [ ROUNDED
] }...
ADD
CORR
ESPONDING identifier-1 TO
identifier-2 [ ROUNDED
]
[ ON SIZE
ERROR
imperative-statement-1]
[ NOT
ON SIZE
ERROR
imperative-statement-2 ]
[ END-ADD
]
C# PDF insert image Library: insert images into PDF in C#.net, ASP
Add multiple images to multipage PDF document in .NET image formats, like Jpeg or Jpg, Png, Gif Import graphic picture, digital photo, signature and logo into
adding signature to pdf file; create pdf with signature field
JPG to JBIG2 Converter | Convert JPEG to JBIG2, Convert JBIG2 to
original images without any affecting; Ability to convert image swiftly between JPG & JBIG2 in Also can be used as add-on for RasterEdge .NET Imaging SDK. Start
add signature to pdf; pdf sign in
OpenCOBOL 1.1 Programmers Guide 
PROCEDURE DIVISION 
06FEB2009 Version 
Page 6-33 
6.6.
ALLOCATE 
Figure 6-30 - ALLOCATE Syntax 
The ALLOCATE statement is used to dynamically allocate 
memory at run-time. 
1.
If used, expression-1 must be an arithmetic expression with a non-zero positive integer value.  To avoid confusing 
the 06FE 2009 version of the syntax parser when using the ͞expression-1  HARA TERS͟ option, enclose the 
expression in parenthesis so it cannot be mistaken for the ͞identifier-1͟ option.  This possibility of parser 
͞confusion͟ will be corrected in a future Open O OL 1.1 tarball. 
2.
If used, identifier-1 should be an 01-level item defined with the BASED attribute in WORKING-STORAGE or LOCAL-
STORAGE.  It can
be an 01 item defined in the LINKAGE SECTION, but using such a data item is not
recommended. 
3.
If used, identifier-2 should be a USAGE POINTER data item. 
4.
The optional RETURNING clause will return the address of the allocated memory block into the specified USAGE 
POINTER item.  When this option is used, OpenCOBOL will retain knowledge of the originally-requested size of the 
allocated memory block in case a FREE (section 6.19
) statement is ever issued against that USAGE POINTER item. 
5.
When the ͞identifier-1͟ option is used, INITIALIZE will initialize the allocated memory block according to the 
PICTURE and (if any) VALUE clauses present in the definition of identifier-1 as if a INITIALIZE identifier-1 WITH 
FILLER ALL TO VALUE THEN TO DEFAULT were executed once identifier-1 was allocated. See section 6.24 for a 
discussion of the INITIALIZE statement. 
6.
When the ͞expression-1  HARA TERS͟ option is used, INITIALIZE will initialize the allocated memory block to 
binary zeros. 
7.
If the INITIALIZE clause is not used, the initial contents of allocated memory will be left to whatever rules of 
memory allocation are in effect for the operating system the program is running under. 
8.
There are two basic ways in which this statement is used.  The simplest is: 
ALLOCATE My-01-Item  
With this form, a block of storage equal in size to the defined size of My-01-Item (which must have been defined 
with the BASED attribute) will be allocated.  The address of that block of storage will become the base address of 
My-01-Item so that it and its subordinate data items become usable within the program.   
A second (and equivalent) approach is: 
ALLOCATE LENGTH OF My-01-Item CHARACTERS RETURNING The-Pointer. 
SET ADDRESS OF My-01-Item TO The-Pointer. 
With this form, the ALLOCATE statements allocates a block of memory exactly the size as would be needed for 
My-01-Item; that address is returned into a pointer variable.  The SET statement then ͞bases͟ the address of My-
01-Item to be the address of the memory block created by the ALLOCATE. 
The only real functional difference between these two approaches is that – with the first – the INITIALIZED clause, 
if any, will be honored. 
9.
Referencing a BASED data item either before its storage has been ALLOCATEd or after its storage has been FREEd 
will lead to unpredictable results
23
23
The  O OL standards like to use the term ͞unpredictable results͟ to indicate any sort of unexpected or undesirable 
behavior – the results in this case probably are predictable though – the program will probably abort from 
attempting to access an invalid address. 
ALLOCATE
[ INITIALIZED
]
[ RETURNING
identifier-2]
expression-1CHARACTERS
identifier-1
JPEG Image Viewer| What is JPEG
JPEG, JPG. excluded in the standard RasterEdge .NET Imaging SDK, you may add it on images into other file formats, including Bitmap, Png, Gif, Tiff, PDF, MS-Word
sign pdf; add signature pdf online
VB.NET PDF insert image library: insert images into PDF in vb.net
various image formats, like Jpeg or Jpg, Png, Gif Import graphic picture, digital photo, signature and logo into PDF Add images to any selected PDF page in VB
add signature box to pdf; adding signature to pdf
OpenCOBOL 1.1 Programmers Guide 
PROCEDURE DIVISION 
06FEB2009 Version 
Page 6-34 
6.7.
CALL 
Figure 6-31 - CALL Syntax 
The CALL 
statement is 
used to transfer 
control to 
another 
program, called a 
subprogram or 
subroutine.   
1.
The expectation is that the subprogram will eventually return control back to the CALLing program, at which point 
the CALLing program will resume execution starting with the statement immediately following the CALL.  
Subprograms are not required to return to their CALLers, however, and are free to halt program execution if they 
wish. 
2.
The EXCEPTION and OVERFLOW keywords may be used interchangeably. 
3.
The RETURNING and GIVING keywords may be used interchangeably. 
4.
The value of literal-1 or identifier-1 is the entry-point of the subprogram you wish to CALL.  See sections 7.1.4
and 
7.1.5
for more information on how this entry-point is used. 
5.
When you CALL a subroutine using identifier-1, you are forcing the runtime system to call a dynamically-loadable 
module.  See section 7.1.4
for information on dynamically-loadable modules. 
6.
The optional ON EXCEPTION clause specifies code to be executed should the loading of a dynamically-loadable 
module fail.  By specifying ON EXCEPTION, the default behavior of generating an error message and halting the 
program will be overridden – replaced by whatever logic you specify. 
7.
The optional NOT ON EXCEPTION clause specifies code to be executed should the loading of a dynamically-
loadable module succeed. 
8.
The USING clause defines a list of arguments that may be passed from the CALLing program to the subprogram.  
The manner in which the arguments are passed depends upon the BY clause. 
9.
If the subprogram being CALLed is an OpenCOBOL program, and if that program had the INITIAL attribute 
specified on its PROGRAM-ID clause, all of the subprogram͛s DATA DIVISION data will be restored to its initial 
state each time the subprogram is executed
24
.  This [re]-initialization behavior will always
apply to any data 
defined in the subprogram͛s LO AL-STORAGE SECTION (if any), regardless of the use (or not) of INITIAL. 
24
This is regardless of which entry-point within the subprogram is CALLed 
CALL
identifier-1
literal-1
USING
BY
REFERENCE
CONTENT
VALUE
SIZE
IS AUTO
SIZE
IS DEFAULT
UNSIGNED
SIZE
IS integer
identifier-2
literal-2
OMITTED
...
EXCEPTION
OVERFLOW
ON
imperative-statement-1
RETURNING
GIVING
Identifier-3
[ END-CALL
]
EXCEPTION
OVERFLOW
NOT
ON
imperative-statement-2
XDoc.HTML5 Viewer for .NET, All Mature Features Introductions
and Communications in Medicine; Raster Image Files: BMP, GIF, JPG, PNG, JBIG2PDF NET document and image viewer allows users to add various annotations Signature.
create signature pdf; export pdf to word sign in
VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
Create image files including all PDF contents, like watermark and signature. Convert PDF to Jpg, Png, Bmp, Gif, Tiff and Bitmap in ASP Add necessary references:
add signature to preview pdf; create pdf signature stamp
OpenCOBOL 1.1 Programmers Guide 
PROCEDURE DIVISION 
06FEB2009 Version 
Page 6-35 
10.
BY REFERENCE (the default) 
passes the address of the 
argument to the 
subprogram and will allow 
the subprogram to change 
that arguments value.  This 
can be dangerous when 
passing a literal value as an 
argument.   
11.
BY CONTENT passes the 
address of a copy of the 
argument to the 
subprogram.  If the 
subprogram changes the 
value of such an argument, 
the original version of it 
back in the CALLing program 
remains unchanged.  
Clearly, as Figure 6-32
shows, this is the safest way 
to pass literal values to a 
subprogram. 
Figure 6-32 - CALL BY REFERENCE Can Sometimes have Unwanted Effects! 
12.
BY VALUE passes the address
of the argument 
as the argument.  Check out the coding 
example in Figure 6-33
.  Why would you want 
this?  The answer is simple – if the subprogram 
is written in OpenCOBOL, you probably 
wouldn͛t!  This feature exists to provide 
compatibility with C, C++ and other languages. 
13.
The RETURNING clause allows you to specify a 
data item into which the subroutine should 
return a value.  If you use this clause on the 
CALL, the subroutine should include a 
RETURNING clause on its PROCEDURE 
DIVISION header.  Of course, a subroutine may 
pass a value back in ANY argument passed BY 
REFERENCE. 
14.
For additional information, see sections 6.8
(CANCEL), 6.16
(ENTRY), 6.18
(EXIT) and 6.21
(GOBACK). 
Figure 6-33 - CALL BY VALUE 
IDENTIFICATION DIVISION.
PROGRAM-ID. testbed.
ENVIRONMENT DIVISION.
DATA DIVISION.
PROCEDURE DIVISION.
000-Main.
DISPLAY "MAIN (Before CALL): lit=" "lit".
CALL "testsub" USING BY REFERENCE "lit".
DISPLAY "MAIN (After CALL) : lit=" "lit".
STOP RUN.
IDENTIFICATION DIVISION.
PROGRAM-ID. testsub.
ENVIRONMENT DIVISION.
DATA DIVISION.
LINKAGE SECTION.
01  Arg1               PIC X(3).
PROCEDURE DIVISION USING Arg1.
000-Main.
MOVE 'XXX' TO Arg1.
EXIT PROGRAM.
END PROGRAM testsub.
END PROGRAM testbed.
This program and subprogram…
Produce this
output…
Since the literal 
was passed BY 
REFERENCE, it 
was actually 
changed!
MAIN (Before CALL): lit=lit
MAIN (After CALL) : lit=XXX
IDENTIFICATION DIVISION.
PROGRAM-ID. testbed.
ENVIRONMENT DIVISION.
DATA DIVISION.
WORKING-STORAGE SECTION.
01  Item USAGE BINARY-LONG VALUE 256.
PROCEDURE DIVISION.
000-Main.
CALL "testsub1" 
USING BY CONTENT "lit", 
BY VALUE   Item.
STOP RUN.
END PROGRAM testbed.
IDENTIFICATION DIVISION.
PROGRAM-ID. testsub1.
ENVIRONMENT DIVISION.
DATA DIVISION.
WORKING-STORAGE SECTION.
01  The-Pointer        USAGE POINTER.
LINKAGE SECTION.
01  Arg1               PIC X(3).
01  Arg2               PIC X(4).
PROCEDURE DIVISION USING Arg1, Arg2.
000-Main.
SET The-Pointer TO ADDRESS OF Arg2.
DISPLAY "Arg1=" Arg1. 
DISPLAY " The-Pointer=" The-Pointer.
EXIT PROGRAM.
END PROGRAM testsub1.
This program and subprogram…
Produce this
output…
Arg1=lit
The-Pointer=0x00000100
JPEG to PDF Converter | Convert JPEG to PDF, Convert PDF to JPEG
similar software; Support a batch conversion of JPG to PDF with amazingly high speed; Get a compressed PDF file after conversion; Support
create pdf signature; add signature block to pdf
JPG to DICOM Converter | Convert JPEG to DICOM, Convert DICOM to
Image Converter Pro - JPEG to DICOM Converter. Convert JPEG (JPG) Images to, from DICOM Images on Windows.
adding a signature to a pdf form; add signature to pdf file
OpenCOBOL 1.1 Programmers Guide 
PROCEDURE DIVISION 
06FEB2009 Version 
Page 6-36 
6.8.
CANCEL 
Figure 6-34 - CANCEL Syntax 
The CANCEL statement unloads the dynamically-loadable 
module containing the entry-point specified as literal-1 or 
identifier-1 from memory. 
1.
If the dynamically-loadable module unloaded by the CANCEL is subsequently re-executed, all DATA DIVISION 
storage for that dynamically-loadable module will once again be in its initial state. 
CANCEL
identifier-1
literal-1
...
JPG to PNG Converter | Convert JPEG to PNG, Convert PNG to JPG
Image Converter Pro - JPEG to PNG Converter. Convert JPEG (JPG) Images to, from PNG Images on Windows.
create pdf signature field; pdf signatures
JPG to GIF Converter | Convert JPEG to GIF, Convert GIF to JPG
Converter. Convert JPEG (JPG) Images to, from GIF Images on Windows. JPEG to GIF Converter can directly convert GIF files to JPG files.
add signature field to pdf; adding signature to pdf files
OpenCOBOL 1.1 Programmers Guide 
PROCEDURE DIVISION 
06FEB2009 Version 
Page 6-37 
6.9.
CLOSE 
Figure 6-35 - CLOSE Syntax 
The CLOSE statement terminates 
the programs access to the 
specified file(s) or to the currently 
mounted reel/unit of the file(s). 
1.
The CLOSE statement may only be executed against files that have been successfully OPENed. 
2.
The REEL, UNIT and NO REWIND clauses are available only for ORGANIZATION SEQUENTIAL (either LINE or 
RECORD BINARY) SEQUENTIAL files.  The words REEL and UNIT may be used interchangeably, and reflect a file that 
is stored on or will be written to multiple removable tapes/disks.  Not all systems support such devices, and 
OpenCOBOL features to manipulate such multiple-unit files may not be functional on your system. 
3.
The REEL and UNIT phrases are intended for use with files which have had MULTIPLE REEL or MULTIPLE UNIT         
specified in their SELECT clause.  If the run-time system does not recognize multi-unit files, the CLOSE REEL and 
CLOSE UNIT statements will perform no function.   
4.
Once a file has been closed, it cannot be accessed again until it has been successfully re-OPENed. 
5.
A successful CLOSE without REEL or UNIT executed against a file that was OPENed in either OUTPUT or EXTEND 
mode will write any remaining unwritten record buffers to the file; regardless of OPEN mode, any record locks 
held for closed files will be released as well.  A closed file will then be no longer available for subsequent READ, 
WRITE, REWRITE, START or DELETE statements until it is once again OPENed. 
6.
A CLOSE WITH LOCK option will prevent your
program
from re-opening the file again in the same program 
execution. 
7.
A successful CLOSE with REEL or UNIT will write any remaining unwritten record buffers to the closed files and will 
release any record locks held for those files as well.  The currently mounted reel/unit of the file will be 
dismounted and the next reel/unit requested.  The file͛s status remains OPEN. 
CLOSE
file-name-1
REEL
UNIT
FOR REMOVAL
WITH LOCK
WITH NO
REWIND
...
OpenCOBOL 1.1 Programmers Guide 
PROCEDURE DIVISION 
06FEB2009 Version 
Page 6-38 
6.10.
COMMIT 
Figure 6-36 - COMMIT Syntax 
The COMMIT statement performs an UNLOCK against 
every currently-OPEN file. 
1.
See the UNLOCK statement (section 6.48
) for additional details. 
COMMIT
OpenCOBOL 1.1 Programmers Guide 
PROCEDURE DIVISION 
06FEB2009 Version 
Page 6-39 
6.11.
COMPUTE 
Figure 6-37 - COMPUTE Syntax 
The COMPUTE statement 
provides a means of easily 
performing complex 
arithmetic operations with a 
single statement, instead of 
using cumbersome and 
possibly confusing sequences 
of ADD, SUBTRACT, 
MULTIPLY and DIVIDE 
statements. 
1.
The word EQUAL and the equals-sign (=) may be used interchangeably. 
2.
The ON SIZE ERROR, NOT ON SIZE ERROR and ROUNDED clauses are coded and operate the same as the clauses of 
the same name available to the ADD statement (see section 6.5.1
). 
COMPUTE
{identifier-1 [ ROUNDED
] }...         
arithmetic-expression
[ ON SIZE
ERROR
imperative-statement-1 ]
[ NOT
ON SIZE
ERROR
imperative-statement-2 ]
EQUAL
=
[ END-COMPUTE
]
OpenCOBOL 1.1 Programmers Guide 
PROCEDURE DIVISION 
06FEB2009 Version 
Page 6-40 
6.12.
CONTINUE 
Figure 6-38 - CONTINUE Syntax 
The CONTINUE statement is a no-operation statement, 
performing no action whatsoever.   
1.
The CONTINUE statement is often used with IF statements (section 6.23
) as a place-holder for conditionally-
executed code that is either not yet needed or not yet designed.  The following two sentences are equivalent.  
One uses CONTINUE statements to mark places where code may need to be inserted in the future. 
͞Minimalist͟ Coding 
(Specifying only what is necessary) 
Coding With CONTINUE 
(Documenting where code might be needed someday) 
IF A = 1 
IF B = 1 
DISPLAY „A=1 & B=1‟ END-DISPLAY 
END-IF 
ELSE 
IF A = 2 
IF B = 2 
DISPLAY „A=2 & B=2‟ END-DISPLAY 
END-IF 
END-IF 
END-IF 
IF A = 1 
IF B = 1 
DISPLAY „A=1 & B=1‟ END-DISPLAY 
ELSE 
CONTINUE 
END-IF 
ELSE 
IF A = 2 
IF B = 2 
DISPLAY „A=2 & B=2‟ END-DISPLAY 
ELSE 
CONTINUE 
END-IF 
ELSE 
CONTINUE 
END-IF 
END-IF 
Coding such as this is generally a matter of personal preference or site coding standards.  There is no difference in 
the object code generated by the two, so there isn͛t a run-time efficiency issue (just one of ͞coding efficiency͟). 
2.
Another IF-statement usage for CONTINUE is to avoid the use of NOT in the conditional expression coded on the 
IF statement.  This too is a personal and/or site standards issue.  Here͛s an example: 
Without CONTINUE 
With CONTINUE 
IF Action-Flag NOT = „I‟ AND „U‟ 
DISPLAY „Invalid Action-Flag‟ 
EXIT PARAGRAPH 
END-IF 
IF Action-Flag = „I‟ OR „U‟ 
CONTINUE 
ELSE 
DISPLAY „Invalid Action-Flag‟ 
EXIT PARAGRAPH 
END-IF 
Because of the way COBOL (OpenCOBOL included) handles the abbreviation of conditional expressions, the 
conditional expression in the left-hand box is actually a short-hand version of the (not-so-intuitive): 
IF Action-Flag NOT = „I‟ AND Action-Flag NOT = „U‟ 
Many programmers would have coded the ͞IF͟ (incorrectly) as ͞
IF Action-Flag NOT = „I‟ OR „U‟
͟ – this 
is sure to cause run-time problems. 
This causes many programmers to consider the code in the right-hand box to be more readable, even though it is 
a little longer. 
CONTINUE
Documents you may be interested
Documents you may be interested